메뉴 건너뛰기




Volumn 44, Issue 12, 2013, Pages 1756-1759

Comparison of circumferential pelvic sheeting versus the T-POD on unstable pelvic injuries: A cadaveric study of stability

Author keywords

Binder; Fracture; Immobilization; Pelvic; Sheeting; Stability

Indexed keywords

ARTICLE; CADAVER; COMPARATIVE STUDY; FRACTURE IMMOBILIZATION; HUMAN; MEDICAL DEVICE; MOTION ANALYSIS SYSTEM; PELVIS INJURY; PRIORITY JOURNAL; BIOMECHANICS; COMPRESSIVE STRENGTH; DEVICES; EXTERNAL FIXATOR; FRACTURE FIXATION; FRACTURES, BONE; HEMORRHAGE; IMMOBILIZATION; INJURIES; JOINT INSTABILITY; ORTHOSIS; PELVIC GIRDLE; PROCEDURES; RADIOGRAPHY; THREE DIMENSIONAL IMAGING;

EID: 84887105293     PISSN: 00201383     EISSN: 18790267     Source Type: Journal    
DOI: 10.1016/j.injury.2013.05.016     Document Type: Article
Times cited : (24)

References (41)
  • 2
    • 0024400625 scopus 로고
    • Pelvic fracture in multiple trauma: Classification by mechanism is key to pattern of organ injury, resuscitative requirements, and outcome
    • (discussion 2)
    • S.A. Dalal, A.R. Burgess, and J.H. Siegel Pelvic fracture in multiple trauma: classification by mechanism is key to pattern of organ injury, resuscitative requirements, and outcome J Trauma 29 1989 981 1000 (discussion 2)
    • (1989) J Trauma , vol.29 , pp. 981-1000
    • Dalal, S.A.1    Burgess, A.R.2    Siegel, J.H.3
  • 5
    • 43149123790 scopus 로고    scopus 로고
    • Mortality in patients with pelvic fractures: Results from the German pelvic injury register
    • O. Hauschild, P.C. Strohm, and U. Culemann Mortality in patients with pelvic fractures: results from the German pelvic injury register J Trauma 64 2008 449 455
    • (2008) J Trauma , vol.64 , pp. 449-455
    • Hauschild, O.1    Strohm, P.C.2    Culemann, U.3
  • 7
    • 0035141032 scopus 로고    scopus 로고
    • Pelvic fracture among polytrauma decedents. Trauma-based mortality with pelvic fracture - A case series of 74 patients
    • M. Rittmeister, R.W. Lindsey, and H.W. Kohl 3rd Pelvic fracture among polytrauma decedents. Trauma-based mortality with pelvic fracture - a case series of 74 patients Arch Orthop Trauma Surg 121 2001 43 49
    • (2001) Arch Orthop Trauma Surg , vol.121 , pp. 43-49
    • Rittmeister, M.1    Lindsey, R.W.2    Kohl III, H.W.3
  • 8
    • 0024569367 scopus 로고
    • Mortality after pelvic fractures in the elderly
    • I. Rossvoll, and V. Finsen Mortality after pelvic fractures in the elderly J Orthop Trauma 3 1989 115 117
    • (1989) J Orthop Trauma , vol.3 , pp. 115-117
    • Rossvoll, I.1    Finsen, V.2
  • 10
    • 67649994685 scopus 로고    scopus 로고
    • Emergent management of APC-2 pelvic ring injuries with an anteriorly placed C-clamp
    • M.J. Richard, and P. Tornetta 3rd Emergent management of APC-2 pelvic ring injuries with an anteriorly placed C-clamp J Orthop Trauma 23 2009 322 326
    • (2009) J Orthop Trauma , vol.23 , pp. 322-326
    • Richard, M.J.1    Tornetta III, P.2
  • 12
    • 29544437594 scopus 로고    scopus 로고
    • Emergent stabilization of pelvic ring injuries by controlled circumferential compression: A clinical trial
    • J.C. Krieg, M. Mohr, T.J. Ellis, T.S. Simpson, S.M. Madey, and M. Bottlang Emergent stabilization of pelvic ring injuries by controlled circumferential compression: a clinical trial J Trauma 59 2005 659 664
    • (2005) J Trauma , vol.59 , pp. 659-664
    • Krieg, J.C.1    Mohr, M.2    Ellis, T.J.3    Simpson, T.S.4    Madey, S.M.5    Bottlang, M.6
  • 14
    • 0024605202 scopus 로고
    • The role of external fixation in pelvic disruptions
    • J.F. Kellam The role of external fixation in pelvic disruptions Clin Orthop Relat Res 1989 66 82
    • (1989) Clin Orthop Relat Res , pp. 66-82
    • Kellam, J.F.1
  • 16
    • 2142804164 scopus 로고    scopus 로고
    • Introducing the pelvic sling. Pelvic fracture stabilization made simple
    • M. Bottlang, and J.C. Krieg Introducing the pelvic sling. Pelvic fracture stabilization made simple JEMS 28 2003 84 93
    • (2003) JEMS , vol.28 , pp. 84-93
    • Bottlang, M.1    Krieg, J.C.2
  • 17
    • 79551522668 scopus 로고    scopus 로고
    • Comparison of three different pelvic circumferential compression devices: A biomechanical cadaver study
    • S.P. Knops, N.W. Schep, and C.W. Spoor Comparison of three different pelvic circumferential compression devices: a biomechanical cadaver study J Bone Joint Surg Am 93 2011 230 240
    • (2011) J Bone Joint Surg Am , vol.93 , pp. 230-240
    • Knops, S.P.1    Schep, N.W.2    Spoor, C.W.3
  • 18
    • 68949162043 scopus 로고    scopus 로고
    • Effectiveness and complications of pelvic circumferential compression devices in patients with unstable pelvic fractures: A systematic review of literature
    • W.R. Spanjersberg, S.P. Knops, N.W. Schep, E.M. van Lieshout, P. Patka, and I.B. Schipper Effectiveness and complications of pelvic circumferential compression devices in patients with unstable pelvic fractures: a systematic review of literature Injury 40 2009 1031 1035
    • (2009) Injury , vol.40 , pp. 1031-1035
    • Spanjersberg, W.R.1    Knops, S.P.2    Schep, N.W.3    Van Lieshout, E.M.4    Patka, P.5    Schipper, I.B.6
  • 19
    • 78149317419 scopus 로고    scopus 로고
    • Effect of a new pelvic stabilizer (T-POD(R)) on reduction of pelvic volume and haemodynamic stability in unstable pelvic fractures
    • E.C. Tan, S.F. van Stigt, and A.B. van Vugt Effect of a new pelvic stabilizer (T-POD(R)) on reduction of pelvic volume and haemodynamic stability in unstable pelvic fractures Injury 41 2010 1239 1243
    • (2010) Injury , vol.41 , pp. 1239-1243
    • Tan, E.C.1    Van Stigt, S.F.2    Van Vugt, A.B.3
  • 20
    • 0036064023 scopus 로고    scopus 로고
    • Noninvasive reduction of open-book pelvic fractures by circumferential compression
    • M. Bottlang, T. Simpson, J. Sigg, J.C. Krieg, S.M. Madey, and W.B. Long Noninvasive reduction of open-book pelvic fractures by circumferential compression J Orthop Trauma 16 2002 367 373
    • (2002) J Orthop Trauma , vol.16 , pp. 367-373
    • Bottlang, M.1    Simpson, T.2    Sigg, J.3    Krieg, J.C.4    Madey, S.M.5    Long, W.B.6
  • 21
    • 68749117650 scopus 로고    scopus 로고
    • Management of hemorrhage in life-threatening pelvic fracture
    • D.J. Hak, W.R. Smith, and T. Suzuki Management of hemorrhage in life-threatening pelvic fracture J Am Acad Orthop Surg 17 2009 447 457
    • (2009) J Am Acad Orthop Surg , vol.17 , pp. 447-457
    • Hak, D.J.1    Smith, W.R.2    Suzuki, T.3
  • 22
    • 47349105540 scopus 로고    scopus 로고
    • Use of the trauma pelvic orthotic device (T-POD) for provisional stabilisation of anterior-posterior compression type pelvic fractures: A cadaveric study
    • N.A. DeAngelis, J.J. Wixted, J. Drew, M.S. Eskander, J.P. Eskander, and B.G. French Use of the trauma pelvic orthotic device (T-POD) for provisional stabilisation of anterior-posterior compression type pelvic fractures: a cadaveric study Injury 39 2008 903 906
    • (2008) Injury , vol.39 , pp. 903-906
    • Deangelis, N.A.1    Wixted, J.J.2    Drew, J.3    Eskander, M.S.4    Eskander, J.P.5    French, B.G.6
  • 23
    • 33750001206 scopus 로고    scopus 로고
    • Three-dimensional analysis of pelvic volume in an unstable pelvic fracture
    • M.D. Stover, H.D. Summers, A.J. Ghanayem, and J.H. Wilber Three-dimensional analysis of pelvic volume in an unstable pelvic fracture J Trauma 61 2006 905 908
    • (2006) J Trauma , vol.61 , pp. 905-908
    • Stover, M.D.1    Summers, H.D.2    Ghanayem, A.J.3    Wilber, J.H.4
  • 24
    • 0025332809 scopus 로고
    • Pelvic ring disruptions: Effective classification system and treatment protocols
    • A.R. Burgess, B.J. Eastridge, and J.W. Young Pelvic ring disruptions: effective classification system and treatment protocols J Trauma 30 1990 848 856
    • (1990) J Trauma , vol.30 , pp. 848-856
    • Burgess, A.R.1    Eastridge, B.J.2    Young, J.W.3
  • 25
    • 70349733531 scopus 로고    scopus 로고
    • Percutaneous pelvic fixation using working portals in a circumferential pelvic antishock sheet
    • M.J. Gardner, G. Osgood, R. Molnar, and M.L. Chip Routt Jr. Percutaneous pelvic fixation using working portals in a circumferential pelvic antishock sheet J Orthop Trauma 23 2009 668 674
    • (2009) J Orthop Trauma , vol.23 , pp. 668-674
    • Gardner, M.J.1    Osgood, G.2    Molnar, R.3    Chip Routt, Jr.M.L.4
  • 26
    • 0036396572 scopus 로고    scopus 로고
    • Emergent management of pelvic ring fractures with use of circumferential compression
    • SUPPL. 2
    • M. Bottlang, J.C. Krieg, M. Mohr, T.S. Simpson, and S.M. Madey Emergent management of pelvic ring fractures with use of circumferential compression J Bone Joint Surg Am 84-A Suppl. 2 2002 43 47
    • (2002) J Bone Joint Surg Am , vol.84 A , pp. 43-47
    • Bottlang, M.1    Krieg, J.C.2    Mohr, M.3    Simpson, T.S.4    Madey, S.M.5
  • 27
    • 0036153706 scopus 로고    scopus 로고
    • Stabilization of pelvic ring disruptions with a circumferential sheet
    • T. Simpson, J.C. Krieg, F. Heuer, and M. Bottlang Stabilization of pelvic ring disruptions with a circumferential sheet J Trauma 52 2002 158 161
    • (2002) J Trauma , vol.52 , pp. 158-161
    • Simpson, T.1    Krieg, J.C.2    Heuer, F.3    Bottlang, M.4
  • 28
  • 29
    • 2942623960 scopus 로고    scopus 로고
    • Damage control orthopaedics in unstable pelvic ring injuries
    • P.V. Giannoudis, and H.C. Pape Damage control orthopaedics in unstable pelvic ring injuries Injury 35 2004 671 677
    • (2004) Injury , vol.35 , pp. 671-677
    • Giannoudis, P.V.1    Pape, H.C.2
  • 30
    • 27744577350 scopus 로고    scopus 로고
    • Skin breakdown following circumferential pelvic antishock sheeting: A case report
    • T.M. Schaller, S. Sims, and T. Maxian Skin breakdown following circumferential pelvic antishock sheeting: a case report J Orthop Trauma 19 2005 661 665
    • (2005) J Orthop Trauma , vol.19 , pp. 661-665
    • Schaller, T.M.1    Sims, S.2    Maxian, T.3
  • 31
    • 34249992539 scopus 로고    scopus 로고
    • Log-rolling technique producing unacceptable motion during body position changes in patients with traumatic spinal cord injury
    • B.P. Conrad, M. Horodyski, J. Wright, P. Ruetz, and G.R. Rechtine 2nd Log-rolling technique producing unacceptable motion during body position changes in patients with traumatic spinal cord injury J Neurosurg Spine 6 2007 540 543
    • (2007) J Neurosurg Spine , vol.6 , pp. 540-543
    • Conrad, B.P.1    Horodyski, M.2    Wright, J.3    Ruetz, P.4    Rechtine II, G.R.5
  • 32
    • 77955905934 scopus 로고    scopus 로고
    • Motion in the unstable cervical spine during hospital bed transfers
    • B.P. Conrad, G. Rechtine, M. Weight, J. Clarke, and M. Horodyski Motion in the unstable cervical spine during hospital bed transfers J Trauma 69 2010 432 436
    • (2010) J Trauma , vol.69 , pp. 432-436
    • Conrad, B.P.1    Rechtine, G.2    Weight, M.3    Clarke, J.4    Horodyski, M.5
  • 33
    • 8644278107 scopus 로고    scopus 로고
    • The effectiveness of extrication collars tested during the execution of spine-board transfer techniques
    • G. Del Rossi, T.P. Heffernan, M. Horodyski, and G.R. Rechtine The effectiveness of extrication collars tested during the execution of spine-board transfer techniques Spine J 4 2004 619 623
    • (2004) Spine J , vol.4 , pp. 619-623
    • Del Rossi, G.1    Heffernan, T.P.2    Horodyski, M.3    Rechtine, G.R.4
  • 34
  • 36
    • 74249120387 scopus 로고    scopus 로고
    • Cervical spine motion generated with manual versus jackson table turning methods in a cadaveric c1-c2 global instability model
    • C.P. Dipaola, B.P. Conrad, M. Horodyski, M.J. Dipaola, A. Sawers, and G.R. Rechtine 2nd Cervical spine motion generated with manual versus jackson table turning methods in a cadaveric c1-c2 global instability model Spine (Phila, Pa 1976) 34 2009 2912 2918
    • (2009) Spine (Phila, Pa 1976) , vol.34 , pp. 2912-2918
    • Dipaola, C.P.1    Conrad, B.P.2    Horodyski, M.3    Dipaola, M.J.4    Sawers, A.5    Rechtine II, G.R.6
  • 37
    • 48749112469 scopus 로고    scopus 로고
    • Comparison of thoracolumbar motion produced by manual and Jackson-table-turning methods. Study of a cadaveric instability model
    • C.P. DiPaola, M.J. DiPaola, and B.P. Conrad Comparison of thoracolumbar motion produced by manual and Jackson-table-turning methods. Study of a cadaveric instability model J Bone Joint Surg Am 90 2008 1698 1704
    • (2008) J Bone Joint Surg Am , vol.90 , pp. 1698-1704
    • Dipaola, C.P.1    Dipaola, M.J.2    Conrad, B.P.3
  • 38
    • 48949097074 scopus 로고    scopus 로고
    • Cervical spine motion in manual versus Jackson table turning methods in a cadaveric global instability model
    • M.J. DiPaola, C.P. DiPaola, and B.P. Conrad Cervical spine motion in manual versus Jackson table turning methods in a cadaveric global instability model J Spinal Disord Tech 21 2008 273 280
    • (2008) J Spinal Disord Tech , vol.21 , pp. 273-280
    • Dipaola, M.J.1    Dipaola, C.P.2    Conrad, B.P.3
  • 39
    • 67649402415 scopus 로고    scopus 로고
    • Comparison of the flat torso versus the elevated torso shoulder pad removal techniques in a cadaveric cervical spine instability model
    • M. Horodyski, C.P. DiPaola, M.J. DiPaola, B.P. Conrad, G. Del Rossi, and G.R. Rechtine 2nd Comparison of the flat torso versus the elevated torso shoulder pad removal techniques in a cadaveric cervical spine instability model Spine (Phila, Pa 1976) 34 2009 687 691
    • (2009) Spine (Phila, Pa 1976) , vol.34 , pp. 687-691
    • Horodyski, M.1    Dipaola, C.P.2    Dipaola, M.J.3    Conrad, B.P.4    Del Rossi, G.5    Rechtine II, G.R.6
  • 40
    • 33847005072 scopus 로고    scopus 로고
    • Biomechanical analysis of cervical and thoracolumbar spine motion in intact and partially and completely unstable cadaver spine models with kinetic bed therapy or traditional log roll
    • discussion 8
    • G.R. Rechtine, B.P. Conrad, B.G. Bearden, and M. Horodyski Biomechanical analysis of cervical and thoracolumbar spine motion in intact and partially and completely unstable cadaver spine models with kinetic bed therapy or traditional log roll J Trauma 62 2007 383 388 discussion 8
    • (2007) J Trauma , vol.62 , pp. 383-388
    • Rechtine, G.R.1    Conrad, B.P.2    Bearden, B.G.3    Horodyski, M.4
  • 41
    • 4744341795 scopus 로고    scopus 로고
    • Motion generated in the unstable spine during hospital bed transfers
    • (discussion 11-12)
    • G.R. Rechtine, G. Del Rossi, B.P. Conrad, and M. Horodyski Motion generated in the unstable spine during hospital bed transfers J Trauma 57 2004 609 611 (discussion 11-12)
    • (2004) J Trauma , vol.57 , pp. 609-611
    • Rechtine, G.R.1    Del Rossi, G.2    Conrad, B.P.3    Horodyski, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.