메뉴 건너뛰기




Volumn 39, Issue 12, 2013, Pages 2477-2484

Paraffin-Gel Tissue-Mimicking Material for Ultrasound-Guided Needle Biopsy Phantom

Author keywords

Biopsy training; Breast phantoms; Carnauba wax; Elasticity; Paraffin gel waxes; Tissue mimicking; Ultrasound imaging

Indexed keywords

BIOPSY; ELASTICITY; MATERIALS; PARAFFINS; TISSUE; ULTRASONIC IMAGING; ULTRASONICS; WAXES;

EID: 84887826506     PISSN: 03015629     EISSN: 1879291X     Source Type: Journal    
DOI: 10.1016/j.ultrasmedbio.2013.06.008     Document Type: Article
Times cited : (76)

References (26)
  • 1
    • 0023726379 scopus 로고
    • Tissue-mimicking gelatin agar gels for use in magnetic-resonance imaging phantoms
    • Blechinger J.C., Madsen E.L., Frank G.R. Tissue-mimicking gelatin agar gels for use in magnetic-resonance imaging phantoms. Med Phys 1988, 15:629-636.
    • (1988) Med Phys , vol.15 , pp. 629-636
    • Blechinger, J.C.1    Madsen, E.L.2    Frank, G.R.3
  • 2
    • 0038444298 scopus 로고    scopus 로고
    • Assessment of the acoustic properties of common tissue-mimicking test phantoms
    • Browne J.E., Ramnarine K.V., Watson A.J., Hoskins P.R. Assessment of the acoustic properties of common tissue-mimicking test phantoms. Ultrasound Med Biol 2003, 29:1053-1060.
    • (2003) Ultrasound Med Biol , vol.29 , pp. 1053-1060
    • Browne, J.E.1    Ramnarine, K.V.2    Watson, A.J.3    Hoskins, P.R.4
  • 3
    • 78649907679 scopus 로고    scopus 로고
    • Novel tissue mimicking materials for high frequency breast ultrasound phantoms
    • Cannon L.M., Fagan A.J., Browne J.E. Novel tissue mimicking materials for high frequency breast ultrasound phantoms. Ultrasound Med Biol 2011, 37:122-135.
    • (2011) Ultrasound Med Biol , vol.37 , pp. 122-135
    • Cannon, L.M.1    Fagan, A.J.2    Browne, J.E.3
  • 5
    • 0022800407 scopus 로고
    • Frequency dependence of ultrasound attenuation and backscatter in breast tissue
    • D'Astous F.T., Foster F.S. Frequency dependence of ultrasound attenuation and backscatter in breast tissue. Ultrasound Med Biol 1986, 12:795-808.
    • (1986) Ultrasound Med Biol , vol.12 , pp. 795-808
    • D'Astous, F.T.1    Foster, F.S.2
  • 8
    • 1642458130 scopus 로고    scopus 로고
    • Steady state unfocused circular aperture beam patterns in nonattenuating and attenuating fluids
    • Goldstein A. Steady state unfocused circular aperture beam patterns in nonattenuating and attenuating fluids. JAcoustic Soc Am 2004, 115:99-110.
    • (2004) JAcoustic Soc Am , vol.115 , pp. 99-110
    • Goldstein, A.1
  • 9
    • 0033783374 scopus 로고    scopus 로고
    • Technique and pitfalls of ultrasound-guided core-needle biopsy of the breast
    • Harvey J.A., Moran R.E., DeAngelis G.A. Technique and pitfalls of ultrasound-guided core-needle biopsy of the breast. Semin Ultrasound CT MR 2000, 21:362-364.
    • (2000) Semin Ultrasound CT MR , vol.21 , pp. 362-364
    • Harvey, J.A.1    Moran, R.E.2    DeAngelis, G.A.3
  • 10
    • 0031205261 scopus 로고    scopus 로고
    • Evaluation of a turkey-breast phantom for teaching freehand, US-guided core-needle breast biopsy
    • Harvey J.A., Moran R.E., Hamer M.M., DeAngelis G.A., Omary R.A. Evaluation of a turkey-breast phantom for teaching freehand, US-guided core-needle breast biopsy. Acad Radiol 1997, 4:565-569.
    • (1997) Acad Radiol , vol.4 , pp. 565-569
    • Harvey, J.A.1    Moran, R.E.2    Hamer, M.M.3    DeAngelis, G.A.4    Omary, R.A.5
  • 12
    • 84887828446 scopus 로고    scopus 로고
    • Certificado de ensaio PARABRAX 140/145-1 GEI-código 1001794 Macrocristalina. Bahia, : PETROBRAS Petróleo Brasileiro S.A.,2004.
    • Lacerda MC. Certificado de ensaio PARABRAX 140/145-1 GEI-código 1001794 Macrocristalina. Bahia, : PETROBRAS Petróleo Brasileiro S.A.,2004.
    • Lacerda, M.C.1
  • 13
    • 16544367754 scopus 로고    scopus 로고
    • Development of an ultrasound training phantom of the thyroid gland: Physical characteristics of TMM
    • Ma S.C., Kong Y.K., Ahn Y.M., Park K.J. Development of an ultrasound training phantom of the thyroid gland: Physical characteristics of TMM. Nihon Hoshasen Gijutsu Gakkai Zasshi 2004, 60:1459-1466.
    • (2004) Nihon Hoshasen Gijutsu Gakkai Zasshi , vol.60 , pp. 1459-1466
    • Ma, S.C.1    Kong, Y.K.2    Ahn, Y.M.3    Park, K.J.4
  • 14
    • 0032076844 scopus 로고    scopus 로고
    • Liquid or solid ultrasonically tissue-mimicking materials with very low scatter
    • Madsen E.L., Frank G.R., Dong F. Liquid or solid ultrasonically tissue-mimicking materials with very low scatter. Ultrasound Med Biol 1998, 24:535-542.
    • (1998) Ultrasound Med Biol , vol.24 , pp. 535-542
    • Madsen, E.L.1    Frank, G.R.2    Dong, F.3
  • 16
    • 0020025566 scopus 로고
    • Oil-in-gelatin dispersions for use as ultrasonically tissue-mimicking materials
    • Madsen E.L., Zagzebski J.A., Frank G.R. Oil-in-gelatin dispersions for use as ultrasonically tissue-mimicking materials. Ultrasound Med Biol 1982, 8:277-287.
    • (1982) Ultrasound Med Biol , vol.8 , pp. 277-287
    • Madsen, E.L.1    Zagzebski, J.A.2    Frank, G.R.3
  • 17
    • 0030680104 scopus 로고    scopus 로고
    • Water as a standard in the measurements of speed of sound in liquids
    • Marczak W. Water as a standard in the measurements of speed of sound in liquids. JAcoust Soc Am 1997, 102:2776-2779.
    • (1997) JAcoust Soc Am , vol.102 , pp. 2776-2779
    • Marczak, W.1
  • 19
    • 0035711179 scopus 로고    scopus 로고
    • Tissue-mimicking materials for teaching sonographers and evaluation of their specifications after three years
    • Mokhtari-Dizaji M. Tissue-mimicking materials for teaching sonographers and evaluation of their specifications after three years. Ultrasound Med Biol 2001, 27:1713-1716.
    • (2001) Ultrasound Med Biol , vol.27 , pp. 1713-1716
    • Mokhtari-Dizaji, M.1
  • 20
    • 0028677001 scopus 로고
    • Evaluation of a breast biopsy phantom for learning freehand ultrasound-guided biopsy of the liver
    • Nicotra J.J., Gay S.B., Wallace K.K., McNulty B.C., Dameron R.D. Evaluation of a breast biopsy phantom for learning freehand ultrasound-guided biopsy of the liver. Acad Radiol 1994, 1:385-387.
    • (1994) Acad Radiol , vol.1 , pp. 385-387
    • Nicotra, J.J.1    Gay, S.B.2    Wallace, K.K.3    McNulty, B.C.4    Dameron, R.D.5
  • 21
    • 0002537821 scopus 로고
    • Variation of acoustic speed with temperature in various excised human tissues studied by ultrasound computerized tomography
    • National Bureau of Standards, US Government Printing Office, Washington, DC, M. Linzer (Ed.)
    • Rajagopalan B., Greenleaf J.F., Thomas P.J., Johnson S.A., Bahn R.C. Variation of acoustic speed with temperature in various excised human tissues studied by ultrasound computerized tomography. Ultrasonic tissue characterization II. Spec Publ 525 1979, 227-233. National Bureau of Standards, US Government Printing Office, Washington, DC. M. Linzer (Ed.).
    • (1979) Ultrasonic tissue characterization II. Spec Publ 525 , pp. 227-233
    • Rajagopalan, B.1    Greenleaf, J.F.2    Thomas, P.J.3    Johnson, S.A.4    Bahn, R.C.5
  • 22
    • 34247476453 scopus 로고    scopus 로고
    • Elastic moduli of normal and pathological human breast tissues: An inversion-technique-based investigation of 169 samples
    • Samani A., Zubovits J., Plewes D. Elastic moduli of normal and pathological human breast tissues: An inversion-technique-based investigation of 169 samples. Phys Med Biol 2007, 52:1565-1576.
    • (2007) Phys Med Biol , vol.52 , pp. 1565-1576
    • Samani, A.1    Zubovits, J.2    Plewes, D.3
  • 25
    • 12744271954 scopus 로고    scopus 로고
    • Poly(vinyl alcohol) cryogel phantoms for use in ultrasound and MR imaging
    • Surry K.J.M., Austin H.J.B., Fenster A., Peters T.M. Poly(vinyl alcohol) cryogel phantoms for use in ultrasound and MR imaging. Phys Med Biol 2004, 49:5529-5546.
    • (2004) Phys Med Biol , vol.49 , pp. 5529-5546
    • Surry, K.J.M.1    Austin, H.J.B.2    Fenster, A.3    Peters, T.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.