메뉴 건너뛰기




Volumn 30, Issue 24, 2013, Pages 2051-2056

Use of brain electrical activity for the identification of hematomas in mild traumatic brain injury

Author keywords

hematoma; mild traumatic brain injury; neuroimaging; quantitative EEG

Indexed keywords

ADULT; AGED; ARTICLE; BRAIN BLOOD VOLUME; BRAIN HEMATOMA; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; ELECTRODE; ELECTROENCEPHALOGRAM; EPIDURAL HEMATOMA; FALSE NEGATIVE RESULT; FEMALE; GLASGOW COMA SCALE; HUMAN; MALE; MENTAL HEALTH; NEUROIMAGING; PREDICTIVE VALUE; RETROSPECTIVE STUDY; SUBARACHNOID HEMORRHAGE; SUBDURAL HEMATOMA; TRAUMATIC BRAIN INJURY; UNCONSCIOUSNESS;

EID: 84890524563     PISSN: 08977151     EISSN: 15579042     Source Type: Journal    
DOI: 10.1089/neu.2013.3062     Document Type: Article
Times cited : (12)

References (13)
  • 2
    • 77956675505 scopus 로고    scopus 로고
    • Use of brain electrical activity to quantify traumatic brain injury in the emergency department
    • Naunheim, R.S., Treaster, M., English, J., Casner, T., and Chabot, R. (2010). Use of brain electrical activity to quantify traumatic brain injury in the emergency department. Brain Inj. 24, 1324-1329.
    • (2010) Brain Inj , vol.24 , pp. 1324-1329
    • Naunheim, R.S.1    Treaster, M.2    English, J.3    Casner, T.4    Chabot, R.5
  • 3
    • 84872557363 scopus 로고    scopus 로고
    • Quantitative brain electrical activity in the initial screening of mild traumatic brain injuries
    • ONeil, B., Naunheim, R.S., Prichep, L.S., and Chabot, R.J. (2012). Quantitative brain electrical activity in the initial screening of mild traumatic brain injuries. West. J. Emerg. Med. 13, 394-400.
    • (2012) West. J. Emerg. Med , vol.13 , pp. 394-400
    • Oneil, B.1    Naunheim, R.S.2    Prichep, L.S.3    Chabot, R.J.4
  • 4
    • 33845750049 scopus 로고    scopus 로고
    • The accuracy of near-infrared spectroscopy in detection of subdural and epidural hematomas
    • Kahraman, S., Kayali, H., Atabey, C., Acar, F., and Gocmen, S. (2006). The accuracy of near-infrared spectroscopy in detection of subdural and epidural hematomas. J. Trauma 61, 1480-1483.
    • (2006) J. Trauma , vol.61 , pp. 1480-1483
    • Kahraman, S.1    Kayali, H.2    Atabey, C.3    Acar, F.4    Gocmen, S.5
  • 6
    • 77955884344 scopus 로고    scopus 로고
    • The Infrascanner, a handheld device for screening in situ for the presence of brain haematomas
    • Leon-Carrion, J., Dominguez-Roldan, J.M., Leon-Dominguez, U., and Murillo-Cabezas, F. (2010). The Infrascanner, a handheld device for screening in situ for the presence of brain haematomas. Brain Inj. 24, 1193-1201.
    • (2010) Brain Inj , vol.24 , pp. 1193-1201
    • Leon-Carrion, J.1    Dominguez-Roldan, J.M.2    Leon-Dominguez, U.3    Murillo-Cabezas, F.4
  • 8
    • 0002545849 scopus 로고    scopus 로고
    • Assessment of capacity to give consent to research participation: State-of-The-art and beyond
    • DeRenzo, E.G., Conley, R.R., and Love, R. (1998). Assessment of capacity to give consent to research participation: state-of-The-art and beyond. J. Health Care Law Policy 1, 66-87.
    • (1998) J. Health Care Law Policy , vol.1 , pp. 66-87
    • Derenzo, E.G.1    Conley, R.R.2    Love, R.3
  • 9
    • 15044352366 scopus 로고    scopus 로고
    • OsiriX: An open-source software for navigating in multidimensional DICOM images
    • Rosset, A., Spadola, L., and Ratib, O. (2004). OsiriX: An open-source software for navigating in multidimensional DICOM images. J. Digit. Imaging 17, 205-216.
    • (2004) J. Digit. Imaging , vol.17 , pp. 205-216
    • Rosset, A.1    Spadola, L.2    Ratib, O.3
  • 11
    • 0024281187 scopus 로고
    • Neurometrics: Computer-assisted differential diagnosis of brain dysfunctions
    • John, E.R., Prichep, L.S., Friedman, J., and Easton, P. (1988). Neurometrics: Computer-assisted differential diagnosis of brain dysfunctions. Science 293, 162-169.
    • (1988) Science , vol.293 , pp. 162-169
    • John, E.R.1    Prichep, L.S.2    Friedman, J.3    Easton, P.4
  • 13
    • 84890524613 scopus 로고    scopus 로고
    • U.S. Food Drug Administration Center for Devices and Radiological Health Class III Designation Petition (de novo) K080377 classification order
    • U.S. Food and Drug Administration, Center for Devices and Radiological Health. Infrascanner Model 1000, Evaluation of Automatic Class III Designation Petition (de novo) K080377 classification order. 2011.
    • (2011) Infrascanner Model 1000 Evaluation of Automatic


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.