메뉴 건너뛰기




Volumn 189, Issue 10, 2013, Pages 887-893

Three-dimensional surface scanning for accurate patient positioning and monitoring during breast cancer radiotherapy

Author keywords

Breast conserving surgery; Electronic portal image; Image guided radiotherapy; Intensity modulated radiotherapy; Patient positioning

Indexed keywords

ADULT; AGED; ARTICLE; BODY SURFACE; BREAST CANCER; CAMERA; CANCER PATIENT; CANCER RADIOTHERAPY; CANCER SURGERY; CLINICAL ARTICLE; CLINICAL EVALUATION; COMPUTER ASSISTED RADIOTHERAPY; COMPUTER ASSISTED TOMOGRAPHY; CONSERVATIVE TREATMENT; DIAGNOSTIC IMAGING EQUIPMENT; DIMENSIONAL MEASUREMENT ACCURACY; ELECTRONICS; FEMALE; HUMAN; IMAGE GUIDED RADIOTHERAPY; INTERMETHOD COMPARISON; LASER; MOTION ANALYSIS SYSTEM; OPTICAL THREE DIMENSIONAL SURFACE SCANNER; OPTICAL THREE DIMENSIONAL SURFACE SCANNING; PATIENT MONITORING; PATIENT POSITIONING; SKIN SURFACE; THREE DIMENSIONAL IMAGING; WHOLE BODY IMAGING;

EID: 84887305858     PISSN: 01797158     EISSN: 1439099X     Source Type: Journal    
DOI: 10.1007/s00066-013-0358-6     Document Type: Article
Times cited : (32)

References (29)
  • 1
    • 84873736264 scopus 로고    scopus 로고
    • Target registration errors with surface imaging system in conformal radiotherapy for prostate cancer: Study on 19 patients
    • Bartoncini S, Fiandra C, Ruo Redda MG et al (2012) Target registration errors with surface imaging system in conformal radiotherapy for prostate cancer: study on 19 patients. Radiol Med 117(8):1419-1428
    • (2012) Radiol Med , vol.117 , Issue.8 , pp. 1419-1428
    • Bartoncini, S.1    Fiandra, C.2    Ruo Redda, M.G.3
  • 2
    • 25644432884 scopus 로고    scopus 로고
    • A phantom evaluation of a stereo-vision surface imaging system for radiotherapy setup
    • Bert C, Metheany KG, Doppke K et al (2005) A phantom evaluation of a stereo-vision surface imaging system for radiotherapy setup. Med Phys 2:2753-2762
    • (2005) Med Phys , vol.2 , pp. 2753-2762
    • Bert, C.1    Metheany, K.G.2    Doppke, K.3
  • 3
    • 33644508623 scopus 로고    scopus 로고
    • Clinical experience with a 3D surface patient setup system for alignment of partial-breast irradiation patients
    • Bert C, Metheany KG, Doppke KP et al (2006) Clinical experience with a 3D surface patient setup system for alignment of partial-breast irradiation patients. Int J Radiat Oncol Biol Phys 64:1265-1274
    • (2006) Int J Radiat Oncol Biol Phys , vol.64 , pp. 1265-1274
    • Bert, C.1    Metheany, K.G.2    Doppke, K.P.3
  • 4
    • 0026821209 scopus 로고
    • A method for registration of 3-D shapes
    • Besl P, McKay N (1992) A method for registration of 3-D shapes. IEEE trans. Pat Anal Mach Intel 14(2):239-256
    • (1992) IEEE Trans. Pat Anal Mach Intel , vol.14 , Issue.2 , pp. 239-256
    • Besl, P.1    McKay, N.2
  • 5
    • 42949150067 scopus 로고    scopus 로고
    • 4D laser camera for accurate patient positioning, collision avoidance, image fusion and adaptive approaches during diagnostic and therapeutic procedures
    • Brahme A, Nyman P, Skatt B (2008) 4D laser camera for accurate patient positioning, collision avoidance, image fusion and adaptive approaches during diagnostic and therapeutic procedures. Med Phys 35:1670-1681
    • (2008) Med Phys , vol.35 , pp. 1670-1681
    • Brahme, A.1    Nyman, P.2    Skatt, B.3
  • 7
    • 84866657324 scopus 로고    scopus 로고
    • Patient positioning variations to reduce dose to normal tissues during 3D conformal radiotherapy for high-risk prostate cancer
    • Czigner K, Agoston P, Forgács G et al (2012) Patient positioning variations to reduce dose to normal tissues during 3D conformal radiotherapy for high-risk prostate cancer. Strahlenther Onkol 188(9):816-822
    • (2012) Strahlenther Onkol , vol.188 , Issue.9 , pp. 816-822
    • Czigner, K.1    Agoston, P.2    Forgács, G.3
  • 8
    • 0035283667 scopus 로고    scopus 로고
    • Analysis and reduction of 3D systematic and random setup errors during the simulation and treatment of lung cancer patients with CT-based external beam radiotherapy dose planning
    • Boer HC de, Sörnsen de Koste JR van, Senan S et al (2001) Analysis and reduction of 3D systematic and random setup errors during the simulation and treatment of lung cancer patients with CT-based external beam radiotherapy dose planning. Int J Radiat Oncol Biol Phys 49(3):857-868
    • (2001) Int J Radiat Oncol Biol Phys , vol.49 , Issue.3 , pp. 857-868
    • De Boer, H.C.1    De Van Koste Sörnsen, J.R.2    Senan, S.3
  • 9
    • 38949092101 scopus 로고    scopus 로고
    • "Augmented reality" in conventional simulation by projection of 3-D structures into 2-D images: A comparison with virtual methods
    • Deutschmann H, Steininger P, Nairz O et al (2008) "Augmented reality" in conventional simulation by projection of 3-D structures into 2-D images: a comparison with virtual methods. Strahlenther Onkol 184(2):93-99
    • (2008) Strahlenther Onkol , vol.184 , Issue.2 , pp. 93-99
    • Deutschmann, H.1    Steininger, P.2    Nairz, O.3
  • 10
    • 70350010450 scopus 로고    scopus 로고
    • Measuring interfraction and intrafraction motion with Cone Beam Computed Tomography (CBCT) and an Optical Localization System (OLS) for lower extremity soft tissue sarcoma patients treated with Preoperative Intensity Modulated Radiation Therapy (IMRT)
    • Dickie-Euler C, Parent A, Griffin A et al (2008) Measuring interfraction and intrafraction motion with Cone Beam Computed Tomography (CBCT) and an Optical Localization System (OLS) for lower extremity soft tissue sarcoma patients treated with Preoperative Intensity Modulated Radiation Therapy (IMRT). Int J Radiat Oncol Biol Phys 72:S105-S105
    • (2008) Int J Radiat Oncol Biol Phys , vol.72
    • Dickie-Euler, C.1    Parent, A.2    Griffin, A.3
  • 11
    • 39749161503 scopus 로고    scopus 로고
    • Comparison of target registration errors for multiple image-guided techniques in accelerated partial breast irradiation
    • Gierga DP, Riboldi M, Turcotte JC et al (2008) Comparison of target registration errors for multiple image-guided techniques in accelerated partial breast irradiation. Int J Radiat Oncol Biol Phys 70(4):1239-1246
    • (2008) Int J Radiat Oncol Biol Phys , vol.70 , Issue.4 , pp. 1239-1246
    • Gierga, D.P.1    Riboldi, M.2    Turcotte, J.C.3
  • 12
    • 0001272316 scopus 로고    scopus 로고
    • Three-dimensional vision based on a combination of gray-code and phase-shift light projection: Analysis and compensation of the systematic errors
    • Giovanna S, Carocci M, Rodella R (1999) Three-dimensional vision based on a combination of gray-code and phase-shift light projection: analysis and compensation of the systematic errors. Appl Optics 38(31):6565-6573
    • (1999) Appl Optics , vol.38 , Issue.31 , pp. 6565-6573
    • Giovanna, S.1    Carocci, M.2    Rodella, R.3
  • 13
    • 84862670986 scopus 로고    scopus 로고
    • RapidArc combined with the active breathing coordinator provides an effective and accurate approach for the radiotherapy of hepatocellular carcinoma
    • Gong GZ, Yin Y, Xing LG et al (2012) RapidArc combined with the active breathing coordinator provides an effective and accurate approach for the radiotherapy of hepatocellular carcinoma. Strahlenther Onkol 188(3):262-268
    • (2012) Strahlenther Onkol , vol.188 , Issue.3 , pp. 262-268
    • Gong, G.Z.1    Yin, Y.2    Xing, L.G.3
  • 14
    • 42449092949 scopus 로고    scopus 로고
    • Multisegmented tangential breast fields: A rational way to treat breast cancer
    • Gulybán A, Kovács P, Sebestyén Z et al (2008) Multisegmented tangential breast fields: a rational way to treat breast cancer. Strahlenther Onkol 184(5):262-269
    • (2008) Strahlenther Onkol , vol.184 , Issue.5 , pp. 262-269
    • Gulybán, A.1    Kovács, P.2    Sebestyén, Z.3
  • 15
    • 38349026287 scopus 로고    scopus 로고
    • Image guidance in external beam accelerated partial breast irradiation: Comparison of surrogates for the lumpectomy cavity
    • Hasan Y, Kim L, Martinez A et al (2008) Image guidance in external beam accelerated partial breast irradiation: comparison of surrogates for the lumpectomy cavity. Int J Radiat Oncol Biol Phys 70(2):619-625
    • (2008) Int J Radiat Oncol Biol Phys , vol.70 , Issue.2 , pp. 619-625
    • Hasan, Y.1    Kim, L.2    Martinez, A.3
  • 16
    • 34347392110 scopus 로고    scopus 로고
    • A technique of quantitatively monitoring both respiratory and nonrespiratory motion in patients using external body markers
    • Jin J, Ajlouni M, Ryu S et al (2007) A technique of quantitatively monitoring both respiratory and nonrespiratory motion in patients using external body markers. Med Phys 34:2875-2881
    • (2007) Med Phys , vol.34 , pp. 2875-2881
    • Jin, J.1    Ajlouni, M.2    Ryu, S.3
  • 17
    • 84863503067 scopus 로고    scopus 로고
    • Development of an automated region of interest selection method for 3D surface monitoring of head motion
    • Kang HJ, Grelewicz Z, Wiersma RD (2012) Development of an automated region of interest selection method for 3D surface monitoring of head motion. Med Phys 39(6):3270-3282
    • (2012) Med Phys , vol.39 , Issue.6 , pp. 3270-3282
    • Kang, H.J.1    Grelewicz, Z.2    Wiersma, R.D.3
  • 18
    • 62149123730 scopus 로고    scopus 로고
    • Reproducibility of patient setup by surface image registration system in conformal radiotherapy of prostate cancer
    • Krengli M, Gaiano S, Mones E et al (2009) Reproducibility of patient setup by surface image registration system in conformal radiotherapy of prostate cancer. Radiat Oncol 4:9
    • (2009) Radiat Oncol , vol.4 , pp. 9
    • Krengli, M.1    Gaiano, S.2    Mones, E.3
  • 19
    • 79960293863 scopus 로고    scopus 로고
    • Simple proposal for dosimetry with an Elekta iViewGT™ electronic portal imaging device (EPID) using commercial software modules
    • Liebich J, Licher J, Scherf C et al (2011) Simple proposal for dosimetry with an Elekta iViewGT™ electronic portal imaging device (EPID) using commercial software modules. Strahlenther Onkol 187(5):316-321
    • (2011) Strahlenther Onkol , vol.187 , Issue.5 , pp. 316-321
    • Liebich, J.1    Licher, J.2    Scherf, C.3
  • 20
    • 0345269964 scopus 로고    scopus 로고
    • Opto-electronic sensing of body surface topology changes during radiotherapy for rectal cancer
    • Moore C, Lilley F, Sauret V et al (2003) Opto-electronic sensing of body surface topology changes during radiotherapy for rectal cancer. Int J Radiat Oncol Biol Phys 56(1):248-258
    • (2003) Int J Radiat Oncol Biol Phys , vol.56 , Issue.1 , pp. 248-258
    • Moore, C.1    Lilley, F.2    Sauret, V.3
  • 21
    • 0037408663 scopus 로고    scopus 로고
    • Application of Delaunay triangulation to the nearest neighbour method of strain analysis
    • Mulchrone K (2003) Application of Delaunay triangulation to the nearest neighbour method of strain analysis. J Struct Geol 25:689-702
    • (2003) J Struct Geol , vol.25 , pp. 689-702
    • Mulchrone, K.1
  • 22
    • 58149171936 scopus 로고    scopus 로고
    • A strategy for the use of image-guided radiotherapy (IGRT) on linear accelerators and its impact on treatment margins for prostate cancer patients
    • Nairz O, Merz F, Deutschmann H et al (2008) A strategy for the use of image-guided radiotherapy (IGRT) on linear accelerators and its impact on treatment margins for prostate cancer patients. Strahlenther Onkol 184:663-667
    • (2008) Strahlenther Onkol , vol.184 , pp. 663-667
    • Nairz, O.1    Merz, F.2    Deutschmann, H.3
  • 23
    • 84856972011 scopus 로고    scopus 로고
    • A phantom evaluation of Sentinel(™), a commercial laser/camera surface imaging system for patient setup verification in radiotherapy
    • Pallotta S, Marrazzo L, Ceroti M et al (2012) A phantom evaluation of Sentinel(™), a commercial laser/camera surface imaging system for patient setup verification in radiotherapy. Med Phys 39(2):706-712
    • (2012) Med Phys , vol.39 , Issue.2 , pp. 706-712
    • Pallotta, S.1    Marrazzo, L.2    Ceroti, M.3
  • 24
    • 80052454548 scopus 로고    scopus 로고
    • Geometric and dosimetric approach to determine probability of late cardiac mortality in left tangential breast irradiation: Comparison between wedged beams and field-in-field technique
    • Pili G, Grimaldi L, Fidanza C et al (2011) Geometric and dosimetric approach to determine probability of late cardiac mortality in left tangential breast irradiation: comparison between wedged beams and field-in-field technique. Int J Radiat Oncol Biol Phys 81(3):894-900
    • (2011) Int J Radiat Oncol Biol Phys , vol.81 , Issue.3 , pp. 894-900
    • Pili, G.1    Grimaldi, L.2    Fidanza, C.3
  • 25
    • 0142248791 scopus 로고    scopus 로고
    • Three-dimensional evaluation of intra- and interfraction immobilization of lung and chest wall using active breathing control: A reproducibility study with breast cancer patients
    • Remouchamps VM, Letts N, Yan D et al (2003) Three-dimensional evaluation of intra- and interfraction immobilization of lung and chest wall using active breathing control: a reproducibility study with breast cancer patients. Int J Radiat Oncol Biol Phys 57(4):968-978
    • (2003) Int J Radiat Oncol Biol Phys , vol.57 , Issue.4 , pp. 968-978
    • Remouchamps, V.M.1    Letts, N.2    Yan, D.3
  • 26
    • 84872874385 scopus 로고    scopus 로고
    • Clinical evaluation of a commercial surface-imaging system for patient positioning in radiotherapy
    • Stieler F, Wenz F, Scherrer D et al (2012) Clinical evaluation of a commercial surface-imaging system for patient positioning in radiotherapy. Strahlenther Onkol 188(12):1080-1084
    • (2012) Strahlenther Onkol , vol.188 , Issue.12 , pp. 1080-1084
    • Stieler, F.1    Wenz, F.2    Scherrer, D.3
  • 27
    • 84862657994 scopus 로고    scopus 로고
    • Chest wall radiotherapy with volumetric modulated arcs and the potential role of flattening filter free photon beams
    • Subramaniam S, Thirumalaiswamy S, Srinivas C et al (2012) Chest wall radiotherapy with volumetric modulated arcs and the potential role of flattening filter free photon beams. Strahlenther Onkol 188(6):484-490
    • (2012) Strahlenther Onkol , vol.188 , Issue.6 , pp. 484-490
    • Subramaniam, S.1    Thirumalaiswamy, S.2    Srinivas, C.3
  • 28
    • 0023397578 scopus 로고
    • A versatile camera calibration techniaue for high-accuracy 3D machine vision metrology using off - The-shelf TV cameras and lenses
    • Tsai R (1987) A versatile camera calibration techniaue for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses. IEEE J Robotics Automation 3(4):323-344
    • (1987) IEEE J Robotics Automation , vol.3 , Issue.4 , pp. 323-344
    • Tsai, R.1
  • 29
    • 20044371974 scopus 로고    scopus 로고
    • Automatic generation of a plan optimization volume for tangential field breast cancer radiation therapy
    • Vaerenbergh K et al (2005) Automatic generation of a plan optimization volume for tangential field breast cancer radiation therapy. Strahlenther Onkol 181(2):82-88
    • (2005) Strahlenther Onkol , vol.181 , Issue.2 , pp. 82-88
    • Vaerenbergh, K.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.