메뉴 건너뛰기




Volumn , Issue , 2012, Pages

Measuring known aberrations in rat brain slices with coherence-gated wavefront sensor based on a linnik interferometer

Author keywords

[No Author keywords available]

Indexed keywords

COHERENT SCATTERING; INTERFEROMETERS; RATS; WAVEFRONTS;

EID: 84890772284     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1364/biomed.2012.btu3a.83     Document Type: Conference Paper
Times cited : (1)

References (6)
  • 1
    • 0036098166 scopus 로고    scopus 로고
    • Adaptive correction of depth-induced aberrations in multiphoton scanning microscopy using a deformable mirror
    • L. Sherman, J. Y. Ye, O. Albert, and T. B. Norris, "Adaptive correction of depth-induced aberrations in multiphoton scanning microscopy using a deformable mirror," J Microsc 206, 65-71 (2002).
    • (2002) J Microsc , vol.206 , pp. 65-71
    • Sherman, L.1    Ye, J.Y.2    Albert, O.3    Norris, T.B.4
  • 3
    • 37549066948 scopus 로고    scopus 로고
    • Properties of coherence-gated wavefront sensing
    • M. Rueckel and W. Denk, "Properties of coherence-gated wavefront sensing," J Opt Soc Am A 24, 3517-3529 (2007).
    • (2007) J Opt Soc Am A , vol.24 , pp. 3517-3529
    • Rueckel, M.1    Denk, W.2
  • 4
    • 33751253783 scopus 로고    scopus 로고
    • Adaptive wavefront correction in two-photon microscopy using coherence-gated wavefront sensing
    • M. Rueckel, J. A. Mack-Bucher, and W. Denk, "Adaptive wavefront correction in two-photon microscopy using coherence-gated wavefront sensing," Proc Natl Acad Sci U S A 103, 17137-17142 (2006).
    • (2006) Proc Natl Acad Sci U S A , vol.103 , pp. 17137-17142
    • Rueckel, M.1    Mack-Bucher, J.A.2    Denk, W.3
  • 5
    • 6444222151 scopus 로고    scopus 로고
    • Coherence-gated wave-front sensing in strongly scattering samples
    • M. Feierabend, M. Ruckel, and W. Denk, "Coherence-gated wave-front sensing in strongly scattering samples," Opt Lett 29, 2255-2257 (2004).
    • (2004) Opt Lett , vol.29 , pp. 2255-2257
    • Feierabend, M.1    Ruckel, M.2    Denk, W.3
  • 6
    • 79952579128 scopus 로고    scopus 로고
    • Brain refractive index measured in vivo with high-NA defocus-corrected full-field OCT and consequences for two-photon microscopy
    • J. Binding, J. Ben Arous, J. F. Leger, S. Gigan, C. Boccara, and L. Bourdieu, "Brain refractive index measured in vivo with high-NA defocus-corrected full-field OCT and consequences for two-photon microscopy," Opt Express 19, 4833-4847 (2011).
    • (2011) Opt Express , vol.19 , pp. 4833-4847
    • Binding, J.1    Ben Arous, J.2    Leger, J.F.3    Gigan, S.4    Boccara, C.5    Bourdieu, L.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.