Volumn 63, Issue 1, 2014, Pages 63-71

An improved model-based maximum power point tracker for photovoltaic panels

Author keywords

Energy efficiency; modeling; parameter estimation; photovoltaic (PV) cells; solar energy

Indexed keywords

ENVIRONMENTAL CONDITIONS; INCREMENTAL CONDUCTANCE ALGORITHM; INTEGRATED CONVERTERS; MAXIMUM POWER POINT; MAXIMUM POWER POINT TRACKER; PERTURB AND OBSERVE; PHOTOVOLTAIC; SWITCH-MODE POWER CONVERTERS;

EID: 84890557754     PISSN: 00189456     EISSN: None     Source Type: Journal    
DOI: 10.1109/TIM.2013.2277579     Document Type: Article
Times cited : (107)

References (31)
  • 1
    • 79957486576 scopus 로고    scopus 로고
    • A high-efficiency PV module-integrated DC/DC converter for PV energy harvest in FREEDM systems
    • Mar
    • Z. Liang, R. Guo, J. Li, and A. Q. Huang, "A high-efficiency PV module-integrated DC/DC converter for PV energy harvest in FREEDM systems," IEEE Trans. Power Electron., vol. 26, no. 3, pp. 897-909, Mar. 2011.
    • (2011) IEEE Trans. Power Electron , vol.26 , Issue.3 , pp. 897-909
    • Liang, Z.1    Guo, R.2    Li, J.3    Huang, A.Q.4
  • 2
    • 44449176527 scopus 로고    scopus 로고
    • A review of the single phase photovoltaic module integrated converter topologies with three different DC link configurations
    • DOI 10.1109/TPEL.2008.920883
    • Q. Li and P. Wolfs, "A review of the single phase photovoltaic module integrated converter topologies with three different DC link configurations," IEEE Trans. Power Electron., vol. 23, no. 3, pp. 1320-1333, May 2008. (Pubitemid 351756707)
    • (2008) IEEE Transactions on Power Electronics , vol.23 , Issue.3 , pp. 1320-1333
    • Li, Q.1    Wolfs, P.2
  • 5
    • 34249794869 scopus 로고    scopus 로고
    • Comparison of photovoltaic array maximum power point tracking techniques
    • DOI 10.1109/TEC.2006.874230
    • T. Esram and P. L. Chapman, "Comparison of photovoltaic array maximum power point tracking techniques," IEEE Trans. Energy Convers., vol. 22, no. 2, pp. 439-449, Jun. 2007. (Pubitemid 46845644)
    • (2007) IEEE Transactions on Energy Conversion , vol.22 , Issue.2 , pp. 439-449
    • Esram, T.1    Chapman, P.L.2
  • 6
    • 0037238083 scopus 로고    scopus 로고
    • Comparative study of maximum power point tracking algorithms
    • Jan
    • D. P. Hohm and M. E. Ropp, "Comparative study of maximum power point tracking algorithms," Progr. Photovolt., Res. Appl., vol. 11, no. 1, pp. 47-62, Jan. 2003.
    • (2003) Progr. Photovolt., Res. Appl. , vol.11 , Issue.1 , pp. 47-62
    • Hohm, D.P.1    Ropp, M.E.2
  • 7
    • 22944480226 scopus 로고    scopus 로고
    • Optimization of perturb and observe maximum power point tracking method
    • DOI 10.1109/TPEL.2005.850975
    • N. Femia, G. Petrone, G. Spagnuolo, and M. Vitelli, "Optimization of perturb and observe maximum power point tracking method," IEEE Trans. Power Electron., vol. 20, no. 4, pp. 963-973, Jul. 2005. (Pubitemid 41046704)
    • (2005) IEEE Transactions on Power Electronics , vol.20 , Issue.4 , pp. 963-973
    • Femia, N.1    Petrone, G.2    Spagnuolo, G.3    Vitelli, M.4
  • 8
    • 33748255517 scopus 로고    scopus 로고
    • Review of the maximum power point tracking algorithms for stand-alone photovoltaic systems
    • DOI 10.1016/j.solmat.2005.10.023, PII S0927024805003582
    • V. Salas, E. Olìas, A. Barrado, and A. Làzaro, "Review of the maximum power point tracking algorithms for stand-alone photovoltaic systems," Solar Energy Mater. Solar Cells, vol. 90, no. 11, pp. 1555-1578, Jan. 2006. (Pubitemid 44316531)
    • (2006) Solar Energy Materials and Solar Cells , vol.90 , Issue.11 , pp. 1555-1578
    • Salas, V.1    Olias, E.2    Barrado, A.3    Lazaro, A.4
  • 9
    • 70350743366 scopus 로고    scopus 로고
    • Improved photovoltaic MPPT algorithm adapted for unstable atmospheric conditions and partial shading
    • Jun
    • A. Zbeeb, V. Devabhaktuni, and A. Sebak, "Improved photovoltaic MPPT algorithm adapted for unstable atmospheric conditions and partial shading," in Proc. Int. Conf. Clean Electr. Power, Jun. 2009, pp. 320-323.
    • (2009) Proc. Int. Conf. Clean Electr. Power , pp. 320-323
    • Zbeeb, A.1    Devabhaktuni, V.2    Sebak, A.3
  • 11
    • 34548414498 scopus 로고    scopus 로고
    • On the testing, characterization, and evaluation of PV inverters and dynamic MPPT performance under real varying operating conditions
    • DOI 10.1002/pip.763
    • P. Sanchis, J. Lòpez, A. Ursùa, E. Gubìa, and L. Marroyo, "On the testing, characterization and evaluation of PV inverters and dynamic MPPT performance under real varying operating conditions," Progr. Photovolt., Res. Appl., vol. 15, no. 6, pp. 541-556, Sep. 2007. (Pubitemid 47359503)
    • (2007) Progress in Photovoltaics: Research and Applications , vol.15 , Issue.6 , pp. 541-556
    • Sanchis, P.1    Lopez, J.2    Ursua, A.3    Gubia, E.4    Marroyo, L.5
  • 12
    • 0035283787 scopus 로고    scopus 로고
    • Estimation of equivalent circuit parameters of PV module and its application to optimal operation of PV system
    • DOI 10.1016/S0927-0248(00)00307-X
    • T. Ikegami, T. Maezono, F. Nakanishi, Y. Yamagata, and K. Ebihara, "Estimation of equivalent circuit parameters of PV module and its application to optimal operation of PV system," Solar Energy Mater. Solar Cells, vol. 67, nos. 1-4, pp. 389-395, Mar. 2001. (Pubitemid 32092049)
    • (2001) Solar Energy Materials and Solar Cells , vol.67 , Issue.1-4 , pp. 389-395
    • Ikegami, T.1    Maezono, T.2    Nakanishi, F.3    Yamagata, Y.4    Ebihara, K.5
  • 13
    • 79955804843 scopus 로고    scopus 로고
    • A new method of MPPT control based on the model of photovoltaic array
    • Mar
    • W. Xiaolei, J. Huai-Zhen, Y. Liang, and Y. Pan, "A new method of MPPT control based on the model of photovoltaic array," in Proc. Power Energy Eng. Conf., Mar. 2011, pp. 1-3.
    • (2011) Proc. Power Energy Eng. Conf. , pp. 1-3
    • Xiaolei, W.1    Huai-Zhen, J.2    Liang, Y.3    Pan, Y.4
  • 14
    • 84866516329 scopus 로고    scopus 로고
    • A simple photovoltaic panel model: Characterization procedure and evaluation of the role of environmental measurements
    • Oct
    • L. Cristaldi, M. Faifer, F. Ponci, and M. Rossi, "A simple photovoltaic panel model: Characterization procedure and evaluation of the role of environmental measurements," IEEE Trans. Instrum. Meas., vol. 61, no. 10, pp. 2632-2641, Oct. 2012.
    • (2012) IEEE Trans. Instrum. Meas. , vol.61 , Issue.10 , pp. 2632-2641
    • Cristaldi, L.1    Faifer, M.2    Ponci, F.3    Rossi, M.4
  • 15
    • 0035173089 scopus 로고    scopus 로고
    • Evaluating MPPT converter topologies using a MATLAB PV model
    • G. Walker, "Evaluating MPPT converter topologies using a MATLAB PV model," J. Electr. Electron. Eng., vol. 21, no. 1, pp. 49-56, 2001
    • (2001) J. Electr. Electron. Eng. , vol.21 , Issue.1 , pp. 49-56
    • Walker, G.1
  • 16
  • 17
    • 78751641369 scopus 로고    scopus 로고
    • High-accuracy maximum power point estimation for photovoltaic arrays
    • Mar
    • J. C. Wang, Y. L. Su, J. C. Shieh, and J. A. Jiang, "High-accuracy maximum power point estimation for photovoltaic arrays," Solar Energy Mater. Solar Cells, vol. 95, no. 3, pp. 843-851, Mar. 2011.
    • (2011) Solar Energy Mater. Solar Cells , vol.95 , Issue.3 , pp. 843-851
    • Wang, J.C.1    Su, Y.L.2    Shieh, J.C.3    Jiang, J.A.4
  • 19
    • 82155195853 scopus 로고    scopus 로고
    • A new approach for solar module temperature estimation using the simple diode model
    • Dec
    • G. Farivar and B. Asaei, "A new approach for solar module temperature estimation using the simple diode model," IEEE Trans. Energy Convers., vol. 26, no. 4, pp. 1118-1124, Dec. 2011.
    • (2011) IEEE Trans. Energy Convers , vol.26 , Issue.4 , pp. 1118-1124
    • Farivar, G.1    Asaei, B.2
  • 20
    • 67349141404 scopus 로고    scopus 로고
    • Comprehensive approach to modeling and simulation of photovoltaic arrays
    • May
    • M. G. Villalva, J. R. Gazoli, and E. R. Filho, "Comprehensive approach to modeling and simulation of photovoltaic arrays," IEEE Trans. Power Electron., vol. 24, no. 5, pp. 1198-1208, May 2009.
    • (2009) IEEE Trans. Power Electron , vol.24 , Issue.5 , pp. 1198-1208
    • Villalva, M.G.1    Gazoli, J.R.2    Filho, E.R.3
  • 22
    • 8744241416 scopus 로고    scopus 로고
    • A novel modeling method for photovoltaic cells
    • Jun
    • W. Xiao, W. G. Dunford, and A. Capel, "A novel modeling method for photovoltaic cells," in Proc. IEEE 35th Annu. PESC, Jun. 2004, pp. 1950-1956.
    • (2004) Proc. IEEE 35th Annu. PESC , pp. 1950-1956
    • Xiao, W.1    Dunford, W.G.2    Capel, A.3
  • 24
    • 50249096178 scopus 로고    scopus 로고
    • A simple correlation for the operating temperature of photovoltaic modules of arbitrary mounting
    • Nov
    • E. Skoplaki, A. G. Boudouvis, and J. A. Palyvos, "A simple correlation for the operating temperature of photovoltaic modules of arbitrary mounting," Solar Energy Mater. Solar Cells, vol. 92, no. 11, pp. 1393-1402, Nov. 2008.
    • (2008) Solar Energy Mater. Solar Cells , vol.92 , Issue.11 , pp. 1393-1402
    • Skoplaki, E.1    Boudouvis, A.G.2    Palyvos, J.A.3
  • 25
    • 79955482295 scopus 로고    scopus 로고
    • Modeling of the nominal operating cell temperature based on outdoor weathering
    • Feb
    • M. Koehl, M. Heck, S. Wiesmeier, and J. Wirth, "Modeling of the nominal operating cell temperature based on outdoor weathering," Solar Energy Mater. Solar Cells, vol. 95, no. 7, pp. 1638-1646, Feb. 2011.
    • (2011) Solar Energy Mater. Solar Cells , vol.95 , Issue.7 , pp. 1638-1646
    • Koehl, M.1    Heck, M.2    Wiesmeier, S.3    Wirth, J.4
  • 26
    • 78149357812 scopus 로고    scopus 로고
    • Outdoor testing of PV module temperature and performance under different mounting and operational conditions
    • Jan
    • J. Kurnik, M. Jankovec, K. Brecl, and M. Topic, "Outdoor testing of PV module temperature and performance under different mounting and operational conditions," Solar Energy Mater. Solar Cells, vol. 95, no. 1, pp. 373-376, Jan. 2011.
    • (2011) Solar Energy Mater. Solar Cells , vol.95 , Issue.1 , pp. 373-376
    • Kurnik, J.1    Jankovec, M.2    Brecl, K.3    Topic, M.4
  • 28
    • 2942616620 scopus 로고    scopus 로고
    • Estimation of photovoltaic module yearly temperature and performance based on Nominal Operation Cell Temperature calculations
    • DOI 10.1016/j.renene.2004.03.010, PII S0960148104001260
    • M. C. Alonso García and J. L. Balenzategui, "Estimation of photovoltaic module yearly temperature and performance based on nominal operation cell temperature calculations," Renew. Energy, vol. 29, no. 12, pp. 1997-2010, Oct. 2004. (Pubitemid 38763551)
    • (2004) Renewable Energy , vol.29 , Issue.12 , pp. 1997-2010
    • Alonso Garcia, M.C.1    Balenzategui, J.L.2
  • 29
    • 78650149453 scopus 로고    scopus 로고
    • Novel method and system for monitoring CPV cell and module temperature
    • Jun
    • D. A. Adkins, "Novel method and system for monitoring CPV cell and module temperature," in Proc. 35th IEEE PVSC, Jun. 2010, pp. 1660-1665.
    • (2010) Proc. 35th IEEE PVSC , pp. 1660-1665
    • Adkins, D.A.1
  • 31
    • 84890554198 scopus 로고    scopus 로고
    • FVG Energy LTD. London U.K Photovoltaic Module FVG 72-125-180M690 MC, [Online]. Available
    • FVG Energy LTD. London, U.K. (2010). Photovoltaic Module FVG 72-125-180M690 MC, [Online]. Available: http://www.fvgenergy.com
    • (2010)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.