메뉴 건너뛰기




Volumn 120, Issue 12, 2013, Pages 2517-2524

Imaging the iris with swept-source optical coherence tomography: Relationship between iris volume and primary angle closure

Author keywords

[No Author keywords available]

Indexed keywords

ANGLE OPENING DISTANCE; ANGLE WIDTH; ANTERIOR EYE CHAMBER ANGLE; ANTERIOR EYE CHAMBER VOLUME; ARTICLE; CLINICAL ARTICLE; CONTROLLED STUDY; CROSS-SECTIONAL STUDY; EYE AXIS LENGTH; FEMALE; HUMAN; IRIS VOLUME; LIGHT DARK CYCLE; MALE; OPEN ANGLE GLAUCOMA; OPTICAL COHERENCE TOMOGRAPHY; PRIORITY JOURNAL; PUPIL; SEX DIFFERENCE; TRABECULAR IRIS ANGLE; TRABECULAR IRIS SPACE AREA; VISUAL SYSTEM PARAMETERS; AGED; ANTERIOR EYE SEGMENT; CLOSED ANGLE GLAUCOMA; COLOR VISION; DARK ADAPTATION; DRUG COMBINATION; DRUG EFFECTS; INTRAOCULAR PRESSURE; IRIS; MIDDLE AGED; OBSERVER VARIATION; OCULOPLETHYSMOGRAPHY; PATHOLOGY; REPRODUCIBILITY;

EID: 84888000795     PISSN: 01616420     EISSN: 15494713     Source Type: Journal    
DOI: 10.1016/j.ophtha.2013.05.009     Document Type: Article
Times cited : (77)

References (21)
  • 1
    • 72749112549 scopus 로고    scopus 로고
    • Quantitative iris parameters and association with narrow angles
    • B. Wang, L.M. Sakata, and D.S. Friedman Quantitative iris parameters and association with narrow angles Ophthalmology 117 2010 11 17
    • (2010) Ophthalmology , vol.117 , pp. 11-17
    • Wang, B.1    Sakata, L.M.2    Friedman, D.S.3
  • 2
    • 78650837990 scopus 로고    scopus 로고
    • Increased iris thickness and association with primary angle closure glaucoma
    • B.S. Wang, A. Narayanaswamy, and N. Amerasinghe Increased iris thickness and association with primary angle closure glaucoma Br J Ophthalmol 95 2011 46 50
    • (2011) Br J Ophthalmol , vol.95 , pp. 46-50
    • Wang, B.S.1    Narayanaswamy, A.2    Amerasinghe, N.3
  • 3
    • 72749118730 scopus 로고    scopus 로고
    • Optical coherence tomography quantitative analysis of iris volume changes after pharmacologic mydriasis
    • F. Aptel, and P. Denis Optical coherence tomography quantitative analysis of iris volume changes after pharmacologic mydriasis Ophthalmology 117 2010 3 10
    • (2010) Ophthalmology , vol.117 , pp. 3-10
    • Aptel, F.1    Denis, P.2
  • 4
    • 84871913819 scopus 로고    scopus 로고
    • Biometric evaluation of anterior chamber changes after physiologic pupil dilation using Pentacam and anterior segment optical coherence tomography
    • F. Aptel, C. Chiquet, S. Beccat, and P. Denis Biometric evaluation of anterior chamber changes after physiologic pupil dilation using Pentacam and anterior segment optical coherence tomography Invest Ophthalmol Vis Sci 53 2012 4005 4010
    • (2012) Invest Ophthalmol Vis Sci , vol.53 , pp. 4005-4010
    • Aptel, F.1    Chiquet, C.2    Beccat, S.3    Denis, P.4
  • 5
    • 70350513561 scopus 로고    scopus 로고
    • Angle closure glaucoma-simpler answers to complex mechanisms: LXVI Edward Jackson Memorial Lecture
    • H.A. Quigley Angle closure glaucoma-simpler answers to complex mechanisms: LXVI Edward Jackson Memorial Lecture Am J Ophthalmol 148 2009 657 669
    • (2009) Am J Ophthalmol , vol.148 , pp. 657-669
    • Quigley, H.A.1
  • 6
    • 0037385784 scopus 로고    scopus 로고
    • Five year risk of progression of primary angle closure suspects to primary angle closure: A population based study
    • R. Thomas, R. George, and R. Parikh Five year risk of progression of primary angle closure suspects to primary angle closure: a population based study Br J Ophthalmol 87 2003 450 454
    • (2003) Br J Ophthalmol , vol.87 , pp. 450-454
    • Thomas, R.1    George, R.2    Parikh, R.3
  • 7
    • 84855380696 scopus 로고    scopus 로고
    • Handan Eye Study Group. Prevalence and characteristics of primary angle closure diseases in a rural adult Chinese population: The Handan Eye Study
    • Y. Liang, D.S. Friedman, and Q. Zhou Handan Eye Study Group. Prevalence and characteristics of primary angle closure diseases in a rural adult Chinese population: the Handan Eye Study Invest Ophthalmol Vis Sci 52 2011 8672 8679
    • (2011) Invest Ophthalmol Vis Sci , vol.52 , pp. 8672-8679
    • Liang, Y.1    Friedman, D.S.2    Zhou, Q.3
  • 8
    • 0036158752 scopus 로고    scopus 로고
    • The definition and classification of glaucoma in prevalence surveys
    • P.J. Foster, R. Buhrmann, H.A. Quigley, and G.J. Johnson The definition and classification of glaucoma in prevalence surveys Br J Ophthalmol 86 2002 238 242
    • (2002) Br J Ophthalmol , vol.86 , pp. 238-242
    • Foster, P.J.1    Buhrmann, R.2    Quigley, H.A.3    Johnson, G.J.4
  • 9
    • 2942738905 scopus 로고    scopus 로고
    • High-speed optical frequency-domain imaging
    • Available at: Accessed April 21, 2013
    • S. Yun, G. Tearney, and J. de Boer High-speed optical frequency-domain imaging Opt Express [serial online] 11 2003 2953 2963 Available at: http://www.opticsinfobase.org/oe/abstract.cfm?uri=oe-11-22-2953 Accessed April 21, 2013
    • (2003) Opt Express [Serial Online] , vol.11 , pp. 2953-2963
    • Yun, S.1    Tearney, G.2    De Boer, J.3
  • 10
    • 29244460597 scopus 로고    scopus 로고
    • Three-dimensional and high-speed swept-source optical coherence tomography for in vivo investigation of human anterior eye segments
    • Available at: Accessed April 21, 2013
    • Y. Yasuno, V.D. Madjarova, and S. Makita Three-dimensional and high-speed swept-source optical coherence tomography for in vivo investigation of human anterior eye segments Opt Express [serial online] 13 2005 10652 10664 Available at: http://www.opticsinfobase.org/oe/abstract.cfm?uri=oe-13-26-10652 Accessed April 21, 2013
    • (2005) Opt Express [Serial Online] , vol.13 , pp. 10652-10664
    • Yasuno, Y.1    Madjarova, V.D.2    Makita, S.3
  • 11
    • 0026552857 scopus 로고
    • Ultrasound biomicroscopy of anterior segment structures in normal and glaucomatous eyes
    • C.J. Pavlin, K. Harasiewicz, and F.S. Foster Ultrasound biomicroscopy of anterior segment structures in normal and glaucomatous eyes Am J Ophthalmol 113 1992 381 389
    • (1992) Am J Ophthalmol , vol.113 , pp. 381-389
    • Pavlin, C.J.1    Harasiewicz, K.2    Foster, F.S.3
  • 12
    • 23844543530 scopus 로고    scopus 로고
    • Comparison of optical coherence tomography and ultrasound biomicroscopy for detection of narrow anterior chamber angles
    • S. Radhakrishnan, J. Goldsmith, and D. Huang Comparison of optical coherence tomography and ultrasound biomicroscopy for detection of narrow anterior chamber angles Arch Ophthalmol 123 2005 1053 1059
    • (2005) Arch Ophthalmol , vol.123 , pp. 1053-1059
    • Radhakrishnan, S.1    Goldsmith, J.2    Huang, D.3
  • 13
    • 84855389876 scopus 로고    scopus 로고
    • Anterior chamber angle imaging with swept-source optical coherence tomography: An investigation on variability of angle measurement
    • S. Liu, M. Yu, and C. Ye Anterior chamber angle imaging with swept-source optical coherence tomography: an investigation on variability of angle measurement Invest Ophthalmol Vis Sci 52 2011 8598 8603
    • (2011) Invest Ophthalmol Vis Sci , vol.52 , pp. 8598-8603
    • Liu, S.1    Yu, M.2    Ye, C.3
  • 14
    • 0014759414 scopus 로고
    • Aetiology of the anatomical basis for primary angle closure glaucoma. Biometrical comparisons between normal eyes and eyes with primary angle closure glaucoma
    • R.F. Lowe Aetiology of the anatomical basis for primary angle closure glaucoma. Biometrical comparisons between normal eyes and eyes with primary angle closure glaucoma Br J Ophthalmol 54 1970 161 169
    • (1970) Br J Ophthalmol , vol.54 , pp. 161-169
    • Lowe, R.F.1
  • 15
    • 0031414523 scopus 로고    scopus 로고
    • Biometry and primary angle closure glaucoma among Chinese, white, and black populations
    • N.G. Congdon, Q. Youlin, and H. Quigley Biometry and primary angle closure glaucoma among Chinese, white, and black populations Ophthalmology 104 1997 1489 1495
    • (1997) Ophthalmology , vol.104 , pp. 1489-1495
    • Congdon, N.G.1    Youlin, Q.2    Quigley, H.3
  • 16
    • 84856533763 scopus 로고    scopus 로고
    • Determinants of angle width in Chinese Singaporeans
    • L.L. Foo, M.E. Nongpiur, and J.C. Allen Determinants of angle width in Chinese Singaporeans Ophthalmology 119 2012 278 282
    • (2012) Ophthalmology , vol.119 , pp. 278-282
    • Foo, L.L.1    Nongpiur, M.E.2    Allen, J.C.3
  • 17
    • 65649117736 scopus 로고    scopus 로고
    • Iris cross-sectional area decreases with pupil dilation and its dynamic behavior is a risk factor in angle closure
    • H.A. Quigley, D.M. Silver, and D.S. Friedman Iris cross-sectional area decreases with pupil dilation and its dynamic behavior is a risk factor in angle closure J Glaucoma 18 2009 173 179
    • (2009) J Glaucoma , vol.18 , pp. 173-179
    • Quigley, H.A.1    Silver, D.M.2    Friedman, D.S.3
  • 18
    • 0031442088 scopus 로고    scopus 로고
    • Incidence of acute primary angle closure glaucoma in Singapore: An island-wide survey
    • S.K. Seah, P.J. Foster, and P.T. Chew Incidence of acute primary angle closure glaucoma in Singapore: an island-wide survey Arch Ophthalmol 115 1997 1436 1440
    • (1997) Arch Ophthalmol , vol.115 , pp. 1436-1440
    • Seah, S.K.1    Foster, P.J.2    Chew, P.T.3
  • 19
    • 0035380165 scopus 로고    scopus 로고
    • Epidemiology of acute primary angle closure glaucoma in the Hong Kong Chinese population: Prospective study
    • J.S. Lai, D.T. Liu, and C.C. Tham Epidemiology of acute primary angle closure glaucoma in the Hong Kong Chinese population: prospective study Hong Kong Med J 7 2001 118 123
    • (2001) Hong Kong Med J , vol.7 , pp. 118-123
    • Lai, J.S.1    Liu, D.T.2    Tham, C.C.3
  • 20
    • 33644655886 scopus 로고    scopus 로고
    • The number of people with glaucoma worldwide in 2010 and 2020
    • H.A. Quigley, and A.T. Broman The number of people with glaucoma worldwide in 2010 and 2020 Br J Ophthalmol 90 2006 262 267
    • (2006) Br J Ophthalmol , vol.90 , pp. 262-267
    • Quigley, H.A.1    Broman, A.T.2
  • 21
    • 77955883732 scopus 로고    scopus 로고
    • Dynamic analysis of iris configuration with anterior segment optical coherence tomography
    • C.Y. Cheung, S. Liu, and R.N. Weinreb Dynamic analysis of iris configuration with anterior segment optical coherence tomography Invest Ophthalmol Vis Sci 51 2010 4040 4046
    • (2010) Invest Ophthalmol Vis Sci , vol.51 , pp. 4040-4046
    • Cheung, C.Y.1    Liu, S.2    Weinreb, R.N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.