메뉴 건너뛰기




Volumn 18, Issue 5, 2013, Pages

Infrared laser thermal fusion of blood vessels: Preliminary ex vivo tissue studies

Author keywords

blood vessels; coagulation; fusion; hemostasis; infrared; laser; sealing

Indexed keywords

ANIMAL; ARTICLE; BIOLOGICAL MODEL; EQUIPMENT; HISTOLOGY; INFRARED RADIATION; KIDNEY; KIDNEY VEIN; LASER; LASER COAGULATION; METHODOLOGY; PATHOLOGY; RADIATION EXPOSURE; SWINE; VASCULARIZATION;

EID: 84886800459     PISSN: 10833668     EISSN: 15602281     Source Type: Journal    
DOI: 10.1117/1.JBO.18.5.058001     Document Type: Article
Times cited : (32)

References (28)
  • 1
    • 77950996188 scopus 로고    scopus 로고
    • Comparison of 5 surgical techniques for partial liver lobectomy in the dog for intraoperative blood loss and surgical time
    • M. Risselada et al., "Comparison of 5 surgical techniques for partial liver lobectomy in the dog for intraoperative blood loss and surgical time," Vet. Surg. 39(7), 856-862 (2010).
    • (2010) Vet. Surg. , vol.39 , Issue.7 , pp. 856-862
    • Risselada, M.1
  • 2
    • 79954998497 scopus 로고    scopus 로고
    • Bipolar vessel sealing system vs clamp crushing technique for liver parenchyma transaction
    • M. Garancini et al., "Bipolar vessel sealing system vs clamp crushing technique for liver parenchyma transaction," Hepatogastroenterology 58(105), 127-132 (2011).
    • (2011) Hepatogastroenterology , vol.58 , Issue.105 , pp. 127-132
    • Garancini, M.1
  • 5
    • 34247185187 scopus 로고    scopus 로고
    • Comparing the ultrasonically activated scalpel (harmonic) with high-frequency electrocautery for postoperative serous drainage in massive weight loss surgery [11]
    • DOI 10.1097/01.prs.0000278224.14221.c9, PII 0000653420070915000047
    • A. Stoff, M. A. Reichenberger, and D. F. Richter, "Comparing the ultrasonically activated scalpel (Harmonic) with high-frequency electrocautery for postoperative serious drainage in massive weight loss surgery," Plast. Reconstr. Surg. 120(4), 1092-1093 (2007). (Pubitemid 47367920)
    • (2007) Plastic and Reconstructive Surgery , vol.120 , Issue.4 , pp. 1092-1093
    • Stoff, A.1    Reichenberger, M.A.2    Richter, D.F.3
  • 6
    • 43849104172 scopus 로고    scopus 로고
    • Impact of technological advances on complications of revisional bariatric operations
    • R. E. Brolin and R. P. Cody, "Impact of technological advances on complications of revisional bariatric operations," J. Am. Coll. Surg. 206(6), 1137-1144 (2008).
    • (2008) J. Am. Coll. Surg. , vol.206 , Issue.6 , pp. 1137-1144
    • Brolin, R.E.1    Cody, R.P.2
  • 7
    • 84856138706 scopus 로고    scopus 로고
    • New energy-based devices in laparoscopic splenectomy: Comparison of Ligasure alone versus Ligasure and Ultracision together
    • Y. Kurt et al., "New energy-based devices in laparoscopic splenectomy: comparison of Ligasure alone versus Ligasure and Ultracision together," Surg. Pract. 16(1), 28-32 (2012).
    • (2012) Surg. Pract. , vol.16 , Issue.1 , pp. 28-32
    • Kurt, Y.1
  • 8
    • 84859649883 scopus 로고    scopus 로고
    • Laparoscopic splenectomy: Ligasure or clip ligation?
    • H. Shabadong et al., "Laparoscopic splenectomy: ligasure or clip ligation?" Surg. Laparosc. Endosc. Percutan. Tech. 22(2), 136-138 (2012).
    • (2012) Surg. Laparosc. Endosc. Percutan. Tech. , vol.22 , Issue.2 , pp. 136-138
    • Shabadong, H.1
  • 9
    • 0035005293 scopus 로고    scopus 로고
    • Electrosurgery in otolaryngology-head and neck surgery: Principles, advances, and complications
    • T. L. Smith and J. M. Smith, "Electrosurgery in otolaryngology-head and neck surgery: principles, advances, and complications," Laryngoscope 111(5), 769-780 (2001). (Pubitemid 32422766)
    • (2001) Laryngoscope , vol.111 , Issue.5 , pp. 769-780
    • Smith, T.L.1    Smith, J.M.2
  • 10
    • 33947618422 scopus 로고    scopus 로고
    • Ligasure vessel sealing system versus conventional vessel ligation in thyroidectomy
    • U. Lepner and T. Vaasna, "Ligasure vessel sealing system versus conventional vessel ligation in thyroidectomy," Scand. J. Surg. 96(1), 31-34 (2007). (Pubitemid 46493761)
    • (2007) Scandinavian Journal of Surgery , vol.96 , Issue.1 , pp. 31-34
    • Lepner, U.1    Vaasna, T.2
  • 11
    • 70349310087 scopus 로고    scopus 로고
    • Comparison of LigaSure vessel sealing system, harmonic scalpel, and conventional hemostasis in total thyroidectomy
    • Y. Pons et al., "Comparison of LigaSure vessel sealing system, harmonic scalpel, and conventional hemostasis in total thyroidectomy," Otolaryngol. Head Neck Surg. 141(4), 496-501 (2009).
    • (2009) Otolaryngol. Head Neck Surg. , vol.141 , Issue.4 , pp. 496-501
    • Pons, Y.1
  • 12
    • 77952303286 scopus 로고    scopus 로고
    • The use of the Ligasure vessel sealing system in head and neck surgery: A report on six years of experience and a review of the literature
    • E. P. Prokopakis et al., "The use of the Ligasure vessel sealing system in head and neck surgery: a report on six years of experience and a review of the literature," B-ENT 6(1), 19-25 (2010).
    • (2010) B-ENT 6 , Issue.1 , pp. 19-25
    • Prokopakis, E.P.1
  • 13
    • 78651351898 scopus 로고    scopus 로고
    • A comparison of the Ligasure and harmonic scalpel in thyroid surgery: A single institution review
    • B. Zarebczan, D. Mohanty, and H. Chen, "A comparison of the Ligasure and harmonic scalpel in thyroid surgery: a single institution review," Ann. Surg. Oncol. 18(1), 214-218 (2011).
    • (2011) Ann. Surg. Oncol. , vol.18 , Issue.1 , pp. 214-218
    • Zarebczan, B.1    Mohanty, D.2    Chen, H.3
  • 14
    • 79960782049 scopus 로고    scopus 로고
    • Sutureless thyroidectomy: Surgical technique
    • C. J. O'Neill et al., "Sutureless thyroidectomy: surgical technique," ANZ J. Surg. 81(7-8), 515-518 (2011).
    • (2011) ANZ J. Surg. , vol.81 , Issue.7-8 , pp. 515-518
    • O'neill, C.J.1
  • 15
    • 80054922282 scopus 로고    scopus 로고
    • Energy-based vessel sealing in vaginal hysterectomy: A systematic review and meta-analysis
    • J. Kroft and A. Selk, "Energy-based vessel sealing in vaginal hysterectomy: a systematic review and meta-analysis," Obstet. Gynecol. 118(5), 1127-1136 (2011).
    • (2011) Obstet. Gynecol. , vol.118 , Issue.5 , pp. 1127-1136
    • Kroft, J.1    Selk, A.2
  • 16
    • 0034745423 scopus 로고    scopus 로고
    • Harmonic scalpel in laparoscopic colorectal surgery
    • S. Msilka et al., "Harmonic scalpel in laparoscopic colorectal surgery," Dis. Colon. Rectum 44(3), 432-436 (2001).
    • (2001) Dis. Colon. Rectum , vol.44 , Issue.3 , pp. 432-436
    • Msilka, S.1
  • 17
    • 66849115094 scopus 로고    scopus 로고
    • Electrothermal biopolar vessel sealing system vs. Harmonic scalpel in colorectal laparoscopic surgery; A prospective, randomized study
    • R. Rimonda et al., "Electrothermal biopolar vessel sealing system vs. harmonic scalpel in colorectal laparoscopic surgery; a prospective, randomized study," Dis. Colon. Rectum 52(4), 657-661 (2009).
    • (2009) Dis. Colon. Rectum , vol.52 , Issue.4 , pp. 657-661
    • Rimonda, R.1
  • 18
    • 84856371079 scopus 로고    scopus 로고
    • Randomized clinical trial comparing the cost and effectiveness of bipolar vessel sealers versus clips and vascular staplers for laparoscopic colorectal resection
    • M. Adamina et al., "Randomized clinical trial comparing the cost and effectiveness of bipolar vessel sealers versus clips and vascular staplers for laparoscopic colorectal resection," Br. J. Surg. 98(12), 1703-1712 (2011).
    • (2011) Br. J. Surg. , vol.98 , Issue.12 , pp. 1703-1712
    • Adamina, M.1
  • 19
    • 79959490978 scopus 로고    scopus 로고
    • Energy source instruments for laparoscopic colectomy
    • S. Tou et al., "Energy source instruments for laparoscopic colectomy," Cochrane Database Syst. Rev. (5), CD007886 (2011).
    • (2011) Cochrane Database Syst. Rev. , Issue.5
    • Tou, S.1
  • 21
    • 54249164559 scopus 로고    scopus 로고
    • Prospective comparison of four laparoscopic vessel ligation devices
    • G. R. Lamberton et al., "Prospective comparison of four laparoscopic vessel ligation devices," J. Endourol. 22(10), 2307-2312 (2008).
    • (2008) J. Endourol. , vol.22 , Issue.10 , pp. 2307-2312
    • Lamberton, G.R.1
  • 22
    • 76649095294 scopus 로고    scopus 로고
    • Comparison of lateral thermal spread using monopolar and bipolar diathermy, the Harmonic scalpel, and the Ligasure
    • P. A. Sutton et al., "Comparison of lateral thermal spread using monopolar and bipolar diathermy, the Harmonic scalpel, and the Ligasure," Br. J. Surg. 97(3), 428-433 (2010).
    • (2010) Br. J. Surg. , vol.97 , Issue.3 , pp. 428-433
    • Sutton, P.A.1
  • 23
    • 0015604413 scopus 로고
    • Optical constants of water in the 200 nm to 200 μm wavelength region
    • G. M. Hale and M. R. Querry, "Optical constants of water in the 200 nm to 200 μm wavelength region," Appl. Opt. 12(3), 555-563 (1973).
    • (1973) Appl. Opt. , vol.12 , Issue.3 , pp. 555-563
    • Hale, G.M.1    Querry, M.R.2
  • 24
    • 78649661089 scopus 로고    scopus 로고
    • Anevaluation of electrosurgical vessel-sealing devices in biliary tract surgery in a porcine model
    • W.W.Hopeet al., "Anevaluation of electrosurgical vessel-sealing devices in biliary tract surgery in a porcine model," HPB12(10), 703-708 (2010).
    • (2010) HPB1 , vol.2 , Issue.10 , pp. 703-708
    • Hope, W.W.1
  • 25
    • 58149177521 scopus 로고    scopus 로고
    • Comparison of blood vessel sealing among new electrosurgical and ultrasonic devices
    • W. L. Newcomb et al., "Comparison of blood vessel sealing among new electrosurgical and ultrasonic devices," Surg. Endosc. 23(1), 90-96 (2009).
    • (2009) Surg. Endosc. , vol.23 , Issue.1 , pp. 90-96
    • Newcomb, W.L.1
  • 26
    • 0037306077 scopus 로고    scopus 로고
    • Evaluation of a vessel sealing system, bipolar electrosurgery, harmonic scalpel, titanium clips, endoscopic gastrointestinal anastomosis vascular staples and sutures for arterial and venous ligation in a porcine model
    • DOI 10.1016/S0022-5347(05)63995-X
    • J. Landman et al., "Evaluation of a vessel sealing system, bipolar electrosurgery, harmonic scalpel, titanium clips, endoscopic gastrointestinal anastomosis vascular staples and sutures for arterial and venous ligation in a porcine model," J. Urol. 169(2), 697-700 (2003). (Pubitemid 36133025)
    • (2003) Journal of Urology , vol.169 , Issue.2 , pp. 697-700
    • Landman, J.1    Kerbl, K.2    Rehman, J.3    Andreoni, C.4    Humphrey, P.A.5    Collyer, W.6    Olweny, E.7    Sundaram, C.8    Clayman, R.V.9
  • 27
    • 39149134560 scopus 로고    scopus 로고
    • Comparison of four energy-based vascular sealing and cutting instruments: A porcine model
    • B. Person et al., "Comparison of four energy-based vascular sealing and cutting instruments: a porcine model," Surg. Endosc. 22(2), 534-538 (2008).
    • (2008) Surg. Endosc. , vol.22 , Issue.2 , pp. 534-538
    • Person, B.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.