메뉴 건너뛰기




Volumn 15, Issue 1, 2014, Pages 274-278

The CT number accuracy of a novel commercial metal artifact reduction algorithm for large orthopedic implants

Author keywords

CT number accuracy; Metal artifact reduction; Metallic hip prosthesis

Indexed keywords


EID: 84891776934     PISSN: None     EISSN: 15269914     Source Type: Journal    
DOI: 10.1120/jacmp.v15i1.4597     Document Type: Article
Times cited : (37)

References (5)
  • 1
    • 0003954913 scopus 로고    scopus 로고
    • The physics of radiation therapy
    • 4th edition. Philadelphia (PA): Lippincott Williams&Wilkins
    • Khan FM. The physics of radiation therapy, 4th edition. Philadelphia (PA): Lippincott Williams&Wilkins; 2010.
    • (2010)
    • Khan, F.M.1
  • 2
    • 0142057571 scopus 로고    scopus 로고
    • Quality assurance for computed-tomography simulators and the computed-tomography-simulation process: report of the AAPM Radiation Therapy Committee Task Group No. 66.
    • Mutic S, Palta JR, Butker EK, et al. Quality assurance for computed-tomography simulators and the computed-tomography-simulation process: report of the AAPM Radiation Therapy Committee Task Group No. 66. Med Phys. 2003;30(10):2762-91.
    • (2003) Med Phys. , vol.30 , Issue.10 , pp. 2762-2791
    • Mutic, S.1    Palta, J.R.2    Butker, E.K.3
  • 3
    • 84946921877 scopus 로고    scopus 로고
    • Metal artifact reduction for orthopedic implants (O-MAR), white paper [Internet]
    • Philips CT Clinical Science, Andover, MA: Philips Healthcare USA, [cited 2013 Jun 26]
    • Philips CT Clinical Science. Metal artifact reduction for orthopedic implants (O-MAR), white paper [Internet]. Andover, MA: Philips Healthcare USA; 2012. [cited 2013 Jun 26]. Available from: http://clinical.netforum.healthcare.philips.com/us_en/Explore/White-Papers/CT/Metal-Artifact-Reduction-for-Orthopedic-Implants-(O-MAR)
    • (2012)
  • 4
    • 10744226022 scopus 로고    scopus 로고
    • Dosimetric considerations for patients with hip prostheses undergoing pelvic irradiation: report of the AAPM Radiation Therapy Committee Task Group 63
    • Reft C, Alecu R, Das IJ, et al. Dosimetric considerations for patients with hip prostheses undergoing pelvic irradiation: report of the AAPM Radiation Therapy Committee Task Group 63. Med Phys. 2003;30(6):1162-82.
    • (2003) Med Phys. , vol.30 , Issue.6 , pp. 1162-1182
    • Reft, C.1    Alecu, R.2    Das, I.J.3
  • 5
    • 84870927687 scopus 로고    scopus 로고
    • Clinical evaluation of a commercial orthopedic metal artifact reduction tool for CT simulations in radiation therapy
    • Li H, Noel C, Chen H, et al. Clinical evaluation of a commercial orthopedic metal artifact reduction tool for CT simulations in radiation therapy. Med Phys. 2012;39(12):7507-17.
    • (2012) Med Phys. , vol.39 , Issue.12 , pp. 7507-7517
    • Li, H.1    Noel, C.2    Chen, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.