메뉴 건너뛰기




Volumn 13, Issue 7, 2013, Pages 8997-9015

Sensorized garments and textrode-enabled measurement instrumentation for ambulatory assessment of the autonomic nervous system response in the ATREC project

Author keywords

Bioimpedance; GSR; Heart rate; Mental stress; Non invasive measurement; Textile electrodes

Indexed keywords

ELECTROPHYSIOLOGY; INSTRUMENTS; PHYSIOLOGICAL MODELS; RISK ASSESSMENT; TEXTILES;

EID: 84886394014     PISSN: 14248220     EISSN: None     Source Type: Journal    
DOI: 10.3390/s130708997     Document Type: Article
Times cited : (35)

References (51)
  • 1
    • 14844336388 scopus 로고    scopus 로고
    • Research and development of smart wearable health applications: The challenge ahead
    • Lymberis, A. Research and development of smart wearable health applications: The challenge ahead. Stud. Health Technol. Inform. 2004, 108, 155-161.
    • (2004) Stud. Health Technol. Inform , vol.108 , pp. 155-161
    • Lymberis, A.1
  • 2
    • 33744918647 scopus 로고    scopus 로고
    • The Agenda of Wearable Healthcare
    • Schattauer: Stuttgart, Germany
    • Troster, G. The Agenda of Wearable Healthcare. In IMIA Yearbook of Medical Informatics; Schattauer: Stuttgart, Germany, 2005; pp. 125-138.
    • (2005) IMIA Yearbook of Medical Informatics , pp. 125-138
    • Troster, G.1
  • 3
    • 73049087409 scopus 로고    scopus 로고
    • A survey on wearable sensor-based systems for health monitoring and prognosis
    • Pantelopoulos, A.; Bourbakis, N.G. A survey on wearable sensor-based systems for health monitoring and prognosis. IEEE Trans. Syst. Man Cybern. C 2010, 40, 1-12.
    • (2010) IEEE Trans. Syst. Man Cybern. C , vol.40 , pp. 1-12
    • Pantelopoulos, A.1    Bourbakis, N.G.2
  • 5
    • 84879687099 scopus 로고    scopus 로고
    • Unconscious emotions: Quantifying and logging something we are not aware of
    • Ivonin, L.; Chang, H.-M.; Chen, W.; Rauterberg, M. Unconscious emotions: Quantifying and logging something we are not aware of. Pers. Ubiquit. Comput. 2012, 17, 663-673.
    • (2012) Pers. Ubiquit. Comput , vol.17 , pp. 663-673
    • Ivonin, L.1    Chang, H.-M.2    Chen, W.3    Rauterberg, M.4
  • 6
    • 84886378557 scopus 로고    scopus 로고
    • Smart Photo Frame for Arousal Feedback-Wearable Sensors and Intelligent Healthy Work Environment
    • Nottingham, UK, 25-28 July
    • Kimmy, A.; Chen, W.; Lindsay, B. Smart Photo Frame for Arousal Feedback-Wearable Sensors and Intelligent Healthy Work Environment. In Proceedings of the 7th International Conference on Intelligent Environments, Nottingham, UK, 25-28 July 2011; pp. 685-696.
    • (2011) Proceedings of the 7th International Conference On Intelligent Environments , pp. 685-696
    • Kimmy, A.1    Chen, W.2    Lindsay, B.3
  • 7
    • 77953170181 scopus 로고    scopus 로고
    • A multimodal transducer for cardiopulmonary activity monitoring in emergency
    • Lanata, A.; Scilingo, E.P.; de Rossi, D. A multimodal transducer for cardiopulmonary activity monitoring in emergency. IEEE Trans. Inf. Technol. Biomed. 2010, 14, 817-825.
    • (2010) IEEE Trans. Inf. Technol. Biomed , vol.14 , pp. 817-825
    • Lanata, A.1    Scilingo, E.P.2    de Rossi, D.3
  • 9
    • 84055212204 scopus 로고    scopus 로고
    • Medical application and clinical validation for reliable and trustworthy physiological monitoring using functional textiles: Experience from the HeartCycle and MyHeart project
    • doi:10.1109/IEMBS.2011.6090888
    • Reiter, H.; Muehlsteff, J.; Sipila, A. Medical application and clinical validation for reliable and trustworthy physiological monitoring using functional textiles: Experience from the HeartCycle and MyHeart project. Conf. Proc. IEEE. Eng. Med. Biol. Soc. 2011, doi:10.1109/IEMBS.2011.6090888.
    • (2011) Conf. Proc. IEEE. Eng. Med. Biol. Soc
    • Reiter, H.1    Muehlsteff, J.2    Sipila, A.3
  • 10
    • 84886398421 scopus 로고    scopus 로고
    • Polar Electro Oy, Available online, accessed on 10 March
    • Polar Electro Oy. Polar H6 Hear Rate Sensor. Available online: http://www.polarusa.com/us-en/products/accessories/H6 (accessed on 10 March 2013).
    • (2013) Polar H6 Hear Rate Sensor
  • 11
    • 84886422236 scopus 로고    scopus 로고
    • Vivonoetics, Available online, accessed on 9 July
    • Vivonoetics. The Equivital TnR Product Range. Available online: http://vivonoetics.com/wp-content/downloads/Brochures/General TnRBrochureVivonoetics contact.pdf (accessed on 9 July 2013).
    • (2013) The Equivital TnR Product Range
  • 12
    • 84886403050 scopus 로고    scopus 로고
    • Nuubo. nECG shirt L1. Available online, accessed on 10 March
    • Nuubo. nECG shirt L1. Available online: http://www.nuubo.com/sites/default/themes/nuubo2/pdf/DATASHEETS_EN_shirt.pdf (accessed on 10 March 2013).
    • (2013)
  • 15
    • 0034069136 scopus 로고    scopus 로고
    • Effects of controlled breathing, Mental activity and mental stress with or without verbalization on heart rate variability
    • Bernardi, L.; Wdowczyk-Szulc, J.; Valenti, C.; Castoldi, S.; Passino, C.; Spadacini, G.; Sleight, P. Effects of controlled breathing, Mental activity and mental stress with or without verbalization on heart rate variability. J. Am. Coll. Cardiol. 2000, 35, 1462-1469.
    • (2000) J. Am. Coll. Cardiol , vol.35 , pp. 1462-1469
    • Bernardi, L.1    Wdowczyk-Szulc, J.2    Valenti, C.3    Castoldi, S.4    Passino, C.5    Spadacini, G.6    Sleight, P.7
  • 18
    • 84861562620 scopus 로고    scopus 로고
    • A stress sensor based on Galvanic Skin Response (GSR) controlled by ZigBee
    • Villarejo, M.V.; Zapirain, B.G.; Zorrilla, A.M. A stress sensor based on Galvanic Skin Response (GSR) controlled by ZigBee. Sensors 2012, 12, 6075-6101.
    • (2012) Sensors , vol.12 , pp. 6075-6101
    • Villarejo, M.V.1    Zapirain, B.G.2    Zorrilla, A.M.3
  • 27
    • 77951260582 scopus 로고    scopus 로고
    • A wearable sensor for unobtrusive, long-term assessment of electrodermal activity
    • Poh, M.-Z.; Swenson, N.C.; Picard, R.W. A wearable sensor for unobtrusive, long-term assessment of electrodermal activity. IEEE Trans. Biomed. Eng. 2010, 57, 1243-1252.
    • (2010) IEEE Trans. Biomed. Eng , vol.57 , pp. 1243-1252
    • Poh, M.-Z.1    Swenson, N.C.2    Picard, R.W.3
  • 28
    • 84861979343 scopus 로고    scopus 로고
    • Unobtrusive emotions sensing in daily life
    • Ouwerkerk, M. Unobtrusive emotions sensing in daily life. Philips Res. Book Ser. 2011, 12, 21-39.
    • (2011) Philips Res. Book Ser , vol.12 , pp. 21-39
    • Ouwerkerk, M.1
  • 29
    • 80052388972 scopus 로고    scopus 로고
    • A stress-detection system based on physiological signals and fuzzy logic
    • de Santos Sierra, A.; Avila, C.S.; Guerra Casanova, J.; del Pozo, G.B. A stress-detection system based on physiological signals and fuzzy logic. IEEE Trans. Ind. Electron. 2011, 58, 4857-4865.
    • (2011) IEEE Trans. Ind. Electron , vol.58 , pp. 4857-4865
    • de Santos, S.A.1    Avila, C.S.2    Guerra, C.J.3    del Pozo, G.B.4
  • 30
    • 27544483639 scopus 로고    scopus 로고
    • Realization of Stress Detection Using Psychophysiological Signals for Improvement of Human-Computer Interactions
    • Ft. Lauderdale, FL, USA, 8-10 April
    • Zhai, J.; Barreto, A.B.; Chin, C.; Chao, L. Realization of Stress Detection Using Psychophysiological Signals for Improvement of Human-Computer Interactions. In Proceedings of the IEEE SoutheastCon2005, Ft. Lauderdale, FL, USA, 8-10 April 2005; pp. 415-420.
    • (2005) Proceedings of the IEEE SoutheastCon2005 , pp. 415-420
    • Zhai, J.1    Barreto, A.B.2    Chin, C.3    Chao, L.4
  • 31
    • 79959311348 scopus 로고    scopus 로고
    • A wearable respiratory biofeedback system based on generalized body sensor network
    • Liu, G.-Z.; Huang, B.-Y.; Wang, L. A wearable respiratory biofeedback system based on generalized body sensor network. Telemed. J. E-Health 2011, 17, 348-357.
    • (2011) Telemed. J. E-Health , vol.17 , pp. 348-357
    • Liu, G.-Z.1    Huang, B.-Y.2    Wang, L.3
  • 35
    • 14844283821 scopus 로고    scopus 로고
    • The LifeShirt: A multi-function ambulatory system monitoring health, disease, and medical intervention in the real world
    • Grossman, P. The LifeShirt: a multi-function ambulatory system monitoring health, disease, and medical intervention in the real world. Stud. Health Technol. Inform. 2004, 108, 133-141.
    • (2004) Stud. Health Technol. Inform , vol.108 , pp. 133-141
    • Grossman, P.1
  • 38
    • 70449570959 scopus 로고    scopus 로고
    • A wearable ECG acquisition system with compact planar-fashionable circuit board-based shirt
    • Yoo, J.; Yan, L.; Lee, S.; Kim, H.; Yoo, H.-J. A wearable ECG acquisition system with compact planar-fashionable circuit board-based shirt. IEEE Trans. Inf. Technol. Biomed. 2009, 13, 897-902.
    • (2009) IEEE Trans. Inf. Technol. Biomed , vol.13 , pp. 897-902
    • Yoo, J.1    Yan, L.2    Lee, S.3    Kim, H.4    Yoo, H.-J.5
  • 41
    • 73549111364 scopus 로고    scopus 로고
    • Future affective technology for autism and emotion communication
    • Picard, R.W. Future affective technology for autism and emotion communication. Phil. Trans. Roy. Soc. B-Biol. Sci. 2009, 364, 3575-3584.
    • (2009) Phil. Trans. Roy. Soc. B-Biol. Sci , vol.364 , pp. 3575-3584
    • Picard, R.W.1
  • 42
    • 63349103061 scopus 로고    scopus 로고
    • Fabric-Based active electrode design and fabrication for health monitoring clothing
    • Merritt, C.R.; Nagle, H.T.; Grant, E. Fabric-Based active electrode design and fabrication for health monitoring clothing. IEEE Trans. Inf. Technol. Biomed. 2009, 13, 274-280.
    • (2009) IEEE Trans. Inf. Technol. Biomed , vol.13 , pp. 274-280
    • Merritt, C.R.1    Nagle, H.T.2    Grant, E.3
  • 43
    • 45749156844 scopus 로고    scopus 로고
    • Analog front-end enables electrical impedance spectroscopy system on-chip for biomedical applications
    • doi:10.1088/0967-3334/29/6/S23
    • Seoane, F.; Ferreira, J.; Sanchéz, J. J.; Bragós, R. Analog front-end enables electrical impedance spectroscopy system on-chip for biomedical applications. Physiol. Meas. 2008, doi:10.1088/0967-3334/29/6/S23.
    • (2008) Physiol. Meas
    • Seoane, F.1    Ferreira, J.2    Sanchéz, J.J.3    Bragós, R.4
  • 45
    • 84886430496 scopus 로고    scopus 로고
    • Textrode-enabled transthoracic electrical bioimpedance measurements. Towards wearable applications of impedance cardiography
    • under revision
    • Marquez, J.C.; Rempfler, M.; Seoane, F.; Lindecrantz, K. Textrode-enabled transthoracic electrical bioimpedance measurements. Towards wearable applications of impedance cardiography. J. Elect. Bioimpedance, under revision.
    • J. Elect. Bioimpedance
    • Marquez, J.C.1    Rempfler, M.2    Seoane, F.3    Lindecrantz, K.4
  • 46
    • 77954666264 scopus 로고    scopus 로고
    • Comparison of dry-textile electrodes for electrical bioimpedance spectroscopy measurements
    • doi:10.1088/1742-6596/224/1/012140
    • Marquez, J.C.; Seoane, F.; Välimäki, E.; Lindecrantz, K. Comparison of dry-textile electrodes for electrical bioimpedance spectroscopy measurements. J. Phys. Confer. Ser. 2010, doi:10.1088/1742-6596/224/1/012140.
    • (2010) J. Phys. Confer. Ser
    • Marquez, J.C.1    Seoane, F.2    Välimäki, E.3    Lindecrantz, K.4
  • 47
    • 84872161959 scopus 로고    scopus 로고
    • Textrode functional straps for bioimpedance measurements--experimental results for body composition analysis
    • doi:10.1038/ejcn.2012.161
    • Marquez, J.C.; Seoane, F.; Lindecrantz, K. Textrode functional straps for bioimpedance measurements--experimental results for body composition analysis. Eur. J. Clin. Nutr. 2013, doi:10.1038/ejcn.2012.161.
    • (2013) Eur. J. Clin. Nutr
    • Marquez, J.C.1    Seoane, F.2    Lindecrantz, K.3
  • 50
    • 84886384381 scopus 로고
    • European Commission, Medical Devices Council Directive 93/42/EEC, 7 December
    • European Commission, Medical Devices Council Directive 93/42/EEC. Offic. J. Eur. Union, 7 December 1993.
    • (1993) Offic. J. Eur. Union
  • 51
    • 84877349664 scopus 로고    scopus 로고
    • Studying the performance of conductive polymer films as textile electrodes for electrical bioimpedance measurements
    • doi: 10.1088/1742-6596/434/1/012027
    • Cunico, F. J.; Marquez, J. C.; Hilke, H.; Skrifvars, M.; Seoane, F. Studying the performance of conductive polymer films as textile electrodes for electrical bioimpedance measurements. J. Phys. Confer. Ser. 2013, doi: 10.1088/1742-6596/434/1/012027.
    • (2013) J. Phys. Confer. Ser
    • Cunico, F.J.1    Marquez, J.C.2    Hilke, H.3    Skrifvars, M.4    Seoane, F.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.