메뉴 건너뛰기




Volumn 36, Issue 8, 2013, Pages 2097-2110

Mechanical sub-cooling vapor compression systems: Current status and future directions

Author keywords

Performance improvement; Refrigeration system; Subcooling; Vapor compression

Indexed keywords

EXPERIMENTAL INVESTIGATIONS; PERFORMANCE CHARACTERISTICS; PERFORMANCE IMPROVEMENT; REFRIGERATION SYSTEM; SIMULATION OF PERFORMANCE CHARACTERISTICS; SUBCOOLINGS; VAPOR COMPRESSION; VAPOR-COMPRESSION SYSTEMS;

EID: 84890565069     PISSN: 01407007     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijrefrig.2013.07.026     Document Type: Review
Times cited : (49)

References (67)
  • 1
    • 0025531947 scopus 로고
    • Regression analysis of a residential air conditioning energy consumption in Dhahran, Saudi Arabia
    • D.Y. Abdel-Nabi, S.M. Zubair, M.A. Abdelrahman, and V.O. Bahel Regression analysis of a residential air conditioning energy consumption in Dhahran, Saudi Arabia ASHRAE Trans. 96 1990 223 232
    • (1990) ASHRAE Trans. , vol.96 , pp. 223-232
    • Abdel-Nabi, D.Y.1    Zubair, S.M.2    Abdelrahman, M.A.3    Bahel, V.O.4
  • 2
    • 42149101191 scopus 로고    scopus 로고
    • Evaporator air-side fouling: Effect on performance of room air conditioners and impact on indoor air quality
    • A.H.H. Ali, and I.M. Ismail Evaporator air-side fouling: effect on performance of room air conditioners and impact on indoor air quality HVAC&R Res. 14 2008 209 219
    • (2008) HVAC&R Res. , vol.14 , pp. 209-219
    • Ali, A.H.H.1    Ismail, I.M.2
  • 3
    • 0036235745 scopus 로고    scopus 로고
    • Thermoeconomic considerations in the optimum allocation of heat transfer inventory for refrigeration and heat pump systems
    • M.A. Antar, and S.M. Zubair Thermoeconomic considerations in the optimum allocation of heat transfer inventory for refrigeration and heat pump systems J. Energy Resour. Technol. 124 2002 28 33
    • (2002) J. Energy Resour. Technol. , vol.124 , pp. 28-33
    • Antar, M.A.1    Zubair, S.M.2
  • 4
    • 0006523440 scopus 로고    scopus 로고
    • A criterion for predicting the possible advantage of adopting a suction/liquid heat exchanger in refrigerating system
    • C. Aprea, M. Ascani, and F. de Rossi A criterion for predicting the possible advantage of adopting a suction/liquid heat exchanger in refrigerating system Appl. Therm. Eng. 19 4 1999 329 336
    • (1999) Appl. Therm. Eng. , vol.19 , Issue.4 , pp. 329-336
    • Aprea, C.1    Ascani, M.2    De Rossi, F.3
  • 5
    • 80052266444 scopus 로고    scopus 로고
    • Change in energy performance as a result of a R422D retrofit: An experimental analysis for a vapor compression refrigeration plant for a walk-in cooler
    • C. Aprea, A. Maiorino, and R. Mastrullo Change in energy performance as a result of a R422D retrofit: an experimental analysis for a vapor compression refrigeration plant for a walk-in cooler Appl. Energy 88 12 2011 4742 4748
    • (2011) Appl. Energy , vol.88 , Issue.12 , pp. 4742-4748
    • Aprea, C.1    Maiorino, A.2    Mastrullo, R.3
  • 6
    • 84890568430 scopus 로고
    • American Society of Heating, Refrigeration, and Air-Conditioning Engineers Inc. Atlanta, Georgia
    • ASHRAE Handbook, Equipment Volume 1983 American Society of Heating, Refrigeration, and Air-Conditioning Engineers Inc. Atlanta, Georgia
    • (1983) Handbook, Equipment Volume
  • 7
    • 0004053786 scopus 로고    scopus 로고
    • American Society of Heating, Refrigerating, and Air-Conditioning Engineers Inc. Atlanta, Georgia Chapter 2
    • ASHRAE Refrigeration Handbook 1998 American Society of Heating, Refrigerating, and Air-Conditioning Engineers Inc. Atlanta, Georgia Chapter 2
    • (1998) Refrigeration Handbook
  • 8
    • 0001384094 scopus 로고
    • Mechanical-subcooling improves supermarket refrigeration performance
    • V. Bahel, and S.M. Zubair Mechanical-subcooling improves supermarket refrigeration performance Heat-Piping-Air Cond 60 1988 105 107
    • (1988) Heat-Piping-Air Cond , vol.60 , pp. 105-107
    • Bahel, V.1    Zubair, S.M.2
  • 9
    • 0027609626 scopus 로고
    • Power and refrigeration plants for minimum heat exchanger inventory
    • A. Bejan Power and refrigeration plants for minimum heat exchanger inventory J. Energy Resour. Technol. 115 1993 148 150
    • (1993) J. Energy Resour. Technol. , vol.115 , pp. 148-150
    • Bejan, A.1
  • 10
    • 79951508672 scopus 로고    scopus 로고
    • Air-side particulate fouling of microchannel heat exchangers: Experimental comparison of air-side pressure drop and heat transfer with plate-fin heat exchanger
    • I.H. Bell, and E.A. Groll Air-side particulate fouling of microchannel heat exchangers: experimental comparison of air-side pressure drop and heat transfer with plate-fin heat exchanger Appl. Therm. Eng. 31 2010 742 749
    • (2010) Appl. Therm. Eng. , vol.31 , pp. 742-749
    • Bell, I.H.1    Groll, E.A.2
  • 11
    • 0029214265 scopus 로고
    • An experimental evaluation of capillary tube-liquid-suction heat exchanger performance with R152a
    • R.R. Bittle, W.R. Stephenson, and M.B. Pate An experimental evaluation of capillary tube-liquid-suction heat exchanger performance with R152a ASHRAE Trans. 101 1 1995 124 135
    • (1995) ASHRAE Trans. , vol.101 , Issue.1 , pp. 124-135
    • Bittle, R.R.1    Stephenson, W.R.2    Pate, M.B.3
  • 13
    • 78149362353 scopus 로고    scopus 로고
    • Transient simulation of household refrigerators: A semi-empirical quasi-steady approach
    • B.N. Borges, C.J.L. Hermes, J.M. Gonçalves, and C. Melo Transient simulation of household refrigerators: a semi-empirical quasi-steady approach Appl. Energy 88 3 2011 748 754
    • (2011) Appl. Energy , vol.88 , Issue.3 , pp. 748-754
    • Borges, B.N.1    Hermes, C.J.L.2    Gonçalves, J.M.3    Melo, C.4
  • 15
    • 0036568487 scopus 로고    scopus 로고
    • Emissions and environmental impacts from air-conditioning and refrigeration systems
    • J.M. Calm Emissions and environmental impacts from air-conditioning and refrigeration systems Int. J. Refrigeration 25 2002 293 305
    • (2002) Int. J. Refrigeration , vol.25 , pp. 293-305
    • Calm, J.M.1
  • 16
    • 77950866963 scopus 로고    scopus 로고
    • Design and experimental analysis of a carbon dioxide transcritical chiller for commercial refrigeration
    • L. Cecchinato, M. Chiarello, and M. Corradi Design and experimental analysis of a carbon dioxide transcritical chiller for commercial refrigeration Appl. Energy 87 2010 2095 2101
    • (2010) Appl. Energy , vol.87 , pp. 2095-2101
    • Cecchinato, L.1    Chiarello, M.2    Corradi, M.3
  • 17
    • 0344944261 scopus 로고    scopus 로고
    • Optimal allocation of heat-exchanger area for refrigeration and air-conditioning plants
    • L. Chen, F. Sun, and C. Wu Optimal allocation of heat-exchanger area for refrigeration and air-conditioning plants Appl. Energy 77 2004 339 354
    • (2004) Appl. Energy , vol.77 , pp. 339-354
    • Chen, L.1    Sun, F.2    Wu, C.3
  • 18
    • 0000900943 scopus 로고
    • Analysis of a vapor-compression refrigeration system with mechanical-subcooling
    • R.J. Couvillion, M.W. Larson, and M.H. Somerville Analysis of a vapor-compression refrigeration system with mechanical-subcooling ASHRAE Trans. 94 2 1988 641 659
    • (1988) ASHRAE Trans. , vol.94 , Issue.2 , pp. 641-659
    • Couvillion, R.J.1    Larson, M.W.2    Somerville, M.H.3
  • 19
    • 1142276326 scopus 로고    scopus 로고
    • Liquid-gas heat exchanger for household refrigerator
    • V. Dagilis, L. Vaitkus, and A. Balcius Liquid-gas heat exchanger for household refrigerator Int. J. Refrigeration 27 2004 235 241
    • (2004) Int. J. Refrigeration , vol.27 , pp. 235-241
    • Dagilis, V.1    Vaitkus, L.2    Balcius, A.3
  • 20
    • 0027867057 scopus 로고
    • Thermodynamic evaluation of R22 alternative refrigerants and refrigerant mixtures
    • P.A. Domanski, and D.A. Didion Thermodynamic evaluation of R22 alternative refrigerants and refrigerant mixtures ASHRAE Trans. 99 2 1993 636 648
    • (1993) ASHRAE Trans. , vol.99 , Issue.2 , pp. 636-648
    • Domanski, P.A.1    Didion, D.A.2
  • 21
    • 0028500616 scopus 로고
    • Evaluation of suction-line/liquid-line heat exchange in the refrigeration cycle
    • P.A. Domanski, D.A. Didion, and J.P. Doyle Evaluation of suction-line/liquid-line heat exchange in the refrigeration cycle Rev. Int. Froid 17 7 1994 487 493
    • (1994) Rev. Int. Froid , vol.17 , Issue.7 , pp. 487-493
    • Domanski, P.A.1    Didion, D.A.2    Doyle, J.P.3
  • 22
    • 1042275381 scopus 로고    scopus 로고
    • Optimization of thermal systems based on finite-time thermodynamics and thermoeconomics
    • A. Durmayaza, O.S. Sogut, B. Sahin, and H. Yavuz Optimization of thermal systems based on finite-time thermodynamics and thermoeconomics Prog. Energy Combust. Sci. 30 2004 175 217
    • (2004) Prog. Energy Combust. Sci. , vol.30 , pp. 175-217
    • Durmayaza, A.1    Sogut, O.S.2    Sahin, B.3    Yavuz, H.4
  • 23
    • 0032136278 scopus 로고    scopus 로고
    • Thermoeconomic analysis and diagnosis of a refrigeration plant
    • M.D. d'Accadia, and F. de Rossi Thermoeconomic analysis and diagnosis of a refrigeration plant Energy Convers. Manage 39 12 1998 1223 1232
    • (1998) Energy Convers. Manage , vol.39 , Issue.12 , pp. 1223-1232
    • D'Accadia, M.D.1    De Rossi, F.2
  • 25
    • 61749086941 scopus 로고    scopus 로고
    • Prediction of the energy consumption of household refrigerators and freezers via steady-state simulation
    • C.J.L. Hermes, C. Melo, F.T. Knabben, and J.M. Gonçalves Prediction of the energy consumption of household refrigerators and freezers via steady-state simulation Appl. Energy 86 7-8 2009 1311 1319
    • (2009) Appl. Energy , vol.86 , Issue.78 , pp. 1311-1319
    • Hermes, C.J.L.1    Melo, C.2    Knabben, F.T.3    Gonçalves, J.M.4
  • 27
    • 0033667696 scopus 로고    scopus 로고
    • Design and rating of dedicated mechanical subcooling vapor-compression refrigeration systems
    • J.R. Khan, and S.M. Zubair Design and rating of dedicated mechanical subcooling vapor-compression refrigeration systems Proc. IMechE - J. Power Energy 214 A5 2000 455 471
    • (2000) Proc. IMechE - J. Power Energy , vol.214 A5 , pp. 455-471
    • Khan, J.R.1    Zubair, S.M.2
  • 28
    • 0033899093 scopus 로고    scopus 로고
    • Design and rating of an integrated mechanical subcooling vapor-compression system
    • J.R. Khan, and S.M. Zubair Design and rating of an integrated mechanical subcooling vapor-compression system Energy Convers. Manage 41 11 2000 1201 1222
    • (2000) Energy Convers. Manage , vol.41 , Issue.11 , pp. 1201-1222
    • Khan, J.R.1    Zubair, S.M.2
  • 30
    • 0009102272 scopus 로고    scopus 로고
    • The relationship of optimum heat exchanger allocation and minimum entropy generation rate for refrigeration cycles
    • S.A. Klein, and D.T. Reindl The relationship of optimum heat exchanger allocation and minimum entropy generation rate for refrigeration cycles J. Energy Resour. Technol. 120 1998 172 178
    • (1998) J. Energy Resour. Technol. , vol.120 , pp. 172-178
    • Klein, S.A.1    Reindl, D.T.2
  • 31
    • 0034559492 scopus 로고    scopus 로고
    • Refrigeration system performance using liquid-suction heat exchangers
    • S.A. Klein, D.T. Reindl, and K. Brownell Refrigeration system performance using liquid-suction heat exchangers Int. J. Refrigeration 23 8 2000 588 596
    • (2000) Int. J. Refrigeration , vol.23 , Issue.8 , pp. 588-596
    • Klein, S.A.1    Reindl, D.T.2    Brownell, K.3
  • 32
    • 0000893593 scopus 로고    scopus 로고
    • Effects of internal irreversibility and heat leakage on the finite time thermoeconomic performance of refrigerators and heat pumps
    • A. Kodal, B. Sahin, and T. Yilmaz Effects of internal irreversibility and heat leakage on the finite time thermoeconomic performance of refrigerators and heat pumps Energy Convers. Manage 41 2000 607 619
    • (2000) Energy Convers. Manage , vol.41 , pp. 607-619
    • Kodal, A.1    Sahin, B.2    Yilmaz, T.3
  • 34
    • 84890566238 scopus 로고    scopus 로고
    • United Nations Framework Convention on Climate Change (UNFCCC) Kyoto, Japan
    • Kyoto Protocol Report of the Conference of the Parties 1997 United Nations Framework Convention on Climate Change (UNFCCC) Kyoto, Japan
    • (1997) Report of the Conference of the Parties
    • Protocol, K.1
  • 35
    • 0026984853 scopus 로고
    • Effect of condenser liquid subcooling on system performance for refrigerants CFC-12, HFC-134a, and HFC-152a
    • J.W. Linton, W.L. Snelson, and P.F. Hearty Effect of condenser liquid subcooling on system performance for refrigerants CFC-12, HFC-134a, and HFC-152a ASHRAE Trans. 68 2 1992 160 166
    • (1992) ASHRAE Trans. , vol.68 , Issue.2 , pp. 160-166
    • Linton, J.W.1    Snelson, W.L.2    Hearty, P.F.3
  • 36
    • 75149175050 scopus 로고    scopus 로고
    • Performance evaluation of R404A and R507A refrigerant mixtures in an experimental double-stage vapour compression plant
    • R. Llopis, E. Torrella, R. Cabello, and D. Sánchez Performance evaluation of R404A and R507A refrigerant mixtures in an experimental double-stage vapour compression plant Appl. Energy 87 2010 1546 1553
    • (2010) Appl. Energy , vol.87 , pp. 1546-1553
    • Llopis, R.1    Torrella, E.2    Cabello, R.3    Sánchez, D.4
  • 37
    • 34248353512 scopus 로고    scopus 로고
    • A chart for predicting the possible advantage of adopting a suction/liquid heat exchanger in refrigerating system
    • R. Mastrullo, A.W. Mauro, S. Tino, and G.P. Vanoli A chart for predicting the possible advantage of adopting a suction/liquid heat exchanger in refrigerating system Appl. Therm. Eng. 27 14-15 2007 2443 2448
    • (2007) Appl. Therm. Eng. , vol.27 , Issue.1415 , pp. 2443-2448
    • Mastrullo, R.1    Mauro, A.W.2    Tino, S.3    Vanoli, G.P.4
  • 42
    • 27644506642 scopus 로고    scopus 로고
    • Impact of fouling and cleaning on plate fin and spine fin heat exchanger performance
    • B.C. Pak, E.A. Groll, and J.E. Braun Impact of fouling and cleaning on plate fin and spine fin heat exchanger performance ASHRAE Trans. 111 1 2005 496 504
    • (2005) ASHRAE Trans. , vol.111 , Issue.1 , pp. 496-504
    • Pak, B.C.1    Groll, E.A.2    Braun, J.E.3
  • 44
    • 67349273775 scopus 로고    scopus 로고
    • Effects of biofouling on air-side heat transfer and pressure drop for finned tube heat exchangers
    • H. Pu, G. Ding, and X. Ma Effects of biofouling on air-side heat transfer and pressure drop for finned tube heat exchangers Int. J. Refrigeration 32 2009 1032 1040
    • (2009) Int. J. Refrigeration , vol.32 , pp. 1032-1040
    • Pu, H.1    Ding, G.2    Ma, X.3
  • 45
    • 79955884567 scopus 로고    scopus 로고
    • Performance degradation of a vapor compression refrigeration system under fouled conditions
    • B.A. Qureshi, and S.M. Zubair Performance degradation of a vapor compression refrigeration system under fouled conditions Int. J. Refrigeration 34 4 2011 1016 1027
    • (2011) Int. J. Refrigeration , vol.34 , Issue.4 , pp. 1016-1027
    • Qureshi, B.A.1    Zubair, S.M.2
  • 46
    • 84855269038 scopus 로고    scopus 로고
    • The impact of fouling on performance of a vapor compression refrigeration system with integrated mechanical sub-cooling
    • B.A. Qureshi, and S.M. Zubair The impact of fouling on performance of a vapor compression refrigeration system with integrated mechanical sub-cooling Appl. Energy 92 2012 750 762
    • (2012) Appl. Energy , vol.92 , pp. 750-762
    • Qureshi, B.A.1    Zubair, S.M.2
  • 47
    • 82955167948 scopus 로고    scopus 로고
    • The effect of refrigerant combinations on performance of a vapor compression refrigeration system with dedicated mechanical subcooling
    • B.A. Qureshi, and S.M. Zubair The effect of refrigerant combinations on performance of a vapor compression refrigeration system with dedicated mechanical subcooling Int. J. Refrigeration 35 1 2012 47 57
    • (2012) Int. J. Refrigeration , vol.35 , Issue.1 , pp. 47-57
    • Qureshi, B.A.1    Zubair, S.M.2
  • 48
    • 84877635410 scopus 로고    scopus 로고
    • Cost optimization of heat exchanger inventory for mechanical subcooling refrigeration cycles
    • B.A. Qureshi, and S.M. Zubair Cost optimization of heat exchanger inventory for mechanical subcooling refrigeration cycles Int. J. Refrigeration 36 4 2013 1243 1253
    • (2013) Int. J. Refrigeration , vol.36 , Issue.4 , pp. 1243-1253
    • Qureshi, B.A.1    Zubair, S.M.2
  • 49
    • 84870760403 scopus 로고    scopus 로고
    • Experimental energetic analysis of a vapor compression refrigeration system with dedicated mechanical sub-cooling
    • B.A. Qureshi, M. Inam, M.A. Antar, and S.M. Zubair Experimental energetic analysis of a vapor compression refrigeration system with dedicated mechanical sub-cooling Appl. Energy 102 2013 1035 1041
    • (2013) Appl. Energy , vol.102 , pp. 1035-1041
    • Qureshi, B.A.1    Inam, M.2    Antar, M.A.3    Zubair, S.M.4
  • 50
    • 0033148804 scopus 로고    scopus 로고
    • Finite time thermoeconomic optimization for endoreversible refrigerators and heat pumps
    • B. Sahin, and A. Kodal Finite time thermoeconomic optimization for endoreversible refrigerators and heat pumps Energy Convers. Manage 40 1999 951 960
    • (1999) Energy Convers. Manage , vol.40 , pp. 951-960
    • Sahin, B.1    Kodal, A.2
  • 51
    • 0036836311 scopus 로고    scopus 로고
    • Thermoeconomic optimization of a two stage combined refrigeration system: A finite-time approach
    • B. Sahin, and A. Kodal Thermoeconomic optimization of a two stage combined refrigeration system: a finite-time approach Int. J. Refrigeration 25 7 2002 872 877
    • (2002) Int. J. Refrigeration , vol.25 , Issue.7 , pp. 872-877
    • Sahin, B.1    Kodal, A.2
  • 52
    • 0035284252 scopus 로고    scopus 로고
    • Optimal performance characteristics of a two-stage irreversible combined refrigeration system under maximum cooling load per unit total cost conditions
    • B. Sahin, A. Kodal, and A. Koyun Optimal performance characteristics of a two-stage irreversible combined refrigeration system under maximum cooling load per unit total cost conditions Energy Convers. Manage 42 2001 451 465
    • (2001) Energy Convers. Manage , vol.42 , pp. 451-465
    • Sahin, B.1    Kodal, A.2    Koyun, A.3
  • 57
    • 0042587945 scopus 로고
    • Conserving energy in domestic refrigerators through the use of refrigerant mixtures
    • W.F. Stoecker, and D.J. Walukas Conserving energy in domestic refrigerators through the use of refrigerant mixtures ASHRAE Trans. 87 1 1981 279 281
    • (1981) ASHRAE Trans. , vol.87 , Issue.1 , pp. 279-281
    • Stoecker, W.F.1    Walukas, D.J.2
  • 58
    • 0028545509 scopus 로고
    • Dedicated mechanical-subcooling design strategies for supermarket applications
    • J.F. Thornton, S.A. Klein, and J.W. Mitchell Dedicated mechanical-subcooling design strategies for supermarket applications Int. J. Refrigeration 17 8 1994 508 515
    • (1994) Int. J. Refrigeration , vol.17 , Issue.8 , pp. 508-515
    • Thornton, J.F.1    Klein, S.A.2    Mitchell, J.W.3
  • 60
    • 75149167145 scopus 로고    scopus 로고
    • Experimental energetic analysis of the subcooler system in a two-stage refrigeration facility driven by a compound compressor
    • E. Torrella, R. Llopis, R. Cabello, and D. Sánchez Experimental energetic analysis of the subcooler system in a two-stage refrigeration facility driven by a compound compressor HVAC&R Res. 15 3 2009 583 596
    • (2009) HVAC&R Res. , vol.15 , Issue.3 , pp. 583-596
    • Torrella, E.1    Llopis, R.2    Cabello, R.3    Sánchez, D.4
  • 62
    • 80052267724 scopus 로고    scopus 로고
    • Simulation-based design and optimization of refrigeration cassettes
    • M. Waltrich, C.J.L. Hermes, and C. Melo Simulation-based design and optimization of refrigeration cassettes Appl. Energy 88 12 2011 4756 4765
    • (2011) Appl. Energy , vol.88 , Issue.12 , pp. 4756-4765
    • Waltrich, M.1    Hermes, C.J.L.2    Melo, C.3
  • 63
    • 78049458657 scopus 로고    scopus 로고
    • On subcooler design for integrated two-temperature supermarket refrigeration system
    • L. Yang, and C.-L. Zhang On subcooler design for integrated two-temperature supermarket refrigeration system Energy Build 43 2011 224 231
    • (2011) Energy Build , vol.43 , pp. 224-231
    • Yang, L.1    Zhang, C.-L.2
  • 64
    • 0027271476 scopus 로고
    • Super-subcooling with R12 and R22 refrigeration plants using reciprocating compressors
    • J. Zhang, W. Hu, and M.S.J. Hashmi Super-subcooling with R12 and R22 refrigeration plants using reciprocating compressors Appl. Energy 45 1993 157 166
    • (1993) Appl. Energy , vol.45 , pp. 157-166
    • Zhang, J.1    Hu, W.2    Hashmi, M.S.J.3
  • 65
    • 0025433245 scopus 로고
    • Improvement of refrigeration/air-conditioning performance with mechanical subcooling
    • S.M. Zubair Improvement of refrigeration/air-conditioning performance with mechanical subcooling Energy 15 5 1990 427 437
    • (1990) Energy , vol.15 , Issue.5 , pp. 427-437
    • Zubair, S.M.1
  • 66
    • 0028448633 scopus 로고
    • Thermodynamics of a vapor-compression refrigeration cycle with mechanical-subcooling
    • S.M. Zubair Thermodynamics of a vapor-compression refrigeration cycle with mechanical-subcooling Energy 19 1994 707 715
    • (1994) Energy , vol.19 , pp. 707-715
    • Zubair, S.M.1
  • 67
    • 0030290313 scopus 로고    scopus 로고
    • Second-law-based thermodynamic analysis of two-stage and mechanical-subcooling refrigeration cycles
    • S.M. Zubair, M. Yaqub, and S.H. Khan Second-law-based thermodynamic analysis of two-stage and mechanical-subcooling refrigeration cycles Int. J. Refrigeration 19 1996 506 516
    • (1996) Int. J. Refrigeration , vol.19 , pp. 506-516
    • Zubair, S.M.1    Yaqub, M.2    Khan, S.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.