메뉴 건너뛰기




Volumn 15, Issue 6, 2013, Pages 941-948

Enrichment of prostate cancer cells from blood cells with a hybrid dielectrophoresis and immunocapture microfluidic system

Author keywords

Circulating tumor cell; Dielectrophoresis; Enrichment; Immunocapture; Microfluidic; Prostate cancer

Indexed keywords

CIRCULATING TUMOR CELLS; IMMUNOCAPTURE; MICRO FLUIDIC SYSTEM; PERFORMANCE CRITERION; PERFORMANCE TRADE-OFF; PERIPHERAL BLOOD MONONUCLEAR CELLS; PROSTATE CANCER CELLS; PROSTATE CANCERS;

EID: 84890562225     PISSN: 13872176     EISSN: 15728781     Source Type: Journal    
DOI: 10.1007/s10544-013-9784-6     Document Type: Article
Times cited : (50)

References (39)
  • 4
    • 65949094358 scopus 로고    scopus 로고
    • Isolation of rare cells from cell mixtures by dielectrophoresis
    • 10.1002/elps.200800373
    • P.R.C. Gascoyne, J. Noshari, T.J. Anderson, F.F. Becker, Isolation of rare cells from cell mixtures by dielectrophoresis. Electrophor. 30(8), 1388-1398 (2009)
    • (2009) Electrophor. , vol.30 , Issue.8 , pp. 1388-1398
    • Gascoyne, P.R.C.1    Noshari, J.2    Anderson, T.J.3    Becker, F.F.4
  • 5
    • 77951922478 scopus 로고    scopus 로고
    • Capture of circulating tumor cells from whole blood of prostate cancer patients using geometrically enhanced differential immunocapture (GEDI) and a prostate-specific antibody
    • 10.1039/b917959c
    • J.P. Gleghorn, E.D. Pratt, D. Denning, H. Liu, N.H. Bander, S.T. Tagawa, D.M. Nanus, P.A. Giannakakou, B.J. Kirby, Capture of circulating tumor cells from whole blood of prostate cancer patients using geometrically enhanced differential immunocapture (GEDI) and a prostate-specific antibody. Lab Chip. 10(1), 27-29 (2010)
    • (2010) Lab Chip , vol.10 , Issue.1 , pp. 27-29
    • Gleghorn, J.P.1    Pratt, E.D.2    Denning, D.3    Liu, H.4    Bander, N.H.5    Tagawa, S.T.6    Nanus, D.M.7    Giannakakou, P.A.8    Kirby, B.J.9
  • 6
    • 84863194825 scopus 로고    scopus 로고
    • ApoStream, a new dielectrophoretic device for antibody independent isolation and recovery of viable cancer cells from blood
    • 10.1063/1.4731647
    • V. Gupta, I. Jafferji, M. Garza, V.O. Melnikova, D.K. Hasegawa, R. Pethig, D.W. Davis, ApoStream, a new dielectrophoretic device for antibody independent isolation and recovery of viable cancer cells from blood. Biomicrofluidics 6(2), 024,133 (2012)
    • (2012) Biomicrofluidics , vol.6 , Issue.2 , pp. 024
    • Gupta, V.1    Jafferji, I.2    Garza, M.3    Melnikova, V.O.4    Hasegawa, D.K.5    Pethig, R.6    Davis, D.W.7
  • 7
    • 84873651286 scopus 로고    scopus 로고
    • An electrorotation technique for measuring the dielectric properties of cells with simultaneous use of negative quadrupolar dielectrophoresis and electrorotation
    • 10.1039/c3an36261b
    • S.I. Han, Y.D. Joo, K.H. Han, An electrorotation technique for mea suring the dielectric properties of cells with simultaneous use of negative quadrupolar dielectrophoresis and electrorotation. The Anal. 138(5), 1529-1537 (2013)
    • (2013) The Anal , vol.138 , Issue.5 , pp. 1529-1537
    • Han, S.I.1    Joo, Y.D.2    Han, K.H.3
  • 8
    • 35349011005 scopus 로고    scopus 로고
    • Continuous-flow particle separation by 3D insulative dielectrophoresis using coherently shaped, dc-biased, ac electric fields
    • 10.1021/ac0707277
    • B.G. Hawkins, A.E. Smith, Y.A. Syed, B.J. Kirby, Continuous-flow particle separation by 3D insulative dielectrophoresis using coherently shaped, dc-biased, ac electric fields. Anal. Chem. 79(19), 7291-7300 (2007)
    • (2007) Anal. Chem. , vol.79 , Issue.19 , pp. 7291-7300
    • Hawkins, B.G.1    Smith, A.E.2    Syed, Y.A.3    Kirby, B.J.4
  • 10
    • 79955567398 scopus 로고    scopus 로고
    • Automated dielectrophoretic characterization of Mycobacterium smegmatis
    • 10.1021/ac2002017
    • B.G. Hawkins, C. Huang, S. Arasanipalai, B.J. Kirby, Automated dielectrophoretic characterization of Mycobacterium smegmatis. Anal. Chem. 83(9), 3507-3515 (2011)
    • (2011) Anal. Chem. , vol.83 , Issue.9 , pp. 3507-3515
    • Hawkins, B.G.1    Huang, C.2    Arasanipalai, S.3    Kirby, B.J.4
  • 11
    • 80052826003 scopus 로고    scopus 로고
    • Selective concentration of human cancer cells using contactless dielectrophoresis
    • 10.1002/elps.201100081
    • E.A. Henslee, M.B. Sano, A.D. Rojas, E.M. Schmelz, R.V. Davalos, Selective concentration of human cancer cells using contactless dielectrophoresis. Electrophoresis 32(18), 2523-2529 (2011)
    • (2011) Electrophoresis , vol.32 , Issue.18 , pp. 2523-2529
    • Henslee, E.A.1    Sano, M.B.2    Rojas, A.D.3    Schmelz, E.M.4    Davalos, R.V.5
  • 13
    • 84875805949 scopus 로고    scopus 로고
    • Microfluidic devices for the isolation of circulating rare cells: A focus on affinity-based, dielectrophoresis, and hydrophoresis
    • 10.1002/elps.201200417
    • K.A. Hyun, H.I. Jung, Microfluidic devices for the isolation of circulating rare cells: a focus on affinity-based, dielectrophoresis, and hydrophoresis. Electrophoresis. 34(7), 1028-1041 (2013)
    • (2013) Electrophoresis , vol.34 , Issue.7 , pp. 1028-1041
    • Hyun, K.A.1    Jung, H.I.2
  • 14
    • 84870250040 scopus 로고    scopus 로고
    • A microfabricated module for isolating cervical carcinoma cells from peripheral blood utilizing dielectrophoresis in stepping electric fields
    • 10.1007/s00542-012-1506-0
    • C.P. Jen, H.H. Chang, C.T. Huang, K.H. Chen, A microfabricated module for isolating cervical carcinoma cells from peripheral blood utilizing dielectrophoresis in stepping electric fields. Microsyst. Technol. 18(11), 1887-1896 (2012)
    • (2012) Microsyst. Technol. , vol.18 , Issue.11 , pp. 1887-1896
    • Jen, C.P.1    Chang, H.H.2    Huang, C.T.3    Chen, K.H.4
  • 19
    • 0030866116 scopus 로고    scopus 로고
    • Monoclonal antibodies to the extracellular domain of prostate-specific membrane antigen also react with tumor vascular endothelium
    • H. Liu, P. Moy, S. Kim, Y. Xia, A. Rajasekaran, V. Navarro, B. Knudsen, N.H. Bander, Monoclonal antibodies to the extracellular domain of prostate-specific membrane antigen also react with tumor vascular endothelium. Cancer Res. 57(17), 3629-3634 (1997)
    • (1997) Cancer Res. , vol.57 , Issue.17 , pp. 3629-3634
    • Liu, H.1    Moy, P.2    Kim, S.3    Xia, Y.4    Rajasekaran, A.5    Navarro, V.6    Knudsen, B.7    Bander, N.H.8
  • 21
    • 11144232321 scopus 로고    scopus 로고
    • Effect of flow and surface conditions on human lymphocyte isolation using microfluidic chambers
    • 10.1021/la048047b
    • S.K. Murthy, A. Sin, R.G. Tompkins, M. Toner, Effect of flow and surface conditions on human lymphocyte isolation using microfluidic chambers. Langmuir. 20(26), 11,649-11,655 (2004)
    • (2004) Langmuir , vol.20 , Issue.26 , pp. 11
    • Murthy, S.K.1    Sin, A.2    Tompkins, R.G.3    Toner, M.4
  • 28
    • 80755153729 scopus 로고    scopus 로고
    • Modeling and development of a low frequency contactless dielectrophoresis (cDEP) platform to sort cancer cells from dilute whole blood samples
    • 10.1016/j.bios.2011.07.048
    • M.B. Sano, J.L. Caldwell, R.V. Davalos, Modeling and development of a low frequency contactless dielectrophoresis (cDEP) platform to sort cancer cells from dilute whole blood samples. Biosens. Bioelectron. 30(1), 13-20 (2011a)
    • (2011) Biosens. Bioelectron. , vol.30 , Issue.1 , pp. 13-20
    • Sano, M.B.1    Caldwell, J.L.2    Davalos, R.V.3
  • 29
    • 81555205138 scopus 로고    scopus 로고
    • Contactless dielectrophoretic spectroscopy: Examination of the dielectric properties of cells found in blood
    • 10.1002/elps.201100351
    • M.B. Sano, E.A. Henslee, E. Schmelz, R.V. Davalos, Contactless dielectrophoretic spectroscopy: examination of the dielectric properties of cells found in blood. Electrophoresis 32(22), 3164-3171 (2011b)
    • (2011) Electrophoresis , vol.32 , Issue.22 , pp. 3164-3171
    • Sano, M.B.1    Henslee, E.A.2    Schmelz, E.3    Davalos, R.V.4
  • 30
    • 84861460223 scopus 로고    scopus 로고
    • Immunocapture of prostate cancer cells by use of anti-PSMA antibodies in microdevices
    • 10.1007/s10544-011-9616-5
    • S.M. Santana, H. Liu, N.H. Bander, J.P. Gleghorn, B.J. Kirby, Immunocapture of prostate cancer cells by use of anti-PSMA anti-bodies in microdevices. Biomed. Microdevices. 14(2), 401-407 (2012)
    • (2012) Biomed. Microdevices. , vol.14 , Issue.2 , pp. 401-407
    • Santana, S.M.1    Liu, H.2    Bander, N.H.3    Gleghorn, J.P.4    Kirby, B.J.5
  • 31
    • 84874688601 scopus 로고    scopus 로고
    • Dielectrophoresis has broad applicability to marker-free isolation of tumor cells from blood by microfluidic systems
    • S. Shim, K. Stemke-Hale, J. Noshari, F.F. Becker, P.R.C. Gascoyne, Dielectrophoresis has broad applicability to marker-free isolation of tumor cells from blood by microfluidic systems. Biomicrofluidics 7(1), 011,808 (2013a)
    • (2013) Biomicrofluidics , vol.7 , Issue.1 , pp. 011
    • Shim, S.1    Stemke-Hale, K.2    Noshari, J.3    Becker, F.F.4    Gascoyne, P.R.C.5
  • 33
    • 84868020069 scopus 로고    scopus 로고
    • Microfluidic transport in microdevices for rare cell capture
    • 10.1002/elps.201200263
    • J.P. Smith, A.C. Barbati, S.M. Santana, J.P. Gleghorn, B.J. Kirby, Microfluidic transport in microdevices for rare cell capture. Electrophoresis 33(21), 3133-3142 (2012)
    • (2012) Electrophoresis , vol.33 , Issue.21 , pp. 3133-3142
    • Smith, J.P.1    Barbati, A.C.2    Santana, S.M.3    Gleghorn, J.P.4    Kirby, B.J.5
  • 36
    • 0027333731 scopus 로고
    • Design and construction of a linear shear stress flow chamber
    • 10.1007/BF02368167
    • S. Usami, H.H. Chen, Y. Zhao, S. Chien, R. Skalak, Design and construction of a linear shear stress flow chamber. Ann. Biomed. Eng. 21(1), 77-83 (1993)
    • (1993) Ann. Biomed. Eng. , vol.21 , Issue.1 , pp. 77-83
    • Usami, S.1    Chen, H.H.2    Zhao, Y.3    Chien, S.4    Skalak, R.5
  • 37
    • 33748152342 scopus 로고    scopus 로고
    • Electrical forces for microscale cell manipulation
    • 10.1146/annurev.bioeng.8.061505.095739
    • J. Voldman, Electrical forces for microscale cell manipulation. Annu. Rev. Biomed. Eng. 8, 425-54 (2006)
    • (2006) Annu. Rev. Biomed. Eng. , vol.8 , pp. 425-454
    • Voldman, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.