메뉴 건너뛰기




Volumn 29, Issue 1, 2014, Pages 349-358

Electromechanical mode estimation using recursive adaptive stochastic subspace identification

Author keywords

Electromechanical modes; power system oscillations; recursive estimation; small signal stability; stochastic subspace identification; wide area measurement systems (WAMS)

Indexed keywords

ELECTROMECHANICAL MODES; POWER SYSTEM OSCILLATIONS; RECURSIVE ESTIMATION; SMALL SIGNAL STABILITY; STOCHASTIC SUBSPACE IDENTIFICATION; WIDE AREA MEASUREMENT SYSTEMS;

EID: 84891556578     PISSN: 08858950     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPWRS.2013.2281004     Document Type: Article
Times cited : (167)

References (26)
  • 2
    • 0031197480 scopus 로고    scopus 로고
    • Initial results in electromechanical mode identification from ambient data
    • Aug.
    • J. W. Pierre, D. J. Trudnowski, and M. K. Donnely, "Initial results in electromechanical mode identification from ambient data," IEEE Trans. Power Syst., 12, 3, 1245-1250, Aug. 1997.
    • (1997) IEEE Trans. Power Syst. , vol.12 , Issue.3 , pp. 1245-1250
    • Pierre, J.W.1    Trudnowski, D.J.2    Donnely, M.K.3
  • 3
    • 47949114430 scopus 로고    scopus 로고
    • Oscillation monitoring system based on wide area synchrophasors in power systems
    • Aug. 19-24 Bulk Power System Dynamics and Control-VII
    • G. Liu, J. Quintero, and V. Venkatasubramanian, "Oscillation monitoring system based on wide area synchrophasors in power systems," in Proc. IREP, Aug. 19-24, 2007, Bulk Power System Dynamics and Control-VII.
    • (2007) Proc. IREP
    • Liu, G.1    Quintero, J.2    Venkatasubramanian, V.3
  • 4
    • 51749109549 scopus 로고    scopus 로고
    • Oscillation monitoring from ambient PMU measurements by frequency domain decomposition
    • May
    • G. Liu and V. Venkatasubramanin, "Oscillation monitoring from ambient PMU measurements by frequency domain decomposition," in Proc. IEEE Int. Symp. Circuit and Systems,May 2008, 2821-2824.
    • (2008) Proc. IEEE Int. Symp. Circuit and Systems , pp. 2821-2824
    • Liu, G.1    Venkatasubramanin, V.2
  • 6
    • 43849093477 scopus 로고    scopus 로고
    • Performance of threemode-meter block-processing algorithms for automated dynamic stability assessment
    • May
    • D. J. Trudnowski, J.W. Pierre,N. Zhou, J. F.Hauer, and M. Parashar, "Performance of threemode-meter block-processing algorithms for automated dynamic stability assessment," IEEE Trans. Power Syst., 23, 2, 680-689, May 2008.
    • (2008) IEEE Trans. Power Syst. , vol.23 , Issue.2 , pp. 680-689
    • Trudnowski, D.J.1    Pierre, J.W.2    Zhou, N.3    Hauer, J.F.4    Parashar, M.5
  • 7
    • 33747628096 scopus 로고    scopus 로고
    • Initial results in power system identification from injected probing signals using a subspace method
    • Aug.
    • N. Zhou, J. W. Pierre, and J. F. Hauer, "Initial results in power system identification from injected probing signals using a subspace method," IEEE Trans. Power Syst., 21, 3, 1266-1302, Aug. 2006.
    • (2006) IEEE Trans. Power Syst. , vol.21 , Issue.3 , pp. 1266-1302
    • Zhou, N.1    Pierre, J.W.2    Hauer, J.F.3
  • 8
    • 33646345828 scopus 로고    scopus 로고
    • Oscillatory stability limit prediction using stochastic subspace identification
    • May
    • H. Ghasemi, C. Canizares, and A. Moshref, "Oscillatory stability limit prediction using stochastic subspace identification," IEEE Trans. Power Syst., 21, 2, 736-745, May 2006.
    • (2006) IEEE Trans. Power Syst. , vol.21 , Issue.2 , pp. 736-745
    • Ghasemi, H.1    Canizares, C.2    Moshref, A.3
  • 9
    • 82855168011 scopus 로고    scopus 로고
    • Estimating the electromechanical oscillation characteristic of power system based on measured ambient data utilizing stochastic subspace method
    • July
    • N. Jingmin, S. Chen, and L. Feng, "Estimating the electromechanical oscillation characteristic of power system based on measured ambient data utilizing stochastic subspace method," in Proc. IEEE Power and Energy Society General Meeting, July 2011.
    • (2011) Proc. IEEE Power and Energy Society General Meeting
    • Jingmin, N.1    Chen, S.2    Feng, L.3
  • 10
    • 71849115071 scopus 로고    scopus 로고
    • Monitoring of inter-area oscillations under ambient conditions using subspace identification
    • Jul.
    • M. Larsson and D. S. Laila, "Monitoring of inter-area oscillations under ambient conditions using subspace identification," in Proc. IEEE Power and Energy Society General Meeting, Jul. 2009.
    • (2009) Proc. IEEE Power and Energy Society General Meeting
    • Larsson, M.1    Laila, D.S.2
  • 12
    • 34548039747 scopus 로고    scopus 로고
    • Robust RLS methods for online estimation of power system electromechanical modes
    • DOI 10.1109/TPWRS.2007.901104
    • N. Zhou, J. W. Pierre, D. J. Trudnowski, and R. T. Guttromoson, "Robust RLS methods for online estimation of power system electromechanical modes," IEEE Trans. Power Syst., 22, 3, 1240-1249, Aug. 2007. (Pubitemid 47278383)
    • (2007) IEEE Transactions on Power Systems , vol.22 , Issue.3 , pp. 1240-1249
    • Zhou, N.1    Pierre, J.W.2    Trudnowski, D.J.3    Guttromson, R.T.4
  • 13
    • 70350562094 scopus 로고    scopus 로고
    • Electromechanical mode online estimation using regularized robust RLS methods
    • Nov.
    • N. Zhou, D. J. Trudnowski, J. W. Pierre, and W. A. Mittelstadt, "Electromechanical mode online estimation using regularized robust RLS methods," IEEE Trans. Power Syst., 23, 4, 1670-1680, Nov. 2008.
    • (2008) IEEE Trans. Power Syst. , vol.23 , Issue.4 , pp. 1670-1680
    • Zhou, N.1    Trudnowski, D.J.2    Pierre, J.W.3    Mittelstadt, W.A.4
  • 17
    • 77957558905 scopus 로고    scopus 로고
    • Recursive output only subspace identification for in-flight flutter monitoring
    • (IMACXXII) Jan. 26-29
    • I. Goethals, L. Mevel, A. Benveniste, and B. D. Moore, "Recursive output only subspace identification for in-flight flutter monitoring," in Proc. 22nd Int. Modal Analysis Conf. (IMACXXII), Jan. 26-29, 2004.
    • (2004) Proc. 22nd Int. Modal Analysis Conf.
    • Goethals, I.1    Mevel, L.2    Benveniste, A.3    Moore, B.D.4
  • 18
    • 0019242054 scopus 로고
    • Discrete-continuous model conversion
    • Dec.
    • L. S. Shieh, H. Wang, and R. E. Yates, "Discrete-continuous model conversion," Appl.Math. Model., 4, 6, 449-455, Dec. 1980.
    • (1980) Appl.Math. Model. , vol.4 , Issue.6 , pp. 449-455
    • Shieh, L.S.1    Wang, H.2    Yates, R.E.3
  • 19
    • 0032023824 scopus 로고    scopus 로고
    • Instrumental variable subspace tracking using projection approximation
    • PII S1053587X98020017
    • T. Gustafsson, "Instrumental variable subspace tracking using projection approximation," IEEE Trans. Signal Process., 46, 3, 669-681, Mar. 1998. (Pubitemid 128743772)
    • (1998) IEEE Transactions on Signal Processing , vol.46 , Issue.3 , pp. 669-681
    • Gustafsson, T.1
  • 20
    • 67650160420 scopus 로고    scopus 로고
    • A robust variable forgetting factor recursive least-squares algorithm for system identification
    • Oct.
    • C. Paleologo, J. Benesty, and S. Ciochina, "A robust variable forgetting factor recursive least-squares algorithm for system identification," IEEE Signal Process. Lett., 15, 597-600, Oct. 2008.
    • (2008) IEEE Signal Process. Lett. , vol.15 , pp. 597-600
    • Paleologo, C.1    Benesty, J.2    Ciochina, S.3
  • 21
    • 25444457795 scopus 로고    scopus 로고
    • Gradient-based variable forgetting factor RLS algorithm in time-varying environments
    • DOI 10.1109/TSP.2005.851110
    • S. Leung and C. F. So, "Gradient-based variable forgetting factor RLS algorithm in time-varying environments," IEEE Trans. Signal Process., 53, 8, 3141-3150, Aug. 2005. (Pubitemid 41372822)
    • (2005) IEEE Transactions on Signal Processing , vol.53 , Issue.8 , pp. 3141-3150
    • Leung, S.-H.1    So, C.F.2
  • 22
    • 84886443702 scopus 로고    scopus 로고
    • Oscillation modal analysis from ambient synchrophasor data using distributed frequency domain optimization
    • May
    • J. Ning, X. Pan, and V. Venkatasubramanian, "Oscillation modal analysis from ambient synchrophasor data using distributed frequency domain optimization," IEEE Trans. Power Syst., 28, 2, 1960-1968, May 2013.
    • (2013) IEEE Trans. Power Syst. , vol.28 , Issue.2 , pp. 1960-1968
    • Ning, J.1    Pan, X.2    Venkatasubramanian, V.3
  • 23
    • 84891556281 scopus 로고    scopus 로고
    • Roadmap to monitor data collected during the WSCC breakup of August 10, 1996
    • Richland, WA, USA. [Online]. Available
    • J. F. Hauer and J. W. Burns, "Roadmap to monitor data collected during the WSCC breakup of August 10, 1996," in PNNL-19459, Pacific Northwest National Laboratory, Richland, WA, USA. [Online]. Available: http://www.pnl.gov/main/publications/external/technical-reports/PNNL-19459.pdf.
    • PNNL-19459, Pacific Northwest National Laboratory
    • Hauer, J.F.1    Burns, J.W.2
  • 25
    • 84860227388 scopus 로고    scopus 로고
    • A stepwise regression method for estimating dominant electromechanical modes
    • May
    • N. Zhou, J. W. Pierre, and D. Trudnowski, "A stepwise regression method for estimating dominant electromechanical modes," IEEE Trans. Power Syst., 27, 2, 1051-1059, May 2012.
    • (2012) IEEE Trans. Power Syst. , vol.27 , Issue.2 , pp. 1051-1059
    • Zhou, N.1    Pierre, J.W.2    Trudnowski, D.3
  • 26
    • 70349167058 scopus 로고    scopus 로고
    • Mode initialization for on-line estimation of power systemelectromechanicalmodes
    • Mar.
    • N. Zhou, D. Trudnowski, and J. W. Pierre, "Mode initialization for on-line estimation of power systemelectromechanicalmodes," in Proc. IEEE Power Systems Conf. Expo., Mar. 2009, 1-8.
    • (2009) Proc. IEEE Power Systems Conf. Expo. , pp. 1-8
    • Zhou, N.1    Trudnowski, D.2    Pierre, J.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.