메뉴 건너뛰기




Volumn 70, Issue 5, 2013, Pages 1283-1292

Voxel spread function method for correction of magnetic field inhomogeneity effects in quantitative gradient-echo-based MRI

Author keywords

gradient echo; magnetic field inhomogeneities; magnetic susceptibility; MRI

Indexed keywords

CLINICAL RESEARCH; MAGNETIC RESONANCE IMAGING; MAGNETIC SUSCEPTIBILITY; PHANTOMS; RATE CONSTANTS; SIGNAL SYSTEMS; TISSUE;

EID: 84886802742     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.24585     Document Type: Article
Times cited : (105)

References (36)
  • 1
    • 0028142827 scopus 로고
    • Assessment of relative brain iron concentrations using T2-weighted and T2*-weighted MRI at 3 Tesla
    • Ordidge RJ, Gorell JM, Deniau JC, Knight RA, Helpern JA,. Assessment of relative brain iron concentrations using T2-weighted and T2*-weighted MRI at 3 Tesla. Magn Reson Med 1994; 32: 335-341.
    • (1994) Magn Reson Med , vol.32 , pp. 335-341
    • Ordidge, R.J.1    Gorell, J.M.2    Deniau, J.C.3    Knight, R.A.4    Helpern, J.A.5
  • 2
    • 0023937754 scopus 로고
    • Direct FLASH MR imaging of magnetic field inhomogeneities by gradient compensation
    • Frahm J, Merboldt KD, Hanicke W,. Direct FLASH MR imaging of magnetic field inhomogeneities by gradient compensation. Magn Reson Med 1988; 6: 474-480.
    • (1988) Magn Reson Med , vol.6 , pp. 474-480
    • Frahm, J.1    Merboldt, K.D.2    Hanicke, W.3
  • 3
    • 0024476775 scopus 로고
    • Reduction of T2* dephasing in gradient field-echo imaging
    • Haacke EM, Tkach JA, Parrish TB,. Reduction of T2* dephasing in gradient field-echo imaging. Radiology 1989; 170: 457-462.
    • (1989) Radiology , vol.170 , pp. 457-462
    • Haacke, E.M.1    Tkach, J.A.2    Parrish, T.B.3
  • 4
    • 0026500406 scopus 로고
    • Reduction of susceptibility artifact in gradient-echo imaging
    • Cho ZH, Ro YM,. Reduction of susceptibility artifact in gradient-echo imaging. Magn Reson Med 1992; 23: 193-200.
    • (1992) Magn Reson Med , vol.23 , pp. 193-200
    • Cho, Z.H.1    Ro, Y.M.2
  • 5
    • 0031931936 scopus 로고    scopus 로고
    • Removal of local field gradient artifacts in T2*-weighted images at high fields by gradient-echo slice excitation profile imaging
    • Yang QX, Williams GD, Demeure RJ, Mosher TJ, Smith MB,. Removal of local field gradient artifacts in T2*-weighted images at high fields by gradient-echo slice excitation profile imaging. Magn Reson Med 1998; 39: 402-409.
    • (1998) Magn Reson Med , vol.39 , pp. 402-409
    • Yang, Q.X.1    Williams, G.D.2    Demeure, R.J.3    Mosher, T.J.4    Smith, M.B.5
  • 6
    • 0036845524 scopus 로고    scopus 로고
    • Multiple gradient echo sequence optimized for rapid, single-scan mapping of R(2)(*) at high B0
    • Wild JM, Martin WR, Allen PS,. Multiple gradient echo sequence optimized for rapid, single-scan mapping of R(2)(*) at high B0. Magn Reson Med 2002; 48: 867-876.
    • (2002) Magn Reson Med , vol.48 , pp. 867-876
    • Wild, J.M.1    Martin, W.R.2    Allen, P.S.3
  • 7
    • 10044235365 scopus 로고    scopus 로고
    • Reduction of magnetic field inhomogeneity artifacts in echo planar imaging with SENSE and GESEPI at high field
    • Yang QX, Wang J, Smith MB, Meadowcroft M, Sun X, Eslinger PJ, Golay X,. Reduction of magnetic field inhomogeneity artifacts in echo planar imaging with SENSE and GESEPI at high field. Magn Reson Med 2004; 52: 1418-1423.
    • (2004) Magn Reson Med , vol.52 , pp. 1418-1423
    • Yang, Q.X.1    Wang, J.2    Smith, M.B.3    Meadowcroft, M.4    Sun, X.5    Eslinger, P.J.6    Golay, X.7
  • 8
    • 33745713992 scopus 로고    scopus 로고
    • Natural linewidth chemical shift imaging (NL-CSI)
    • Bashir A, Yablonskiy DA,. Natural linewidth chemical shift imaging (NL-CSI). Magn Reson Med 2006; 56: 7-18.
    • (2006) Magn Reson Med , vol.56 , pp. 7-18
    • Bashir, A.1    Yablonskiy, D.A.2
  • 9
    • 33744949650 scopus 로고    scopus 로고
    • Blipped multi gradient-echo slice excitation profile imaging (bmGESEPI) for fast T2* measurements with macroscopic B0 inhomogeneity compensation
    • Truong TK, Chakeres DW, Scharre DW, Beversdorf DQ, Schmalbrock P,. Blipped multi gradient-echo slice excitation profile imaging (bmGESEPI) for fast T2* measurements with macroscopic B0 inhomogeneity compensation. Magn Reson Med 2006; 55: 1390-1395.
    • (2006) Magn Reson Med , vol.55 , pp. 1390-1395
    • Truong, T.K.1    Chakeres, D.W.2    Scharre, D.W.3    Beversdorf, D.Q.4    Schmalbrock, P.5
  • 10
    • 62049086032 scopus 로고    scopus 로고
    • Reduction of susceptibility-induced signal losses in multi-gradient-echo images: Application to improved visualization of the subthalamic nucleus
    • Volz S, Hattingen E, Preibisch C, Gasser T, Deichmann R,. Reduction of susceptibility-induced signal losses in multi-gradient-echo images: application to improved visualization of the subthalamic nucleus. Neuroimage 2009; 45: 1135-1143.
    • (2009) Neuroimage , vol.45 , pp. 1135-1143
    • Volz, S.1    Hattingen, E.2    Preibisch, C.3    Gasser, T.4    Deichmann, R.5
  • 11
    • 0031907230 scopus 로고    scopus 로고
    • Quantitation of intrinsic magnetic susceptibility-related effects in a tissue matrix. Phantom study
    • Yablonskiy DA,. Quantitation of intrinsic magnetic susceptibility-related effects in a tissue matrix. Phantom study. Magn Reson Med 1998; 39: 417-428.
    • (1998) Magn Reson Med , vol.39 , pp. 417-428
    • Yablonskiy, D.A.1
  • 12
    • 0033816884 scopus 로고    scopus 로고
    • Postprocessing technique to correct for background gradients in image-based R*(2) measurements
    • Fernandez-Seara MA, Wehrli FW,. Postprocessing technique to correct for background gradients in image-based R*(2) measurements. Magn Reson Med 2000; 44: 358-366.
    • (2000) Magn Reson Med , vol.44 , pp. 358-366
    • Fernandez-Seara, M.A.1    Wehrli, F.W.2
  • 13
    • 0036240237 scopus 로고    scopus 로고
    • Cerebral oxygen extraction fraction and cerebral venous blood volume measurements using MRI: Effects of magnetic field variation
    • An H, Lin W,. Cerebral oxygen extraction fraction and cerebral venous blood volume measurements using MRI: effects of magnetic field variation. Magn Reson Med 2002; 47: 958-966.
    • (2002) Magn Reson Med , vol.47 , pp. 958-966
    • An, H.1    Lin, W.2
  • 14
    • 18244403164 scopus 로고    scopus 로고
    • Limits of detection of SPIO at 3.0 T using T2 relaxometry
    • Dahnke H, Schaeffter T,. Limits of detection of SPIO at 3.0 T using T2 relaxometry. Magn Reson Med 2005; 53: 1202-1206.
    • (2005) Magn Reson Med , vol.53 , pp. 1202-1206
    • Dahnke, H.1    Schaeffter, T.2
  • 15
    • 67650097317 scopus 로고    scopus 로고
    • Rapid single-scan T2*-mapping using exponential excitation pulses and image-based correction for linear background gradients
    • Baudrexel S, Volz S, Preibisch C, Klein JC, Steinmetz H, Hilker R, Deichmann R,. Rapid single-scan T2*-mapping using exponential excitation pulses and image-based correction for linear background gradients. Magn Reson Med 2009; 62: 263-268.
    • (2009) Magn Reson Med , vol.62 , pp. 263-268
    • Baudrexel, S.1    Volz, S.2    Preibisch, C.3    Klein, J.C.4    Steinmetz, H.5    Hilker, R.6    Deichmann, R.7
  • 16
    • 77955285465 scopus 로고    scopus 로고
    • Postprocessing correction for distortions in T2* decay caused by quadratic cross-slice B0 inhomogeneity
    • Yang X, Sammet S, Schmalbrock P, Knopp MV,. Postprocessing correction for distortions in T2* decay caused by quadratic cross-slice B0 inhomogeneity. Magn Reson Med 2010; 63: 1258-1268.
    • (2010) Magn Reson Med , vol.63 , pp. 1258-1268
    • Yang, X.1    Sammet, S.2    Schmalbrock, P.3    Knopp, M.V.4
  • 17
    • 84865500545 scopus 로고    scopus 로고
    • R2* mapping in the presence of macroscopic B0 field variations
    • Hernando D, Vigen KK, Shimakawa A, Reeder SB,. R2* mapping in the presence of macroscopic B0 field variations. Magn Reson Med 2012; 68: 830-840.
    • (2012) Magn Reson Med , vol.68 , pp. 830-840
    • Hernando, D.1    Vigen, K.K.2    Shimakawa, A.3    Reeder, S.B.4
  • 18
    • 84856147075 scopus 로고    scopus 로고
    • On the performance of T2* correction methods for quantification of hepatic fat content
    • Reeder SB, Bice EK, Yu H, Hernando D, Pineda AR,. On the performance of T2* correction methods for quantification of hepatic fat content. Magn Reson Med 2012; 67: 389-404.
    • (2012) Magn Reson Med , vol.67 , pp. 389-404
    • Reeder, S.B.1    Bice, E.K.2    Yu, H.3    Hernando, D.4    Pineda, A.R.5
  • 19
    • 0028830695 scopus 로고
    • The voxel sensitivity function in Fourier transform imaging: Applications to magnetic resonance angiography
    • Parker DL, Du YP, Davis WL,. The voxel sensitivity function in Fourier transform imaging: applications to magnetic resonance angiography. Magn Reson Med 1995; 33: 156-162.
    • (1995) Magn Reson Med , vol.33 , pp. 156-162
    • Parker, D.L.1    Du, Y.P.2    Davis, W.L.3
  • 20
    • 84878112965 scopus 로고    scopus 로고
    • Accelerated point spread function mapping using signal modeling for accurate echo-planar imaging geometric distortion correction
    • Dragonu I, Lange T, Baxan N, Snyder J, Hennig J, Zaitsev M,. Accelerated point spread function mapping using signal modeling for accurate echo-planar imaging geometric distortion correction. Magn Reson Med 2013; 69: 1650-1656.
    • (2013) Magn Reson Med , vol.69 , pp. 1650-1656
    • Dragonu, I.1    Lange, T.2    Baxan, N.3    Snyder, J.4    Hennig, J.5    Zaitsev, M.6
  • 21
    • 0030118720 scopus 로고    scopus 로고
    • Method for image-based measurement of the reversible and irreversible contribution to the transverse-relaxation rate
    • Ma J, Wehrli FW,. Method for image-based measurement of the reversible and irreversible contribution to the transverse-relaxation rate. J Magn Reson B 1996; 111: 61-69.
    • (1996) J Magn Reson B , vol.111 , pp. 61-69
    • Ma, J.1    Wehrli, F.W.2
  • 24
    • 0023690094 scopus 로고
    • Calculation of MRI artifacts caused by static field disturbances
    • Ericsson A, Hemmingsson A, Jung B, Sperber GO,. Calculation of MRI artifacts caused by static field disturbances. Phys Med Biol 1988; 33: 1103-1112.
    • (1988) Phys Med Biol , vol.33 , pp. 1103-1112
    • Ericsson, A.1    Hemmingsson, A.2    Jung, B.3    Sperber, G.O.4
  • 25
    • 0000535886 scopus 로고
    • Susceptibility Artifacts in Spin-Echo and Gradient-Echo Imaging
    • Posse S, Aue WP,. Susceptibility Artifacts in Spin-Echo and Gradient-Echo Imaging. J Magn Reson 1990; 88: 473-492.
    • (1990) J Magn Reson , vol.88 , pp. 473-492
    • Posse, S.1    Aue, W.P.2
  • 26
    • 0026688913 scopus 로고
    • Analysis of machine-dependent and object-induced geometric distortion in 2DFT MR imaging
    • Bakker CJ, Moerland MA, Bhagwandien R, Beersma R,. Analysis of machine-dependent and object-induced geometric distortion in 2DFT MR imaging. Magn Reson Imaging 1992; 10: 597-608.
    • (1992) Magn Reson Imaging , vol.10 , pp. 597-608
    • Bakker, C.J.1    Moerland, M.A.2    Bhagwandien, R.3    Beersma, R.4
  • 27
    • 63349084535 scopus 로고    scopus 로고
    • Optimal decay rate constant estimates from phased array data utilizing joint Bayesian analysis
    • Quirk JD, Sukstanskii AL, Bretthorst GL, Yablonskiy DA,. Optimal decay rate constant estimates from phased array data utilizing joint Bayesian analysis. J Magn Reson 2009; 198: 49-56.
    • (2009) J Magn Reson , vol.198 , pp. 49-56
    • Quirk, J.D.1    Sukstanskii, A.L.2    Bretthorst, G.L.3    Yablonskiy, D.A.4
  • 28
    • 84856998747 scopus 로고    scopus 로고
    • Gradient echo plural contrast imaging - Signal model and derived contrasts: T2*, T1, Phase, SWI, T1f, FST2*and T2*-SWI
    • Luo J, Jagadeesan BD, Cross AH, Yablonskiy DA,. Gradient echo plural contrast imaging-signal model and derived contrasts: T2*, T1, Phase, SWI, T1f, FST2*and T2*-SWI. Neuroimage 2012; 60: 1073-1082.
    • (2012) Neuroimage , vol.60 , pp. 1073-1082
    • Luo, J.1    Jagadeesan, B.D.2    Cross, A.H.3    Yablonskiy, D.A.4
  • 29
    • 77952429114 scopus 로고    scopus 로고
    • In vivo quantitative evaluation of brain tissue damage in multiple sclerosis using gradient echo plural contrast imaging technique
    • Sati P, Cross AH, Luo J, Hildebolt CF, Yablonskiy DA,. In vivo quantitative evaluation of brain tissue damage in multiple sclerosis using gradient echo plural contrast imaging technique. Neuroimage 2010; 51: 1089-1097.
    • (2010) Neuroimage , vol.51 , pp. 1089-1097
    • Sati, P.1    Cross, A.H.2    Luo, J.3    Hildebolt, C.F.4    Yablonskiy, D.A.5
  • 31
    • 0027973923 scopus 로고
    • Theory of NMR signal behavior in magnetically inhomogeneous tissues: The static dephasing regime
    • Yablonskiy DA, Haacke EM,. Theory of NMR signal behavior in magnetically inhomogeneous tissues: the static dephasing regime. Magn Reson Med 1994; 32: 749-763.
    • (1994) Magn Reson Med , vol.32 , pp. 749-763
    • Yablonskiy, D.A.1    Haacke, E.M.2
  • 32
    • 0025630001 scopus 로고
    • Brain magnetic resonance imaging with contrast dependent on blood oxygenation
    • Ogawa S, Lee T, Kay A, Tank D,. Brain magnetic resonance imaging with contrast dependent on blood oxygenation. Proc Natl Acad Sci USA 1990; 87: 868-9872.
    • (1990) Proc Natl Acad Sci USA , vol.87 , pp. 868-9872
    • Ogawa, S.1    Lee, T.2    Kay, A.3    Tank, D.4
  • 33
    • 0025336246 scopus 로고
    • Oxygenation-sensitive contrast in magnetic resonance image of rodent brain at high fields
    • Ogawa S, Lee T, Nayak AS, Glynn P,. Oxygenation-sensitive contrast in magnetic resonance image of rodent brain at high fields. Magn Reson Med 1990; 14: 68-78.
    • (1990) Magn Reson Med , vol.14 , pp. 68-78
    • Ogawa, S.1    Lee, T.2    Nayak, A.S.3    Glynn, P.4
  • 34
    • 84880939892 scopus 로고    scopus 로고
    • Blood oxygenation leveldependent (BOLD)-based techniques for the quantification of brain hemodynamic and metabolic properties - Theoretical models and experimental approaches
    • Yablonskiy DA, Sukstanskii AL, He X,. Blood oxygenation leveldependent (BOLD)-based techniques for the quantification of brain hemodynamic and metabolic properties-theoretical models and experimental approaches. NMR Biomed 2013; 26: 963-986.
    • (2013) NMR Biomed , vol.26 , pp. 963-986
    • Yablonskiy, D.A.1    Sukstanskii, A.L.2    He, X.3
  • 35
    • 33846085587 scopus 로고    scopus 로고
    • Quantitative BOLD: Mapping of human cerebral deoxygenated blood volume and oxygen extraction fraction: Default state
    • He X, Yablonskiy DA,. Quantitative BOLD: mapping of human cerebral deoxygenated blood volume and oxygen extraction fraction: default state. Magn Reson Med 2007; 57: 115-126.
    • (2007) Magn Reson Med , vol.57 , pp. 115-126
    • He, X.1    Yablonskiy, D.A.2
  • 36
    • 53549089633 scopus 로고    scopus 로고
    • Validation of oxygen extraction fraction measurement by qBOLD technique
    • He X, Zhu M, Yablonskiy DA,. Validation of oxygen extraction fraction measurement by qBOLD technique. Magn Reson Med 2008; 60: 882-888.
    • (2008) Magn Reson Med , vol.60 , pp. 882-888
    • He, X.1    Zhu, M.2    Yablonskiy, D.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.