메뉴 건너뛰기




Volumn 28, Issue 11, 2013, Pages 2851-2859

Predicting mortality in haemodialysis patients: A comparison between lung ultrasonography, bioimpedance data and echocardiography parameters

Author keywords

Bioimpedance; Haemodialysis; Hydration status; Mortality; Ultrasound lung comets

Indexed keywords

ADULT; ARTICLE; BIOIMPEDANCE SPECTROSCOPY; CLINICAL EVALUATION; DEMOGRAPHY; DISEASE ASSOCIATION; DISEASE SEVERITY; ECHOCARDIOGRAPHY; ECHOGRAPHY; FEMALE; FOLLOW UP; HEART LEFT VENTRICLE MASS; HEMODIALYSIS PATIENT; HUMAN; HYDRATION; INTERMETHOD COMPARISON; LUNG CONGESTION; LUNG EXTRAVASCULAR FLUID; LUNG ULTRASONOGRAPHY; MAJOR CLINICAL STUDY; MALE; MIDDLE AGED; MORTALITY; OBSERVATIONAL STUDY; PREDICTION; PRIORITY JOURNAL; PROGNOSIS; SPECTROSCOPY; SURVIVAL RATE; SURVIVAL TIME; TOTAL BODY WATER;

EID: 84890073623     PISSN: 09310509     EISSN: 14602385     Source Type: Journal    
DOI: 10.1093/ndt/gft260     Document Type: Article
Times cited : (105)

References (24)
  • 1
    • 0242441465 scopus 로고    scopus 로고
    • Kidney disease as a risk factor for development of cardiovascular disease: A statement from the American Heart Association Councils on Kidney in Cardiovascular Disease, High Blood Pressure Research, Clinical Cardiology, and Epidemiology and Prevention
    • Sarnak MJ, Levey AS, Schoolwerth AC et al. Kidney disease as a risk factor for development of cardiovascular disease: a statement from the American Heart Association Councils on Kidney in Cardiovascular Disease, High Blood Pressure Research, Clinical Cardiology, and Epidemiology and Prevention. Hypertension 2003; 42: 1050-1065
    • (2003) Hypertension , vol.42 , pp. 1050-1065
    • Sarnak, M.J.1    Levey, A.S.2    Schoolwerth, A.C.3
  • 2
    • 33845807146 scopus 로고    scopus 로고
    • KDOQI clinical practice guidelines and clinical practice recommendations for 2006 updates: Hemodialysis adequacy, peritoneal dialysis adequacy and vascular access
    • KDOQI Clinical Practice Guidelines and Clinical Practice Recommendations for 2006 Updates: Hemodialysis Adequacy, Peritoneal Dialysis Adequacy and Vascular Access. Am J Kidney Dis 2006; 48(suppl 1): S1-S322 (see https://www.kidney.org/ professionals/kdoqi/guideline-upHD-PD-VA/disclaim.htm)
    • (2006) Am J Kidney Dis , vol.48 , Issue.SUPPL. 1
  • 3
    • 33745852282 scopus 로고    scopus 로고
    • Chronic kidney disease and mortality risk: A systematic review
    • Tonelli M,Wiebe N, Culleton B et al. Chronic kidney disease and mortality risk: a systematic review. J Am Soc Nephrol 2006; 17: 2034-2047
    • (2006) J Am Soc Nephrol , vol.17 , pp. 2034-2047
    • Tonelli, M.1    Wiebe, N.2    Culleton, B.3
  • 4
    • 0035173903 scopus 로고    scopus 로고
    • Interdialytic weight gain and dry weight
    • Levin NW, Zhu F, Keen M. Interdialytic weight gain and dry weight. Blood Purif 2001; 19: 217-221
    • (2001) Blood Purif , vol.19 , pp. 217-221
    • Levin, N.W.1    Zhu, F.2    Keen, M.3
  • 5
    • 0032936433 scopus 로고    scopus 로고
    • Assessment of dry weight in hemodialysis: An overview
    • Jaeger JQ, Mehta RL. Assessment of dry weight in hemodialysis: an overview. J Am Soc Nephrol 1999; 10: 392-403
    • (1999) J Am Soc Nephrol , vol.10 , pp. 392-403
    • Jaeger, J.Q.1    Mehta, R.L.2
  • 6
    • 84960600145 scopus 로고
    • Echography of the inferior vena cava is a simple and reliable tool for estimation of 'dry weight' in haemodialysis patients
    • Cheriex EC, Leunissen KML, Janssen JHA et al. Echography of the inferior vena cava is a simple and reliable tool for estimation of 'dry weight' in haemodialysis patients. Nephrol Dial Transplant 1989; 4: 563-568
    • (1989) Nephrol Dial Transplant , vol.4 , pp. 563-568
    • Cheriex, E.C.1    Leunissen, K.M.L.2    Janssen, J.H.A.3
  • 7
    • 74949132021 scopus 로고    scopus 로고
    • Relative plasma volume monitoring during hemodialysis aids the assessment of dry weight
    • Sinha AD, Light RP, Agarwal R. Relative plasma volume monitoring during hemodialysis aids the assessment of dry weight. Hypertension 2010; 55: 305-311
    • (2010) Hypertension , vol.55 , pp. 305-311
    • Sinha, A.D.1    Light, R.P.2    Agarwal, R.3
  • 8
    • 45749102253 scopus 로고    scopus 로고
    • Validation of a 3C model for determination of body fat mass
    • Moissl U, Bosaeus I, Lemmey A. Validation of a 3C model for determination of body fat mass. J Am Soc Nephrol 2007; 18: 257A
    • (2007) J Am Soc Nephrol , vol.18
    • Moissl, U.1    Bosaeus, I.2    Lemmey, A.3
  • 9
    • 65249173419 scopus 로고    scopus 로고
    • The mortality risk of overhydration in haemodialysis patients
    • Wizemann V, Wabel P, Chamney P et al. The mortality risk of overhydration in haemodialysis patients. Nephrol Dial Transplant 2009; 24: 1574-1579
    • (2009) Nephrol Dial Transplant , vol.24 , pp. 1574-1579
    • Wizemann, V.1    Wabel, P.2    Chamney, P.3
  • 10
    • 84890084603 scopus 로고    scopus 로고
    • Importance of normohydration for the long-term survival of haemodialysis patients
    • Chazot C, Wabel P, Chamney P et al. Importance of normohydration for the long-term survival of haemodialysis patients. Nephrol Dial Transplant 2011; 0: 1-7
    • (2011) Nephrol Dial Transplant , vol.0 , pp. 1-7
    • Chazot, C.1    Wabel, P.2    Chamney, P.3
  • 12
    • 33750946165 scopus 로고    scopus 로고
    • The pulmonary artery catheter in critical care
    • McGee WT, Mailloux P, Jodka P et al. The pulmonary artery catheter in critical care. Semin Dial 2006; 19: 480-491
    • (2006) Semin Dial , vol.19 , pp. 480-491
    • McGee, W.T.1    Mailloux, P.2    Jodka, P.3
  • 13
    • 77950353970 scopus 로고    scopus 로고
    • Why, when, and how to assess pulmonary congestion in heart failure: Pathophysiological, clinical, and methodological implications
    • Picano E, Gargani L, Gheorghiade M. Why, when, and how to assess pulmonary congestion in heart failure: pathophysiological, clinical, and methodological implications. Heart Fail Rev 2010; 15: 63-72
    • (2010) Heart Fail Rev , vol.15 , pp. 63-72
    • Picano, E.1    Gargani, L.2    Gheorghiade, M.3
  • 14
    • 2342536902 scopus 로고    scopus 로고
    • Usefulness of ultrasound lung comets as a nonradiologic sign of extravascular lung water
    • Jambrik Z, Monti S, Coppola V et al. Usefulness of ultrasound lung comets as a nonradiologic sign of extravascular lung water. Am J Cardiol 2004; 93: 1265-1270
    • (2004) Am J Cardiol , vol.93 , pp. 1265-1270
    • Jambrik, Z.1    Monti, S.2    Coppola, V.3
  • 15
    • 66649118306 scopus 로고    scopus 로고
    • Ultrasound assessment for extravascular lung water in patients undergoing hemodialysis
    • Noble VE, Murray AF, Capp R et al. Ultrasound assessment for extravascular lung water in patients undergoing hemodialysis. Time course for resolution. Chest 2009; 135: 1433-1439
    • (2009) Time Course for Resolution. Chest , vol.135 , pp. 1433-1439
    • Noble, V.E.1    Murray, A.F.2    Capp, R.3
  • 16
    • 77956684371 scopus 로고    scopus 로고
    • Detection of pulmonary congestion by chest ultrasound in dialysis patients
    • Mallamaci F, Benedetto FA, Tripepi R et al. Detection of pulmonary congestion by chest ultrasound in dialysis patients. JACC Cardiovasc Imaging 2010; 3: 586-594
    • (2010) JACC Cardiovasc Imaging , vol.3 , pp. 586-594
    • Mallamaci, F.1    Benedetto, F.A.2    Tripepi, R.3
  • 17
    • 84875703534 scopus 로고    scopus 로고
    • Pulmonary congestion predicts cardiac events and mortality in ESRD
    • Zoccali C, Torino C, Tripepi R et al. Pulmonary congestion predicts cardiac events and mortality in ESRD. J Am Soc Nephrol 2013; 24: 639-646
    • (2013) J Am Soc Nephrol , vol.24 , pp. 639-646
    • Zoccali, C.1    Torino, C.2    Tripepi, R.3
  • 18
    • 33144470740 scopus 로고    scopus 로고
    • Ultrasound lung comets: A clinically useful sign of extravascular lung water
    • Picano E, Frassi F, Agricola E et al. Ultrasound lung comets: a clinically useful sign of extravascular lung water. J Am Soc Echocardiogr 2006; 19: 356-363
    • (2006) J Am Soc Echocardiogr , vol.19 , pp. 356-363
    • Picano, E.1    Frassi, F.2    Agricola, E.3
  • 19
    • 33746557390 scopus 로고    scopus 로고
    • Body fluid volume determination via body composition spectroscopy in health and disease
    • Moissl UM, Wabel P, Chamney PW et al. Body fluid volume determination via body composition spectroscopy in health and disease. Physiol Meas 2006; 27: 921-933
    • (2006) Physiol Meas , vol.27 , pp. 921-933
    • Moissl, U.M.1    Wabel, P.2    Chamney, P.W.3
  • 20
    • 58549120372 scopus 로고    scopus 로고
    • Towards improved cardiovascular management: The necessity of combining blood pressure and fluid overload
    • Wabel P, Moissl U, Chamney P et al. Towards improved cardiovascular management: the necessity of combining blood pressure and fluid overload. Nephrol Dial Transplant 2008; 9: 2965-2971
    • (2008) Nephrol Dial Transplant , vol.9 , pp. 2965-2971
    • Wabel, P.1    Moissl, U.2    Chamney, P.3
  • 21
    • 29244432482 scopus 로고    scopus 로고
    • Recommendations for chamber quantification: A report from the American Society of Echocardiography's Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardiology
    • Lang RM, Bierig M, Devereux RB et al. Recommendations for chamber quantification: a report from the American Society of Echocardiography's Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardiology. J Am Soc Echocardiogr 2005; 18: 1440-1463
    • (2005) J Am Soc Echocardiogr , vol.18 , pp. 1440-1463
    • Lang, R.M.1    Bierig, M.2    Devereux, R.B.3
  • 22
    • 77954997596 scopus 로고    scopus 로고
    • Inter-and intra-observer variability in the echocardiographic evaluation of right ventricular function
    • Pinedo M, Villacorta E, Tapia C et al. Inter-and intra-observer variability in the echocardiographic evaluation of right ventricular function. Rev Esp Cardiol 2010; 63: 802-809
    • (2010) Rev Esp Cardiol , vol.63 , pp. 802-809
    • Pinedo, M.1    Villacorta, E.2    Tapia, C.3
  • 23
    • 1642304976 scopus 로고    scopus 로고
    • Prognostic value of echocardiographic indicators of left ventricular systolic function in asymptomatic dialysis patients
    • Zoccali C, Benedetto FA, Mallamaci F et al. Prognostic value of echocardiographic indicators of left ventricular systolic function in asymptomatic dialysis patients. J Am Soc Nephrol 2000; 15: 1029-1037
    • (2000) J Am Soc Nephrol , vol.15 , pp. 1029-1037
    • Zoccali, C.1    Benedetto, F.A.2    Mallamaci, F.3
  • 24
    • 1642545133 scopus 로고    scopus 로고
    • Left ventricular mass monitoring in the follow-up of dialysis patients: Prognostic value of left ventricular hypertrophy progression
    • Zoccali C, Benedetto FA, Mallamaci F et al. Left ventricular mass monitoring in the follow-up of dialysis patients: prognostic value of left ventricular hypertrophy progression. Kidney Int 2004; 65: 1492-1498
    • (2004) Kidney Int , vol.65 , pp. 1492-1498
    • Zoccali, C.1    Benedetto, F.A.2    Mallamaci, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.