메뉴 건너뛰기




Volumn 44, Issue 12, 2013, Pages 1926-1929

Clinical experience, primary results and pitfalls in the treatment of intracapsular hip fractures with the Targon® FN locking plate

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; BONE PLATE; BONE SCREW; CLINICAL ARTICLE; EXPERIENCE; FEMALE; FRACTURE REDUCTION; HIP FRACTURE; HUMAN; MALE; PLATE FIXATION; PRIORITY JOURNAL; TREATMENT OUTCOME; EVALUATION STUDY; FOLLOW UP; FRACTURE HEALING; HIP FRACTURES; LENGTH OF STAY; MIDDLE AGED; MORTALITY; OPERATION DURATION; OSTEOSYNTHESIS; POSTOPERATIVE COMPLICATIONS; RADIOGRAPHY; REOPERATION; STATISTICS AND NUMERICAL DATA; VERY ELDERLY;

EID: 84887111008     PISSN: 00201383     EISSN: 18790267     Source Type: Journal    
DOI: 10.1016/j.injury.2013.05.002     Document Type: Article
Times cited : (21)

References (12)
  • 1
    • 0022443610 scopus 로고
    • The Deyerle device for fixation of femoral neck fractures. A review of one hundred twenty-five consecutive cases
    • M.F. Swiontkowski, and S.T. Hansen Jr. The Deyerle device for fixation of femoral neck fractures. A review of one hundred twenty-five consecutive cases Clin Orthop Relat Res 206 1986 248 252
    • (1986) Clin Orthop Relat Res , vol.206 , pp. 248-252
    • Swiontkowski, M.F.1    Hansen, Jr.S.T.2
  • 2
    • 0030052684 scopus 로고    scopus 로고
    • Rigid osteosynthesis decreases the late complication rate after femoral neck fracture. The influence of three different osteosynthesis devices evaluated in 369 patients
    • L. Hernefalk, and K. Messner Rigid osteosynthesis decreases the late complication rate after femoral neck fracture. The influence of three different osteosynthesis devices evaluated in 369 patients Arch Orthop Trauma Surg 115 1996 71 74
    • (1996) Arch Orthop Trauma Surg , vol.115 , pp. 71-74
    • Hernefalk, L.1    Messner, K.2
  • 5
    • 77649272692 scopus 로고    scopus 로고
    • Internal fixation of intracapsular hip fractures with a dynamic locking plate: Initial experience and results for 83 patients treated with a new implant
    • M.J. Parker, and H.W. Stedtfeld Internal fixation of intracapsular hip fractures with a dynamic locking plate: initial experience and results for 83 patients treated with a new implant Injury 41 2010 348 351
    • (2010) Injury , vol.41 , pp. 348-351
    • Parker, M.J.1    Stedtfeld, H.W.2
  • 6
    • 0036268493 scopus 로고    scopus 로고
    • Classification and diagnosis of intracapsular fractures of the proximal femur
    • H.A. Caviglia, P.Q. Osorio, and D. Comando Classification and diagnosis of intracapsular fractures of the proximal femur Clin Orthop Relat Res 399 2002 17 27
    • (2002) Clin Orthop Relat Res , vol.399 , pp. 17-27
    • Caviglia, H.A.1    Osorio, P.Q.2    Comando, D.3
  • 7
    • 80053572643 scopus 로고    scopus 로고
    • The Pauwels classification for intracapsular hip fractures: Is it reliable?
    • D. Embden, G.R. Roukema, S.J. Rhemrev, F. Genelin, and S.A. Meylaerts The Pauwels classification for intracapsular hip fractures: is it reliable? Injury 42 2011 1238 1240
    • (2011) Injury , vol.42 , pp. 1238-1240
    • Embden, D.1    Roukema, G.R.2    Rhemrev, S.J.3    Genelin, F.4    Meylaerts, S.A.5
  • 8
    • 33644863320 scopus 로고    scopus 로고
    • Perception of Garden's classification for femoral neck fractures: An international survey of 298 orthopaedic trauma surgeons
    • M. Zlowodzki, M. Bhandari, M. Keel, B.P. Hanson, and E. Schemitsch Perception of Garden's classification for femoral neck fractures: an international survey of 298 orthopaedic trauma surgeons Arch Orthop Trauma Surg 125 2005 503 505
    • (2005) Arch Orthop Trauma Surg , vol.125 , pp. 503-505
    • Zlowodzki, M.1    Bhandari, M.2    Keel, M.3    Hanson, B.P.4    Schemitsch, E.5
  • 9
    • 18944374772 scopus 로고    scopus 로고
    • The complications of displaced intracapsular fractures of the hip: The effect of screw positioning and angulation on fracture healing
    • K. Gurusamy, M.J. Parker, and T.K. Rowlands The complications of displaced intracapsular fractures of the hip: the effect of screw positioning and angulation on fracture healing J Bone Joint Surg Br 87 2005 632 634
    • (2005) J Bone Joint Surg Br , vol.87 , pp. 632-634
    • Gurusamy, K.1    Parker, M.J.2    Rowlands, T.K.3
  • 10
    • 0347003735 scopus 로고    scopus 로고
    • Optimum configuration of cannulated hip screws for the fixation of intracapsular hip fractures: A biomechanical study
    • V.T. Selvan, M.J. Oakley, A. Rangan, and M.K. Al-Lami Optimum configuration of cannulated hip screws for the fixation of intracapsular hip fractures: a biomechanical study Injury 35 2004 136 141
    • (2004) Injury , vol.35 , pp. 136-141
    • Selvan, V.T.1    Oakley, M.J.2    Rangan, A.3    Al-Lami, M.K.4
  • 11
    • 0029012764 scopus 로고
    • The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip
    • M.R. Baumgaertner, S.L. Curtin, D.M. Lindskog, and J.M. Keggi The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip J Bone Joint Surg Am 77 1995 1058 1064
    • (1995) J Bone Joint Surg Am , vol.77 , pp. 1058-1064
    • Baumgaertner, M.R.1    Curtin, S.L.2    Lindskog, D.M.3    Keggi, J.M.4
  • 12
    • 4444241897 scopus 로고    scopus 로고
    • Prediction of fixation failure after sliding hip screw fixation
    • H. Pervez, M.J. Parker, and S. Vowler Prediction of fixation failure after sliding hip screw fixation Injury 35 2004 994 998
    • (2004) Injury , vol.35 , pp. 994-998
    • Pervez, H.1    Parker, M.J.2    Vowler, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.