메뉴 건너뛰기




Volumn 28, Issue 6, 2013, Pages 536-540

Human albumin in extracorporeal prime: Effect on platelet function and bleeding

Author keywords

blood platelets; cardiopulmonary bypass; coronary artery bypass surgery; serum albumin; thoracic surgery

Indexed keywords

HEMOGLOBIN; HEPARIN; HETASTARCH; HUMAN ALBUMIN; PROTAMINE SULFATE;

EID: 84887237069     PISSN: 02676591     EISSN: 1477111X     Source Type: Journal    
DOI: 10.1177/0267659113492836     Document Type: Article
Times cited : (14)

References (24)
  • 1
    • 33747372490 scopus 로고    scopus 로고
    • Pericardial suction blood separation attenuates inflammatory response and hemolysis after cardiopulmonary bypass
    • Skrabal CA, Khosravi A, Choi YH, et al. Pericardial suction blood separation attenuates inflammatory response and hemolysis after cardiopulmonary bypass. Scand Cardiovasc J. 2006 ; 40: 219-223
    • (2006) Scand Cardiovasc J , vol.40 , pp. 219-223
    • Skrabal, C.A.1    Khosravi, A.2    Choi, Y.H.3
  • 4
    • 0034827963 scopus 로고    scopus 로고
    • Systemic inflammation and cardiac surgery: An update
    • Asimakopoulos G. Systemic inflammation and cardiac surgery: an update. Perfusion. 2001 ; 16: 353-360
    • (2001) Perfusion , vol.16 , pp. 353-360
    • Asimakopoulos, G.1
  • 5
    • 0032857242 scopus 로고    scopus 로고
    • The effects of heparin coating of oxygenator fibers on platelet adhesion and protein adsorption
    • Niimi Y, Ichinose F, Ishiguro Y, et al. The effects of heparin coating of oxygenator fibers on platelet adhesion and protein adsorption. Anesth Analg. 1999 ; 89: 573-579
    • (1999) Anesth Analg , vol.89 , pp. 573-579
    • Niimi, Y.1    Ichinose, F.2    Ishiguro, Y.3
  • 6
    • 0026544564 scopus 로고
    • Anticoagulant effects of sulphonated polyurethanes
    • Silver JH, Hart AP, Williams EC, et al. Anticoagulant effects of sulphonated polyurethanes. Biomaterials. 1992 ; 13: 339-344
    • (1992) Biomaterials , vol.13 , pp. 339-344
    • Silver, J.H.1    Hart, A.P.2    Williams, E.C.3
  • 7
    • 56749161773 scopus 로고    scopus 로고
    • Should the cardiotomy suction blood be cell-saver processed before retransfusion? A clinicopathologic mystery
    • Elahi MM, Matata BM. Should the cardiotomy suction blood be cell-saver processed before retransfusion? A clinicopathologic mystery. Acute Card Care. 2008 ; 10: 227-230
    • (2008) Acute Card Care , vol.10 , pp. 227-230
    • Elahi, M.M.1    Matata, B.M.2
  • 8
    • 0029917305 scopus 로고    scopus 로고
    • Intraoperative autotransfusion reduces blood loss after cardiopulmonary bypass
    • Kochamba GS, Pfeffer TA, Sintek CF, et al. Intraoperative autotransfusion reduces blood loss after cardiopulmonary bypass. Ann Thorac Surg. 1996 ; 61: 900-903
    • (1996) Ann Thorac Surg , vol.61 , pp. 900-903
    • Kochamba, G.S.1    Pfeffer, T.A.2    Sintek, C.F.3
  • 9
    • 0018583611 scopus 로고
    • Blood conservation during myocardial revascularization
    • Cosgrove DM, Thurer RL, Lytle BW, et al. Blood conservation during myocardial revascularization. Ann Thorac Surg. 1979 ; 28: 184-189
    • (1979) Ann Thorac Surg , vol.28 , pp. 184-189
    • Cosgrove, D.M.1    Thurer, R.L.2    Lytle, B.W.3
  • 10
    • 0035095086 scopus 로고    scopus 로고
    • Autotransfusion decreases blood usage following cardiac surgery - A prospective randomized trial
    • Dalrymple-Hay MJR, Dawkins S, Pack L, et al. Autotransfusion decreases blood usage following cardiac surgery - a prospective randomized trial. Cardiovasc Surg. 2001 ; 9: 184-187
    • (2001) Cardiovasc Surg , vol.9 , pp. 184-187
    • Mjr, D.1    Dawkins, S.2    Pack, L.3
  • 11
    • 0024635932 scopus 로고
    • Protein-resistant surfaces prepared by PEO-containing block copolymer surfactants
    • Lee JH, Kopecek J, Andrade JD. Protein-resistant surfaces prepared by PEO-containing block copolymer surfactants. J Biomed Mater Res. 1989 ; 23: 351-368
    • (1989) J Biomed Mater Res , vol.23 , pp. 351-368
    • Lee, J.H.1    Kopecek, J.2    Andrade, J.D.3
  • 12
    • 0032707777 scopus 로고    scopus 로고
    • Trillium coating of cardiopulmonary bypass circuits improves biocompatibility
    • Tevaearai HT, Mueller XM, Seigneul I, et al. Trillium coating of cardiopulmonary bypass circuits improves biocompatibility. Int J Art Organs. 1999 ; 22: 629-634
    • (1999) Int J Art Organs , vol.22 , pp. 629-634
    • Tevaearai, H.T.1    Mueller, X.M.2    Seigneul, I.3
  • 13
    • 0033015386 scopus 로고    scopus 로고
    • Albumin in the cardiopulmonary bypass prime: How little is enough?
    • Palanzo DA, Zarro DL, Montesano RM, et al. Albumin in the cardiopulmonary bypass prime: how little is enough?. Perfusion. 1999 ; 14: 167-172
    • (1999) Perfusion , vol.14 , pp. 167-172
    • Palanzo, D.A.1    Zarro, D.L.2    Montesano, R.M.3
  • 14
    • 0032711644 scopus 로고    scopus 로고
    • Pump-induced platelet aggregation in albumin-coated extracorporeal systems
    • Borgdorff P, van den Berg RH, Vis MA, et al. Pump-induced platelet aggregation in albumin-coated extracorporeal systems. J Thorac Cardiovasc Surg. 1999 ; 118: 946-952
    • (1999) J Thorac Cardiovasc Surg , vol.118 , pp. 946-952
    • Borgdorff, P.1    Van Den Berg, R.H.2    Vis, M.A.3
  • 15
    • 0026447105 scopus 로고
    • Extracorporeal circuits and autoregulation: Effect of albumin coating
    • Borgdorff P, Kok WE, van den Bos GC. Extracorporeal circuits and autoregulation: effect of albumin coating. Am J Physiol. 1992 ; 263: H1397-401
    • (1992) Am J Physiol , vol.263 , pp. 1397-1401
    • Borgdorff, P.1    Kok, W.E.2    Van Den Bos, G.C.3
  • 16
    • 0027878053 scopus 로고
    • Platelet preservation during coronary bypass surgery with bubble and membrane oxygenators: Effect of albumin priming
    • Videm V, Fosse E, Svennevig JL. Platelet preservation during coronary bypass surgery with bubble and membrane oxygenators: effect of albumin priming. Perfusion. 1993 ; 8: 409-415
    • (1993) Perfusion , vol.8 , pp. 409-415
    • Videm, V.1    Fosse, E.2    Svennevig, J.L.3
  • 17
    • 60349107355 scopus 로고    scopus 로고
    • Interaction of plasma proteins with commercial protein repellent polyvinyl chloride (PVC): A word of caution
    • DeSomer F, van Landschoot A, van Nooten G, Delanghe J. Interaction of plasma proteins with commercial protein repellent polyvinyl chloride (PVC): a word of caution. Perfusion. 2008 ; 23: 215-221
    • (2008) Perfusion , vol.23 , pp. 215-221
    • Desomer, F.1    Van Landschoot, A.2    Van Nooten, G.3    Delanghe, J.4
  • 18
    • 0026183355 scopus 로고
    • Prophylactic administration of tranexamic acid preserves platelet numbers during extracorporeal circulation in rabbits
    • Plotz FB, van Oeveren W, Aloe LS, Riley MK, et al. Prophylactic administration of tranexamic acid preserves platelet numbers during extracorporeal circulation in rabbits. ASAIO Trans. 1991 ; 37: M416-417
    • (1991) ASAIO Trans , vol.37 , pp. 416-417
    • Plotz, F.B.1    Van Oeveren, W.2    Aloe, L.S.3    Riley, M.K.4
  • 19
    • 0344553185 scopus 로고
    • Blood reactions during extracorporeal circulation: Panel Discussion, Proc Am Acad Cardiovasc
    • Kurusz M, Vroman L, Voorhees ME, et al. Blood reactions during extracorporeal circulation: Panel Discussion, Proc Am Acad Cardiovasc. Perfusion. 1992 ; 13: 170-175
    • (1992) Perfusion , vol.13 , pp. 170-175
    • Kurusz, M.1    Vroman, L.2    Voorhees, M.E.3
  • 20
    • 0026261754 scopus 로고
    • Synthesis and nonthrombogenicity of polyetherurethaneurea film grafted with Poly(Sodium Vinyl Sulfonate)
    • Ito Y, Iguchi Y, Kashiwagi T, et al. Synthesis and nonthrombogenicity of polyetherurethaneurea film grafted with Poly(Sodium Vinyl Sulfonate). J Biomed Mater Res. 1991 ; 2: 1347-1361
    • (1991) J Biomed Mater Res , vol.2 , pp. 1347-1361
    • Ito, Y.1    Iguchi, Y.2    Kashiwagi, T.3
  • 21
    • 0035080725 scopus 로고    scopus 로고
    • Reversible shear-mediated platelet dysfunction during cardiac surgery as assessed by the PFA-100® platelet function analyzer
    • Slaughter TF, Sreeram G, Sharma AD, et al. Reversible shear-mediated platelet dysfunction during cardiac surgery as assessed by the PFA-100® platelet function analyzer. Blood Coagul Fibrinolysis. 2001 ; 12: 85-93
    • (2001) Blood Coagul Fibrinolysis , vol.12 , pp. 85-93
    • Slaughter, T.F.1    Sreeram, G.2    Sharma, A.D.3
  • 22
    • 25444457540 scopus 로고    scopus 로고
    • Perioperative monitoring of primary and secondary hemostasis in coronary artery bypass grafting
    • Hertfelder H-J, Bos RFB, Weber D, et al. Perioperative monitoring of primary and secondary hemostasis in coronary artery bypass grafting. Sem Thromb Haemost. 2005 ; 31: 426-440
    • (2005) Sem Thromb Haemost , vol.31 , pp. 426-440
    • Hertfelder, H.-J.1    Rfb, B.2    Weber, D.3
  • 23
    • 33645557848 scopus 로고    scopus 로고
    • Platelet function analyzer (PFA)-100 closure time in the evaluation of platelet disorders and platelet function
    • Hayward CPM, Harrison P, Cattaneo M, et al. Platelet function analyzer (PFA)-100 closure time in the evaluation of platelet disorders and platelet function. J Thromb Haemost. 2006 ; 4: 312-319
    • (2006) J Thromb Haemost , vol.4 , pp. 312-319
    • Cpm, H.1    Harrison, P.2    Cattaneo, M.3
  • 24
    • 27744504109 scopus 로고    scopus 로고
    • Heparin influences human platelet behaviour in cardiac surgery with or without cardiopulmonary bypass
    • Laga S, Bollen H, Arnout J, et al. Heparin influences human platelet behaviour in cardiac surgery with or without cardiopulmonary bypass. Artif Organs. 2006 ; 29: 541-546
    • (2006) Artif Organs , vol.29 , pp. 541-546
    • Laga, S.1    Bollen, H.2    Arnout, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.