-
1
-
-
66549112943
-
Traceability in laboratory medicine
-
Vesper H.W., Thienpont L.M. Traceability in laboratory medicine. Clin Chem 2009, 55:1067-1075.
-
(2009)
Clin Chem
, vol.55
, pp. 1067-1075
-
-
Vesper, H.W.1
Thienpont, L.M.2
-
2
-
-
84872374096
-
A guide to harmonization and standardization of measurands determined by liquid chromatography-tandem mass spectrometry in routine clinical biochemistry
-
Greaves R.F. A guide to harmonization and standardization of measurands determined by liquid chromatography-tandem mass spectrometry in routine clinical biochemistry. Clin Biochem Rev 2012, 33:123-132.
-
(2012)
Clin Biochem Rev
, vol.33
, pp. 123-132
-
-
Greaves, R.F.1
-
3
-
-
84863410351
-
Preparation and value assignment of standard reference material 968e fat-soluble vitamins, carotenoids, and cholesterol in human serum
-
Thomas J.B., Duewer D.L., Mugenya I.O., Phinney K.W., Sander L.C., Sharpless K.E., et al. Preparation and value assignment of standard reference material 968e fat-soluble vitamins, carotenoids, and cholesterol in human serum. Anal Bioanal Chem 2012, 402:749-762.
-
(2012)
Anal Bioanal Chem
, vol.402
, pp. 749-762
-
-
Thomas, J.B.1
Duewer, D.L.2
Mugenya, I.O.3
Phinney, K.W.4
Sander, L.C.5
Sharpless, K.E.6
-
5
-
-
74249116046
-
Basics of estimating measurement uncertainty
-
White G.H. Basics of estimating measurement uncertainty. Clin Biochem Rev 2008, 29(Suppl. 1):S53-S60.
-
(2008)
Clin Biochem Rev
, vol.29
, Issue.SUPPL. 1
-
-
White, G.H.1
-
6
-
-
84889650835
-
RCPA Quality Assurance Programs
-
Available at, [Accessed 18th August 2013]
-
RCPA Quality Assurance Programs Chemical pathology, vitamin program Available at, [Accessed 18th August 2013]. http://www.rcpaqap.com.au/chempath/.
-
Chemical pathology, vitamin program
-
-
-
7
-
-
75149116276
-
Serum vitamin A and E analysis: comparison of methods between laboratories enrolled in an external quality assurance programme
-
Greaves R., Jolly L., Woollard G., Hoad K. Serum vitamin A and E analysis: comparison of methods between laboratories enrolled in an external quality assurance programme. Ann Clin Biochem 2010, 47:78-80.
-
(2010)
Ann Clin Biochem
, vol.47
, pp. 78-80
-
-
Greaves, R.1
Jolly, L.2
Woollard, G.3
Hoad, K.4
-
8
-
-
10644267237
-
-
National Institute of Standards and Technology, Washington
-
Gallaher M.P., Mobley L.R., Klee G.G., Schryver P. The impact of calibration error in medical decision making 2004, National Institute of Standards and Technology, Washington.
-
(2004)
The impact of calibration error in medical decision making
-
-
Gallaher, M.P.1
Mobley, L.R.2
Klee, G.G.3
Schryver, P.4
-
9
-
-
84855163304
-
External quality assurance target setting with NIST SRM 968d material: performance in the 2010 Royal College of Pathologists of Australasia Quality Assurance Program with retinol, α-tocopherol and β-carotene
-
Greaves R.F., Hoad K.E., Woollard G.A., Walmsley T.A., Briscoe S., Johnson L.A., et al. External quality assurance target setting with NIST SRM 968d material: performance in the 2010 Royal College of Pathologists of Australasia Quality Assurance Program with retinol, α-tocopherol and β-carotene. Ann Clin Biochem 2011, 48:480-482.
-
(2011)
Ann Clin Biochem
, vol.48
, pp. 480-482
-
-
Greaves, R.F.1
Hoad, K.E.2
Woollard, G.A.3
Walmsley, T.A.4
Briscoe, S.5
Johnson, L.A.6
-
10
-
-
44349178752
-
Traceability, reference systems and result comparability
-
Panteghini M. Traceability, reference systems and result comparability. Clin Biochem Rev 2007, 28:97-104.
-
(2007)
Clin Biochem Rev
, vol.28
, pp. 97-104
-
-
Panteghini, M.1
-
11
-
-
84889640077
-
Is calibration the cause of variation in liquid chromatography tandem mass spectrometry testosterone measurement?
-
Owen L.J., MacDonald P.R., Keevil B.G. Is calibration the cause of variation in liquid chromatography tandem mass spectrometry testosterone measurement?. Ann Clin Biochem 2013, 50:368-370.
-
(2013)
Ann Clin Biochem
, vol.50
, pp. 368-370
-
-
Owen, L.J.1
MacDonald, P.R.2
Keevil, B.G.3
-
13
-
-
0035196397
-
Commutability of calibration and control materials for serum lipase
-
Cattozzo G., Franzini C., Melzi d'Eril G.M. Commutability of calibration and control materials for serum lipase. Clin Chem 2001, 47:2108-2113.
-
(2001)
Clin Chem
, vol.47
, pp. 2108-2113
-
-
Cattozzo, G.1
Franzini, C.2
Melzi d'Eril, G.M.3
-
14
-
-
0037559236
-
-
Standard Reference Materials Program, National Institute of Standards and Technology, Gaithersburg, MD, USA
-
Certificate of analysis, standard reference material 968e: fat-soluble vitamins, carotenoids, and cholesterol in human serum 2012, Standard Reference Materials Program, National Institute of Standards and Technology, Gaithersburg, MD, USA.
-
(2012)
Certificate of analysis, standard reference material 968e: fat-soluble vitamins, carotenoids, and cholesterol in human serum
-
-
-
15
-
-
84889678321
-
-
Standard Reference Materials Program, National Institute of Standards and Technology, Gaithersburg, MD, USA
-
Certificate of analysis, standard reference material 968d: fat-soluble vitamins, carotenoids, and cholesterol in human serum 2008, Standard Reference Materials Program, National Institute of Standards and Technology, Gaithersburg, MD, USA.
-
(2008)
Certificate of analysis, standard reference material 968d: fat-soluble vitamins, carotenoids, and cholesterol in human serum
-
-
-
16
-
-
84889651858
-
-
Reference measurement methods/procedures. JCTLM database: laboratory medicine and in vitro diagnostics, Bureau International des Poids et Mesures;. accessed at 18/03/2013.
-
Reference measurement methods/procedures. JCTLM database: laboratory medicine and in vitro diagnostics, Bureau International des Poids et Mesures;. accessed at 18/03/2013. http://www.bipm.org.
-
-
-
|