-
1
-
-
33646093453
-
Cochlear nerve size evaluation in children with sensorineural hearing loss by high-resolution magnetic resonance imaging
-
Russo EE, Manolidis S, Morriss MC. Cochlear nerve size evaluation in children with sensorineural hearing loss by high-resolution magnetic resonance imaging. Am J Otolaryngol 2006; 27: 166-172.
-
(2006)
Am J Otolaryngol
, vol.27
, pp. 166-172
-
-
Russo, E.E.1
Manolidis, S.2
Morriss, M.C.3
-
2
-
-
0033982202
-
Reduced size of the cochlear branch of the vestibulocochlear nerve in a child with sensorineural hearing loss
-
Furuta S, Ogura M, Higano S, Takahashi S, Kawase T. Reduced size of the cochlear branch of the vestibulocochlear nerve in a child with sensorineural hearing loss. AJNR Am J Neuroradiol 2000; 21: 328-330.
-
(2000)
AJNR Am J Neuroradiol
, vol.21
, pp. 328-330
-
-
Furuta, S.1
Ogura, M.2
Higano, S.3
Takahashi, S.4
Kawase, T.5
-
3
-
-
0033491718
-
Cochlear nerve aplasia: Its importance in cochlear implantation
-
Maxwell AP, Mason SM, O'Donoghue GM. Cochlear nerve aplasia: its importance in cochlear implantation. Am J Otol 1999; 20: 335-337.
-
(1999)
Am J Otol
, vol.20
, pp. 335-337
-
-
Maxwell, A.P.1
Mason, S.M.2
O'Donoghue, G.M.3
-
4
-
-
0031052372
-
Aplasia and hypoplasia of the vestibulocochlear nerve: Diagnosis with MR imaging
-
Casselman JW, Offeciers FE, Govaerts PJ, et al. Aplasia and hypoplasia of the vestibulocochlear nerve: diagnosis with MR imaging. Radiology 1997; 202: 773-781.
-
(1997)
Radiology
, vol.202
, pp. 773-781
-
-
Casselman, J.W.1
Offeciers, F.E.2
Govaerts, P.J.3
-
5
-
-
0026749553
-
Diameter of the cochlear nerve in deaf humans: Implications for cochlear implantation
-
Nadol JB Jr, Xu WZ. Diameter of the cochlear nerve in deaf humans: implications for cochlear implantation. Ann Otol Rhinol Laryngol 1992; 101: 988-993.
-
(1992)
Ann Otol Rhinol Laryngol
, vol.101
, pp. 988-993
-
-
Nadol Jr., J.B.1
Xu, W.Z.2
-
6
-
-
79958018431
-
Measurement of the facial nerve caliber in facial palsy: Implications for facial nerve decompression
-
Hagino K, Tsunoda A, Tsunoda R, Kishimoto S. Measurement of the facial nerve caliber in facial palsy: implications for facial nerve decompression. Otol Neurotol 2011; 32: 686-689.
-
(2011)
Otol Neurotol
, vol.32
, pp. 686-689
-
-
Hagino, K.1
Tsunoda, A.2
Tsunoda, R.3
Kishimoto, S.4
-
8
-
-
77953239285
-
Evaluation of cochlear nerve size by magnetic resonance imaging in elderly patients with sensorineural hearing loss
-
[Article in English and Italian]
-
Sildiroglu O, Cincik H, Sonmez G, et al. Evaluation of cochlear nerve size by magnetic resonance imaging in elderly patients with sensorineural hearing loss. Radiol Med 2010; 115: 483-487. [Article in English and Italian].
-
(2010)
Radiol Med
, vol.115
, pp. 483-487
-
-
Sildiroglu, O.1
Cincik, H.2
Sonmez, G.3
-
9
-
-
85047686831
-
Differences in cochlear nerve cross-sectional area between normal hearing and postlingually deafened patients on MRI
-
Herman B, Angeli S. Differences in cochlear nerve cross-sectional area between normal hearing and postlingually deafened patients on MRI. Otolaryngol Head Neck Surg 2011; 144: 64-66.
-
(2011)
Otolaryngol Head Neck Surg
, vol.144
, pp. 64-66
-
-
Herman, B.1
Angeli, S.2
-
10
-
-
0026247740
-
A guide to understanding key aspects of fast gradient-echo imaging
-
Haacke EM, Frahm J. A guide to understanding key aspects of fast gradient-echo imaging. J Magn Reson Imaging 1991; 1: 621-624.
-
(1991)
J Magn Reson Imaging
, vol.1
, pp. 621-624
-
-
Haacke, E.M.1
Frahm, J.2
-
11
-
-
70349928624
-
Cochlear nerve diameter in normal hearing ears using high-resolution magnetic resonance imaging
-
Jaryszak EM, Patel NA, Camp M, Mancuso AA, Antonelli PJ. Cochlear nerve diameter in normal hearing ears using high-resolution magnetic resonance imaging. Laryngoscope 2009; 119: 2042-2045.
-
(2009)
Laryngoscope
, vol.119
, pp. 2042-2045
-
-
Jaryszak, E.M.1
Patel, N.A.2
Camp, M.3
Mancuso, A.A.4
Antonelli, P.J.5
-
12
-
-
84862785514
-
Normative diameters and effects of aging on the cochlear and facial nerves in normal-hearing Korean ears using 3. 0-tesla magnetic resonance imaging
-
Kang WS, Hyun SM, Lim HK, Shim BS, Cho JH, Lee KS. Normative diameters and effects of aging on the cochlear and facial nerves in normal-hearing Korean ears using 3. 0-tesla magnetic resonance imaging. Laryngoscope 2012; 122: 1109-1114.
-
(2012)
Laryngoscope
, vol.122
, pp. 1109-1114
-
-
Kang, W.S.1
Hyun, S.M.2
Lim, H.K.3
Shim, B.S.4
Cho, J.H.5
Lee, K.S.6
-
13
-
-
34147193807
-
Nephrogenic systemiffibrosis: Risk factors and incidence estimation
-
Sadowski EA, Bennett LK, Chan MR, et al. Nephrogenic systemiffibrosis: risk factors and incidence estimation. Radiology 2007; 243: 148-157.
-
(2007)
Radiology
, vol.243
, pp. 148-157
-
-
Sadowski, E.A.1
Bennett, L.K.2
Chan, M.R.3
-
14
-
-
38049169188
-
Correlation betweenMRI and operativêndings in Bell's palsy and Ramsay Hunt syndrome
-
Kim IS, Shin SH, Kim J, Lee WS, Lee HK. Correlation betweenMRI and operativêndings in Bell's palsy and Ramsay Hunt syndrome. Yonsei Med J 2007; 48: 963-968.
-
(2007)
Yonsei Med J
, vol.48
, pp. 963-968
-
-
Kim, I.S.1
Shin, S.H.2
Kim, J.3
Lee, W.S.4
Lee, H.K.5
-
15
-
-
0024531729
-
Histopathology of Bell's palsy
-
Liston SL, Kleid MS. Histopathology of Bell's palsy. Laryngoscope 1989; 99: 23-26.
-
(1989)
Laryngoscope
, vol.99
, pp. 23-26
-
-
Liston, S.L.1
Kleid, M.S.2
-
17
-
-
0015323616
-
Total intratemporal exposure of the facial nerve. Pathologiffindings in Bell's palsy
-
Fisch U, Esslen E. Total intratemporal exposure of the facial nerve. Pathologiffindings in Bell's palsy. Arch Otolaryngol 1972; 95: 335-341.
-
(1972)
Arch Otolaryngol
, vol.95
, pp. 335-341
-
-
Fisch, U.1
Esslen, E.2
-
18
-
-
0242544919
-
The structure of the facial nerve
-
Sunderland S, Cossar DF. The structure of the facial nerve. Anat Rec 1953; 116: 147-165.
-
(1953)
Anat Rec
, vol.116
, pp. 147-165
-
-
Sunderland, S.1
Cossar, D.F.2
-
19
-
-
84856079287
-
CT analysis demonstrates that cochlear height does not change with age
-
Mori MC, Chang KW. CT analysis demonstrates that cochlear height does not change with age. AJNR Am J Neuroradiol 2012; 33: 119-123.
-
(2012)
AJNR Am J Neuroradiol
, vol.33
, pp. 119-123
-
-
Mori, M.C.1
Chang, K.W.2
-
20
-
-
84867788749
-
Accuracy and precision of vessel area assessment: Manual versus automatic lumen delineation based on full-width at half-maximum
-
Merkx MA, Bescós JO, Geerts L, Bosboom EM, van de Vosse FN, Breeuwer M. Accuracy and precision of vessel area assessment: manual versus automatic lumen delineation based on full-width at half-maximum. J Magn Reson Imaging 2012; 36: 1186-1193.
-
(2012)
J Magn Reson Imaging
, vol.36
, pp. 1186-1193
-
-
Merkx, M.A.1
Bescós, J.O.2
Geerts, L.3
Bosboom, E.M.4
van de Vosse, F.N.5
Breeuwer, M.6
-
21
-
-
0031784731
-
Limits to the accuracy of vessel diameter measurement in MR angiography
-
Hoogeveen RM, Bakker CJ, Viergever MA. Limits to the accuracy of vessel diameter measurement in MR angiography. J Magn Reson Imaging 1998; 8: 1228-1235.
-
(1998)
J Magn Reson Imaging
, vol.8
, pp. 1228-1235
-
-
Hoogeveen, R.M.1
Bakker, C.J.2
Viergever, M.A.3
|