-
1
-
-
0029089012
-
Randomized trial of lobectomy versus limited resection for T1N0 non-small cell lung cancer. Lung Cancer Study Group
-
R.J. Ginsberg, and L.V. Rubinstein Randomized trial of lobectomy versus limited resection for T1N0 non-small cell lung cancer. Lung Cancer Study Group Ann Thorac Surg 60 1995 615 622
-
(1995)
Ann Thorac Surg
, vol.60
, pp. 615-622
-
-
Ginsberg, R.J.1
Rubinstein, L.V.2
-
2
-
-
33748763587
-
Radical sublobar resection for small-sized non-small cell lung cancer: A multicenter study
-
M. Okada, T. Koike, M. Higashiyama, Y. Yamato, K. Kodama, and N. Tsubota Radical sublobar resection for small-sized non-small cell lung cancer: a multicenter study J Thorac Cardiovasc Surg 132 2006 769 775
-
(2006)
J Thorac Cardiovasc Surg
, vol.132
, pp. 769-775
-
-
Okada, M.1
Koike, T.2
Higashiyama, M.3
Yamato, Y.4
Kodama, K.5
Tsubota, N.6
-
3
-
-
79551563284
-
International Association for the Study of Lung Cancer/American Thoracic Society/European Respiratory Society international multidisciplinary classification of lung adenocarcinoma
-
W.D. Travis, E. Brambilla, and M. Noguchi International Association for the Study of Lung Cancer/American Thoracic Society/European Respiratory Society international multidisciplinary classification of lung adenocarcinoma J Thorac Oncol 6 2011 244 285
-
(2011)
J Thorac Oncol
, vol.6
, pp. 244-285
-
-
Travis, W.D.1
Brambilla, E.2
Noguchi, M.3
-
4
-
-
84860379332
-
The novel histologic International Association for the Study of Lung Cancer/American Thoracic Society/European Respiratory Society classification system of lung adenocarcinoma is a stage-independent predictor of survival
-
A. Warth, T. Muley, and M. Meister The novel histologic International Association for the Study of Lung Cancer/American Thoracic Society/European Respiratory Society classification system of lung adenocarcinoma is a stage-independent predictor of survival J Clin Oncol 30 2012 1438 1446
-
(2012)
J Clin Oncol
, vol.30
, pp. 1438-1446
-
-
Warth, A.1
Muley, T.2
Meister, M.3
-
5
-
-
0037792992
-
Staging of non-small cell lung cancer with integrated positron-emission tomography and computed tomography
-
D. Lardinois, W. Weder, and T.F. Hany Staging of non-small cell lung cancer with integrated positron-emission tomography and computed tomography N Engl J Med 348 2003 2500 2507
-
(2003)
N Engl J Med
, vol.348
, pp. 2500-2507
-
-
Lardinois, D.1
Weder, W.2
Hany, T.F.3
-
6
-
-
4444346932
-
The accuracy of integrated PET-CT compared with dedicated PET alone for the staging of patients with nonsmall cell lung cancer
-
R.J. Cerfolio, B. Ojha, A.S. Bryant, V. Raghuveer, J.M. Mounts, and A.A. Bartolucci The accuracy of integrated PET-CT compared with dedicated PET alone for the staging of patients with nonsmall cell lung cancer Ann Thorac Surg 78 2004 1017 1023
-
(2004)
Ann Thorac Surg
, vol.78
, pp. 1017-1023
-
-
Cerfolio, R.J.1
Ojha, B.2
Bryant, A.S.3
Raghuveer, V.4
Mounts, J.M.5
Bartolucci, A.A.6
-
7
-
-
34249048385
-
Associations among bronchioloalveolar carcinoma components, positron emission tomographic and computed tomographic findings, and malignant behavior in small lung adenocarcinomas
-
M. Okada, S. Tauchi, and K. Iwanaga Associations among bronchioloalveolar carcinoma components, positron emission tomographic and computed tomographic findings, and malignant behavior in small lung adenocarcinomas J Thorac Cardiovasc Surg 133 2007 1448 1454
-
(2007)
J Thorac Cardiovasc Surg
, vol.133
, pp. 1448-1454
-
-
Okada, M.1
Tauchi, S.2
Iwanaga, K.3
-
8
-
-
77954261528
-
Value of integrated positron emission tomography revised using a phantom study to evaluate malignancy grade of lung adenocarcinoma: A multicenter study
-
H. Nakayama, S. Okumura, and H. Daisaki Value of integrated positron emission tomography revised using a phantom study to evaluate malignancy grade of lung adenocarcinoma: a multicenter study Cancer 116 2010 3170 3177
-
(2010)
Cancer
, vol.116
, pp. 3170-3177
-
-
Nakayama, H.1
Okumura, S.2
Daisaki, H.3
-
9
-
-
79956072660
-
Multicenter analysis of high-resolution computed tomography and positron emission tomography/computed tomography findings to choose therapeutic strategies for clinical stage IA lung adenocarcinoma
-
M. Okada, H. Nakayama, and S. Okumura Multicenter analysis of high-resolution computed tomography and positron emission tomography/computed tomography findings to choose therapeutic strategies for clinical stage IA lung adenocarcinoma J Thorac Cardiovasc Surg 141 2011 1384 1391
-
(2011)
J Thorac Cardiovasc Surg
, vol.141
, pp. 1384-1391
-
-
Okada, M.1
Nakayama, H.2
Okumura, S.3
-
10
-
-
34548457234
-
The IASLC lung cancer staging project: Proposals for the revision of the TNM stage groupings in the forthcoming (seventh) edition of the TNM classification of malignant tumours
-
P. Goldstraw, J. Crowley, and K. Chansky The IASLC lung cancer staging project: proposals for the revision of the TNM stage groupings in the forthcoming (seventh) edition of the TNM classification of malignant tumours J Thorac Oncol 2 2007 706 714
-
(2007)
J Thorac Oncol
, vol.2
, pp. 706-714
-
-
Goldstraw, P.1
Crowley, J.2
Chansky, K.3
-
11
-
-
33847159680
-
Quantification of FDG PET studies using standardized uptake values in multicenter trials: Effects of image reconstruction, resolution and ROI definition parameters
-
M. Westerterp, J. Pruim, and W. Oyen Quantification of FDG PET studies using standardized uptake values in multicenter trials: effects of image reconstruction, resolution and ROI definition parameters Eur J Nucl Med Mol Imaging 34 2007 392 404
-
(2007)
Eur J Nucl Med Mol Imaging
, vol.34
, pp. 392-404
-
-
Westerterp, M.1
Pruim, J.2
Oyen, W.3
-
12
-
-
16544364015
-
Performance characteristics of a newly developed PET/CT scanner using NEMA standards in 2D and 3D modes
-
O. Mawlawi, D.A. Podoloff, S. Kohlmyer, J.J. Williams, C.W. Stearns, and R.F. Culp Performance characteristics of a newly developed PET/CT scanner using NEMA standards in 2D and 3D modes J Nucl Med 45 2004 1734 1742
-
(2004)
J Nucl Med
, vol.45
, pp. 1734-1742
-
-
Mawlawi, O.1
Podoloff, D.A.2
Kohlmyer, S.3
Williams, J.J.4
Stearns, C.W.5
Culp, R.F.6
-
13
-
-
16244366026
-
An index for rating diagnostic tests
-
W.J. Youden An index for rating diagnostic tests Cancer 3 1950 32 35
-
(1950)
Cancer
, vol.3
, pp. 32-35
-
-
Youden, W.J.1
-
14
-
-
6944235697
-
Effects of noise, image resolution, and ROI definition on the accuracy of standard uptake values: A simulation study
-
R. Boellaard, N.C. Krak, O.S. Hoekstra, and A.A. Lammertsma Effects of noise, image resolution, and ROI definition on the accuracy of standard uptake values: a simulation study J Nucl Med 45 2004 1519 1527
-
(2004)
J Nucl Med
, vol.45
, pp. 1519-1527
-
-
Boellaard, R.1
Krak, N.C.2
Hoekstra, O.S.3
Lammertsma, A.A.4
-
15
-
-
79960032399
-
Difference in prognostic significance of maximum standardized uptake value on [18F]-fluoro-2-deoxyglucose positron emission tomography between adenocarcinoma and squamous cell carcinoma of the lung
-
Y. Tsutani, Y. Miyata, and K. Misumi Difference in prognostic significance of maximum standardized uptake value on [18F]-fluoro-2-deoxyglucose positron emission tomography between adenocarcinoma and squamous cell carcinoma of the lung Jpn J Clin Oncol 41 2011 890 896
-
(2011)
Jpn J Clin Oncol
, vol.41
, pp. 890-896
-
-
Tsutani, Y.1
Miyata, Y.2
Misumi, K.3
|