메뉴 건너뛰기




Volumn 21, Issue 12, 2013, Pages 2667-2673

Changes in the loading of tibial articular cartilage following medial meniscectomy: A finite element analysis study

Author keywords

Finite element analysis; Load bearing; Meniscus; Tibial articular cartilage

Indexed keywords

ARTICLE; ARTICULAR CARTILAGE; BIOMECHANICS; COMPUTER ASSISTED TOMOGRAPHY; FINITE ELEMENT ANALYSIS; HUMAN; KNEE MENISCUS; MECHANICAL STRESS; NUCLEAR MAGNETIC RESONANCE IMAGING; PATHOPHYSIOLOGY; THREE DIMENSIONAL IMAGING; TIBIA;

EID: 84888291417     PISSN: 09422056     EISSN: 14337347     Source Type: Journal    
DOI: 10.1007/s00167-012-2318-6     Document Type: Article
Times cited : (31)

References (39)
  • 1
    • 0021733942 scopus 로고
    • Late degenerative changes after meniscectomy. Factors affecting the knee after operation
    • Allen PR, Denham RA, Swan AV (1984) Late degenerative changes after meniscectomy. Factors affecting the knee after operation. J Bone Joint Surg Br 66: 666-671.
    • (1984) J Bone Joint Surg Br , vol.66 , pp. 666-671
    • Allen, P.R.1    Denham, R.A.2    Swan, A.V.3
  • 2
    • 0021428157 scopus 로고
    • An analysis of the unconfined compression of articular cartilage
    • Armstrong C, Lai W, Mow V (1984) An analysis of the unconfined compression of articular cartilage. J Biomech Eng 106: 165-173.
    • (1984) J Biomech Eng , vol.106 , pp. 165-173
    • Armstrong, C.1    Lai, W.2    Mow, V.3
  • 3
    • 0021213283 scopus 로고
    • A continuous wave technique for the measurement of the elastic properties of cortical bone
    • Ashman RB, Cowin SC, van Buskirk WC, Rice JC (1984) A continuous wave technique for the measurement of the elastic properties of cortical bone. J Biomech 17: 349-361.
    • (1984) J Biomech , vol.17 , pp. 349-361
    • Ashman, R.B.1    Cowin, S.C.2    van Buskirk, W.C.3    Rice, J.C.4
  • 5
    • 0022486674 scopus 로고
    • Meniscal tears: the effect of meniscectomy and of repair on intra-articular contact area and stress in the human knee. A preliminary report
    • Baratz ME, Fu FH, Mengato R (1986) Meniscal tears: the effect of meniscectomy and of repair on intra-articular contact area and stress in the human knee. A preliminary report. Am J Sports Med 14: 270-275.
    • (1986) Am J Sports Med , vol.14 , pp. 270-275
    • Baratz, M.E.1    Fu, F.H.2    Mengato, R.3
  • 8
    • 49649127616 scopus 로고    scopus 로고
    • Influence of an interpositional spacer on the behavior of the tibiafemoral joint: a finite element study
    • Chea S, Taylor M, New A (2008) Influence of an interpositional spacer on the behavior of the tibiafemoral joint: a finite element study. Clin Biomech 23: 1044-1052.
    • (2008) Clin Biomech , vol.23 , pp. 1044-1052
    • Chea, S.1    Taylor, M.2    New, A.3
  • 9
    • 79957718272 scopus 로고    scopus 로고
    • Effect of meniscus replacement fixation technique on restoration of knee contact mechanics and stability
    • D'Lima DD, Chen PC, Kessler O et al (2011) Effect of meniscus replacement fixation technique on restoration of knee contact mechanics and stability. Mol Cell Biomech 8: 123-134.
    • (2011) Mol Cell Biomech , vol.8 , pp. 123-134
    • D'Lima, D.D.1    Chen, P.C.2    Kessler, O.3
  • 10
    • 0033213801 scopus 로고    scopus 로고
    • Contact analysis of biphasic transversely isotropic cartilage layers and correlation with tissue failure
    • Donzelli P, Spilker RS, Ateshian GA, Mow VC (1999) Contact analysis of biphasic transversely isotropic cartilage layers and correlation with tissue failure. J Biomech 32: 1037-1047.
    • (1999) J Biomech , vol.32 , pp. 1037-1047
    • Donzelli, P.1    Spilker, R.S.2    Ateshian, G.A.3    Mow, V.C.4
  • 11
    • 84856722710 scopus 로고    scopus 로고
    • Considerations for reporting finite element analysis studies in biomechanics
    • Erdemir A, Guess TM, Halloran J et al (2012) Considerations for reporting finite element analysis studies in biomechanics. J Biomech 45: 625-633.
    • (2012) J Biomech , vol.45 , pp. 625-633
    • Erdemir, A.1    Guess, T.M.2    Halloran, J.3
  • 12
    • 13544255241 scopus 로고
    • Knee joint changes after meniscectomy
    • Fairbank T (1948) Knee joint changes after meniscectomy. J Bone Joint Surg Am 30: 664-670.
    • (1948) J Bone Joint Surg Am , vol.30 , pp. 664-670
    • Fairbank, T.1
  • 13
    • 0019256214 scopus 로고
    • The contact area and pressure distribution pattern of the knee. A study of normal and osteoarthrotic knee joints
    • Fukubayashi T, Kurosawa H (1980) The contact area and pressure distribution pattern of the knee. A study of normal and osteoarthrotic knee joints. Acta Orthop Scand 51: 871-879.
    • (1980) Acta Orthop Scand , vol.51 , pp. 871-879
    • Fukubayashi, T.1    Kurosawa, H.2
  • 14
    • 79960723883 scopus 로고    scopus 로고
    • Changes in articular cartilage mechanics with meniscectomy: a novel image-based modeling approach and comparison to patterns of OA
    • Haemer JM, Song Y, Carter DR, Giori NJ (2011) Changes in articular cartilage mechanics with meniscectomy: a novel image-based modeling approach and comparison to patterns of OA. J Biomech 44: 2307-2312.
    • (2011) J Biomech , vol.44 , pp. 2307-2312
    • Haemer, J.M.1    Song, Y.2    Carter, D.R.3    Giori, N.J.4
  • 15
    • 0017259329 scopus 로고
    • Stabilizing mechanisms of the loaded and unloaded knee joint
    • Hsieh HH, Walker PS (1976) Stabilizing mechanisms of the loaded and unloaded knee joint. J Bone Joint Surg Am 58: 87-93.
    • (1976) J Bone Joint Surg Am , vol.58 , pp. 87-93
    • Hsieh, H.H.1    Walker, P.S.2
  • 16
    • 0027291627 scopus 로고
    • In vitro study of contact area and pressure distribution in the human knee after partial and total meniscectomy
    • Ihn JC, Kim SJ, Park IH (1993) In vitro study of contact area and pressure distribution in the human knee after partial and total meniscectomy. Int Orthop 17: 214-218.
    • (1993) Int Orthop , vol.17 , pp. 214-218
    • Ihn, J.C.1    Kim, S.J.2    Park, I.H.3
  • 19
    • 0018824102 scopus 로고
    • Load-bearing mode of the knee joint: physical behavior of the knee joint with or without menisci
    • Kurosawa H, Fukubayashi T, Nakajima H (1980) Load-bearing mode of the knee joint: physical behavior of the knee joint with or without menisci. Clin Orthop Relat Res 149: 283-290.
    • (1980) Clin Orthop Relat Res , vol.149 , pp. 283-290
    • Kurosawa, H.1    Fukubayashi, T.2    Nakajima, H.3
  • 20
    • 33745874381 scopus 로고    scopus 로고
    • Tibiofemoral contact mechanics after serial medial meniscectomies in the human cadaveric knee
    • Lee SJ, Aadalen KJ, Malaviya P et al (2006) Tibiofemoral contact mechanics after serial medial meniscectomies in the human cadaveric knee. Am J Sports Med 34: 1334-1344.
    • (2006) Am J Sports Med , vol.34 , pp. 1334-1344
    • Lee, S.J.1    Aadalen, K.J.2    Malaviya, P.3
  • 21
    • 0036266777 scopus 로고    scopus 로고
    • Experimental biphasic fem determinations of the material properties and hydraulic permeability of the meniscus in tension
    • LeRoux MA, Setton LA (2002) Experimental biphasic fem determinations of the material properties and hydraulic permeability of the meniscus in tension. J Biomech Eng 124: 315-321.
    • (2002) J Biomech Eng , vol.124 , pp. 315-321
    • LeRoux, M.A.1    Setton, L.A.2
  • 22
    • 0020025601 scopus 로고
    • The effect of medial meniscectomy on anterior-posterior motion of the knee
    • Levy IM, Torzilli PA, Warren RF (1982) The effect of medial meniscectomy on anterior-posterior motion of the knee. J Bone Joint Surg Am 64: 883-888.
    • (1982) J Bone Joint Surg Am , vol.64 , pp. 883-888
    • Levy, I.M.1    Torzilli, P.A.2    Warren, R.F.3
  • 23
    • 0033452081 scopus 로고    scopus 로고
    • A validated three-dimensional computational model of a human joint
    • Li G, Gil J, Kanamori A, Woo SL (1999) A validated three-dimensional computational model of a human joint. J Biomech Eng 121: 657-662.
    • (1999) J Biomech Eng , vol.121 , pp. 657-662
    • Li, G.1    Gil, J.2    Kanamori, A.3    Woo, S.L.4
  • 24
    • 0019448774 scopus 로고
    • The geometrical properties of human femur and tibia and their importance for the mechanical behaviour of these bone structures
    • Martens M, VanAudekercke R, DeMeester P, Mulier JC (1981) The geometrical properties of human femur and tibia and their importance for the mechanical behaviour of these bone structures. Arch Orthop Trauma Surg 98: 113-120.
    • (1981) Arch Orthop Trauma Surg , vol.98 , pp. 113-120
    • Martens, M.1    VanAudekercke, R.2    DeMeester, P.3    Mulier, J.C.4
  • 25
  • 28
    • 0031754657 scopus 로고    scopus 로고
    • The menisci of the knee joint. Anatomical and functional characteristics and a rationale for clinical treatment
    • Messner K, Gao J (1998) The menisci of the knee joint. Anatomical and functional characteristics and a rationale for clinical treatment. J Anat 193: 161-178.
    • (1998) J Anat , vol.193 , pp. 161-178
    • Messner, K.1    Gao, J.2
  • 29
    • 17044416416 scopus 로고    scopus 로고
    • Finite element analysis of the effect of meniscal tears and meniscectomies on human knee biomechanics
    • Peña E, Calvo B, Martínez MA, Palanca D, Doblaré M (2005) Finite element analysis of the effect of meniscal tears and meniscectomies on human knee biomechanics. Clin Biomech 20: 498-507.
    • (2005) Clin Biomech , vol.20 , pp. 498-507
    • Peña, E.1    Calvo, B.2    Martínez, M.A.3    Palanca, D.4    Doblaré, M.5
  • 30
    • 0016170096 scopus 로고
    • The mechanical properties of cortical bone
    • Reilly DT, Burstein AH (1974) The mechanical properties of cortical bone. J Bone Joint Surg Am 56: 1001-1022.
    • (1974) J Bone Joint Surg Am , vol.56 , pp. 1001-1022
    • Reilly, D.T.1    Burstein, A.H.2
  • 32
    • 70249121741 scopus 로고    scopus 로고
    • Analysis of partial meniscectomy and ACL reconstruction in knee joint biomechanics under a combined loading
    • Shirazi R, Shirazi-Adl A (2009) Analysis of partial meniscectomy and ACL reconstruction in knee joint biomechanics under a combined loading. Clin Biomech 24: 755-761.
    • (2009) Clin Biomech , vol.24 , pp. 755-761
    • Shirazi, R.1    Shirazi-Adl, A.2
  • 33
    • 75149148679 scopus 로고    scopus 로고
    • The effect of medial meniscectomy and meniscal allograft transplantation on knee and anterior cruciate ligament biomechanics
    • Spang JT, Dang BC, Mazzocca A, Rincon L, Obopilwe E et al (2010) The effect of medial meniscectomy and meniscal allograft transplantation on knee and anterior cruciate ligament biomechanics. Arthroscopy 26: 192-201.
    • (2010) Arthroscopy , vol.26 , pp. 192-201
    • Spang, J.T.1    Dang, B.C.2    Mazzocca, A.3    Rincon, L.4    Obopilwe, E.5
  • 34
    • 49149106469 scopus 로고    scopus 로고
    • Knee joint biomechanics following arthroscopic partial meniscectomy
    • Sturnieks DL, Besier TF, Mills PM et al (2008) Knee joint biomechanics following arthroscopic partial meniscectomy. J Orthop Res 26: 1075-1080.
    • (2008) J Orthop Res , vol.26 , pp. 1075-1080
    • Sturnieks, D.L.1    Besier, T.F.2    Mills, P.M.3
  • 35
    • 84888301192 scopus 로고    scopus 로고
    • The meniscus: biomechanics, kinematics and functions
    • Tandoǧan NR (1997) The meniscus: biomechanics, kinematics and functions. Acta Orthop Traumatol Turc 31: 397-401.
    • (1997) Acta Orthop Traumatol Turc , vol.31 , pp. 397-401
    • Tandoǧan, N.R.1
  • 38
    • 70349653319 scopus 로고    scopus 로고
    • The combined effect of frontal plane tibiofemoral knee angle and meniscectomy on the cartilage contact stresses and strains
    • Yang N, Nayeb-Hashemi H, Canavan PK (2009) The combined effect of frontal plane tibiofemoral knee angle and meniscectomy on the cartilage contact stresses and strains. Ann Biomed Eng 37: 2360-2372.
    • (2009) Ann Biomed Eng , vol.37 , pp. 2360-2372
    • Yang, N.1    Nayeb-Hashemi, H.2    Canavan, P.K.3
  • 39
    • 2342529908 scopus 로고    scopus 로고
    • The birth of the finite element method and of computational mechanics
    • Zienkiewicz OC (2004) The birth of the finite element method and of computational mechanics. Int J Numer Methods Eng 60: 3-10.
    • (2004) Int J Numer Methods Eng , vol.60 , pp. 3-10
    • Zienkiewicz, O.C.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.