메뉴 건너뛰기




Volumn 11, Issue 10, 2013, Pages 1407-1416

Looking into the future with bioresorbable vascular scaffolds

Author keywords

Bioresorbable stent; Bioresorbable vascular scaffold; Drug eluting stent; Stent thrombosis; Target lesion revascularization

Indexed keywords

EVEROLIMUS; PACLITAXEL; RAPAMYCIN;

EID: 84886614337     PISSN: 14779072     EISSN: 17448344     Source Type: Journal    
DOI: 10.1586/14779072.2013.839200     Document Type: Review
Times cited : (24)

References (31)
  • 1
    • 0346668290 scopus 로고    scopus 로고
    • Influence of stent design and deployment technique on neointima formation and vascular remodeling
    • Konig A, Schiele TM, Rieber J et al. Influence of stent design and deployment technique on neointima formation and vascular remodeling. Z. Kardiol. 91 (Suppl. 3), 98-102 (2002).
    • (2002) Z. Kardiol. , vol.91 , Issue.SUPPL. 3 , pp. 98-102
    • Konig, A.1    Schiele, T.M.2    Rieber, J.3
  • 2
    • 79952414020 scopus 로고    scopus 로고
    • The pathology of neoatherosclerosis in human coronary implants bare-metal and drug-eluting stents
    • Nakazawa G, Otsuka F, Nakano M et al. The pathology of neoatherosclerosis in human coronary implants bare-metal and drug-eluting stents. JACC 57, 1314-1322 (2011).
    • (2011) JACC , vol.57 , pp. 1314-1322
    • Nakazawa, G.1    Otsuka, F.2    Nakano, M.3
  • 3
    • 10744229988 scopus 로고    scopus 로고
    • Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: Should we be cautious?
    • Virmani R, Guagliumi G, Farb A et al. Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: Should we be cautious? Circulation 109, 701-705 (2004).
    • (2004) Circulation , vol.109 , pp. 701-705
    • Virmani, R.1    Guagliumi, G.2    Farb, A.3
  • 4
    • 0038486163 scopus 로고    scopus 로고
    • Biocorrosion of magnesium alloys: A new principle in cardiovascular implant technology?
    • Heublein B, Rohde R, Kaese V, Niemeyer M, Hartung W, Haverich A. Biocorrosion of magnesium alloys: A new principle in cardiovascular implant technology? Heart 89, 651-656 (2003).
    • (2003) Heart , vol.89 , pp. 651-656
    • Heublein, B.1    Rohde, R.2    Kaese, V.3    Niemeyer, M.4    Hartung, W.5    Haverich, A.6
  • 5
    • 34249655184 scopus 로고    scopus 로고
    • Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents: A prospective, non-randomised multicentre trial
    • Erbel R, Di Mario C, Bartunek J et al. Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents: A prospective, non-randomised multicentre trial. Lancet 369, 1869-1875 (2007).
    • (2007) Lancet , vol.369 , pp. 1869-1875
    • Erbel, R.1    Di Mario, C.2    Bartunek, J.3
  • 6
    • 84879768562 scopus 로고    scopus 로고
    • Progress with drug-eluting magnesium resorbing stents (BIOTRONIK dreams program): DREAMS 2-year results
    • (TCT) Conference. Miami, FL, USA 22-26 October 2012.
    • Haude M. Progress with drug-eluting magnesium resorbing stents (BIOTRONIK dreams program): DREAMS 2-year results. Presented at: Transcatheter Cardiovascular Therapeutics (TCT) Conference. Miami, FL, USA, 22-26 October 2012.
    • Presented at: Transcatheter Cardiovascular Therapeutics
    • Haude, M.1
  • 7
    • 84886602061 scopus 로고    scopus 로고
    • Lessons learned from preclinical studies of magnesium scaffolds (biotronik's dreams program)
    • Rotterdam NL 8-9 March 2012.
    • Waksman R. Lessons learned from preclinical studies of magnesium scaffolds (Biotronik's DREAMS program). Presented at: PCR focus group on bioresorbable vascular scaffolds. Rotterdam, NL, 8-9 March 2012.
    • Presented At: PCR Focus Group On Bioresorbable Vascular Scaffolds
    • Waksman, R.1
  • 8
    • 40649083620 scopus 로고    scopus 로고
    • A bioabsorbable everolimus-eluting coronary stent system for patients with single de novo coronary artery lesions (ABSORB): A prospective open label trial
    • Ormiston JA, Serruys PW, Regar E et al. A bioabsorbable everolimus-eluting coronary stent system for patients with single de novo coronary artery lesions (ABSORB): A prospective open label trial. Lancet 371, 899-907 (2008).
    • (2008) Lancet , vol.371 , pp. 899-907
    • Ormiston, J.A.1    Serruys, P.W.2    Regar, E.3
  • 9
    • 55049109584 scopus 로고    scopus 로고
    • Late stent recoil of the bioabsorbable everolimus-eluting coronary stent and its relationship with plaque morphology
    • Tanimoto S, Bruining N, van Domburg RT et al. Late stent recoil of the bioabsorbable everolimus-eluting coronary stent and its relationship with plaque morphology. J. Am. Coll. Cardiol. 52, 1616-1620 (2008).
    • (2008) J. Am. Coll. Cardiol. , vol.52 , pp. 1616-1620
    • Tanimoto, S.1    Bruining, N.2    Van Domburg, R.T.3
  • 10
    • 80053325761 scopus 로고    scopus 로고
    • Evaluation of the second generation of a bioresorbable everolimus-eluting vascular scaffold for the treatment of de novo coronary artery stenosis: 12-month clinical and imaging outcomes
    • Serruys PW, Onuma Y, Dudek D et al. Evaluation of the second generation of a bioresorbable everolimus-eluting vascular scaffold for the treatment of de novo coronary artery stenosis: 12-month clinical and imaging outcomes. J. Am. Coll. Cardiol. 58 (15), 1578-88 (2011).
    • (2011) J. Am. Coll. Cardiol. , vol.58 , Issue.15 , pp. 1578-1588
    • Serruys, P.W.1    Onuma, Y.2    Dudek, D.3
  • 11
    • 61849110613 scopus 로고    scopus 로고
    • A bioabsorbable everolimus-eluting coronary stent system (ABSORB): 2-year outcomes and results from multiple imaging methods
    • Serruys PW, Ormiston JA, Onuma Y et al. A bioabsorbable everolimus-eluting coronary stent system (ABSORB): 2-year outcomes and results from multiple imaging methods. Lancet 373, 897-910 (2009).
    • (2009) Lancet , vol.373 , pp. 897-910
    • Serruys, P.W.1    Ormiston, J.A.2    Onuma, Y.3
  • 12
    • 84886629826 scopus 로고    scopus 로고
    • on behalf of the ABSORB A & B investigators. ABSORB Cohort B: 6 m, 12 m, 18 m and 24 m follow-up. Rotterdam, NL 8-9 March 2012.
    • Serruys PW, Onuma Y, on behalf of the ABSORB A & B investigators. ABSORB Cohort B: 6 m, 12 m, 18 m and 24 m follow-up. Presented at: PCR Focus Group on Bioresorbable Vascular Scaffolds. Rotterdam, NL, 8-9 March 2012.
    • Presented at: PCR Focus Group on Bioresorbable Vascular Scaffolds
    • Serruys, P.W.1    Onuma, Y.2
  • 13
    • 84871726767 scopus 로고    scopus 로고
    • Clinical and intravascular imaging outcomes at 1 and 2 years after implantation of absorb everolimus eluting bioresorbable vascular scaffolds in small vessels. Late lumen enlargement: Does bioresorption matter with small vessel size? Insight from the ABSORB cohort Btrial
    • 98.iss
    • Diletti R, Farooq V, Girasis C et al. Clinical and intravascular imaging outcomes at 1 and 2 years after implantation of absorb everolimus eluting bioresorbable vascular scaffolds in small vessels. Late lumen enlargement: Does bioresorption matter with small vessel size? Insight from the ABSORB cohort Btrial. Heart 99, 98-105, (2013)
    • (2013) Heart , vol.99
    • Diletti, R.1    Farooq, V.2    Girasis, C.3
  • 14
    • 84886607326 scopus 로고    scopus 로고
    • BVS expand: First result of wide clinical applications of bioresorbable vascular scaffold
    • Paris, FRA 21-24 May 2013.
    • Van Geuns R. BVS expand: First result of wide clinical applications of Bioresorbable Vascular Scaffold. Presented at: EuroPCR. Paris, FRA, 21-24 May 2013.
    • Presented at: EuroPCR
    • Van Geuns, R.1
  • 15
    • 84886629938 scopus 로고    scopus 로고
    • Bioresorbable vascular scaffolds (bvs) in patients with acute coronary syndrome the muticenter registry in poland: Polar acs
    • FRA 21-24 May 2013.
    • Dudek D, Rzeszutko A, Lekston A et al. Bioresorbable Vascular Scaffolds (BVS) in patients with acute coronary syndrome. The muticenter registry in Poland: POLAR ACS. Presented at: EuroPCR. Paris, FRA, 21-24 May 2013.
    • Presented at: EuroPCR. Paris
    • Dudek, D.1    Rzeszutko, A.2    Lekston, A.3
  • 19
    • 84886614778 scopus 로고    scopus 로고
    • First-in-man results with a myolimus-eluting bioresorbable plla-based vascular scaffold (elixir desolve)
    • on behalf of the DESolve investigators. Miami, FL, USA 22-26 October 2012.
    • Verheye S, on behalf of the DESolve investigators. First-in-Man results with a Myolimus-Eluting bioresorbable PLLA-based vascular scaffold (Elixir DESolve). Presented at: Transcatheter Cardiovascular Therapeutics (TCT) Conference. Miami, FL, USA, 22-26 October 2012.
    • Presented at: Transcatheter Cardiovascular Therapeutics (TCT) Conference
    • Verheye, S.1
  • 20
    • 77956155827 scopus 로고    scopus 로고
    • Poly-Anhydride based on salicylic acid and adipic acid anhydride
    • 19-22 May
    • Jabara R. Poly-Anhydride based on salicylic acid and adipic acid anhydride. Presented at: EuroPCR. Barcelona, SPN, 19-22 May 2009.
    • (2009) Presented at: EuroPCR. Barcelona SPN
    • Jabara, R.1
  • 22
    • 77956141152 scopus 로고    scopus 로고
    • Bioabsorbable stent. The Boston scientific and REVA technology
    • 19-22 May
    • Grube E. Bioabsorbable stent. The Boston scientific and REVA technology. Presented at: EuroPCR. Barcelona, SPN, 19-22 May 2009.
    • (2009) Presented at: EuroPCR. Barcelona SPN
    • Grube, E.1
  • 23
  • 24
    • 77956150805 scopus 로고    scopus 로고
    • OrbusNeich fully absorbable coronary stent platform incorporating dual partitioned coatings
    • Cottone RJ, Thatcher GL, Parker SP et al. OrbusNeich fully absorbable coronary stent platform incorporating dual partitioned coatings. EuroIntervention 5 (Suppl. F), F65-71 (2009).
    • (2009) EuroIntervention , vol.5 , Issue.SUPPL. F
    • Cottone, R.J.1    Thatcher, G.L.2    Parker, S.P.3
  • 26
    • 0007488634 scopus 로고    scopus 로고
    • Initial and 6-month results of biodegradable poly-l-lactic acid coronary stents in humans
    • Tamai H, Igaki K, Kyo E et al. Initial and 6-month results of biodegradable poly-l-lactic acid coronary stents in humans. Circulation 102, 399-404 (2000).
    • (2000) Circulation , vol.102 , pp. 399-404
    • Tamai, H.1    Igaki, K.2    Kyo, E.3
  • 27
    • 84861231496 scopus 로고    scopus 로고
    • Long-Term (>10 years) clinical outcomes of first-in-man biodegradable poly-l-lactic acid coronary stents: Igaki-Tamai Stents
    • Nishio S, Kosuga K, Igaki K et al. Long-Term (>10 years) clinical outcomes of first-in-man biodegradable poly-l-lactic acid coronary stents: Igaki-Tamai Stents. Circulation 125, 2343-2353 (2012).
    • (2012) Circulation , vol.125 , pp. 2343-2353
    • Nishio, S.1    Kosuga, K.2    Igaki, K.3
  • 29
    • 78449238318 scopus 로고    scopus 로고
    • A comparison of the conformability of everolimus-eluting bioresorbable vascular scaffolds to metal platform coronary stents
    • Gomez-Lara J, Garcia-Garcia HM, Onuma Y et al. A comparison of the conformability of everolimus-eluting bioresorbable vascular scaffolds to metal platform coronary stents. JACC Cardiovasc. Interv. 3, 1190-1198 (2010).
    • (2010) JACC Cardiovasc. Interv. , vol.3 , pp. 1190-1198
    • Gomez-Lara, J.1    Garcia-Garcia, H.M.2    Onuma, Y.3
  • 30
    • 70049112142 scopus 로고    scopus 로고
    • Ostial and midshaft lesions vs bifurcation lesions in 1111 patients with unprotected left main coronary artery stenosis treated with drug-eluting stents: Results of the survey from the italian society of invasive cardiology
    • Palmerini T, Sangiorgi D, Marzocchi A et al. Ostial and midshaft lesions vs. bifurcation lesions in 1111 patients with unprotected left main coronary artery stenosis treated with drug-eluting stents: Results of the survey from the Italian Society of Invasive Cardiology. Eur. Heart J. 30, 2087-2094 (2009).
    • (2009) Eur. Heart J. , vol.30 , pp. 2087-2094
    • Palmerini, T.1    Sangiorgi, D.2    Marzocchi, A.3
  • 31
    • 77953748337 scopus 로고    scopus 로고
    • The fate of incomplete stent apposition with drug-eluting stents: An optical coherence tomography-based natural history study
    • Ozaki Y, Okumura M, Ismail TF et al. The fate of incomplete stent apposition with drug-eluting stents: An optical coherence tomography-based natural history study. Eur. Heart J. 31, 1470-1476 (2010).
    • (2010) Eur. Heart J. , vol.31 , pp. 1470-1476
    • Ozaki, Y.1    Okumura, M.2    Ismail, T.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.