메뉴 건너뛰기




Volumn 114, Issue , 2014, Pages 48-52

Development of a micro-analytical prototype for selective trace detection of orthonitrotoluene

Author keywords

Explosive agents; Gas micro preconcentrator; Gas sensor; GC micro column; Micro system; Zeolite

Indexed keywords


EID: 84890888794     PISSN: 0026265X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.microc.2013.12.001     Document Type: Article
Times cited : (23)

References (20)
  • 1
    • 0036062587 scopus 로고    scopus 로고
    • Field detection and monitoring of explosives
    • Yinon J. Field detection and monitoring of explosives. Trends Anal. Chem. 2002, 21:292-301.
    • (2002) Trends Anal. Chem. , vol.21 , pp. 292-301
    • Yinon, J.1
  • 2
    • 75449100759 scopus 로고    scopus 로고
    • Gas saturation vapor pressure measurements of mononitrotoluene isomers from (283.15 to 313.15K)
    • Widegren J.A., Bruno T.J. Gas saturation vapor pressure measurements of mononitrotoluene isomers from (283.15 to 313.15K). J. Chem. Eng. Data 2010, 55:159-164.
    • (2010) J. Chem. Eng. Data , vol.55 , pp. 159-164
    • Widegren, J.A.1    Bruno, T.J.2
  • 3
    • 33744928388 scopus 로고    scopus 로고
    • Detection of explosives and explosives-related compounds by single photon laser ionization time-of-flight mass spectrometry
    • Mullen C., Irwin A., Pond B.V., Huestis D.L., Coggiola M.G., Oser H. Detection of explosives and explosives-related compounds by single photon laser ionization time-of-flight mass spectrometry. Anal. Chem. 2006, 78:3807-3814.
    • (2006) Anal. Chem. , vol.78 , pp. 3807-3814
    • Mullen, C.1    Irwin, A.2    Pond, B.V.3    Huestis, D.L.4    Coggiola, M.G.5    Oser, H.6
  • 4
    • 0029989671 scopus 로고    scopus 로고
    • Investigation into an explosion and fire in a mononitrotoluene manufacturing plant
    • Cutler D.P., Brown A.K. Investigation into an explosion and fire in a mononitrotoluene manufacturing plant. J. Hazard. Mater. 1996, 46:169-183.
    • (1996) J. Hazard. Mater. , vol.46 , pp. 169-183
    • Cutler, D.P.1    Brown, A.K.2
  • 6
    • 84872549794 scopus 로고    scopus 로고
    • Gas phase micro-preconcentrators for benzene monitoring: a review
    • Lahlou H., Vilanova X., Correig X. Gas phase micro-preconcentrators for benzene monitoring: a review. Sens. Actuators B 2013, 176:198-210.
    • (2013) Sens. Actuators B , vol.176 , pp. 198-210
    • Lahlou, H.1    Vilanova, X.2    Correig, X.3
  • 9
    • 79951682746 scopus 로고    scopus 로고
    • A micro gas preconcentrator with improved performance for pollution monitoring and explosives detection
    • Camara E.H.M., Breuil P., Briand D., de Rooij N.F., Pijolat C. A micro gas preconcentrator with improved performance for pollution monitoring and explosives detection. Anal. Chim. Acta. 2011, 688:175-182.
    • (2011) Anal. Chim. Acta. , vol.688 , pp. 175-182
    • Camara, E.H.M.1    Breuil, P.2    Briand, D.3    de Rooij, N.F.4    Pijolat, C.5
  • 10
    • 46449112643 scopus 로고    scopus 로고
    • MEMS-based multi-inlet/outlet preconcentrator coated by inkjet printing of polymer adsorbents
    • Alfeeli B., Cho D., Khorassani M.A., Taylor L.T., Agah M. MEMS-based multi-inlet/outlet preconcentrator coated by inkjet printing of polymer adsorbents. Sens. Actuators B 2008, 133:24-32.
    • (2008) Sens. Actuators B , vol.133 , pp. 24-32
    • Alfeeli, B.1    Cho, D.2    Khorassani, M.A.3    Taylor, L.T.4    Agah, M.5
  • 11
    • 77950629722 scopus 로고    scopus 로고
    • Evaluation of tenax TA thin films as adsorbent material for micro preconcentration applications
    • Alfeeli B., Taylor L.T., Agah M. Evaluation of tenax TA thin films as adsorbent material for micro preconcentration applications. Microchem. J. 2010, 95:259-267.
    • (2010) Microchem. J. , vol.95 , pp. 259-267
    • Alfeeli, B.1    Taylor, L.T.2    Agah, M.3
  • 12
    • 67949117037 scopus 로고    scopus 로고
    • Realtime monitoring of sub-ppb concentrations of aromatic volatiles with a MEMS enabled miniaturized gas chromatograph
    • Zampolli S., Elmi I., Mancarella F., Betti P., Dalcanale E., Cardinali G.C., Severi M. Realtime monitoring of sub-ppb concentrations of aromatic volatiles with a MEMS enabled miniaturized gas chromatograph. Sens. Actuators B 2009, 141:322-328.
    • (2009) Sens. Actuators B , vol.141 , pp. 322-328
    • Zampolli, S.1    Elmi, I.2    Mancarella, F.3    Betti, P.4    Dalcanale, E.5    Cardinali, G.C.6    Severi, M.7
  • 13
    • 84861208485 scopus 로고    scopus 로고
    • 2 gas detector for analysis of low molecular weight hydrocarbons with focus on ethylene detection
    • 2 gas detector for analysis of low molecular weight hydrocarbons with focus on ethylene detection. Sens. Actuators B 2013, 180:43-49.
    • (2013) Sens. Actuators B , vol.180 , pp. 43-49
    • Sklorz, A.1    Janßen, S.2    Lang, W.3
  • 14
    • 78650758349 scopus 로고    scopus 로고
    • Silicon-micromachined gas chromatographic columns for the development of portable detection device
    • Sanchez J.-B., Schmitt A., Berger F., Mavon C. Silicon-micromachined gas chromatographic columns for the development of portable detection device. J. Sens. 2010, 2010. 8 pp.
    • (2010) J. Sens. , vol.2010 , pp. 8
    • Sanchez, J.-B.1    Schmitt, A.2    Berger, F.3    Mavon, C.4
  • 15
    • 0034726137 scopus 로고    scopus 로고
    • Preparation of stationary phases for open-tubular capillary electrochromatography using the sol-gel method
    • Constantin S., Freitag R. Preparation of stationary phases for open-tubular capillary electrochromatography using the sol-gel method. J. Chromatogr. A 2000, 887:253-263.
    • (2000) J. Chromatogr. A , vol.887 , pp. 253-263
    • Constantin, S.1    Freitag, R.2
  • 18
    • 33748516974 scopus 로고    scopus 로고
    • A selective gas detection micro-device for monitoring the volatile organic compounds pollution
    • Sanchez J.-B., Berger F., Fromm M., Nadal M.-H. A selective gas detection micro-device for monitoring the volatile organic compounds pollution. Sens. Actuators B 2006, 119(1):227-233.
    • (2006) Sens. Actuators B , vol.119 , Issue.1 , pp. 227-233
    • Sanchez, J.-B.1    Berger, F.2    Fromm, M.3    Nadal, M.-H.4
  • 19
    • 79958176954 scopus 로고    scopus 로고
    • Toward a GC-based microsystem for benzene and 1,3 butadiene detection: preconcentrator characterization
    • Lahlou H., Sanchez J.-B., Vilanova X., Berger F., Correig X., Fierro V., Celzard A. Toward a GC-based microsystem for benzene and 1,3 butadiene detection: preconcentrator characterization. Sens. Actuators B 2011, 156(2):680-688.
    • (2011) Sens. Actuators B , vol.156 , Issue.2 , pp. 680-688
    • Lahlou, H.1    Sanchez, J.-B.2    Vilanova, X.3    Berger, F.4    Correig, X.5    Fierro, V.6    Celzard, A.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.