-
2
-
-
33845939947
-
The new wave of ion-selective electrodes
-
E. Pretsch The new wave of ion-selective electrodes Trends in Analytical Chemistry 26 2007 46
-
(2007)
Trends in Analytical Chemistry
, vol.26
, pp. 46
-
-
Pretsch, E.1
-
3
-
-
0000722089
-
Effect of transmembrane electrolyte diffusion on the detection limit of carrier-based potentiometric ion sensors
-
S. Mathison, and E. Bakker Effect of transmembrane electrolyte diffusion on the detection limit of carrier-based potentiometric ion sensors Analytical Chemistry 70 1998 303
-
(1998)
Analytical Chemistry
, vol.70
, pp. 303
-
-
Mathison, S.1
Bakker, E.2
-
4
-
-
0035326405
-
Direct evidence of ionic fluxes across ion-selective membranes: A scanning electrochemical microscopic and potentiometric study
-
R.E. Gyurcsanyi, E. Pergel, R. Nagy, I. Kapui, B.T.T. Lan, K. Toth, I. Bitter, and E. Lindner Direct evidence of ionic fluxes across ion-selective membranes: a scanning electrochemical microscopic and potentiometric study Analytical Chemistry 73 2001 2104
-
(2001)
Analytical Chemistry
, vol.73
, pp. 2104
-
-
Gyurcsanyi, R.E.1
Pergel, E.2
Nagy, R.3
Kapui, I.4
Lan, B.T.T.5
Toth, K.6
Bitter, I.7
Lindner, E.8
-
5
-
-
84888296355
-
Making use of ion fluxes through potentiometric sensor membranes: ISEs with step responses at critical ion activities
-
T. Vigassy, W.E. Morf, M. Badertscher, A. Ceresa, N.F. de Rooij, and E. Pretsch Making use of ion fluxes through potentiometric sensor membranes: ISEs with step responses at critical ion activities Sensors and Actuators B 3796 2001 1
-
(2001)
Sensors and Actuators B
, vol.3796
, pp. 1
-
-
Vigassy, T.1
Morf, W.E.2
Badertscher, M.3
Ceresa, A.4
De Rooij, N.F.5
Pretsch, E.6
-
6
-
-
33746611667
-
Approaches to improving the lower detection limit of polymeric membrane ion-selective electrodes
-
Z. Szigeti, T. Vigassy, E. Bakker, and E. Pretsch Approaches to improving the lower detection limit of polymeric membrane ion-selective electrodes Electroanalysis 18 2006 1254
-
(2006)
Electroanalysis
, vol.18
, pp. 1254
-
-
Szigeti, Z.1
Vigassy, T.2
Bakker, E.3
Pretsch, E.4
-
7
-
-
84861865706
-
All-solid-state ion selective and all-solid-state reference electrodes
-
A. Michalska All-solid-state ion selective and all-solid-state reference electrodes Electroanalysis 24 2012 1253
-
(2012)
Electroanalysis
, vol.24
, pp. 1253
-
-
Michalska, A.1
-
8
-
-
0000283739
-
Tailored transport through ion-selective membranes for improved detection limits and selectivity coefficients
-
E. Lindner, R.E. Gyurcsanyi, and R.P. Buck Tailored transport through ion-selective membranes for improved detection limits and selectivity coefficients Electroanalysis 11 1999 695
-
(1999)
Electroanalysis
, vol.11
, pp. 695
-
-
Lindner, E.1
Gyurcsanyi, R.E.2
Buck, R.P.3
-
9
-
-
0037123926
-
Effects of controlled current on the response behavior of polymeric membrane ion-selective electrodes
-
W.E. Morf, M. Badertscher, T. Zwickl, N.F. de Rooij, and E. Pretsch Effects of controlled current on the response behavior of polymeric membrane ion-selective electrodes Journal of Electroanalytical Chemistry 526 2002 19
-
(2002)
Journal of Electroanalytical Chemistry
, vol.526
, pp. 19
-
-
Morf, W.E.1
Badertscher, M.2
Zwickl, T.3
De Rooij, N.F.4
Pretsch, E.5
-
13
-
-
78650596657
-
Drastic improvement of the lower detection limit of ion-selective electrodes by tuned galvanostatic polarization
-
(in Russian)
-
M.A. Peshkova, T. Sokalski, K.N. Mikhelson, and A. Lewenstam Drastic improvement of the lower detection limit of ion-selective electrodes by tuned galvanostatic polarization Herald of St. Petersburg University 1 2010 106 (in Russian)
-
(2010)
Herald of St. Petersburg University
, vol.1
, pp. 106
-
-
Peshkova, M.A.1
Sokalski, T.2
Mikhelson, K.N.3
Lewenstam, A.4
-
14
-
-
80054968756
-
Tuned galvanostatic polarization of solid-state lead-selective electrodes for lowering of the detection limit
-
G. Lisak, T. Sokalski, J. Bobacka, L. Harju, K. Mikhelson, and A. Lewenstam Tuned galvanostatic polarization of solid-state lead-selective electrodes for lowering of the detection limit Analytica Chimica Acta 707 2011 1
-
(2011)
Analytica Chimica Acta
, vol.707
, pp. 1
-
-
Lisak, G.1
Sokalski, T.2
Bobacka, J.3
Harju, L.4
Mikhelson, K.5
Lewenstam, A.6
-
15
-
-
84872547646
-
Determination of lead(II) in groundwater using solid-state lead(II) selective electrodes by tuned galvanostatic polarization
-
G. Lisak, F. Ciepiela, J. Bobacka, T. Sokalski, L. Harju, and A. Lewenstam Determination of lead(II) in groundwater using solid-state lead(II) selective electrodes by tuned galvanostatic polarization Electroanalysis 25 2013 123
-
(2013)
Electroanalysis
, vol.25
, pp. 123
-
-
Lisak, G.1
Ciepiela, F.2
Bobacka, J.3
Sokalski, T.4
Harju, L.5
Lewenstam, A.6
-
16
-
-
66149085264
-
Limitations of current polarization for lowering the detection limit of potentiometric polymeric membrane sensors
-
L. Hofler, I. Bedlechowicz, T. Vigassy, R.E. Gyurcsanyi, E. Bakker, and E. Pretsch Limitations of current polarization for lowering the detection limit of potentiometric polymeric membrane sensors Analytical Chemistry 81 2009 3592
-
(2009)
Analytical Chemistry
, vol.81
, pp. 3592
-
-
Hofler, L.1
Bedlechowicz, I.2
Vigassy, T.3
Gyurcsanyi, R.E.4
Bakker, E.5
Pretsch, E.6
-
17
-
-
0000188653
-
Oscillographic polarographic waves for the reversible deposition of metals on solid electrodes
-
T. Berzins, and P. Delahay Oscillographic polarographic waves for the reversible deposition of metals on solid electrodes Journal of the American Chemical Society 77 1955 6448
-
(1955)
Journal of the American Chemical Society
, vol.77
, pp. 6448
-
-
Berzins, T.1
Delahay, P.2
-
18
-
-
0038718848
-
How do pulsed amperometric ion sensors work? A simple PDE model
-
E. Bakker, and A.J. Meir How do pulsed amperometric ion sensors work? A simple PDE model SIAM Review 45 2003 327
-
(2003)
SIAM Review
, vol.45
, pp. 327
-
-
Bakker, E.1
Meir, A.J.2
-
19
-
-
67649998678
-
Reverse current pulse method to restore uniform concentration profiles in ion-selective membranes. 1. Galvanostatic pulse methods with decreased cycle time
-
J.M. Zook, and E. Lindner Reverse current pulse method to restore uniform concentration profiles in ion-selective membranes. 1. Galvanostatic pulse methods with decreased cycle time Analytical Chemistry 81 2009 5146
-
(2009)
Analytical Chemistry
, vol.81
, pp. 5146
-
-
Zook, J.M.1
Lindner, E.2
-
21
-
-
0000854354
-
Determination of unbiased selectivity coefficients of neutral carrier-based cation-selective electrodes
-
E. Bakker Determination of unbiased selectivity coefficients of neutral carrier-based cation-selective electrodes Analytical Chemistry 69 1997 1061
-
(1997)
Analytical Chemistry
, vol.69
, pp. 1061
-
-
Bakker, E.1
-
22
-
-
0033560098
-
Lowering the detection limit of solvent polymeric ion-selective electrodes. 2. Influence of composition of sample and internal electrolyte solution
-
T. Sokalski, A. Ceresa, M. Fibbioli, T. Zwickl, E. Bakker, and E. Pretsch Lowering the detection limit of solvent polymeric ion-selective electrodes. 2. Influence of composition of sample and internal electrolyte solution Analytical Chemistry 71 1999 1210
-
(1999)
Analytical Chemistry
, vol.71
, pp. 1210
-
-
Sokalski, T.1
Ceresa, A.2
Fibbioli, M.3
Zwickl, T.4
Bakker, E.5
Pretsch, E.6
-
23
-
-
84865080797
-
Computer simulations of electrodiffusion problems based on Nernst-Planck and Poisson equations
-
J.J. Jasielec, R. Filipek, K. Szyszkiewicz, J. Fausek, M. Danielewski, and A. Lewenstam Computer simulations of electrodiffusion problems based on Nernst-Planck and Poisson equations Computational Materials Science 63 2012 75
-
(2012)
Computational Materials Science
, vol.63
, pp. 75
-
-
Jasielec, J.J.1
Filipek, R.2
Szyszkiewicz, K.3
Fausek, J.4
Danielewski, M.5
Lewenstam, A.6
|