메뉴 건너뛰기




Volumn 15, Issue 4, 2013, Pages 268-272

How many measurements are needed for liver stiffness assessment by 2D-Shear Wave Elastography (2D-SWE) and which value should be used: The mean or median?

Author keywords

Liver stiffness; Shear wave elastography; Transient elastography

Indexed keywords

ADULT; AGED; ANALYTICAL PARAMETERS; ARTICLE; CHRONIC LIVER DISEASE; CLINICAL ASSESSMENT; CONTROLLED STUDY; CORRELATION ANALYSIS; DIAGNOSTIC VALUE; ELASTOGRAPHY; FEMALE; HEPATOBILIARY PARAMETERS; HUMAN; INTERMETHOD COMPARISON; LIVER EXAMINATION; LIVER FIBROSIS; LIVER STIFFNESS; MAJOR CLINICAL STUDY; MALE; MEAN VALUE; MEDIAN VALUE; NON INVASIVE PROCEDURE; PROSPECTIVE STUDY; TWO DIMENSIONAL SHEAR WAVE ELASTOGRAPHY;

EID: 84888786664     PISSN: 18444172     EISSN: 20668643     Source Type: Journal    
DOI: 10.11152/mu.2013.2066.154.isp2     Document Type: Article
Times cited : (72)

References (24)
  • 2
    • 79960453276 scopus 로고    scopus 로고
    • EASL Clinical Practice Guidelines: management of hepatitis C virus infection
    • European Association for the Study of the Liver.
    • European Association for the Study of the Liver. EASL Clinical Practice Guidelines: management of hepatitis C virus infection. J Hepatol 2011; 55: 245-264.
    • (2011) J Hepatol , vol.55 , pp. 245-264
  • 3
    • 84876116484 scopus 로고    scopus 로고
    • EFSUMB Guidelines and recommendations on the clinical use of ultrasound elastography. Part 1: Basic principles and technology
    • Bamber J, Cosgrove D, Dietrich C.F, et al. EFSUMB Guidelines and recommendations on the clinical use of ultrasound elastography. Part 1: Basic principles and technology. Ultraschall Med. 2013; 34: 169-184.
    • (2013) Ultraschall Med. , vol.34 , pp. 169-184
    • Bamber, J.1    Cosgrove, D.2    Dietrich, C.F.3
  • 4
    • 84878241671 scopus 로고    scopus 로고
    • EFSUMB guidelines and recommendations on the clinical use of ultrasound elastography. Part 2: Clinical applications
    • Cosgrove D, Piscaglia F, Bamber J, et al. EFSUMB guidelines and recommendations on the clinical use of ultrasound elastography. Part 2: Clinical applications. Ultraschall Med. 2013; 34: 238-253.
    • (2013) Ultraschall Med. , vol.34 , pp. 238-253
    • Cosgrove, D.1    Piscaglia, F.2    Bamber, J.3
  • 5
    • 84862664371 scopus 로고    scopus 로고
    • EASL clinical practice guidelines: Management of chronic hepatitis B virus infection
    • European Association for the Study of the Liver.
    • European Association for the Study of the Liver. EASL clinical practice guidelines: Management of chronic hepatitis B virus infection. J Hepatol 2012; 57: 167-185.
    • (2012) J Hepatol , vol.57 , pp. 167-185
  • 6
    • 84881552256 scopus 로고    scopus 로고
    • Meta-analysis: ARFI elastography versus transient elastography for the evaluation of liver fibrosis
    • Bota S, Herkner H, Sporea I, et al. Meta-analysis: ARFI elastography versus transient elastography for the evaluation of liver fibrosis. Liver Int. 2013; 33: 1138-1147.
    • (2013) Liver Int. , vol.33 , pp. 1138-1147
    • Bota, S.1    Herkner, H.2    Sporea, I.3
  • 7
    • 79960933101 scopus 로고    scopus 로고
    • Noninvasive in vivo liver fibrosis evaluation using supersonic shear imaging: a clinical study on 113 hepatitis C virus patients
    • Bavu E, Gennisson JL, Couade M, et al. Noninvasive in vivo liver fibrosis evaluation using supersonic shear imaging: a clinical study on 113 hepatitis C virus patients. Ultrasound Med Biol 2011; 37: 1361-1373.
    • (2011) Ultrasound Med Biol , vol.37 , pp. 1361-1373
    • Bavu, E.1    Gennisson, J.L.2    Couade, M.3
  • 8
    • 84870530814 scopus 로고    scopus 로고
    • Accuracy of real-time shear wave elastography for assessing liver fibrosis in chronic hepatitis C: a pilot study
    • Liver Fibrosis Study Group.
    • Ferraioli G, Tinelli C, Dal Bello B, Zicchetti M, Filice G, Filice C; Liver Fibrosis Study Group. Accuracy of real-time shear wave elastography for assessing liver fibrosis in chronic hepatitis C: a pilot study. Hepatology 2012; 56:2125-2133.
    • (2012) Hepatology , vol.56 , pp. 2125-2133
    • Ferraioli, G.1    Tinelli, C.2    Dal Bello, B.3    Zicchetti, M.4    Filice, G.5    Filice, C.6
  • 9
    • 84876289848 scopus 로고    scopus 로고
    • Liver fibrosis evaluation using real-time shear wave elastography: applicability and diagnostic performance using methods without a gold standard
    • Poynard T, Munteanu M, Luckina E, et al. Liver fibrosis evaluation using real-time shear wave elastography: applicability and diagnostic performance using methods without a gold standard. J Hepatol 2013; 58: 928-935.
    • (2013) J Hepatol , vol.58 , pp. 928-935
    • Poynard, T.1    Munteanu, M.2    Luckina, E.3
  • 10
    • 84884532167 scopus 로고    scopus 로고
    • Acoustic radiation force impulse and supersonic shear imaging versus transient elastography for liver fibrosis assessment
    • Sporea I, Bota S, Jurchis A, et al. Acoustic radiation force impulse and supersonic shear imaging versus transient elastography for liver fibrosis assessment. Ultrasound Med Biol 2013; 39: 1933-1941.
    • (2013) Ultrasound Med Biol , vol.39 , pp. 1933-1941
    • Sporea, I.1    Bota, S.2    Jurchis, A.3
  • 11
    • 84874775131 scopus 로고    scopus 로고
    • Staging of hepatic fibrosis: comparison of magnetic resonance elastography and shear wave elastography in the same individuals
    • Yoon JH, Lee JM, Woo HS, et al. Staging of hepatic fibrosis: comparison of magnetic resonance elastography and shear wave elastography in the same individuals. Korean J Radiol 2013; 14: 202-212.
    • (2013) Korean J Radiol , vol.14 , pp. 202-212
    • Yoon, J.H.1    Lee, J.M.2    Woo, H.S.3
  • 12
    • 84888790657 scopus 로고    scopus 로고
    • Quantitative Elastography of Liver Fibrosis and Spleen Stiffness in Chronic Hepatitis B Carriers: Comparison of Shear-Wave Elastography and Transient Elastography with Liver Biopsy Correlation
    • Aug 2. [Epub ahead of print]
    • Leung VY, Shen J, Wong VW, et al. Quantitative Elastography of Liver Fibrosis and Spleen Stiffness in Chronic Hepatitis B Carriers: Comparison of Shear-Wave Elastography and Transient Elastography with Liver Biopsy Correlation. Radiology 2013 Aug 2. [Epub ahead of print]
    • (2013) Radiology
    • Leung, V.Y.1    Shen, J.2    Wong, V.W.3
  • 13
    • 77950619459 scopus 로고    scopus 로고
    • Pitfalls of liver stiffness measurement: a 5-year prospective study of 13,369 examinations
    • Castéra L, Foucher J, Bernard PH, et al. Pitfalls of liver stiffness measurement: a 5-year prospective study of 13,369 examinations. Hepatology 2010; 51: 828-835.
    • (2010) Hepatology , vol.51 , pp. 828-835
    • Castéra, L.1    Foucher, J.2    Bernard, P.H.3
  • 14
    • 10444241032 scopus 로고    scopus 로고
    • The role of viscosity in the impulse diffraction field of elastic waves induced by the acoustic radiation force
    • BercoffJ, Tanter M, Muller M, Fink M. The role of viscosity in the impulse diffraction field of elastic waves induced by the acoustic radiation force. IEEE Trans Ultrason Ferroelectr Freq Control 2004; 51: 1523-1536.
    • (2004) IEEE Trans Ultrason Ferroelectr Freq Control , vol.51 , pp. 1523-1536
    • Bercoff, J.1    Tanter, M.2    Muller, M.3    Fink, M.4
  • 15
    • 78751515404 scopus 로고    scopus 로고
    • Acoustic radiation force impulse elastography as compared to transient elastography and liver biopsy in patients with chronic hepatopathies
    • Sporea I, Sirli RL, Deleanu A, et al. Acoustic radiation force impulse elastography as compared to transient elastography and liver biopsy in patients with chronic hepatopathies. Ultraschall Med 2011; 32 (Suppl 1): S46-S52.
    • (2011) Ultraschall Med , vol.32 , Issue.SUPPL. 1
    • Sporea, I.1    Sirli, R.L.2    Deleanu, A.3
  • 16
    • 79953782212 scopus 로고    scopus 로고
    • Accuracy of VirtualTouch Acoustic Radiation Force Impulse (ARFI) imaging for the diagnosis of cirrhosis during liver ultrasonography
    • Piscaglia F, Salvatore V, Di Donato R, et al. Accuracy of VirtualTouch Acoustic Radiation Force Impulse (ARFI) imaging for the diagnosis of cirrhosis during liver ultrasonography. Ultraschall Med 2011; 32: 167-175.
    • (2011) Ultraschall Med , vol.32 , pp. 167-175
    • Piscaglia, F.1    Salvatore, V.2    Di Donato, R.3
  • 17
    • 70249130127 scopus 로고    scopus 로고
    • Liver fibrosis in viral hepatitis: noninvasive assessment with acoustic radiation force impulse imaging versus transient elastography
    • Friedrich-Rust M, Wunder K, Kriener S, et al. Liver fibrosis in viral hepatitis: noninvasive assessment with acoustic radiation force impulse imaging versus transient elastography. Radiology 2009; 252: 595-604.
    • (2009) Radiology , vol.252 , pp. 595-604
    • Friedrich-Rust, M.1    Wunder, K.2    Kriener, S.3
  • 18
    • 85027943357 scopus 로고    scopus 로고
    • Evaluation of liver fibrosis by transient elastography using acoustic radiation force impulse: comparison with Fibroscan(®)
    • Ebinuma H, Saito H, Komuta M, et al. Evaluation of liver fibrosis by transient elastography using acoustic radiation force impulse: comparison with Fibroscan(®). J Gastroenterol 2011; 46: 1238-1248.
    • (2011) J Gastroenterol , vol.46 , pp. 1238-1248
    • Ebinuma, H.1    Saito, H.2    Komuta, M.3
  • 19
    • 80053912735 scopus 로고    scopus 로고
    • Is it better to use two elastographic methods for liver fibrosis assessment?
    • Sporea I, Şirli R, Popescu A, et al. Is it better to use two elastographic methods for liver fibrosis assessment? World J Gastroenterol 2011; 17: 3824-3829.
    • (2011) World J Gastroenterol , vol.17 , pp. 3824-3829
    • Sporea, I.1    Sirli, R.2    Popescu, A.3
  • 21
    • 82955233891 scopus 로고    scopus 로고
    • Comparison of transient elastography and acoustic radiation force impulse for non-invasive staging of liver fibrosis in patients with chronic hepatitis C
    • Rizzo L, Calvaruso V, Cacopardo B, et al. Comparison of transient elastography and acoustic radiation force impulse for non-invasive staging of liver fibrosis in patients with chronic hepatitis C. Am J Gastroenterol 2011; 106: 2112-2120.
    • (2011) Am J Gastroenterol , vol.106 , pp. 2112-2120
    • Rizzo, L.1    Calvaruso, V.2    Cacopardo, B.3
  • 22
    • 84874473244 scopus 로고    scopus 로고
    • Determination of reliability criteria for liver stiffness evaluation by transient elastography
    • Multicentric Group from ANRS/HC/EP23 FIBROSTAR Studies.
    • Boursier J, Zarski JP, de Ledinghen V, et al; Multicentric Group from ANRS/HC/EP23 FIBROSTAR Studies. Determination of reliability criteria for liver stiffness evaluation by transient elastography. Hepatology 2013; 57: 1182-1191.
    • (2013) Hepatology , vol.57 , pp. 1182-1191
    • Boursier, J.1    Zarski, J.P.2    de Ledinghen, V.3
  • 23
    • 80052737747 scopus 로고    scopus 로고
    • Factors that influence the correlation of acoustic radiation force impulse (ARFI), elastography with liver fibrosis
    • Bota S, Sporea I, Sirli R, Popescu A, Danila M, Sendroiu M. Factors that influence the correlation of acoustic radiation force impulse (ARFI), elastography with liver fibrosis. Med Ultrason 2011; 13: 135-140.
    • (2011) Med Ultrason , vol.13 , pp. 135-140
    • Bota, S.1    Sporea, I.2    Sirli, R.3    Popescu, A.4    Danila, M.5    Sendroiu, M.6
  • 24
    • 84873527067 scopus 로고    scopus 로고
    • Factors which influence the accuracy of acoustic radiation force impulse (ARFI) elastography for the diagnosis of liver fibrosis in patients with chronic hepatitis C
    • Bota S, Sporea I, Sirli R, Popescu A, Jurchis A. Factors which influence the accuracy of acoustic radiation force impulse (ARFI) elastography for the diagnosis of liver fibrosis in patients with chronic hepatitis C. Ultrasound Med Biol 2013; 39: 407-412.
    • (2013) Ultrasound Med Biol , vol.39 , pp. 407-412
    • Bota, S.1    Sporea, I.2    Sirli, R.3    Popescu, A.4    Jurchis, A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.