메뉴 건너뛰기




Volumn 28, Issue 2, 2013, Pages 837-846

Primary frequency regulation by deloaded wind turbines using variable droop

Author keywords

Deloading; Doubly fed induction generator; Droop; Primary frequency regulation; Wind turbine

Indexed keywords

DELOADING; DOUBLY FED INDUCTION-GENERATOR; DROOP; POWER FLUCTUATIONS; PREVAILING WINDS; PRIMARY FREQUENCIES; PRIMARY FREQUENCY REGULATION; VARIABLE SPEED WIND TURBINES;

EID: 84886399372     PISSN: 08858950     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPWRS.2012.2208233     Document Type: Article
Times cited : (633)

References (37)
  • 1
    • 28244449042 scopus 로고    scopus 로고
    • Frequency control and wind turbine technologies
    • Nov.
    • G. Lalor, A. Mullane, and M. O'Malley, "Frequency control and wind turbine technologies," IEEE Trans. Power Syst., vol. 20, no. 4, pp. 1905-1913, Nov. 2005.
    • (2005) IEEE Trans. Power Syst. , vol.20 , Issue.4 , pp. 1905-1913
    • Lalor, G.1    Mullane, A.2    O'Malley, M.3
  • 2
    • 10244250325 scopus 로고    scopus 로고
    • Comparison of the response of doubly fed and fixed-speed induction generator wind turbines to changes in network frequency
    • Dec.
    • J. Ekanayake and N. Jenkins, "Comparison of the response of doubly fed and fixed-speed induction generator wind turbines to changes in network frequency," IEEE Trans. Energy Convers., vol. 19, no. 4, pp. 800-803, Dec. 2004.
    • (2004) IEEE Trans. Energy Convers. , vol.19 , Issue.4 , pp. 800-803
    • Ekanayake, J.1    Jenkins, N.2
  • 3
    • 28244480269 scopus 로고    scopus 로고
    • Control of DFIG-based wind generation for power network support
    • Nov.
    • F. M. Hughes, O. Anaya-Lara, N. Jenkins, and G. Strbac, "Control of DFIG-based wind generation for power network support," IEEE Trans. Power Syst., vol. 20, no. 4, pp. 1958-1966, Nov. 2005.
    • (2005) IEEE Trans. Power Syst. , vol.20 , Issue.4 , pp. 1958-1966
    • Hughes, F.M.1    Anaya-Lara, O.2    Jenkins, N.3    Strbac, G.4
  • 7
    • 43849103784 scopus 로고    scopus 로고
    • Temporary primary frequency control support by variable speed wind turbines-Potential and applications
    • May
    • N. R. Ullah, T. Thiringer, and D. Karlsson, "Temporary primary frequency control support by variable speed wind turbines-Potential and applications," IEEE Trans. Power Syst., vol. 23, no. 2, pp. 601-612, May 2008.
    • (2008) IEEE Trans. Power Syst. , vol.23 , Issue.2 , pp. 601-612
    • Ullah, N.R.1    Thiringer, T.2    Karlsson, D.3
  • 8
    • 34247185867 scopus 로고    scopus 로고
    • Frequency support fromdoubly fed induction generatorwind turbines
    • Mar.
    • G. Ramtharan, J. B. Ekanayake, and N. Jenkins, "Frequency support fromdoubly fed induction generatorwind turbines," IET Renew. Power Gen., pp. 3-9, Mar. 2007.
    • (2007) IET Renew. Power Gen. , pp. 3-9
    • Ramtharan, G.1    Ekanayake, J.B.2    Jenkins, N.3
  • 9
    • 34548030937 scopus 로고    scopus 로고
    • Participation of doubly fed induction wind generators in system frequency regulation
    • Aug.
    • R. G. de Almeida and J. Lopes, "Participation of doubly fed induction wind generators in system frequency regulation," IEEE Trans. Power Syst., vol. 22, no. 3, pp. 944-950, Aug. 2007.
    • (2007) IEEE Trans. Power Syst. , vol.22 , Issue.3 , pp. 944-950
    • De Almeida, R.G.1    Lopes, J.2
  • 10
    • 30944433591 scopus 로고    scopus 로고
    • Centralised power control of wind farm with doubly fed induction generators
    • A. D. Hansen, P. Sørensen, F. Iov, and F. Blaabjerg, "Centralised power control of wind farm with doubly fed induction generators," Renew. Energy, vol. 31, pp. 935-951, 2006.
    • (2006) Renew. Energy , vol.31 , pp. 935-951
    • Hansen, A.D.1    Sørensen, P.2    Iov, F.3    Blaabjerg, F.4
  • 11
    • 67349262621 scopus 로고    scopus 로고
    • Dynamic contribution of DFIG-based wind plants to system frequency disturbances
    • May
    • M. Kayikci and J. V. Milanovic, "Dynamic contribution of DFIG-based wind plants to system frequency disturbances," IEEE Trans. Power Syst., vol. 24, no. 2, pp. 859-867, May 2009.
    • (2009) IEEE Trans. Power Syst. , vol.24 , Issue.2 , pp. 859-867
    • Kayikci, M.1    Milanovic, J.V.2
  • 12
    • 54349100442 scopus 로고    scopus 로고
    • Experimental study of variable speed wind generator contribution to primary frequency control
    • M. E. Mokadem, V. Courtecuisse, C. Saudemont, B. Robyns, and J. Deuse, "Experimental study of variable speed wind generator contribution to primary frequency control," Renew. Energy, vol. 34, pp. 833-844, 2009.
    • (2009) Renew. Energy , vol.34 , pp. 833-844
    • Mokadem, M.E.1    Courtecuisse, V.2    Saudemont, C.3    Robyns, B.4    Deuse, J.5
  • 13
    • 79955541414 scopus 로고    scopus 로고
    • Enhancing frequency response control by DFIGs in the high wind penetrated power systems
    • May
    • L.-R. Chang-Chien, W.-T. Lin, and Y.-C. Yin, "Enhancing frequency response control by DFIGs in the high wind penetrated power systems," IEEE Trans. Power Syst., vol. 26, no. 2, pp. 710-718, May 2011.
    • (2011) IEEE Trans. Power Syst. , vol.26 , Issue.2 , pp. 710-718
    • Chang-Chien, L.-R.1    Lin, W.-T.2    Yin, Y.-C.3
  • 17
    • 0037291008 scopus 로고    scopus 로고
    • General model for representing variable speed wind turbines in power system dynamics simulations
    • Feb.
    • J. G. Slootweg, S. W. H. de Haan, H. Polinder, and W. L. Kling, "General model for representing variable speed wind turbines in power system dynamics simulations," IEEE Trans. Power Syst., vol. 18, no. 1, pp. 144-151, Feb. 2003.
    • (2003) IEEE Trans. Power Syst. , vol.18 , Issue.1 , pp. 144-151
    • Slootweg, J.G.1    De Haan, S.W.H.2    Polinder, H.3    Kling, W.L.4
  • 19
    • 84860299481 scopus 로고    scopus 로고
    • MPPT control methods in wind energy conversion systems
    • R. Carriveau, Ed., [Online]. Available
    • J. S. Thongam and M. Ouhrouche, "MPPT control methods in wind energy conversion systems," Fundamental and Advanced Topics in Wind Power, R. Carriveau, Ed., InTech, 2011, pp. 339-360. [Online]. Available: http://www.intechopen.com.
    • (2011) Fundamental and Advanced Topics in Wind Power , pp. 339-360
    • Thongam, J.S.1    Ouhrouche, M.2
  • 21
    • 14744306666 scopus 로고    scopus 로고
    • Optimization of variable speed wind power systems based on a LQG approach
    • I. Munteanu, N. A. Cutululis, A. I. Bratcu, and E. Ceanga, "Optimization of variable speed wind power systems based on a LQG approach," Control Eng. Practice, vol. 13, pp. 903-912, 2005.
    • (2005) Control Eng. Practice , vol.13 , pp. 903-912
    • Munteanu, I.1    Cutululis, N.A.2    Bratcu, A.I.3    Ceanga, E.4
  • 22
    • 32144457162 scopus 로고    scopus 로고
    • Wind turbines emulating inertia and supporting primary frequency control
    • Feb.
    • J. Morren, S. W. H. de Haan, and W. L. Kling, "Wind turbines emulating inertia and supporting primary frequency control," IEEE Trans. Power Syst., vol. 21, no. 1, pp. 433-434, Feb. 2006.
    • (2006) IEEE Trans. Power Syst. , vol.21 , Issue.1 , pp. 433-434
    • Morren, J.1    De Haan, S.W.H.2    Kling, W.L.3
  • 24
    • 0026397758 scopus 로고
    • An adaptive control scheme for speed control of diesel driven power-plants
    • Dec.
    • S. Roy, O. P. Malik, and G. S. Hope, "An adaptive control scheme for speed control of diesel driven power-plants," IEEE Trans. Energy Convers., vol. 6, no. 4, pp. 605-611, Dec. 1991.
    • (1991) IEEE Trans. Energy Convers. , vol.6 , Issue.4 , pp. 605-611
    • Roy, S.1    Malik, O.P.2    Hope, G.S.3
  • 29
    • 84868331816 scopus 로고    scopus 로고
    • Central Electricity Regulatory Commission, Apr. [Online]. Available
    • Central Electricity Regulatory Commission, Indian electricity grid code, Apr. 2010. [Online]. Available: http://www.cercind.gov.in/2010/ORDER/February 2010/IEGC-Review-Proposal.pdf.
    • (2010) Indian Electricity Grid Code
  • 30
    • 84886379994 scopus 로고    scopus 로고
    • Revision 5, Dec. [Online]. Available
    • National Grid Electricity Transmission plc, The Grid Code, no. 4, Revision 5, Dec. 2010. [Online]. Available: http://www.nationalgrid.com/NR/ rdonlyres/67374C36-1635-42E8-A2B8-B7B8B9AF2408/44739/Z-Complete Grid Code-I4R5.pdf.
    • (2010) The Grid Code , Issue.4
  • 31
    • 84886400645 scopus 로고    scopus 로고
    • Rihand super thermal power station, NTPC Ltd., India
    • "O&M Data Book," Rihand super thermal power station, NTPC Ltd., India.
    • O&M Data Book
  • 32
    • 57349138926 scopus 로고    scopus 로고
    • Energy management in autonomous microgrid using stability-constrained droop control of inverters
    • Sep.
    • E. Barklund, N. Pogaku, M. Prodanovic, C. H. Aramburo, and T. C. Green, "Energy management in autonomous microgrid using stability-constrained droop control of inverters," IEEE Trans. Power Electron., vol. 23, no. 5, pp. 2346-2352, Sep. 2008.
    • (2008) IEEE Trans. Power Electron. , vol.23 , Issue.5 , pp. 2346-2352
    • Barklund, E.1    Pogaku, N.2    Prodanovic, M.3    Aramburo, C.H.4    Green, T.C.5
  • 33
    • 0035370675 scopus 로고    scopus 로고
    • Reliability benefit analysis of adding WT to a distribution system
    • Jun.
    • P. Wang and R. Billinton, "Reliability benefit analysis of adding WT to a distribution system," IEEE Trans. Energy Convers., vol. 16, no. 2, pp. 134-139, Jun. 2001.
    • (2001) IEEE Trans. Energy Convers. , vol.16 , Issue.2 , pp. 134-139
    • Wang, P.1    Billinton, R.2
  • 36
    • 77954310623 scopus 로고    scopus 로고
    • Performance, reliability and failure analysis of wind farm in a developing country
    • G. M. J. Herbert, S. Iniyan, and R. Goic, "Performance, reliability and failure analysis of wind farm in a developing country," Renew. Energy, vol. 35, pp. 2739-2751, 2010.
    • (2010) Renew. Energy , vol.35 , pp. 2739-2751
    • Herbert, G.M.J.1    Iniyan, S.2    Goic, R.3
  • 37
    • 84886395099 scopus 로고    scopus 로고
    • [Online]. Available
    • [Online]. Available: http://www.instrumart.com/assets/108/an400- datasheet.pdf.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.