Volumn 36, Issue 8, 2013, Pages 2251-2261

Partialization losses of ON/OFF operation of water-to-water refrigeration/heat-pump units

Author keywords

COP; Heat pump performance; Part load operation; Partialization losses

Indexed keywords

COEFFICIENT OF PERFORMANCE; COP; ELECTRICAL CONSUMPTION; EXPERIMENTAL CAMPAIGN; HEAT PUMPS; PART LOAD OPERATION; SEASONAL PERFORMANCE; STEADY-STATE CONDITION;

EID: 84890568378     PISSN: 01407007     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijrefrig.2013.07.002     Document Type: Article
Times cited : (26)

References (20)
  • 3
    • 77955429900 scopus 로고    scopus 로고
    • A simplified method to evaluate the seasonal energy performance of water chillers
    • L. Cecchinato, M. Chiarello, and M. Corradi A simplified method to evaluate the seasonal energy performance of water chillers Int. J. Therm. Sci. 2010 1 11
    • (2010) Int. J. Therm. Sci. , pp. 1-11
    • Cecchinato, L.1    Chiarello, M.2    Corradi, M.3
  • 5
    • 78049462467 scopus 로고    scopus 로고
    • A quasi-steady state mathematical model of an integrated ground source heat pump for building space control
    • J.M. Corberan, D.P. Finn, C. Montagud, F.T. Murphy, and K.C. Edwards A quasi-steady state mathematical model of an integrated ground source heat pump for building space control Energ. Build. 43 2011 82 92
    • (2011) Energ. Build. , vol.43 , pp. 82-92
    • Corberan, J.M.1    Finn, D.P.2    Montagud, C.3    Murphy, F.T.4    Edwards, K.C.5
  • 7
    • 0018517731 scopus 로고
    • New testing and rating procedures for seasonal performance of heat pumps
    • D. Didion, and G.E. Kelly New testing and rating procedures for seasonal performance of heat pumps ASHRAE J. September 1979 40 44
    • (1979) ASHRAE J. , pp. 40-44
    • Didion, D.1    Kelly, G.E.2
  • 9
    • 0001537397 scopus 로고
    • A note on the transient performance and degradation coefficient of a field tested heat pump - Cooling and heating mode
    • Pt 2
    • V.W. Goldschmidt, G.H. Hart, and R.C. Reiner A note on the transient performance and degradation coefficient of a field tested heat pump - cooling and heating mode ASHRAE Trans. 86 1980 Pt 2
    • (1980) ASHRAE Trans. , vol.86
    • Goldschmidt, V.W.1    Hart, G.H.2    Reiner, R.C.3
  • 11
    • 0011924416 scopus 로고
    • Cycling losses in domestic appliances: An experimental and theoretical analysis
    • M.J.P. Janssen, J.A. De Wit, and L.J. Kuijpers Cycling losses in domestic appliances: an experimental and theoretical analysis Int. J. Refrigeration 15 3 1992
    • (1992) Int. J. Refrigeration , vol.15 , Issue.3
    • Janssen, M.J.P.1    De Wit, J.A.2    Kuijpers, L.J.3
  • 13
    • 80755163483 scopus 로고    scopus 로고
    • Analysis of the energy performance of a ground source heat pump system after five years of operation
    • C. Montagud, J.M. Corberan, Á. Montero, and J.F. Urchueguía Analysis of the energy performance of a ground source heat pump system after five years of operation Energ. Build. 43 2011 3618 3626
    • (2011) Energ. Build. , vol.43 , pp. 3618-3626
    • Montagud, C.1    Corberan, J.M.2    Montero, Á.3    Urchueguía, J.F.4
  • 14
    • 0001622716 scopus 로고
    • Performance degradation during on-off cycling of single-speed air conditioners and heat pumps: Model development and analysis
    • D.L. O'Neal, and S. Katipamula Performance degradation during on-off cycling of single-speed air conditioners and heat pumps: model development and analysis ASHRAE Trans. 1993
    • (1993) ASHRAE Trans.
    • O'Neal, D.L.1    Katipamula, S.2
  • 15
    • 0017678594 scopus 로고
    • Factors affecting the performance of a residential air-to-air heat pump
    • No. 4269
    • W.H. Parken, R.W. Beausoliel, and G.E. Kelly Factors affecting the performance of a residential air-to-air heat pump ASHRAE Trans. 83 1 1977 839 849 No. 4269
    • (1977) ASHRAE Trans. , vol.83 , Issue.1 , pp. 839-849
    • Parken, W.H.1    Beausoliel, R.W.2    Kelly, G.E.3
  • 19
    • 0033907988 scopus 로고    scopus 로고
    • Heat pump seasonal performance evaluation: A proposal for a European standard
    • L. Schibuola Heat pump seasonal performance evaluation: a proposal for a European standard Appl. Therm. Eng. 20 2000 387 398
    • (2000) Appl. Therm. Eng. , vol.20 , pp. 387-398
    • Schibuola, L.1
  • 20
    • 44049122325 scopus 로고
    • Transient response and cycling losses of air-to-water heat pump systems
    • S.A. Tassou, and P. Votsis Transient response and cycling losses of air-to-water heat pump systems Heat Recovery Syst. CHP 12 2 1992 123 129
    • (1992) Heat Recovery Syst. CHP , vol.12 , Issue.2 , pp. 123-129
    • Tassou, S.A.1    Votsis, P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.