메뉴 건너뛰기




Volumn 7, Issue 4, 2013, Pages 378-386

Transoesophageal Doppler compared to central venous pressure for perioperative hemodynamic monitoring and fluid guidance in liver resection

Author keywords

Central venous pressure; liver resection; monitoring; transoesophageal Doppler

Indexed keywords

ANTIEMETIC AGENT; HETASTARCH;

EID: 84889868486     PISSN: 1658354X     EISSN: 09753125     Source Type: Journal    
DOI: 10.4103/1658-354X.121044     Document Type: Article
Times cited : (19)

References (42)
  • 2
    • 0033924934 scopus 로고    scopus 로고
    • Factors affecting survival and long-Term outcome in the cirrhotic patient undergoing hepatic resection for hepatocellular carcinoma
    • Chiappa A, Zbar AP, Audisio RA, Leone BE, Biella F, Staudacher C. Factors affecting survival and long-Term outcome in the cirrhotic patient undergoing hepatic resection for hepatocellular carcinoma. Eur J Surg Oncol 2000;26:387-92.
    • (2000) Eur J Surg Oncol , vol.26 , pp. 387-392
    • Chiappa, A.1    Zbar, A.P.2    Audisio, R.A.3    Leone, B.E.4    Biella, F.5    Staudacher, C.6
  • 4
  • 5
    • 0033503797 scopus 로고    scopus 로고
    • Intrahepatic recurrence after curative resection of hepatocellular carcinoma: Long-Term results of treatment and prognostic factors
    • Poon RT, Fan ST, Lo CM, Liu CL, Wong J. Intrahepatic recurrence after curative resection of hepatocellular carcinoma: Long-Term results of treatment and prognostic factors. Ann Surg 1999;229:216-22.
    • (1999) Ann Surg , vol.229 , pp. 216-222
    • Poon, R.T.1    Fan, S.T.2    Lo, C.M.3    Liu, C.L.4    Wong, J.5
  • 6
    • 1542374693 scopus 로고    scopus 로고
    • The role of central venous pressure and type of vascular control in blood loss during major liver resections
    • Smyrniotis V, Kostopanagiotou G, Theodoraki K, Tsantoulas D, Contis JC. The role of central venous pressure and type of vascular control in blood loss during major liver resections. Am J Surg 2004;187:398-402.
    • (2004) Am J Surg , vol.187 , pp. 398-402
    • Smyrniotis, V.1    Kostopanagiotou, G.2    Theodoraki, K.3    Tsantoulas, D.4    Contis, J.C.5
  • 8
    • 0036766477 scopus 로고    scopus 로고
    • Analysis of donor risk in living-donor hepatectomy: The impact of resection type on clinical outcome
    • Salamé E, Goldstein MJ, Kinkhabwala M, Kapur S, Finn R, Lobritto S, et al. Analysis of donor risk in living-donor hepatectomy: The impact of resection type on clinical outcome. Am J Transplant 2002;2:780-8.
    • (2002) Am J Transplant , vol.2 , pp. 780-788
    • Salamé, E.1    Goldstein, M.J.2    Kinkhabwala, M.3    Kapur, S.4    Finn, R.5    Lobritto, S.6
  • 9
    • 35448988856 scopus 로고    scopus 로고
    • Can peripheral venous pressure be an alternative to central venous pressure during right hepatectomy in living donors?
    • Choi SJ, Gwak MS, Ko JS, Kim GS, Kim T H, Ahn H, et al. Can peripheral venous pressure be an alternative to central venous pressure during right hepatectomy in living donors? Liver Transpl 2007;13:1414-21.
    • (2007) Liver Transpl , vol.13 , pp. 1414-1421
    • Choi, S.J.1    Gwak, M.S.2    Ko, J.S.3    Kim, G.S.4    Kim, T.H.5    Ahn, H.6
  • 10
    • 83455196998 scopus 로고    scopus 로고
    • External jugular venous pressure as an alternative to conventional central venous pressure in right lobe donor hepatectomies
    • A bdullah MH, Soliman Hel D, Morad WS. External jugular venous pressure as an alternative to conventional central venous pressure in right lobe donor hepatectomies. Exp Clin Transplant 2011;9:393-8.
    • (2011) Exp Clin Transplant , vol.9 , pp. 393-398
    • Abdullah, M.H.1    Soliman Hel, D.2    Morad, W.S.3
  • 11
    • 28844437787 scopus 로고    scopus 로고
    • Hemodynamic measurements after cardiac surgery: Transesophageal Doppler versus pulmonary artery catheter
    • Sharma J, Bhise M, Singh A, Mehta Y, Trehan N. Hemodynamic measurements after cardiac surgery: Transesophageal Doppler versus pulmonary artery catheter. J Cardiothorac Vasc Anesth 2005;19:746-50.
    • (2005) J Cardiothorac Vasc Anesth , vol.19 , pp. 746-750
    • Sharma, J.1    Bhise, M.2    Singh, A.3    Mehta, Y.4    Trehan, N.5
  • 12
    • 20244362259 scopus 로고    scopus 로고
    • Noninvasive measurements of preload using esophageal Doppler are superior to pressure-based estimates in critically injured patients
    • Kincaid EH, Fly MG, Chang MC. Noninvasive measurements of preload using esophageal Doppler are superior to pressure-based estimates in critically injured patients. Crit Care Med 1999;27:100.
    • (1999) Crit Care Med , vol.27 , pp. 100
    • Kincaid, E.H.1    Fly, M.G.2    Chang, M.C.3
  • 13
    • 0038342704 scopus 로고    scopus 로고
    • Doppler-based hemodynamic monitoring: A minimally invasive alternative
    • T urner MA. Doppler-based hemodynamic monitoring: A minimally invasive alternative. AACN Clin Issues 2003;14:220-31.
    • (2003) AACN Clin Issues , vol.14 , pp. 220-231
    • Turner, M.A.1
  • 14
    • 0025995952 scopus 로고
    • Effects of alterations in left ventricular filling, contractility, and systemic vascular resistance on the ascending aortic blood velocity waveform of normal subjects
    • Singer M, Allen MJ, Webb AR, Bennett ED. Effects of alterations in left ventricular filling, contractility, and systemic vascular resistance on the ascending aortic blood velocity waveform of normal subjects. Crit Care Med 1991;19:1138-45.
    • (1991) Crit Care Med , vol.19 , pp. 1138-1145
    • Singer, M.1    Allen, M.J.2    Webb, A.R.3    Bennett, E.D.4
  • 15
    • 0030843904 scopus 로고    scopus 로고
    • Intraoperative intravascular volume optimisation and length of hospital stay after repair of proximal femoral fracture: Randomised controlled trial
    • Sinclair S, James S, Singer M. Intraoperative intravascular volume optimisation and length of hospital stay after repair of proximal femoral fracture: Randomised controlled trial. BMJ 1997;315:909-12.
    • (1997) BMJ , vol.315 , pp. 909-912
    • Sinclair, S.1    James, S.2    Singer, M.3
  • 16
    • 12244302493 scopus 로고    scopus 로고
    • Perioperative effects of hepatic resection surgery on hemodynamics, pulmonary fluid balance, and indocyanine green clearance
    • T hasler WE, Bein T, Jauch KW. Perioperative effects of hepatic resection surgery on hemodynamics, pulmonary fluid balance, and indocyanine green clearance. Langenbecks Arch Surg 2002;387:271-5.
    • (2002) Langenbecks Arch Surg , vol.387 , pp. 271-275
    • Thasler, W.E.1    Bein, T.2    Jauch, K.W.3
  • 18
    • 0346500921 scopus 로고    scopus 로고
    • Anesthetic management and complications in living donor hepatectomy
    • A yanoglu HO, Ulukaya S, Yuzer Y, Tokat Y. Anesthetic management and complications in living donor hepatectomy. Transplant Proc 2003;35:2970-3.
    • (2003) Transplant Proc , vol.35 , pp. 2970-2973
    • Ayanoglu, H.O.1    Ulukaya, S.2    Yuzer, Y.3    Tokat, Y.4
  • 19
    • 0036794632 scopus 로고    scopus 로고
    • Safety of right lobectomy in living donor liver transplantation
    • Suh KS, Kim SH, Kim SB, Lee HJ, Lee KU. Safety of right lobectomy in living donor liver transplantation. Liver Transpl 2002;8:910-5.
    • (2002) Liver Transpl , vol.8 , pp. 910-915
    • Suh, K.S.1    Kim, S.H.2    Kim, S.B.3    Lee, H.J.4    Lee, K.U.5
  • 20
    • 1642386676 scopus 로고    scopus 로고
    • Anesthetic considerations during liver surgery
    • R edai I, Emond J, Brentjens T. Anesthetic considerations during liver surgery. Surg Clin North Am 2004;84:401-11.
    • (2004) Surg Clin North Am , vol.84 , pp. 401-411
    • Redai, I.1    Emond, J.2    Brentjens, T.3
  • 21
    • 0036828719 scopus 로고    scopus 로고
    • Anaesthesia for elective liver resection: Some points should be revisited
    • L entschener C, Ozier Y. Anaesthesia for elective liver resection: Some points should be revisited. Eur J Anaesthesiol 2002;19:780-8.
    • (2002) Eur J Anaesthesiol , vol.19 , pp. 780-788
    • Lentschener, C.1    Ozier, Y.2
  • 22
    • 34548247113 scopus 로고    scopus 로고
    • Evaluation of corrected flow time in oesophageal Doppler as a predictor of fluid responsiveness
    • Lee JH, Kim JT, Yoon SZ, Lim YJ, Jeon Y, Bahk JH, et al. Evaluation of corrected flow time in oesophageal Doppler as a predictor of fluid responsiveness. Br J Anaesth 2007;99:343-8.
    • (2007) Br J Anaesth , vol.99 , pp. 343-348
    • Lee, J.H.1    Kim, J.T.2    Yoon, S.Z.3    Lim, Y.J.4    Jeon, Y.5    Bahk, J.H.6
  • 23
    • 0033924592 scopus 로고    scopus 로고
    • Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure
    • Michard F, Boussat S, Chemla D, Anguel N, Mercat A, Lecarpentier Y, et al. Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med 2000;162:134-8.
    • (2000) Am J Respir Crit Care Med , vol.162 , pp. 134-138
    • Michard, F.1    Boussat, S.2    Chemla, D.3    Anguel, N.4    Mercat, A.5    Lecarpentier, Y.6
  • 25
    • 0025663363 scopus 로고
    • Measurements of right ventricular volumes during fluid challenge
    • R euse C, Vincent JL, Pinsky MR. Measurements of right ventricular volumes during fluid challenge. Chest 1990;98:1450-4.
    • (1990) Chest , vol.98 , pp. 1450-1454
    • Reuse, C.1    Vincent, J.L.2    Pinsky, M.R.3
  • 26
    • 47549096309 scopus 로고    scopus 로고
    • Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares
    • Marik PE, Baram M, Vahid B. Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. Chest 2008;134:172-8.
    • (2008) Chest , vol.134 , pp. 172-178
    • Marik, P.E.1    Baram, M.2    Vahid, B.3
  • 27
    • 0242468625 scopus 로고    scopus 로고
    • Global end-diastolic volume as an indicator of cardiac preload in patients with septic shock
    • Michard F, Alaya S, Zarka V, Bahloul M, Richard C, Teboul JL. Global end-diastolic volume as an indicator of cardiac preload in patients with septic shock. Chest 2003;124:1900-8.
    • (2003) Chest , vol.124 , pp. 1900-1908
    • Michard, F.1    Alaya, S.2    Zarka, V.3    Bahloul, M.4    Richard, C.5    Teboul, J.L.6
  • 28
    • 20644440408 scopus 로고    scopus 로고
    • How to use central venous pressure measurements
    • Magder S. How to use central venous pressure measurements. Curr Opin Crit Care 2005;11:264-70.
    • (2005) Curr Opin Crit Care , vol.11 , pp. 264-270
    • Magder, S.1
  • 29
    • 33751021087 scopus 로고    scopus 로고
    • Practical issues of hemodynamic monitoring at the bedside
    • Polanco PM, Pinsky MR. Practical issues of hemodynamic monitoring at the bedside. Surg Clin North Am 2006;86:1431-56.
    • (2006) Surg Clin North Am , vol.86 , pp. 1431-1456
    • Polanco, P.M.1    Pinsky, M.R.2
  • 30
    • 1242319454 scopus 로고    scopus 로고
    • Managing inadvertent arterial catheterization during central venous access procedures
    • Nicholson T, Ettles D, Robinson G. Managing inadvertent arterial catheterization during central venous access procedures. Cardiovasc Intervent Radiol 2004;27:21-5.
    • (2004) Cardiovasc Intervent Radiol , vol.27 , pp. 21-25
    • Nicholson, T.1    Ettles, D.2    Robinson, G.3
  • 31
    • 0036906784 scopus 로고    scopus 로고
    • Intraoperative hemodynamics and liver function in adult-To-Adult living liver donors
    • Niemann CU, Roberts JP, Ascher NL, Yost CS. Intraoperative hemodynamics and liver function in adult-To-Adult living liver donors. Liver Transpl 2002;8:1126-32.
    • (2002) Liver Transpl , vol.8 , pp. 1126-1132
    • Niemann, C.U.1    Roberts, J.P.2    Ascher, N.L.3    Yost, C.S.4
  • 32
    • 0025815150 scopus 로고
    • Changes in portal blood flow consequent to partial hepatectomy: Doppler estimation
    • Kawasaki T, Moriyasu F, Kimura T, Someda H, Fukuda Y, Ozawa K. Changes in portal blood flow consequent to partial hepatectomy: Doppler estimation. Radiology 1991;180:373-7.
    • (1991) Radiology , vol.180 , pp. 373-377
    • Kawasaki, T.1    Moriyasu, F.2    Kimura, T.3    Someda, H.4    Fukuda, Y.5    Ozawa, K.6
  • 33
    • 0028845736 scopus 로고
    • Endotoxin and interleukin-1 related hepatic inflammatory response promotes liver failure after partial hepatectomy
    • Boermeester MA, Straatsburg I H, Houdijk A P, Meyer C, Frederiks WM, Wesdorp RI, et al. Endotoxin and interleukin-1 related hepatic inflammatory response promotes liver failure after partial hepatectomy. Hepatology 1995;22:1499-506.
    • (1995) Hepatology , vol.22 , pp. 1499-1506
    • Boermeester, M.A.1    Straatsburg, I.H.2    Houdijk, A.P.3    Meyer, C.4    Frederiks, W.M.5    Wesdorp, R.I.6
  • 34
    • 0028863627 scopus 로고
    • Molecular mechanisms and therapeutic strategies related to nitric oxide
    • Moncada S, Higgs EA. Molecular mechanisms and therapeutic strategies related to nitric oxide. FASEB J 1995;9:1319-30.
    • (1995) FASEB J , vol.9 , pp. 1319-1330
    • Moncada, S.1    Higgs, E.A.2
  • 35
    • 0027511853 scopus 로고
    • The discovery of nitric oxide in the vessel wall. A unifying concept in the pathogenesis of sepsis
    • Palmer R M. The discovery of nitric oxide in the vessel wall. A unifying concept in the pathogenesis of sepsis. Arch Surg 1993;128:396-401.
    • (1993) Arch Surg , vol.128 , pp. 396-401
    • Palmer, R.M.1
  • 36
    • 0032697568 scopus 로고    scopus 로고
    • Organ blood flow after partial hepatectomy in rats: Modification by endotoxin-neutralizing bactericidal/permeability-increasing protein (rBPI23)
    • Boermeester MA, Houdijk A P, Straatsburg I H, van Noorden CJ, van Leeuwen PA. Organ blood flow after partial hepatectomy in rats: Modification by endotoxin-neutralizing bactericidal/permeability-increasing protein (rBPI23). J Hepatol 1999;31:905-12.
    • (1999) J Hepatol , vol.31 , pp. 905-912
    • Boermeester, M.A.1    Houdijk, A.P.2    Straatsburg, I.H.3    Van Noorden, C.J.4    Van Leeuwen, P.A.5
  • 37
    • 0026090522 scopus 로고
    • Effect of hyperdynamic circulatory support on hepatic hemodynamics, oxygen supply and demand after massive hepatectomy
    • Nonami T, Asahi K, Harada A, Nakao A, Takagi H. Effect of hyperdynamic circulatory support on hepatic hemodynamics, oxygen supply and demand after massive hepatectomy. Surgery 1991;109:277-83.
    • (1991) Surgery , vol.109 , pp. 277-283
    • Nonami, T.1    Asahi, K.2    Harada, A.3    Nakao, A.4    Takagi, H.5
  • 38
    • 0027483841 scopus 로고
    • Hormonal and splanchnic hemodynamic alterations following hepatic resection
    • Wu Y, Campbell KA, Sitzmann JV. Hormonal and splanchnic hemodynamic alterations following hepatic resection. J Surg Res 1993;55:44-8.
    • (1993) J Surg Res , vol.55 , pp. 44-48
    • Wu, Y.1    Campbell, K.A.2    Sitzmann, J.V.3
  • 39
    • 0033799059 scopus 로고    scopus 로고
    • Changes in prostaglandin and nitric oxide levels in the hyperdynamic circulation following liver resection
    • L ai O F, Chow PK, Tan S, Song I C, Soo KC, Aw SE, et al. Changes in prostaglandin and nitric oxide levels in the hyperdynamic circulation following liver resection. J Gastroenterol Hepatol 2000;15:895-901.
    • (2000) J Gastroenterol Hepatol , vol.15 , pp. 895-901
    • Lai, O.F.1    Chow, P.K.2    Tan, S.3    Song, I.C.4    Soo, K.C.5    Aw, S.E.6
  • 40
    • 17344394933 scopus 로고    scopus 로고
    • Changes in hepatic venous oxygen saturation related to the extent of regeneration after partial hepatectomy in rats
    • Shimizu H, Miyazaki M, Yoshioka S, Ito H, Nakagawa K, Ambiru S, et al. Changes in hepatic venous oxygen saturation related to the extent of regeneration after partial hepatectomy in rats. Am J Surg 1999;178:428-31.
    • (1999) Am J Surg , vol.178 , pp. 428-431
    • Shimizu, H.1    Miyazaki, M.2    Yoshioka, S.3    Ito, H.4    Nakagawa, K.5    Ambiru, S.6
  • 41
    • 27744442396 scopus 로고    scopus 로고
    • Intraoperative oesophageal Doppler guided fluid management shortens postoperative hospital stay after major bowel surgery
    • Wakeling HG, McFall MR, Jenkins CS, Woods WG, Miles WF, Barclay GR, et al. Intraoperative oesophageal Doppler guided fluid management shortens postoperative hospital stay after major bowel surgery. Br J Anaesth 2005;95:634-42.
    • (2005) Br J Anaesth , vol.95 , pp. 634-642
    • Wakeling, H.G.1    McFall, M.R.2    Jenkins, C.S.3    Woods, W.G.4    Miles, W.F.5    Barclay, G.R.6
  • 42
    • 0028949112 scopus 로고
    • Perioperative plasma volume expansion reduces the incidence of gut mucosal hypoperfusion during cardiac surgery
    • Mythen MG, Webb AR. Perioperative plasma volume expansion reduces the incidence of gut mucosal hypoperfusion during cardiac surgery. Arch Surg 1995;130:423-9.
    • (1995) Arch Surg , vol.130 , pp. 423-429
    • Mythen, M.G.1    Webb, A.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.