메뉴 건너뛰기




Volumn 34, Issue , 2013, Pages 648-669

Stabilisation of the Cathedral of the Blessed Sacrament following the Canterbury earthquakes

Author keywords

Damage assessment; Failure modes; Risk assessment; Safety; Structural failures

Indexed keywords

2011 CHRISTCHURCH EARTHQUAKES; ACTIVE SEISMIC; BUILDING TYPES; DAMAGE ASSESSMENTS; DARFIELD EARTHQUAKES; SEISMIC VULNERABILITY; STRUCTURAL FAILURE;

EID: 84888017528     PISSN: 13506307     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.engfailanal.2013.01.041     Document Type: Article
Times cited : (9)

References (13)
  • 1
    • 80755189593 scopus 로고    scopus 로고
    • Near-source strong ground motions observed in the 22 February 2011 Christchurch earthquake
    • Bradley B., Cubrinovski M. Near-source strong ground motions observed in the 22 February 2011 Christchurch earthquake. Seismolog Res Lett 2011, 82(6):853-865.
    • (2011) Seismolog Res Lett , vol.82 , Issue.6 , pp. 853-865
    • Bradley, B.1    Cubrinovski, M.2
  • 2
    • 84888019687 scopus 로고    scopus 로고
    • Cairns L. Powerless to stop heritage demolition. The Christchurch press. [accessed 15.12.12]; 2012.
    • Cairns L. Powerless to stop heritage demolition. The Christchurch press. [accessed 15.12.12]; 2012. http://www.stuff.co.nz/the-press/news/christchurch-earthquake-2011/8014704/Powerless-to-stop-heritage-demolition.
  • 3
    • 84888057676 scopus 로고    scopus 로고
    • DBH, Building act 1991. Section 66, buildings which are determined to be earthquake prone. Department of building and housing; 1991.
    • DBH, Building act 1991. Section 66, buildings which are determined to be earthquake prone. Department of building and housing; 1991.
  • 5
    • 84888067923 scopus 로고    scopus 로고
    • GNS. Response spectra for accelerogram 20100903_163541_CCCC.
    • GNS. Response spectra for accelerogram 20100903_163541_CCCC. ftp://ftp.geonet.org.nz/strong/processed/Proc/2010/09_Darfield_mainshock_extended_pass_band/Vol3/data/20100903_163541_CCCC.v3a [last accessed 19.07.12]; 2010.
  • 6
    • 84888061430 scopus 로고    scopus 로고
    • GNS. Response spectra for accelerogram 20100903_163541_CCCC.
    • GNS. Response spectra for accelerogram 20100903_163541_CCCC. ftp://ftp.geonet.org.nz/strong/processed/Proc/2011/02_Christchurch_mainshock_extended_pass_band/Vol3/data/20110221_235142_CCCC.v3a [last accessed 19.07.12]; 2011.
  • 7
    • 84888034690 scopus 로고
    • An investigation into New Zealand architectural biography. MA thesis, University of Auckland;
    • Hamilton PR. Francis Petre: 1847-1918. An investigation into New Zealand architectural biography. MA thesis, University of Auckland; 1986.
    • (1986) , pp. 1847-1918
    • Hamilton, P.R.1    Francis, P.2
  • 8
    • 79959260021 scopus 로고    scopus 로고
    • Structural aspects of the conservation of historic masonry constructions in seismic areas: remedial measures and emergency actions
    • Modena C., Valuzzi M.R., da Porto F., Casarin F. Structural aspects of the conservation of historic masonry constructions in seismic areas: remedial measures and emergency actions. Int J Architect Herit: Conserv, Anal Restor 2011, 5(4-5):539-558.
    • (2011) Int J Architect Herit: Conserv, Anal Restor , vol.5 , Issue.4-5 , pp. 539-558
    • Modena, C.1    Valuzzi, M.R.2    da Porto, F.3    Casarin, F.4
  • 9
    • 84888046483 scopus 로고    scopus 로고
    • NZHPT. Cathedral of the Blessed Sacrament (Catholic). [last accessed 18.07.12]
    • NZHPT. Cathedral of the Blessed Sacrament (Catholic). www.historic.org.nz/TheRegister/RegisterSearch/RegisterResults.aspx?RID=47 [last accessed 18.07.12]; 2012.
    • (2012)
  • 10
    • 84888075003 scopus 로고    scopus 로고
    • NZS. NZS 4203:1992. Code of practice for general structural design and design loadings for buildings; code of practice, Standards New Zealand; 1992.
    • NZS. NZS 4203:1992. Code of practice for general structural design and design loadings for buildings; vol. 1: code of practice, Standards New Zealand; 1992.
    • , vol.1
  • 11
    • 84888066972 scopus 로고    scopus 로고
    • NZS. NZS 1170.0, 2002. Structural design actions, part 0: general principles. Standards New Zealand; 2002.
    • NZS. NZS 1170.0, 2002. Structural design actions, part 0: general principles. Standards New Zealand; 2002.
  • 12
    • 84888023397 scopus 로고    scopus 로고
    • An integrated procedure for the assessment of seismic vulnerability of historic buildings. In: 12th European conference on earthquake engineering, 9-13 September London, Paper 561; 2002.
    • D'Ayala D, Speranza E. An integrated procedure for the assessment of seismic vulnerability of historic buildings. In: 12th European conference on earthquake engineering, 9-13 September London, Paper 561; 2002.
    • D'Ayala, D.1    Speranza, E.2
  • 13
    • 84888028509 scopus 로고
    • The Basilicas of F.W. Petre. MA thesis, University of Canterbury;
    • Wynn-Williams DB. The Basilicas of F.W. Petre. MA thesis, University of Canterbury; 1982.
    • (1982)
    • Wynn-Williams, D.B.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.