-
1
-
-
63349097089
-
Liver biopsy
-
American Association for the Study of Liver Diseases.
-
Rockey DC, Caldwell SH, Goodman ZD, Nelson RC, Smith AD; American Association for the Study of Liver Diseases. Liver biopsy. Hepatology. 2009; 49: 1017-1044.
-
(2009)
Hepatology.
, vol.49
, pp. 1017-1044
-
-
Rockey, D.C.1
Caldwell, S.H.2
Goodman, Z.D.3
Nelson, R.C.4
Smith, A.D.5
-
2
-
-
79960453276
-
EASL Clinical Practice Guidelines: management of hepatitis C virus infection
-
European Association for the Study of the Liver.
-
European Association for the Study of the Liver. EASL Clinical Practice Guidelines: management of hepatitis C virus infection. J Hepatol 2011; 55: 245-264.
-
(2011)
J Hepatol
, vol.55
, pp. 245-264
-
-
-
3
-
-
84876116484
-
EFSUMB Guidelines and recommendations on the clinical use of ultrasound elastography. Part 1: Basic principles and technology
-
Bamber J, Cosgrove D, Dietrich C.F, et al. EFSUMB Guidelines and recommendations on the clinical use of ultrasound elastography. Part 1: Basic principles and technology. Ultraschall Med. 2013; 34: 169-184.
-
(2013)
Ultraschall Med.
, vol.34
, pp. 169-184
-
-
Bamber, J.1
Cosgrove, D.2
Dietrich, C.F.3
-
4
-
-
84878241671
-
EFSUMB guidelines and recommendations on the clinical use of ultrasound elastography. Part 2: Clinical applications
-
Cosgrove D, Piscaglia F, Bamber J, et al. EFSUMB guidelines and recommendations on the clinical use of ultrasound elastography. Part 2: Clinical applications. Ultraschall Med. 2013; 34: 238-253.
-
(2013)
Ultraschall Med.
, vol.34
, pp. 238-253
-
-
Cosgrove, D.1
Piscaglia, F.2
Bamber, J.3
-
5
-
-
84862664371
-
EASL clinical practice guidelines: Management of chronic hepatitis B virus infection
-
European Association for the Study of the Liver.
-
European Association for the Study of the Liver. EASL clinical practice guidelines: Management of chronic hepatitis B virus infection. J Hepatol 2012; 57: 167-185.
-
(2012)
J Hepatol
, vol.57
, pp. 167-185
-
-
-
6
-
-
84881552256
-
Meta-analysis: ARFI elastography versus transient elastography for the evaluation of liver fibrosis
-
Bota S, Herkner H, Sporea I, et al. Meta-analysis: ARFI elastography versus transient elastography for the evaluation of liver fibrosis. Liver Int. 2013; 33: 1138-1147.
-
(2013)
Liver Int.
, vol.33
, pp. 1138-1147
-
-
Bota, S.1
Herkner, H.2
Sporea, I.3
-
7
-
-
79960933101
-
Noninvasive in vivo liver fibrosis evaluation using supersonic shear imaging: a clinical study on 113 hepatitis C virus patients
-
Bavu E, Gennisson JL, Couade M, et al. Noninvasive in vivo liver fibrosis evaluation using supersonic shear imaging: a clinical study on 113 hepatitis C virus patients. Ultrasound Med Biol 2011; 37: 1361-1373.
-
(2011)
Ultrasound Med Biol
, vol.37
, pp. 1361-1373
-
-
Bavu, E.1
Gennisson, J.L.2
Couade, M.3
-
8
-
-
84870530814
-
Accuracy of real-time shear wave elastography for assessing liver fibrosis in chronic hepatitis C: a pilot study
-
Liver Fibrosis Study Group.
-
Ferraioli G, Tinelli C, Dal Bello B, Zicchetti M, Filice G, Filice C; Liver Fibrosis Study Group. Accuracy of real-time shear wave elastography for assessing liver fibrosis in chronic hepatitis C: a pilot study. Hepatology 2012; 56:2125-2133.
-
(2012)
Hepatology
, vol.56
, pp. 2125-2133
-
-
Ferraioli, G.1
Tinelli, C.2
Dal Bello, B.3
Zicchetti, M.4
Filice, G.5
Filice, C.6
-
9
-
-
84876289848
-
Liver fibrosis evaluation using real-time shear wave elastography: applicability and diagnostic performance using methods without a gold standard
-
Poynard T, Munteanu M, Luckina E, et al. Liver fibrosis evaluation using real-time shear wave elastography: applicability and diagnostic performance using methods without a gold standard. J Hepatol 2013; 58: 928-935.
-
(2013)
J Hepatol
, vol.58
, pp. 928-935
-
-
Poynard, T.1
Munteanu, M.2
Luckina, E.3
-
10
-
-
84884532167
-
Acoustic radiation force impulse and supersonic shear imaging versus transient elastography for liver fibrosis assessment
-
Sporea I, Bota S, Jurchis A, et al. Acoustic radiation force impulse and supersonic shear imaging versus transient elastography for liver fibrosis assessment. Ultrasound Med Biol 2013; 39: 1933-1941.
-
(2013)
Ultrasound Med Biol
, vol.39
, pp. 1933-1941
-
-
Sporea, I.1
Bota, S.2
Jurchis, A.3
-
11
-
-
84874775131
-
Staging of hepatic fibrosis: comparison of magnetic resonance elastography and shear wave elastography in the same individuals
-
Yoon JH, Lee JM, Woo HS, et al. Staging of hepatic fibrosis: comparison of magnetic resonance elastography and shear wave elastography in the same individuals. Korean J Radiol 2013; 14: 202-212.
-
(2013)
Korean J Radiol
, vol.14
, pp. 202-212
-
-
Yoon, J.H.1
Lee, J.M.2
Woo, H.S.3
-
12
-
-
84888790657
-
Quantitative Elastography of Liver Fibrosis and Spleen Stiffness in Chronic Hepatitis B Carriers: Comparison of Shear-Wave Elastography and Transient Elastography with Liver Biopsy Correlation
-
Aug 2. [Epub ahead of print]
-
Leung VY, Shen J, Wong VW, et al. Quantitative Elastography of Liver Fibrosis and Spleen Stiffness in Chronic Hepatitis B Carriers: Comparison of Shear-Wave Elastography and Transient Elastography with Liver Biopsy Correlation. Radiology 2013 Aug 2. [Epub ahead of print]
-
(2013)
Radiology
-
-
Leung, V.Y.1
Shen, J.2
Wong, V.W.3
-
13
-
-
77950619459
-
Pitfalls of liver stiffness measurement: a 5-year prospective study of 13,369 examinations
-
Castéra L, Foucher J, Bernard PH, et al. Pitfalls of liver stiffness measurement: a 5-year prospective study of 13,369 examinations. Hepatology 2010; 51: 828-835.
-
(2010)
Hepatology
, vol.51
, pp. 828-835
-
-
Castéra, L.1
Foucher, J.2
Bernard, P.H.3
-
14
-
-
10444241032
-
The role of viscosity in the impulse diffraction field of elastic waves induced by the acoustic radiation force
-
BercoffJ, Tanter M, Muller M, Fink M. The role of viscosity in the impulse diffraction field of elastic waves induced by the acoustic radiation force. IEEE Trans Ultrason Ferroelectr Freq Control 2004; 51: 1523-1536.
-
(2004)
IEEE Trans Ultrason Ferroelectr Freq Control
, vol.51
, pp. 1523-1536
-
-
Bercoff, J.1
Tanter, M.2
Muller, M.3
Fink, M.4
-
15
-
-
78751515404
-
Acoustic radiation force impulse elastography as compared to transient elastography and liver biopsy in patients with chronic hepatopathies
-
Sporea I, Sirli RL, Deleanu A, et al. Acoustic radiation force impulse elastography as compared to transient elastography and liver biopsy in patients with chronic hepatopathies. Ultraschall Med 2011; 32 (Suppl 1): S46-S52.
-
(2011)
Ultraschall Med
, vol.32
, Issue.SUPPL. 1
-
-
Sporea, I.1
Sirli, R.L.2
Deleanu, A.3
-
16
-
-
79953782212
-
Accuracy of VirtualTouch Acoustic Radiation Force Impulse (ARFI) imaging for the diagnosis of cirrhosis during liver ultrasonography
-
Piscaglia F, Salvatore V, Di Donato R, et al. Accuracy of VirtualTouch Acoustic Radiation Force Impulse (ARFI) imaging for the diagnosis of cirrhosis during liver ultrasonography. Ultraschall Med 2011; 32: 167-175.
-
(2011)
Ultraschall Med
, vol.32
, pp. 167-175
-
-
Piscaglia, F.1
Salvatore, V.2
Di Donato, R.3
-
17
-
-
70249130127
-
Liver fibrosis in viral hepatitis: noninvasive assessment with acoustic radiation force impulse imaging versus transient elastography
-
Friedrich-Rust M, Wunder K, Kriener S, et al. Liver fibrosis in viral hepatitis: noninvasive assessment with acoustic radiation force impulse imaging versus transient elastography. Radiology 2009; 252: 595-604.
-
(2009)
Radiology
, vol.252
, pp. 595-604
-
-
Friedrich-Rust, M.1
Wunder, K.2
Kriener, S.3
-
18
-
-
85027943357
-
Evaluation of liver fibrosis by transient elastography using acoustic radiation force impulse: comparison with Fibroscan(®)
-
Ebinuma H, Saito H, Komuta M, et al. Evaluation of liver fibrosis by transient elastography using acoustic radiation force impulse: comparison with Fibroscan(®). J Gastroenterol 2011; 46: 1238-1248.
-
(2011)
J Gastroenterol
, vol.46
, pp. 1238-1248
-
-
Ebinuma, H.1
Saito, H.2
Komuta, M.3
-
19
-
-
80053912735
-
Is it better to use two elastographic methods for liver fibrosis assessment?
-
Sporea I, Şirli R, Popescu A, et al. Is it better to use two elastographic methods for liver fibrosis assessment? World J Gastroenterol 2011; 17: 3824-3829.
-
(2011)
World J Gastroenterol
, vol.17
, pp. 3824-3829
-
-
Sporea, I.1
Sirli, R.2
Popescu, A.3
-
20
-
-
74049126075
-
Acoustic radiation force imaging sonoelastography for noninvasive staging of liver fibrosis
-
Fierbinteanu-Braticevici C, Andronescu D, Usvat R, Cretoiu D, Baicus C, Marinoschi G. Acoustic radiation force imaging sonoelastography for noninvasive staging of liver fibrosis. World J Gastroenterol 2009; 15: 5525-5532.
-
(2009)
World J Gastroenterol
, vol.15
, pp. 5525-5532
-
-
Fierbinteanu-Braticevici, C.1
Andronescu, D.2
Usvat, R.3
Cretoiu, D.4
Baicus, C.5
Marinoschi, G.6
-
21
-
-
82955233891
-
Comparison of transient elastography and acoustic radiation force impulse for non-invasive staging of liver fibrosis in patients with chronic hepatitis C
-
Rizzo L, Calvaruso V, Cacopardo B, et al. Comparison of transient elastography and acoustic radiation force impulse for non-invasive staging of liver fibrosis in patients with chronic hepatitis C. Am J Gastroenterol 2011; 106: 2112-2120.
-
(2011)
Am J Gastroenterol
, vol.106
, pp. 2112-2120
-
-
Rizzo, L.1
Calvaruso, V.2
Cacopardo, B.3
-
22
-
-
84874473244
-
Determination of reliability criteria for liver stiffness evaluation by transient elastography
-
Multicentric Group from ANRS/HC/EP23 FIBROSTAR Studies.
-
Boursier J, Zarski JP, de Ledinghen V, et al; Multicentric Group from ANRS/HC/EP23 FIBROSTAR Studies. Determination of reliability criteria for liver stiffness evaluation by transient elastography. Hepatology 2013; 57: 1182-1191.
-
(2013)
Hepatology
, vol.57
, pp. 1182-1191
-
-
Boursier, J.1
Zarski, J.P.2
de Ledinghen, V.3
-
23
-
-
80052737747
-
Factors that influence the correlation of acoustic radiation force impulse (ARFI), elastography with liver fibrosis
-
Bota S, Sporea I, Sirli R, Popescu A, Danila M, Sendroiu M. Factors that influence the correlation of acoustic radiation force impulse (ARFI), elastography with liver fibrosis. Med Ultrason 2011; 13: 135-140.
-
(2011)
Med Ultrason
, vol.13
, pp. 135-140
-
-
Bota, S.1
Sporea, I.2
Sirli, R.3
Popescu, A.4
Danila, M.5
Sendroiu, M.6
-
24
-
-
84873527067
-
Factors which influence the accuracy of acoustic radiation force impulse (ARFI) elastography for the diagnosis of liver fibrosis in patients with chronic hepatitis C
-
Bota S, Sporea I, Sirli R, Popescu A, Jurchis A. Factors which influence the accuracy of acoustic radiation force impulse (ARFI) elastography for the diagnosis of liver fibrosis in patients with chronic hepatitis C. Ultrasound Med Biol 2013; 39: 407-412.
-
(2013)
Ultrasound Med Biol
, vol.39
, pp. 407-412
-
-
Bota, S.1
Sporea, I.2
Sirli, R.3
Popescu, A.4
Jurchis, A.5
|