메뉴 건너뛰기




Volumn 193, Issue , 2014, Pages 212-219

Amperometric determination of hydroquinone and catechol on gold electrode modified by direct electrodeposition of poly(3,4-ethylenedioxythiophene)

Author keywords

Catechol; Chronoamperometry; Cyclic voltammetry; Hydroquinone; Poly(3,4 ethylenedioxythiophene)

Indexed keywords

AMPEROMETRIC DETERMINATION; CATECHOL; HYDROQUINONE; MODIFIED ELECTRODES; OPTIMIZED CONDITIONS; PHOSPHATE BUFFER SOLUTIONS; POLY(3 ,4 ETHYLENEDIOXYTHIOPHENE) (PEDOT); POLY-3 ,4-ETHYLENEDIOXYTHIOPHENE;

EID: 84890476257     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2013.11.055     Document Type: Article
Times cited : (48)

References (49)
  • 1
    • 77950629575 scopus 로고    scopus 로고
    • Analysis of hydroquinone and catechol in peripheral blood of benzene-exposed workers
    • P. Kerzic, W. Liu, M. Pan, H. Fu, Y. Zhou, and A. Schnatter Analysis of hydroquinone and catechol in peripheral blood of benzene-exposed workers Chem. Biol. Interact. 184 2010 182 188
    • (2010) Chem. Biol. Interact. , vol.184 , pp. 182-188
    • Kerzic, P.1    Liu, W.2    Pan, M.3    Fu, H.4    Zhou, Y.5    Schnatter, A.6
  • 2
    • 78649987211 scopus 로고    scopus 로고
    • A voltammetric sensor based on graphene-modified electrode for simultaneous determination of catechol and hydroquinone
    • H.J. Du, J.S. Ye, J.Q. Zhang, X.D. Huang, and C.Z. Yu A voltammetric sensor based on graphene-modified electrode for simultaneous determination of catechol and hydroquinone J. Electroanal. Chem. 650 2011 209 213
    • (2011) J. Electroanal. Chem. , vol.650 , pp. 209-213
    • Du, H.J.1    Ye, J.S.2    Zhang, J.Q.3    Huang, X.D.4    Yu, C.Z.5
  • 3
    • 33644825907 scopus 로고    scopus 로고
    • Simultaneous determination of positional isomers of benzenediols by capillary zone electrophoresis with square wave amperometric detection
    • T.Y. Xie, Q.W. Liu, Y.R. Shi, and Q.Y. Liu Simultaneous determination of positional isomers of benzenediols by capillary zone electrophoresis with square wave amperometric detection J. Chromatogr. A 1109 2006 317 321
    • (2006) J. Chromatogr. A , vol.1109 , pp. 317-321
    • Xie, T.Y.1    Liu, Q.W.2    Shi, Y.R.3    Liu, Q.Y.4
  • 4
    • 77649313251 scopus 로고    scopus 로고
    • Simultaneous determination of hydroquinone and catechol at an activated glassy carbon electrode
    • A. Ahammad, S. Sarker, M.A. Rahman, and J.J. Lee Simultaneous determination of hydroquinone and catechol at an activated glassy carbon electrode Electroanalysis 22 2010 694 700
    • (2010) Electroanalysis , vol.22 , pp. 694-700
    • Ahammad, A.1    Sarker, S.2    Rahman, M.A.3    Lee, J.J.4
  • 5
    • 84871778601 scopus 로고    scopus 로고
    • Facile preparation of polydopamine-reduced graphene oxide nanocomposite and its electrochemical application in simultaneous determination of hydroquinone and catechol
    • L.Z. Zheng, L.Y. Xiong, Y.D. Li, J.P. Xu, X.W. Kang, Z.J. Zou, S.M. Yang, and J. Xia Facile preparation of polydopamine-reduced graphene oxide nanocomposite and its electrochemical application in simultaneous determination of hydroquinone and catechol Sens. Actuators B 177 2013 344 349
    • (2013) Sens. Actuators B , vol.177 , pp. 344-349
    • Zheng, L.Z.1    Xiong, L.Y.2    Li, Y.D.3    Xu, J.P.4    Kang, X.W.5    Zou, Z.J.6    Yang, S.M.7    Xia, J.8
  • 6
    • 33745003897 scopus 로고    scopus 로고
    • Determination of phenol, resorcinol and hydroquinone in air samples by synchronous fluorescence using partial least-squares (PLS)
    • DOI 10.1016/j.talanta.2005.12.050, PII S0039914006000154
    • M. Pistonesi, M. Di Nezio, M. Centurión, M. Palomeque, A. Lista, and B. Fernández Band Determination of phenol, resorcinol and hydroquinone in air samples by synchronous fluorescence using partial least-squares (PLS) Talanta 69 2006 1265 1268 (Pubitemid 43866182)
    • (2006) Talanta , vol.69 , Issue.5 , pp. 1265-1268
    • Pistonesi, M.F.1    Di Nezio, M.S.2    Centurion, M.E.3    Palomeque, M.E.4    Lista, A.G.5    Fernandez Band, B.S.6
  • 7
    • 33745241873 scopus 로고    scopus 로고
    • Chemiluminescence of cerium(IV)-rhodamine 6G-phenolic compound system
    • H. Cui, Q.L. Zhang, A. Myint, X.W. Ge, and L.J. Liu Chemiluminescence of cerium(IV)-rhodamine 6G-phenolic compound system J. Photochem. Photobiol. A 181 2006 238 245
    • (2006) J. Photochem. Photobiol. A , vol.181 , pp. 238-245
    • Cui, H.1    Zhang, Q.L.2    Myint, A.3    Ge, X.W.4    Liu, L.J.5
  • 8
    • 0013052882 scopus 로고    scopus 로고
    • Indirect kinetic-spectrophotometric determination of resorcinol, catechol, and hydroquinone
    • A. Afkhami, and H. Khatami Indirect kinetic-spectrophotometric determination of resorcinol, catechol, and hydroquinone J. Anal. Chem. 56 2001 429 432 (Pubitemid 33751857)
    • (2001) Journal of Analytical Chemistry , vol.56 , Issue.5 , pp. 429-432
    • Afkhami, A.1    Khatami, H.A.2
  • 9
    • 34249892216 scopus 로고    scopus 로고
    • Direct automatic determination of bitterness and total phenolic compounds in virgin olive oil using a pH-based flow-injection analysis system
    • DOI 10.1021/jf070235v
    • J. Garcia-Mesa, and R. Mateos Direct automatic determination of bitterness and total phenolic compounds in virgin olive oil using a pH-based flow-injection analysis system J. Agric. Food Chem. 55 2007 3863 3868 (Pubitemid 46867390)
    • (2007) Journal of Agricultural and Food Chemistry , vol.55 , Issue.10 , pp. 3863-3868
    • Garcia-Mesa, J.A.1    Mateos, R.2
  • 10
    • 79957659645 scopus 로고    scopus 로고
    • Development and optimization of a method for the analysis of phenols and chlorophenols from aqueous samples by gas chromatography-mass spectrometry, after solid-phase extraction and trimethylsilylation
    • A. Kovács, M. Mórtl, and A. Kende Development and optimization of a method for the analysis of phenols and chlorophenols from aqueous samples by gas chromatography-mass spectrometry, after solid-phase extraction and trimethylsilylation Microchem. J. 99 2011 125 131
    • (2011) Microchem. J. , vol.99 , pp. 125-131
    • Kovács, A.1    Mórtl, M.2    Kende, A.3
  • 11
    • 46449116236 scopus 로고    scopus 로고
    • Pulse radiolysis studies on reactions of hydroxyl radicals with selenocystine derivatives
    • B. Mishra, L. Kumbhare, V. Jain, and K. Priyadarsini Pulse radiolysis studies on reactions of hydroxyl radicals with selenocystine derivatives J. Phys. Chem. B 112 2008 4441 4446
    • (2008) J. Phys. Chem. B , vol.112 , pp. 4441-4446
    • Mishra, B.1    Kumbhare, L.2    Jain, V.3    Priyadarsini, K.4
  • 12
    • 43049097489 scopus 로고    scopus 로고
    • Use of acetonitrile for the extraction of dihydric phenols from salt aqueous solutions followed by HPLC determination
    • DOI 10.1134/S1061934808050110
    • E. Podolina, O. Rudakov, E. Khorokhordina, and L. Kharitonova Use of acetonitrile for the extraction of dihydric phenols from salt aqueous solutions followed by HPLC determination J. Anal. Chem. 63 2008 468 471 (Pubitemid 351630709)
    • (2008) Journal of Analytical Chemistry , vol.63 , Issue.5 , pp. 468-471
    • Podolina, E.A.1    Rudakov, O.B.2    Khorokhordina, E.A.3    Kharitonova, L.A.4
  • 13
    • 80955178922 scopus 로고    scopus 로고
    • Fast and sensitive high performance liquid chromatography analysis of cosmetic creams for hydroquinone, phenol and six preservatives
    • W.H. Gao, and C. Legido-Quigley Fast and sensitive high performance liquid chromatography analysis of cosmetic creams for hydroquinone, phenol and six preservatives J. Chromatogr. A 1218 2011 4307 4311
    • (2011) J. Chromatogr. A , vol.1218 , pp. 4307-4311
    • Gao, W.H.1    Legido-Quigley, C.2
  • 14
    • 77952880880 scopus 로고    scopus 로고
    • Electrochemical determination of diphenols and their mixtures at the multiwall carbon nanotubes/poly(3-methylthiophene) modified glassy carbon electrode
    • H. Zhang, J.S. Zhao, H.T. Liu, R.M. Liu, H.S. Wang, and J.F. Liu Electrochemical determination of diphenols and their mixtures at the multiwall carbon nanotubes/poly(3-methylthiophene) modified glassy carbon electrode Microchim. Acta 169 2010 277 282
    • (2010) Microchim. Acta , vol.169 , pp. 277-282
    • Zhang, H.1    Zhao, J.S.2    Liu, H.T.3    Liu, R.M.4    Wang, H.S.5    Liu, J.F.6
  • 15
    • 11444260930 scopus 로고    scopus 로고
    • Direct simultaneous determination of dihydroxybenzene isomers at C-nanotube-modified electrodes by derivative voltammetry
    • Y.P. Ding, W.L. Liu, Q.S. Wu, and X.G. Wang Direct simultaneous determination of dihydroxybenzene isomers at C-nanotube-modified electrodes by derivative voltammetry J. Electroanal. Chem. 575 2005 275 280
    • (2005) J. Electroanal. Chem. , vol.575 , pp. 275-280
    • Ding, Y.P.1    Liu, W.L.2    Wu, Q.S.3    Wang, X.G.4
  • 16
    • 20444477617 scopus 로고    scopus 로고
    • Simultaneous determination of hydroquinone and catechol at a glassy carbon electrode modified with multiwall carbon nanotubes
    • H.L. Qi, and C.X. Zhang Simultaneous determination of hydroquinone and catechol at a glassy carbon electrode modified with multiwall carbon nanotubes Electroanalysis 17 2005 832 838
    • (2005) Electroanalysis , vol.17 , pp. 832-838
    • Qi, H.L.1    Zhang, C.X.2
  • 17
    • 0041629054 scopus 로고    scopus 로고
    • Simultaneous determination of ascorbic acid, dopamine and serotonin at poly(phenosafranine) modified electrode
    • T. Selvaraju, and R. Ramaraj Simultaneous determination of ascorbic acid, dopamine and serotonin at poly(phenosafranine) modified electrode Electrochem. Commun. 5 2003 667 672
    • (2003) Electrochem. Commun. , vol.5 , pp. 667-672
    • Selvaraju, T.1    Ramaraj, R.2
  • 18
    • 84880854062 scopus 로고    scopus 로고
    • Direct simultaneous electrochemical determination of hydroquinone and catechol at a poly(glutamic acid) modified glassy carbon electrode
    • L. Wang, P.F. Huang, J.Y. Bai, H.J. Wang, L.Y. Zhang, and Y.Q. Zhao Direct simultaneous electrochemical determination of hydroquinone and catechol at a poly(glutamic acid) modified glassy carbon electrode Int. J. Electrochem. Sci. 2 2007 123 132
    • (2007) Int. J. Electrochem. Sci. , vol.2 , pp. 123-132
    • Wang, L.1    Huang, P.F.2    Bai, J.Y.3    Wang, H.J.4    Zhang, L.Y.5    Zhao, Y.Q.6
  • 20
    • 34247363120 scopus 로고    scopus 로고
    • Covalent modification of a glassy carbon electrode with penicillamine for simultaneous determination of hydroquinone and catechol
    • L. Wang, P.F. Huang, J.Y. Bai, H.J. Wang, L.Y. Zhang, and Y.Q. Zhao Covalent modification of a glassy carbon electrode with penicillamine for simultaneous determination of hydroquinone and catechol Microchim. Acta 158 2007 151 157
    • (2007) Microchim. Acta , vol.158 , pp. 151-157
    • Wang, L.1    Huang, P.F.2    Bai, J.Y.3    Wang, H.J.4    Zhang, L.Y.5    Zhao, Y.Q.6
  • 21
    • 79551569576 scopus 로고    scopus 로고
    • Direct electrodeposition of reduced graphene oxide on glassy carbon electrode and its electrochemical application
    • L.Y. Chen, Y.H. Tang, K. Wang, C.B. Liu, and S.L. Luo Direct electrodeposition of reduced graphene oxide on glassy carbon electrode and its electrochemical application Electrochem. Commun. 13 2011 133 137
    • (2011) Electrochem. Commun. , vol.13 , pp. 133-137
    • Chen, L.Y.1    Tang, Y.H.2    Wang, K.3    Liu, C.B.4    Luo, S.L.5
  • 22
    • 0035839083 scopus 로고    scopus 로고
    • Electrochemical oxidation of phenol at boron-doped diamond electrode
    • DOI 10.1016/S0013-4686(01)00630-2, PII S0013468601006302
    • J. Iniesta, P. Michaud, M. Panizza, G. Cerisola, A. Aldaz, and C. Comninellis Electrochemical oxidation of phenol at boron-doped diamond electrode Electrochim. Acta 46 2001 3573 3578 (Pubitemid 32771087)
    • (2001) Electrochimica Acta , vol.46 , Issue.23 , pp. 3573-3578
    • Iniesta, J.1    Michaud, P.A.2    Panizza, M.3    Cerisola, G.4    Aldaz, A.5    Comninellis, Ch.6
  • 23
    • 77954932456 scopus 로고    scopus 로고
    • Simultaneous determination of dihydroxybenzene isomers using disposable screen-printed electrode modified by multiwalled carbon nanotubes and gold nanoparticles
    • D.W. Li, Y.T. Li, W. Song, and Y.T. Long Simultaneous determination of dihydroxybenzene isomers using disposable screen-printed electrode modified by multiwalled carbon nanotubes and gold nanoparticles Anal. Methods 2 2010 837 843
    • (2010) Anal. Methods , vol.2 , pp. 837-843
    • Li, D.W.1    Li, Y.T.2    Song, W.3    Long, Y.T.4
  • 24
    • 70349279868 scopus 로고    scopus 로고
    • Simultaneous determination of hydroquinone and catechol at PASA/MWNTs composite film modified glassy carbon electrode
    • D.M. Zhao, X.H. Zhang, L.J. Feng, L. Jia, and S.F. Wang Simultaneous determination of hydroquinone and catechol at PASA/MWNTs composite film modified glassy carbon electrode Colloids Surf. B 74 2009 317 321
    • (2009) Colloids Surf. B , vol.74 , pp. 317-321
    • Zhao, D.M.1    Zhang, X.H.2    Feng, L.J.3    Jia, L.4    Wang, S.F.5
  • 25
    • 67649994025 scopus 로고    scopus 로고
    • Simultaneous determination of hydroquinone and catechol using poly(p-aminobenzoic acid) modified glassy carbon electrode
    • P. Yang, Q.Y. Zhu, Y.H. Chen, and F.W. Wang Simultaneous determination of hydroquinone and catechol using poly(p-aminobenzoic acid) modified glassy carbon electrode J. Appl. Polym. Sci. 113 2009 2881 2886
    • (2009) J. Appl. Polym. Sci. , vol.113 , pp. 2881-2886
    • Yang, P.1    Zhu, Q.Y.2    Chen, Y.H.3    Wang, F.W.4
  • 26
    • 78649255716 scopus 로고    scopus 로고
    • Electrocatalytic response of hydroquinone and catechol at polyglycine modified glassy carbon electrode
    • L. Wang, P.F. Huang, H.J. Wang, J.Y. Bai, L.Y. Zhang, and Y.Q. Zhao Electrocatalytic response of hydroquinone and catechol at polyglycine modified glassy carbon electrode Int. J. Electrochem. Sci. 2 2007 216 225
    • (2007) Int. J. Electrochem. Sci. , vol.2 , pp. 216-225
    • Wang, L.1    Huang, P.F.2    Wang, H.J.3    Bai, J.Y.4    Zhang, L.Y.5    Zhao, Y.Q.6
  • 27
    • 41549150618 scopus 로고    scopus 로고
    • Conducting polymers in chemical sensors and arrays
    • U. Lange, N. Roznyatovskaya, and V. Mirsky Conducting polymers in chemical sensors and arrays Anal. Chim. Acta 614 2008 1 26
    • (2008) Anal. Chim. Acta , vol.614 , pp. 1-26
    • Lange, U.1    Roznyatovskaya, N.2    Mirsky, V.3
  • 28
    • 79956348632 scopus 로고    scopus 로고
    • Highly sensitive and simultaneous determination of hydroquinone and catechol at poly(thionine) modified glassy carbon electrode
    • M. Mahbubur Rahman, A.J. Saleh Ahammad, G.R. Xu, S. Kim, and J.-J. Lee Highly sensitive and simultaneous determination of hydroquinone and catechol at poly(thionine) modified glassy carbon electrode Electrochim. Acta 56 2011 5266 5271
    • (2011) Electrochim. Acta , vol.56 , pp. 5266-5271
    • Mahbubur Rahman, M.1    Saleh Ahammad, A.J.2    Xu, G.R.3    Kim, S.4    Lee, J.-J.5
  • 29
    • 84863089717 scopus 로고    scopus 로고
    • Polyaniline/polysulfone composite film electrode for simultaneous determination of hydroquinone and catechol
    • X.J. Feng, Y.L. Shi, and Z.A. Hu Polyaniline/polysulfone composite film electrode for simultaneous determination of hydroquinone and catechol Mater. Chem. Phys. 131 2011 72 76
    • (2011) Mater. Chem. Phys. , vol.131 , pp. 72-76
    • Feng, X.J.1    Shi, Y.L.2    Hu, Z.A.3
  • 30
    • 0037142225 scopus 로고    scopus 로고
    • Chloroform vapour sensor based on copper/polyaniline nanocomposite
    • DOI 10.1016/S0925-4005(02)00064-3, PII S0925400502000643
    • S. Sharma, C. Nirkhe, S. Pethkar, and A.A. Athawale Chloroform vapour sensor based on copper/polyaniline nanocomposite Sens. Actuators B 85 2002 131 136 (Pubitemid 34614138)
    • (2002) Sensors and Actuators, B: Chemical , vol.85 , Issue.1-2 , pp. 131-136
    • Sharma, S.1    Nirkhe, C.2    Pethkar, S.3    Athawale, A.A.4
  • 31
    • 33751322656 scopus 로고    scopus 로고
    • Hydrogen sensors based on conductivity changes in polyaniline nanofibers
    • DOI 10.1021/jp063166g
    • S. Virji, R.B. Kaner, and B.H. Weiller Hydrogen sensors based on conductivity changes in polyaniline nanofibers J. Phys. Chem. B 110 2006 22266 22270 (Pubitemid 44806951)
    • (2006) Journal of Physical Chemistry B , vol.110 , Issue.44 , pp. 22266-22270
    • Virji, S.1    Kaner, R.B.2    Weiller, B.H.3
  • 33
    • 77955416127 scopus 로고    scopus 로고
    • Screen-printed poly(3,4-ethylenedioxythiophene) (PEDOT): A new electrochemical mediator for acetylcholinesterase-based biosensors
    • G. Istamboulie, T. Sikora, E. Jubete, E. Ochoteco, J.-L. Marty, and T. Noguer Screen-printed poly(3,4-ethylenedioxythiophene) (PEDOT): a new electrochemical mediator for acetylcholinesterase-based biosensors Talanta 82 2010 957 961
    • (2010) Talanta , vol.82 , pp. 957-961
    • Istamboulie, G.1    Sikora, T.2    Jubete, E.3    Ochoteco, E.4    Marty, J.-L.5    Noguer, T.6
  • 34
    • 44249086445 scopus 로고    scopus 로고
    • Electrochemical capacitance of the composite of poly(3,4- ethylenedioxythiophene) and functionalized single-walled carbon nanotubes
    • J. Wang, Y.L. Xu, X.F. Sun, X.F. Li, and X.F. Du Electrochemical capacitance of the composite of poly(3,4-ethylenedioxythiophene) and functionalized single-walled carbon nanotubes J. Solid State Electrochem. 12 2008 947 952
    • (2008) J. Solid State Electrochem. , vol.12 , pp. 947-952
    • Wang, J.1    Xu, Y.L.2    Sun, X.F.3    Li, X.F.4    Du, X.F.5
  • 35
    • 65849403631 scopus 로고    scopus 로고
    • Electrochemical co-polymerization of a novel fluorene derivative with 3,4-ethylenedioxythiophene
    • B. Bezgin, A. Yagan, and A.M. Onal Electrochemical co-polymerization of a novel fluorene derivative with 3,4-ethylenedioxythiophene J. Electroanal. Chem. 632 2009 143 148
    • (2009) J. Electroanal. Chem. , vol.632 , pp. 143-148
    • Bezgin, B.1    Yagan, A.2    Onal, A.M.3
  • 36
    • 33747145199 scopus 로고    scopus 로고
    • Electrochemical sensors based on conducting polymer-polypyrrole
    • DOI 10.1016/j.electacta.2005.11.052, PII S0013468606003252, ChargeTransfer at Electrochemical Interfaces Two Hundred Years of Electrlysis
    • A. Ramanavičius, A. Ramanavičienė, and A. Malinauskas Electrochemical sensors based on conducting polymer - polypyrrole Electrochim. Acta 51 2006 6025 6037 (Pubitemid 44223449)
    • (2006) Electrochimica Acta , vol.51 , Issue.27 , pp. 6025-6037
    • Ramanavicius, A.1    Ramanaviciene, A.2    Malinauskas, A.3
  • 37
    • 18844371199 scopus 로고    scopus 로고
    • 3,4-Ethylenedioxythiophene (EDOT) as a versatile building block for advanced functional -conjugated systems
    • DOI 10.1039/b415481a
    • J. Roncali, P. Blanchard, and P. Frère 3,4-Ethylenedioxythiophene (EDOT) as a versatile building block for advanced functional π-conjugated systems J. Mater. Chem. 15 2005 1589 1610 (Pubitemid 40679082)
    • (2005) Journal of Materials Chemistry , vol.15 , Issue.16 , pp. 1589-1610
    • Roncali, J.1    Blanchard, P.2    Frere, P.3
  • 38
    • 77949654361 scopus 로고    scopus 로고
    • Electrochemical synthesis of polyaniline in surface-attached poly(acrylic acid) network, and its application to the electrocatalytic oxidation of ascorbic acid
    • Y.H. Tang, K.X. Pan, X.J. Wang, C.B. Liu, and S.L. Luo Electrochemical synthesis of polyaniline in surface-attached poly(acrylic acid) network, and its application to the electrocatalytic oxidation of ascorbic acid Microchim. Acta 168 2010 231 237
    • (2010) Microchim. Acta , vol.168 , pp. 231-237
    • Tang, Y.H.1    Pan, K.X.2    Wang, X.J.3    Liu, C.B.4    Luo, S.L.5
  • 40
    • 59849112936 scopus 로고    scopus 로고
    • Synthesis and electrochemical capacitance of core-shell poly(3,4-ethylenedioxythiophene)/poly(sodium 4-styrenesulfonate)-modified multiwalled carbon nanotube nanocomposites
    • L. Chen, C.Z. Yuan, H. Dou, B. Gao, S.Y. Chen, and X.G. Zhang Synthesis and electrochemical capacitance of core-shell poly(3,4-ethylenedioxythiophene)/ poly(sodium 4-styrenesulfonate)-modified multiwalled carbon nanotube nanocomposites Electrochim. Acta 54 2009 2335 2341
    • (2009) Electrochim. Acta , vol.54 , pp. 2335-2341
    • Chen, L.1    Yuan, C.Z.2    Dou, H.3    Gao, B.4    Chen, S.Y.5    Zhang, X.G.6
  • 41
    • 79954618966 scopus 로고    scopus 로고
    • Direct and simple electrochemical determination of morphine at PEDOT modified Pt electrode
    • N. Atta, A. Galal, and R. Ahmed Direct and simple electrochemical determination of morphine at PEDOT modified Pt electrode Electroanalysis 23 2011 737 746
    • (2011) Electroanalysis , vol.23 , pp. 737-746
    • Atta, N.1    Galal, A.2    Ahmed, R.3
  • 42
    • 67349176042 scopus 로고    scopus 로고
    • Detection of nitrite using poly(3,4-ethylenedioxythiophene) modified SPCEs
    • C.Y. Lin, V.S. Vasantha, and K.C. Ho Detection of nitrite using poly(3,4-ethylenedioxythiophene) modified SPCEs Sens. Actuators B 140 2009 51 57
    • (2009) Sens. Actuators B , vol.140 , pp. 51-57
    • Lin, C.Y.1    Vasantha, V.S.2    Ho, K.C.3
  • 43
    • 68749113989 scopus 로고    scopus 로고
    • Molecularly imprinted conducting polymer based electrochemical sensor for detection of atrazine
    • E. Pardieu, H. Cheap, C. Vedrine, M. Lazerges, Y. Lattach, and F. Garnier Molecularly imprinted conducting polymer based electrochemical sensor for detection of atrazine Anal. Chim. Acta 649 2009 236 245
    • (2009) Anal. Chim. Acta , vol.649 , pp. 236-245
    • Pardieu, E.1    Cheap, H.2    Vedrine, C.3    Lazerges, M.4    Lattach, Y.5    Garnier, F.6
  • 44
    • 77956393593 scopus 로고    scopus 로고
    • Copper-modified poly(3,4-ethylenedioxythiophene) layers for selective determination of dopamine in the presence of ascorbic acid: II. Role of the characteristics of the metal deposit
    • A. Stoyanova, and V. Tsakova Copper-modified poly(3,4- ethylenedioxythiophene) layers for selective determination of dopamine in the presence of ascorbic acid: II. Role of the characteristics of the metal deposit J. Solid State Chem. 14 2010 1957 1965
    • (2010) J. Solid State Chem. , vol.14 , pp. 1957-1965
    • Stoyanova, A.1    Tsakova, V.2
  • 45
    • 77955466197 scopus 로고    scopus 로고
    • Voltammetric microsensor using PEDOT-modified gold electrode for the simultaneous assay of ascorbic and uric acids
    • F. Sekli-Belaidi, P. Temple-Boyer, and P. Gros Voltammetric microsensor using PEDOT-modified gold electrode for the simultaneous assay of ascorbic and uric acids J. Electroanal. Chem. 647 2010 159 168
    • (2010) J. Electroanal. Chem. , vol.647 , pp. 159-168
    • Sekli-Belaidi, F.1    Temple-Boyer, P.2    Gros, P.3
  • 46
    • 79953658568 scopus 로고    scopus 로고
    • Sensitive simultaneous determination of catechol and hydroquinone using a gold electrode modified with carbon nanofibers and gold nanoparticles
    • Z.H. Huo, Y.L. Zhou, Q. Liu, X.L. He, Y. Liang, and M.T. Xu Sensitive simultaneous determination of catechol and hydroquinone using a gold electrode modified with carbon nanofibers and gold nanoparticles Microchim. Acta 173 2011 119 125
    • (2011) Microchim. Acta , vol.173 , pp. 119-125
    • Huo, Z.H.1    Zhou, Y.L.2    Liu, Q.3    He, X.L.4    Liang, Y.5    Xu, M.T.6
  • 47
    • 84862776798 scopus 로고    scopus 로고
    • Simultaneous determination of catechol and hydroquinone using electrospun carbon nanofibers modified electrode
    • Q.H. Guo, J.S. Huang, P.Q. Chen, Y. Liu, H.Q. Hou, and T.Y. You Simultaneous determination of catechol and hydroquinone using electrospun carbon nanofibers modified electrode Sens. Actuators B 163 2012 179 185
    • (2012) Sens. Actuators B , vol.163 , pp. 179-185
    • Guo, Q.H.1    Huang, J.S.2    Chen, P.Q.3    Liu, Y.4    Hou, H.Q.5    You, T.Y.6
  • 48
    • 84870564137 scopus 로고    scopus 로고
    • Simultaneous determination of catechol and hydroquinone by carbon paste electrode modified with hydrophobic ionic liquid-functionalized SBA-15
    • S.Y. Dong, P.H. Zhang, Z. Yang, and T.L. Huang Simultaneous determination of catechol and hydroquinone by carbon paste electrode modified with hydrophobic ionic liquid-functionalized SBA-15 J. Solid State Chem. 16 2012 3861 3868
    • (2012) J. Solid State Chem. , vol.16 , pp. 3861-3868
    • Dong, S.Y.1    Zhang, P.H.2    Yang, Z.3    Huang, T.L.4
  • 49
    • 84862180211 scopus 로고    scopus 로고
    • Simultaneous determination of hydroquinone, catechol, resorcinol and nitrite using gold nanoparticles loaded on poly-3-amino-5-mercapto-1,2,4- triazole-MWNTs film modified electrode
    • C. Wang, R. Yuan, Y.Q. Chai, and F.X. Hu Simultaneous determination of hydroquinone, catechol, resorcinol and nitrite using gold nanoparticles loaded on poly-3-amino-5-mercapto-1,2,4-triazole-MWNTs film modified electrode Anal. Methods 4 2012 1626 1628
    • (2012) Anal. Methods , vol.4 , pp. 1626-1628
    • Wang, C.1    Yuan, R.2    Chai, Y.Q.3    Hu, F.X.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.