메뉴 건너뛰기




Volumn 39, Issue 1, 2014, Pages 217-223

Fat fraction bias correction using T1 estimates and flip angle mapping

Author keywords

fat quantification; flip angle map; T1 bias correction

Indexed keywords

ACCURACY; ARTICLE; HUMAN; IMAGE ANALYSIS; IMAGE RECONSTRUCTION; NORMAL HUMAN; PRIORITY JOURNAL; PROTON DENSITY FAT FRACTION; RADIOLOGICAL PROCEDURES; SIGNAL NOISE RATIO; SPECTROSCOPY; SUBCUTANEOUS FAT;

EID: 84890487151     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.24126     Document Type: Article
Times cited : (21)

References (22)
  • 1
    • 0030464315 scopus 로고    scopus 로고
    • MRI in the evaluation of late bone marrow changes following bone marrow transplantation
    • et al.
    • Tanner SF, Clarke J, Leach MO, et al. MRI in the evaluation of late bone marrow changes following bone marrow transplantation. Br J Radiol 1996; 69: 1145-1151.
    • (1996) Br J Radiol , vol.69 , pp. 1145-1151
    • Tanner, S.F.1    Clarke, J.2    Leach, M.O.3
  • 2
    • 0031227305 scopus 로고    scopus 로고
    • The role of MRI in the valuation of disorders involving the bone marrow
    • Gualdi GF, Di Biasi C, Serafini G, Casciani E,. [The role of MRI in the valuation of disorders involving the bone marrow.] Clin Ter 1997; 148: 407-417.
    • (1997) Clin ter , vol.148 , pp. 407-417
    • Gualdi, G.F.1    Di Biasi, C.2    Serafini, G.3    Casciani, E.4
  • 3
    • 0031134558 scopus 로고    scopus 로고
    • Bone marrow MRI in hematological disorders
    • Heshiki A,. [Bone marrow MRI in hematological disorders.] Rinsho Ketsueki 1997; 38: 345-348.
    • (1997) Rinsho Ketsueki , vol.38 , pp. 345-348
    • Heshiki, A.1
  • 4
    • 0027476634 scopus 로고
    • Leukemic red bone marrow changes assessed by magnetic resonance imaging and localized 1H spectroscopy
    • et al.
    • Schick F, Einsele H, Bongers H, et al. Leukemic red bone marrow changes assessed by magnetic resonance imaging and localized 1H spectroscopy. Ann Hematol 1993; 66: 3-13.
    • (1993) Ann Hematol , vol.66 , pp. 3-13
    • Schick, F.1    Einsele, H.2    Bongers, H.3
  • 5
    • 0029020854 scopus 로고
    • Magnetic resonance imaging of femoral marrow in patients with myelodysplastic syndromes or leukemia
    • Takagi S, Tanaka O, Miura Y,. Magnetic resonance imaging of femoral marrow in patients with myelodysplastic syndromes or leukemia. Blood 1995; 86: 316-322.
    • (1995) Blood , vol.86 , pp. 316-322
    • Takagi, S.1    Tanaka, O.2    Miura, Y.3
  • 7
    • 0030761160 scopus 로고    scopus 로고
    • Magnetic resonance imaging of the bone marrow in hematologic malignancies
    • Moulopoulos LA, Dimopoulos MA,. Magnetic resonance imaging of the bone marrow in hematologic malignancies. Blood 1997; 90: 2127-2147.
    • (1997) Blood , vol.90 , pp. 2127-2147
    • Moulopoulos, L.A.1    Dimopoulos, M.A.2
  • 8
    • 84867834721 scopus 로고    scopus 로고
    • Proton density fat-fraction: A standardized MR-based biomarker of tissue fat concentration
    • Reeder SB, Hu HH, Sirlin CB,. Proton density fat-fraction: a standardized MR-based biomarker of tissue fat concentration. J Magn Reson Imaging 2012; 36: 1011-1014.
    • (2012) J Magn Reson Imaging , vol.36 , pp. 1011-1014
    • Reeder, S.B.1    Hu, H.H.2    Sirlin, C.B.3
  • 9
    • 35148862772 scopus 로고    scopus 로고
    • Multiecho reconstruction for simultaneous water-fat decomposition and T2* estimation
    • et al.
    • Yu H, McKenzie CA, Shimakawa A, et al. Multiecho reconstruction for simultaneous water-fat decomposition and T2* estimation. J Magn Reson Imaging 2007; 26: 1153-1161.
    • (2007) J Magn Reson Imaging , vol.26 , pp. 1153-1161
    • Yu, H.1    McKenzie, C.A.2    Shimakawa, A.3
  • 10
    • 78649278546 scopus 로고    scopus 로고
    • Quantification of liver fat with magnetic resonance imaging
    • Reeder SB, Sirlin CB,. Quantification of liver fat with magnetic resonance imaging. Magn Reson Imaging Clin N Am 2010; 18: 337-357, ix.
    • (2010) Magn Reson Imaging Clin N Am , vol.18 , pp. 337-357
    • Reeder, S.B.1    Sirlin, C.B.2
  • 12
    • 80054815132 scopus 로고    scopus 로고
    • T(1)-corrected fat quantification using chemical shift-based water/fat separation: Application to skeletal muscle
    • Karampinos DC, Yu H, Shimakawa A, Link TM, Majumdar S,. T(1)-corrected fat quantification using chemical shift-based water/fat separation: application to skeletal muscle. Magn Reson Med 2011; 66: 1312-1326.
    • (2011) Magn Reson Med , vol.66 , pp. 1312-1326
    • Karampinos, D.C.1    Yu, H.2    Shimakawa, A.3    Link, T.M.4    Majumdar, S.5
  • 13
    • 34547934476 scopus 로고    scopus 로고
    • Fat quantification with IDEAL gradient echo imaging: Correction of bias from T(1) and noise
    • Liu CY, McKenzie CA, Yu H, Brittain JH, Reeder SB,. Fat quantification with IDEAL gradient echo imaging: correction of bias from T(1) and noise. Magn Reson Med 2007; 58: 354-364.
    • (2007) Magn Reson Med , vol.58 , pp. 354-364
    • Liu, C.Y.1    McKenzie, C.A.2    Yu, H.3    Brittain, J.H.4    Reeder, S.B.5
  • 14
    • 1342330052 scopus 로고    scopus 로고
    • MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: Preliminary results
    • de Bazelaire CM, Duhamel GD, Rofsky NM, Alsop DC,. MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: preliminary results. Radiology 2004; 230: 652-659.
    • (2004) Radiology , vol.230 , pp. 652-659
    • De Bazelaire, C.M.1    Duhamel, G.D.2    Rofsky, N.M.3    Alsop, D.C.4
  • 16
    • 0037370514 scopus 로고    scopus 로고
    • Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state
    • Deoni SC, Rutt BK, Peters TM,. Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state. Magn Reson Med 2003; 49: 515-526.
    • (2003) Magn Reson Med , vol.49 , pp. 515-526
    • Deoni, S.C.1    Rutt, B.K.2    Peters, T.M.3
  • 17
    • 84890484008 scopus 로고    scopus 로고
    • B1 Correction using dual tau Look-Locker (DLL)
    • Honolulu; (abstract 573)
    • Wade T, Rutt B,. B1 Correction using dual tau Look-Locker (DLL). In: Proc 17th Annual Meeting ISMRM, Honolulu; 2009 (abstract 573).
    • (2009) Proc 17th Annual Meeting ISMRM
    • Wade, T.1    Rutt, B.2
  • 19
    • 70350462793 scopus 로고    scopus 로고
    • T1 independent, T2* corrected MRI with accurate spectral modeling for quantification of fat: Validation in a fat-water-SPIO phantom
    • Hines CD, Yu H, Shimakawa A, McKenzie CA, Brittain JH, Reeder SB,. T1 independent, T2* corrected MRI with accurate spectral modeling for quantification of fat: validation in a fat-water-SPIO phantom. J Magn Reson Imaging 2009; 30: 1215-1222.
    • (2009) J Magn Reson Imaging , vol.30 , pp. 1215-1222
    • Hines, C.D.1    Yu, H.2    Shimakawa, A.3    McKenzie, C.A.4    Brittain, J.H.5    Reeder, S.B.6
  • 20
    • 12144259379 scopus 로고    scopus 로고
    • Magnetic resonance spectroscopy to measure hepatic triglyceride content: Prevalence of hepatic steatosis in the general population
    • et al.
    • Szczepaniak LS, Nurenberg P, Leonard D, et al. Magnetic resonance spectroscopy to measure hepatic triglyceride content: prevalence of hepatic steatosis in the general population. Am J Physiol Endocrinol Metab 2005; 288: E462-468.
    • (2005) Am J Physiol Endocrinol Metab , vol.288
    • Szczepaniak, L.S.1    Nurenberg, P.2    Leonard, D.3
  • 21
    • 0032802545 scopus 로고    scopus 로고
    • Factors affecting the quantification of short echo in-vivo 1H MR spectra: Prior knowledge, peak elimination, and filtering
    • Bartha R, Drost DJ, Williamson PC,. Factors affecting the quantification of short echo in-vivo 1H MR spectra: prior knowledge, peak elimination, and filtering. NMR Biomed 1999; 12: 205-216.
    • (1999) NMR Biomed , vol.12 , pp. 205-216
    • Bartha, R.1    Drost, D.J.2    Williamson, P.C.3
  • 22
    • 80052964159 scopus 로고    scopus 로고
    • Computationally rapid method of estimating signal-to-noise ratio for phased array image reconstructions
    • Wiens CN, Kisch SJ, Willig-Onwuachi JD, McKenzie CA,. Computationally rapid method of estimating signal-to-noise ratio for phased array image reconstructions. Magn Reson Med 2011; 66: 1192-1197.
    • (2011) Magn Reson Med , vol.66 , pp. 1192-1197
    • Wiens, C.N.1    Kisch, S.J.2    Willig-Onwuachi, J.D.3    McKenzie, C.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.