메뉴 건너뛰기




Volumn 82, Issue 6, 2013, Pages 1436-1439

Safety of the "drain and retain" option for defunctionalized urologic prosthetic balloons and reservoirs during artificial urinary sphincter and inflatable penile prosthesis revision surgery: 5-year experience

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; BLADDER SPHINCTER PROSTHESIS; CHI SQUARE DISTRIBUTION; CONTROLLED STUDY; DEVICE EROSION; DEVICE HERNIATION; DEVICE REMOVAL; DRAIN AND RETAIN TECHNIQUE; GROIN TENDERNESS; HUMAN; INFLATABLE PENIS PROSTHESIS; MAJOR CLINICAL STUDY; MALE; POSTOPERATIVE COMPLICATION; POSTOPERATIVE INFECTION; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; PROCEDURES; PROSTHESIS FAILURE; REOPERATION; SAFETY; TREATMENT OUTCOME; UROLOGIC PROSTHETIC BALLOON AND RESERVOIR; UROLOGICAL PROSTHESIS;

EID: 84888646572     PISSN: 00904295     EISSN: 15279995     Source Type: Journal    
DOI: 10.1016/j.urology.2013.07.038     Document Type: Article
Times cited : (31)

References (19)
  • 1
    • 0033911309 scopus 로고    scopus 로고
    • Efficacy, safety and patient satisfaction outcomes of the AMS 700CX inflatable penile prosthesis: Results of a long-term multicenter study. AMS 700CX Study Group
    • C.C. Carson, J.J. Mulcahy, and F.E. Govier Efficacy, safety and patient satisfaction outcomes of the AMS 700CX inflatable penile prosthesis: results of a long-term multicenter study. AMS 700CX Study Group J Urol 164 2000 376 380
    • (2000) J Urol , vol.164 , pp. 376-380
    • Carson, C.C.1    Mulcahy, J.J.2    Govier, F.E.3
  • 2
    • 0034796553 scopus 로고    scopus 로고
    • Artificial urinary sphincter for post-radical prostatectomy urinary incontinence: Long-term subjective results
    • A.E. Gousse, S. Madjar, M.M. Lambert, and I.J. Fishman Artificial urinary sphincter for post-radical prostatectomy urinary incontinence: long-term subjective results J Urol 166 2001 1755 1758
    • (2001) J Urol , vol.166 , pp. 1755-1758
    • Gousse, A.E.1    Madjar, S.2    Lambert, M.M.3    Fishman, I.J.4
  • 3
    • 0034940991 scopus 로고    scopus 로고
    • Long-term continence and patient satisfaction after artificial sphincter implantation for urinary incontinence after prostatectomy
    • D.K. Montague, K.W. Angermeier, and D.R. Paolone Long-term continence and patient satisfaction after artificial sphincter implantation for urinary incontinence after prostatectomy J Urol 166 2001 547 549
    • (2001) J Urol , vol.166 , pp. 547-549
    • Montague, D.K.1    Angermeier, K.W.2    Paolone, D.R.3
  • 4
    • 0036144871 scopus 로고    scopus 로고
    • Artificial urinary sphincter for post-prostatectomy incontinence in men who had prior radiotherapy: A risk and outcome analysis
    • M.A. Gomha, and T.B. Boone Artificial urinary sphincter for post-prostatectomy incontinence in men who had prior radiotherapy: a risk and outcome analysis J Urol 167 2002 591 596
    • (2002) J Urol , vol.167 , pp. 591-596
    • Gomha, M.A.1    Boone, T.B.2
  • 5
    • 34447513761 scopus 로고    scopus 로고
    • Long-term survival of inflatable penile prostheses: Single surgical group experience with 2,384 first-time implants spanning two decades
    • S.K. Wilson, J.R. Delk, E.A. Salem, and M.A. Cleves Long-term survival of inflatable penile prostheses: single surgical group experience with 2,384 first-time implants spanning two decades J Sex Med 4 2007 1074 1079
    • (2007) J Sex Med , vol.4 , pp. 1074-1079
    • Wilson, S.K.1    Delk, J.R.2    Salem, E.A.3    Cleves, M.A.4
  • 6
    • 84855339772 scopus 로고    scopus 로고
    • An outcomes analysis of over 200 revision surgeries for penile prosthesis implantation: A multicenter study
    • G.D. Henry, C.F. Donatucci, and W. Conners An outcomes analysis of over 200 revision surgeries for penile prosthesis implantation: a multicenter study J Sex Med 9 2012 309 315
    • (2012) J Sex Med , vol.9 , pp. 309-315
    • Henry, G.D.1    Donatucci, C.F.2    Conners, W.3
  • 7
    • 84888637934 scopus 로고    scopus 로고
    • Intentionally retained pressure-regulating balloon in artificial urinary sphincter revision
    • T.S. Köhler, A. Benson, and L. Ost Intentionally retained pressure-regulating balloon in artificial urinary sphincter revision J Sex Med 2012
    • (2012) J Sex Med
    • Köhler, T.S.1    Benson, A.2    Ost, L.3
  • 8
    • 3142583082 scopus 로고    scopus 로고
    • Fate of the retained reservoir after replacement of 3-piece penile prosthesis
    • A. Rajpurkar, F.F. Bianco Jr., and O. Al-Omar Fate of the retained reservoir after replacement of 3-piece penile prosthesis J Urol 172 2004 664 666
    • (2004) J Urol , vol.172 , pp. 664-666
    • Rajpurkar, A.1    Bianco, Jr.F.F.2    Al-Omar, O.3
  • 9
    • 84873058504 scopus 로고    scopus 로고
    • High submuscular placement of urologic prosthetic balloons and reservoirs via transscrotal approach
    • A.F. Morey, C. Cefalu, and S.J. Hudak High submuscular placement of urologic prosthetic balloons and reservoirs via transscrotal approach J Sex Med 10 2013 603 610
    • (2013) J Sex Med , vol.10 , pp. 603-610
    • Morey, A.F.1    Cefalu, C.2    Hudak, S.J.3
  • 10
    • 40849092410 scopus 로고    scopus 로고
    • Best practice policy statement on urologic surgery antimicrobial prophylaxis
    • J.S. Wolf Jr., C. Bennett, and R.R. Dmochowski Best practice policy statement on urologic surgery antimicrobial prophylaxis J Urol 179 2008 1379 1390
    • (2008) J Urol , vol.179 , pp. 1379-1390
    • Wolf, Jr.J.S.1    Bennett, C.2    Dmochowski, R.R.3
  • 11
    • 84868215092 scopus 로고    scopus 로고
    • Review of penile prosthetic reservoir: Complications and presentation of a modified reservoir placement technique
    • L.A. Levine, and M.P. Hoeh Review of penile prosthetic reservoir: complications and presentation of a modified reservoir placement technique J Sex Med 9 2012 2759 2769
    • (2012) J Sex Med , vol.9 , pp. 2759-2769
    • Levine, L.A.1    Hoeh, M.P.2
  • 12
    • 44649099497 scopus 로고    scopus 로고
    • Unilateral ureteral obstruction due to a migrated inflatable penile prosthesis reservoir
    • S.J. Hudak, and R.V. Mora Unilateral ureteral obstruction due to a migrated inflatable penile prosthesis reservoir J Urol 180 2008 336
    • (2008) J Urol , vol.180 , pp. 336
    • Hudak, S.J.1    Mora, R.V.2
  • 13
    • 0343673784 scopus 로고    scopus 로고
    • The retained penile prosthesis reservoir: A risk
    • J.J. Munoz, and P. Ellsworth The retained penile prosthesis reservoir: a risk Urology 55 2000 949
    • (2000) Urology , vol.55 , pp. 949
    • Munoz, J.J.1    Ellsworth, P.2
  • 14
    • 3142581640 scopus 로고    scopus 로고
    • The retained reservoir in inflatable penile prosthesis explantation
    • L. Jones, R. Ryan, A. Ghobriel, and S.K. Wilson The retained reservoir in inflatable penile prosthesis explantation J Urol 167 2002 601
    • (2002) J Urol , vol.167 , pp. 601
    • Jones, L.1    Ryan, R.2    Ghobriel, A.3    Wilson, S.K.4
  • 15
    • 33646556711 scopus 로고    scopus 로고
    • Compression of ureter caused by a retained reservoir of penile prosthesis
    • B.P. Jiann, C.W. Ou, J.T. Lin, and J.K. Huang Compression of ureter caused by a retained reservoir of penile prosthesis Int J Impot Res 18 2006 316 317
    • (2006) Int J Impot Res , vol.18 , pp. 316-317
    • Jiann, B.P.1    Ou, C.W.2    Lin, J.T.3    Huang, J.K.4
  • 16
    • 84867388811 scopus 로고    scopus 로고
    • Dilemmas of inflatable penile prosthesis revision surgery: What practices achieve the best outcomes and the lowest infection rates? (CME)
    • P.R. Hinds, S.K. Wilson, and H. Sadeghi-Nejad Dilemmas of inflatable penile prosthesis revision surgery: what practices achieve the best outcomes and the lowest infection rates? (CME) J Sex Med 9 2012 2483 2492
    • (2012) J Sex Med , vol.9 , pp. 2483-2492
    • Hinds, P.R.1    Wilson, S.K.2    Sadeghi-Nejad, H.3
  • 17
    • 84857533638 scopus 로고    scopus 로고
    • A purely laparoscopic approach to intra-abdominal abscess drainage and retrieval of retained penile prosthesis reservoir
    • T.M. Shary, and R.C. Pullatt A purely laparoscopic approach to intra-abdominal abscess drainage and retrieval of retained penile prosthesis reservoir Am Surg 78 2012 162 163
    • (2012) Am Surg , vol.78 , pp. 162-163
    • Shary, T.M.1    Pullatt, R.C.2
  • 18
    • 78651266469 scopus 로고    scopus 로고
    • Long-term infection outcomes after original antibiotic impregnated inflatable penile prosthesis implants: Up to 7.7 years of followup
    • C.C. Carson 3rd, J.J. Mulcahy, and M.R. Harsch Long-term infection outcomes after original antibiotic impregnated inflatable penile prosthesis implants: up to 7.7 years of followup J Urol 185 2011 614 618
    • (2011) J Urol , vol.185 , pp. 614-618
    • Carson III, C.C.1    Mulcahy, J.J.2    Harsch, M.R.3
  • 19
    • 41749096338 scopus 로고    scopus 로고
    • Long-term durability and functional outcomes among patients with artificial urinary sphincters: A 10-year retrospective review from the University of Michigan
    • S.P. Kim, Z. Sarmast, and S. Daignault Long-term durability and functional outcomes among patients with artificial urinary sphincters: a 10-year retrospective review from the University of Michigan J Urol 179 2008 1912 1916
    • (2008) J Urol , vol.179 , pp. 1912-1916
    • Kim, S.P.1    Sarmast, Z.2    Daignault, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.