메뉴 건너뛰기




Volumn 83, Issue 12, 2013, Pages 1066-1072

Comparable flow cytometry data can be obtained with two types of instruments, Canto II, and Navios. A GEIL study

Author keywords

Cross calibration; Multiparameter flow cytometry; PMS settings; harmonization

Indexed keywords

FC RECEPTOR; FCGR3B PROTEIN, HUMAN; FLUORESCENT DYE; GLYCOSYLPHOSPHATIDYLINOSITOL ANCHORED PROTEIN;

EID: 84888127916     PISSN: 15524922     EISSN: 15524930     Source Type: Journal    
DOI: 10.1002/cyto.a.22404     Document Type: Article
Times cited : (38)

References (9)
  • 1
    • 0030916138 scopus 로고    scopus 로고
    • Reduction of interlaboratory variability in flow cytometric immunophenotyping by standardization of instrument set-up and calibration, and standard list mode data analysis
    • Gratama JW, Kraan J, Adriaansen H, Hooibrink B, Levering W, Reinders P, Van den Beemd MW, Van der Holt B, Bolhuis RL. Reduction of interlaboratory variability in flow cytometric immunophenotyping by standardization of instrument set-up and calibration, and standard list mode data analysis. Cytometry 1997;30:10-22.
    • (1997) Cytometry , vol.30 , pp. 10-22
    • Gratama, J.W.1    Kraan, J.2    Adriaansen, H.3    Hooibrink, B.4    Levering, W.5    Reinders, P.6    Van den Beemd, M.W.7    Van der Holt, B.8    Bolhuis, R.L.9
  • 2
    • 57749190349 scopus 로고    scopus 로고
    • Standardization of platelet-derived microparticle counting using calibrated beads and a Cytomics FC500 routine flow cytometer: a first step towards multicenter studies?
    • Robert S, Poncelet P, Lacroix R, Arnaud L, Giraudo L, Hauchard A, Sampol J, Dignat-George F. Standardization of platelet-derived microparticle counting using calibrated beads and a Cytomics FC500 routine flow cytometer: a first step towards multicenter studies? J Thromb Haemost 2009;7:190-197.
    • (2009) J Thromb Haemost , vol.7 , pp. 190-197
    • Robert, S.1    Poncelet, P.2    Lacroix, R.3    Arnaud, L.4    Giraudo, L.5    Hauchard, A.6    Sampol, J.7    Dignat-George, F.8
  • 3
    • 0030995678 scopus 로고    scopus 로고
    • Prognostic significance of fluorescence intensity of surface marker expression in childhood B-precursor acute lymphoblastic leukemia. A Pediatric Oncology Group Study
    • Borowitz MJ, Shuster J, Carroll AJ, Nash M, Look AT, Camitta B, Mahoney D, Lauer SJ, Pullen DJ. Prognostic significance of fluorescence intensity of surface marker expression in childhood B-precursor acute lymphoblastic leukemia. A Pediatric Oncology Group Study. Blood 1997;89:3960-3966.
    • (1997) Blood , vol.89 , pp. 3960-3966
    • Borowitz, M.J.1    Shuster, J.2    Carroll, A.J.3    Nash, M.4    Look, A.T.5    Camitta, B.6    Mahoney, D.7    Lauer, S.J.8    Pullen, D.J.9
  • 4
    • 73349135684 scopus 로고    scopus 로고
    • Basics of standardization and calibration in cytometry-a review
    • Mittag A, Tárnok A. Basics of standardization and calibration in cytometry-a review. J Biophotonics 2009;2:470-481.
    • (2009) J Biophotonics , vol.2 , pp. 470-481
    • Mittag, A.1    Tárnok, A.2
  • 5
    • 79954450713 scopus 로고    scopus 로고
    • Immunophenotyping of acute leukemia and lymphoproliferative disorders: A consensus proposal of the European LeukemiaNet Work Package 10
    • Béné MC, Nebe T, Bettelheim P, Buldini B, Bumbea H, Kern W, Lacombe F, Lemez P, Marinov I, Matutes E, et al. Immunophenotyping of acute leukemia and lymphoproliferative disorders: A consensus proposal of the European LeukemiaNet Work Package 10. Leukemia 2011;25:567-574.
    • (2011) Leukemia , vol.25 , pp. 567-574
    • Béné, M.C.1    Nebe, T.2    Bettelheim, P.3    Buldini, B.4    Bumbea, H.5    Kern, W.6    Lacombe, F.7    Lemez, P.8    Marinov, I.9    Matutes, E.10
  • 6
    • 74849109932 scopus 로고    scopus 로고
    • Four- and five-color flow cytometry analysis of leukocyte differentiation pathways in normal bone marrow: A reference document based on a systematic approach by the GTLLF and GEIL
    • Arnoulet C, Béné MC, Durrieu F, Feuillard J, Fossat C, Husson B, Jouault H, Maynadié M, Lacombe F. Four- and five-color flow cytometry analysis of leukocyte differentiation pathways in normal bone marrow: A reference document based on a systematic approach by the GTLLF and GEIL. Cytometry Part B Clin Cytom 2010;78B:4-10.
    • (2010) Cytometry Part B Clin Cytom , vol.78 , pp. 4-10
    • Arnoulet, C.1    Béné, M.C.2    Durrieu, F.3    Feuillard, J.4    Fossat, C.5    Husson, B.6    Jouault, H.7    Maynadié, M.8    Lacombe, F.9
  • 8
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 9
    • 42049108395 scopus 로고    scopus 로고
    • Toward quantitative fluorescence measurements with multicolor flow cytometry
    • Wang L, Gaigalas AK, Marti G, Abbasi F, Hoffman RA. Toward quantitative fluorescence measurements with multicolor flow cytometry. Cytometry Part A 2008;73A:279-288.
    • (2008) Cytometry Part A , vol.73 , pp. 279-288
    • Wang, L.1    Gaigalas, A.K.2    Marti, G.3    Abbasi, F.4    Hoffman, R.A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.