-
1
-
-
79954416679
-
Contraceptive failure in the United States
-
J. Trussell Contraceptive failure in the United States Contraception 83 5 2011 397 404
-
(2011)
Contraception
, vol.83
, Issue.5
, pp. 397-404
-
-
Trussell, J.1
-
2
-
-
2542489458
-
Society of Obstetricians and Gynaecologists of Canada
-
A. Black, D. Francoeur, T. Rowe, J. Collins, D. Miller, and T. Brown Society of Obstetricians and Gynaecologists of Canada J Obstet Gynaecol Can 26 3 2004 219 296
-
(2004)
J Obstet Gynaecol Can
, vol.26
, Issue.3
, pp. 219-296
-
-
Black, A.1
Francoeur, D.2
Rowe, T.3
Collins, J.4
Miller, D.5
Brown, T.6
-
3
-
-
78651472979
-
Uterine perforation with the levonorgestrel-releasing intrauterine device: Analysis of reports from four national pharmacovigilance centres
-
K. van Grootheest, B. Sachs, M. Harrison-Woolrych, P. Caduff-Janosa, and E. van Puijenbroek Uterine perforation with the levonorgestrel-releasing intrauterine device: analysis of reports from four national pharmacovigilance centres Drug Saf 34 1 2011 83 88
-
(2011)
Drug Saf
, vol.34
, Issue.1
, pp. 83-88
-
-
Van Grootheest, K.1
Sachs, B.2
Harrison-Woolrych, M.3
Caduff-Janosa, P.4
Van Puijenbroek, E.5
-
4
-
-
84889078981
-
-
Bayer Inc. Product monograph MIRENA: levonorgestrel-releasing intrauterine system (52 mg) to deliver up to 20 mcg levonorgestrel per day. Bayer Inc Last update, July 20, 2012
-
Bayer Inc. Product monograph MIRENA: levonorgestrel-releasing intrauterine system (52 mg) to deliver up to 20 mcg levonorgestrel per day. Bayer Inc; 2012; Available at: http://www.bayer.ca/files/MIRENA-PM-ENG- 20JUL2012-150412.pdf. Last update, July 20, 2012.
-
(2012)
-
-
-
5
-
-
0019389426
-
Complete and partial uterine perforation and embedding following insertion of intrauterine devices. I. Classification, complications, mechanism, incidence, and missing string
-
D. Zakin, W.Z. Stern, and R. Rosenblatt Complete and partial uterine perforation and embedding following insertion of intrauterine devices. I. Classification, complications, mechanism, incidence, and missing string Obstet Gynecol Surv 36 7 1981 335 353
-
(1981)
Obstet Gynecol Surv
, vol.36
, Issue.7
, pp. 335-353
-
-
Zakin, D.1
Stern, W.Z.2
Rosenblatt, R.3
-
6
-
-
0038066744
-
Tubal migration: A rare complication of an intrauterine contraceptive device leading to formation of a hydrosalpinx
-
M. Sindos, N. Pisal, M. Setchell, and A. Singer Tubal migration: a rare complication of an intrauterine contraceptive device leading to formation of a hydrosalpinx Am J Obstet Gynecol 188 4 2003 1109 1110
-
(2003)
Am J Obstet Gynecol
, vol.188
, Issue.4
, pp. 1109-1110
-
-
Sindos, M.1
Pisal, N.2
Setchell, M.3
Singer, A.4
-
7
-
-
34547185469
-
Pregnancy in a patient with a displaced levonorgestrel-releasing intrauterine system: A case report
-
H. Budiman, C. Kumper, I. Mylonas, C.J. Thaler, K. Friese, and E.R. Weissenbacher Pregnancy in a patient with a displaced levonorgestrel-releasing intrauterine system: a case report Arch Gynecol Obstet 276 3 2007 263 264
-
(2007)
Arch Gynecol Obstet
, vol.276
, Issue.3
, pp. 263-264
-
-
Budiman, H.1
Kumper, C.2
Mylonas, I.3
Thaler, C.J.4
Friese, K.5
Weissenbacher, E.R.6
-
8
-
-
70350506019
-
Fertility and endocrine effects of intra-abdominally misplaced intrauterine system for more than 2 years: A case report and review of the literature
-
G. Botros, and N. Haddad Fertility and endocrine effects of intra-abdominally misplaced intrauterine system for more than 2 years: a case report and review of the literature Hum Fertil (Camb) 12 2 2009 119 121
-
(2009)
Hum Fertil (Camb)
, vol.12
, Issue.2
, pp. 119-121
-
-
Botros, G.1
Haddad, N.2
-
9
-
-
0038070051
-
Management of a perforated levonorgestrel-medicated intrauterine device - A pharmacokinetic study: Case report
-
R. Haimov-Kochman, H. Amsalem, A. Adoni, Y. Lavy, and I.M. Spitz Management of a perforated levonorgestrel-medicated intrauterine device - a pharmacokinetic study: case report Hum Reprod 18 6 2003 1231 1233
-
(2003)
Hum Reprod
, vol.18
, Issue.6
, pp. 1231-1233
-
-
Haimov-Kochman, R.1
Amsalem, H.2
Adoni, A.3
Lavy, Y.4
Spitz, I.M.5
-
10
-
-
34248672546
-
Copper-T intrauterine device and levonorgestrel intrauterine system: Biological bases of their mechanism of action
-
M.E. Ortiz, and H.B. Croxatto Copper-T intrauterine device and levonorgestrel intrauterine system: biological bases of their mechanism of action Contraception 75 6 Suppl 2007 S16 S30
-
(2007)
Contraception
, vol.75
, Issue.6 SUPPL.
-
-
Ortiz, M.E.1
Croxatto, H.B.2
-
11
-
-
42449084573
-
Intrauterine devices and intrauterine systems
-
Eshre Capri Working Group Intrauterine devices and intrauterine systems Hum Reprod Update 14 3 2008 197 208
-
(2008)
Hum Reprod Update
, vol.14
, Issue.3
, pp. 197-208
-
-
Capri Working Group, E.1
-
12
-
-
79951764753
-
Laparoscopic removal of an intrauterine device following colon perforation
-
A. Bitterman, O. Lefel, Y. Segev, and O. Lavie Laparoscopic removal of an intrauterine device following colon perforation JSLS 14 3 2010 456 458
-
(2010)
JSLS
, vol.14
, Issue.3
, pp. 456-458
-
-
Bitterman, A.1
Lefel, O.2
Segev, Y.3
Lavie, O.4
-
13
-
-
0028094472
-
A rare case of IUD tubal migration. Case report
-
A. Azzena, F. Vasoin, P. Pellizzari, F. Quintieri, and R. Angarano A rare case of IUD tubal migration. Case report Clin Exp Obstet Gynecol 21 4 1994 246 248
-
(1994)
Clin Exp Obstet Gynecol
, vol.21
, Issue.4
, pp. 246-248
-
-
Azzena, A.1
Vasoin, F.2
Pellizzari, P.3
Quintieri, F.4
Angarano, R.5
-
14
-
-
0017074611
-
Tubal migration of a Lippes loop with subsequent intrauterine pregnancy
-
M. Gunaratne Tubal migration of a Lippes loop with subsequent intrauterine pregnancy Contraception 14 3 1976 285 289
-
(1976)
Contraception
, vol.14
, Issue.3
, pp. 285-289
-
-
Gunaratne, M.1
-
15
-
-
0019960795
-
Migration of the Lippes loop into the fallopian tube
-
D.S. Kim, Y.Y. Hwang, K.C. Kang, and M.I. Park Migration of the Lippes loop into the fallopian tube Obstet Gynecol 60 3 1982 393 394
-
(1982)
Obstet Gynecol
, vol.60
, Issue.3
, pp. 393-394
-
-
Kim, D.S.1
Hwang, Y.Y.2
Kang, K.C.3
Park, M.I.4
-
16
-
-
0021753560
-
Tubal migration of the Nova-T intrauterine device to the peritoneal cavity
-
M. Nohr Tubal migration of the Nova-T intrauterine device to the peritoneal cavity Ugeskr Laeger 146 14 1984 1048 1049
-
(1984)
Ugeskr Laeger
, vol.146
, Issue.14
, pp. 1048-1049
-
-
Nohr, M.1
-
17
-
-
0020522516
-
A rare case of IUD expulsion through the fallopian tube
-
M. Wikland, and L. Wilhelmsson A rare case of IUD expulsion through the fallopian tube Acta Obstet Gynecol Scand 62 2 1983 191 192
-
(1983)
Acta Obstet Gynecol Scand
, vol.62
, Issue.2
, pp. 191-192
-
-
Wikland, M.1
Wilhelmsson, L.2
-
18
-
-
35348984079
-
Imaging of intrauterine contraceptive devices
-
N. Peri, D. Graham, and D. Levine Imaging of intrauterine contraceptive devices J Ultrasound Med 26 10 2007 1389 1401
-
(2007)
J Ultrasound Med
, vol.26
, Issue.10
, pp. 1389-1401
-
-
Peri, N.1
Graham, D.2
Levine, D.3
-
19
-
-
0029911672
-
Control of intrauterine device insertion with three-dimensional ultrasound: Is it the future?
-
F. Bonilla-Musoles, F. Raga, N.G. Osborne, and J. Blanes Control of intrauterine device insertion with three-dimensional ultrasound: is it the future? J Clin Ultrasound 24 5 1996 263 267
-
(1996)
J Clin Ultrasound
, vol.24
, Issue.5
, pp. 263-267
-
-
Bonilla-Musoles, F.1
Raga, F.2
Osborne, N.G.3
Blanes, J.4
-
20
-
-
0030696682
-
Intrauterine device localization by three-dimensional transvaginal sonography
-
A. Lee, W. Eppel, C. Sam, A. Kratochwil, J. Deutinger, and G. Bernaschek Intrauterine device localization by three-dimensional transvaginal sonography Ultrasound Obstet Gynecol 10 4 1997 289 292
-
(1997)
Ultrasound Obstet Gynecol
, vol.10
, Issue.4
, pp. 289-292
-
-
Lee, A.1
Eppel, W.2
Sam, C.3
Kratochwil, A.4
Deutinger, J.5
Bernaschek, G.6
-
21
-
-
79960484342
-
Does the type of intrauterine device affect conspicuity on 2D and 3D ultrasound?
-
E. Moschos, and D.M. Twickler Does the type of intrauterine device affect conspicuity on 2D and 3D ultrasound? AJR Am J Roentgenol 196 6 2011 1439 1443
-
(2011)
AJR Am J Roentgenol
, vol.196
, Issue.6
, pp. 1439-1443
-
-
Moschos, E.1
Twickler, D.M.2
-
23
-
-
0030298420
-
The use of vaginal ultrasound to identify copper T IUDs at high risk of expulsion
-
C.A. Petta, D. Faundes, E. Pimentel, J. Diaz, and L. Bahamondes The use of vaginal ultrasound to identify copper T IUDs at high risk of expulsion Contraception 54 5 1996 287 289
-
(1996)
Contraception
, vol.54
, Issue.5
, pp. 287-289
-
-
Petta, C.A.1
Faundes, D.2
Pimentel, E.3
Diaz, J.4
Bahamondes, L.5
-
24
-
-
84858146072
-
Migration of intrauterine devices: Radiologic findings and implications for patient care
-
H.E. Boortz, D.J. Margolis, N. Ragavendra, M.K. Patel, and B.M. Kadell Migration of intrauterine devices: radiologic findings and implications for patient care Radiographics 32 2 2012 335 352
-
(2012)
Radiographics
, vol.32
, Issue.2
, pp. 335-352
-
-
Boortz, H.E.1
Margolis, D.J.2
Ragavendra, N.3
Patel, M.K.4
Kadell, B.M.5
-
26
-
-
0022611589
-
Sustained intrauterine release of levonorgestrel over five years
-
C.G. Nilsson, P.L. Lahteenmaki, T. Luukkainen, and D.N. Robertson Sustained intrauterine release of levonorgestrel over five years Fertil Steril 45 6 1986 805 807
-
(1986)
Fertil Steril
, vol.45
, Issue.6
, pp. 805-807
-
-
Nilsson, C.G.1
Lahteenmaki, P.L.2
Luukkainen, T.3
Robertson, D.N.4
|