메뉴 건너뛰기




Volumn 71, Issue , 2014, Pages 111-120

Investigation of formaldehyde sources in French schools using a passive flux sampler

Author keywords

Emission rates; Formaldehyde; Indoor air; Mass balance model; Passive sampling; Public school

Indexed keywords

EMISSION RATES; INDOOR AIR; MASS BALANCE MODEL; PASSIVE SAMPLING; PUBLIC SCHOOLS;

EID: 84886305626     PISSN: 03601323     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.buildenv.2013.10.002     Document Type: Article
Times cited : (37)

References (42)
  • 1
    • 20444496180 scopus 로고    scopus 로고
    • Daily time spent indoors in German homes-baseline data for the assessment of indoor exposure of German occupants
    • Brasche S., Bischof W. Daily time spent indoors in German homes-baseline data for the assessment of indoor exposure of German occupants. Int J Hyg Environ Health 2005, 208:247-253.
    • (2005) Int J Hyg Environ Health , vol.208 , pp. 247-253
    • Brasche, S.1    Bischof, W.2
  • 3
    • 0006583183 scopus 로고    scopus 로고
    • U.S. EPA/Office of Air and Radiation, EPA 402-K-93-007 Office of Radiation and Indoor Air, Consumer Product Safety Commission
    • Office of Radiation and Indoor Air, Consumer Product Safety Commission The inside story: a guide to indoor air quality 2013, U.S. EPA/Office of Air and Radiation, EPA 402-K-93-007.
    • (2013) The inside story: a guide to indoor air quality
  • 4
    • 84864022094 scopus 로고    scopus 로고
    • Poor air quality in classrooms related to asthma and rhinitis in primary schoolchildren of the French 6 cities study
    • Annesi-Maesano I., Hulin M., Lavaud F., Raherison C., Kopferschmitt C., de Blay F., et al. Poor air quality in classrooms related to asthma and rhinitis in primary schoolchildren of the French 6 cities study. Thorax 2012, 67:682-688.
    • (2012) Thorax , vol.67 , pp. 682-688
    • Annesi-Maesano, I.1    Hulin, M.2    Lavaud, F.3    Raherison, C.4    Kopferschmitt, C.5    de Blay, F.6
  • 7
    • 39749201628 scopus 로고    scopus 로고
    • VOCs in industrial, urban and suburban neighborhoods, Part 1: indoor and outdoor concentrations, variation, and risk drivers
    • Jia C., Batterman S., Godwin C. VOCs in industrial, urban and suburban neighborhoods, Part 1: indoor and outdoor concentrations, variation, and risk drivers. Atmos Environ 2008, 42:2083-2100.
    • (2008) Atmos Environ , vol.42 , pp. 2083-2100
    • Jia, C.1    Batterman, S.2    Godwin, C.3
  • 8
    • 77951207316 scopus 로고    scopus 로고
    • Formaldehyde in the indoor environment
    • Salthammer T., Mentese S., Marutzky R. Formaldehyde in the indoor environment. Chem Rev 2010, 110:2536-2572.
    • (2010) Chem Rev , vol.110 , pp. 2536-2572
    • Salthammer, T.1    Mentese, S.2    Marutzky, R.3
  • 11
    • 0344120306 scopus 로고    scopus 로고
    • Acomparison of indoor air pollutants in Japan and Sweden: formaldehyde, nitrogen dioxide, and chlorinated volatile organic compounds
    • Sakai K., Norbäck D., Mi Y., Shibata E., Kamijima M., Yamada T., et al. Acomparison of indoor air pollutants in Japan and Sweden: formaldehyde, nitrogen dioxide, and chlorinated volatile organic compounds. Environ Res 2004, 94:75-85.
    • (2004) Environ Res , vol.94 , pp. 75-85
    • Sakai, K.1    Norbäck, D.2    Mi, Y.3    Shibata, E.4    Kamijima, M.5    Yamada, T.6
  • 12
    • 22844437734 scopus 로고    scopus 로고
    • Levels and determinants of formaldehyde, acetaldehyde, and acrolein in residential indoor air in Prince Edward Island, Canada
    • Gilbert N.L., Guay M., David Miller J., Judek S., Chan C.C., Dales R.E. Levels and determinants of formaldehyde, acetaldehyde, and acrolein in residential indoor air in Prince Edward Island, Canada. Environ Res 2005, 99:11-17.
    • (2005) Environ Res , vol.99 , pp. 11-17
    • Gilbert, N.L.1    Guay, M.2    David Miller, J.3    Judek, S.4    Chan, C.C.5    Dales, R.E.6
  • 14
    • 77956137456 scopus 로고
    • Documentation of field and laboratory emission cell "FLEC": identification of emission processes from carpet, linoleum, paint, and sealant by modeling
    • Wolkoff P., Clausen P.A., Nielsen P.A., Gunnarsen L. Documentation of field and laboratory emission cell "FLEC": identification of emission processes from carpet, linoleum, paint, and sealant by modeling. Indoor Air 1993, 3:291-297.
    • (1993) Indoor Air , vol.3 , pp. 291-297
    • Wolkoff, P.1    Clausen, P.A.2    Nielsen, P.A.3    Gunnarsen, L.4
  • 15
    • 0000104772 scopus 로고
    • Application of the field and laboratory emission cell "FLEC" - performance study, intercomparison study, and case study of damaged linoleum in an office
    • Wolkoff P., Clausen P.A., Nielsen P.A. Application of the field and laboratory emission cell "FLEC" - performance study, intercomparison study, and case study of damaged linoleum in an office. Indoor Air 1995, 5:196-203.
    • (1995) Indoor Air , vol.5 , pp. 196-203
    • Wolkoff, P.1    Clausen, P.A.2    Nielsen, P.A.3
  • 16
    • 0032006157 scopus 로고    scopus 로고
    • Characterization of the field and laboratory emission cell-FLEC: flow field and air velocities
    • Uhde E., Borgschulte A., Salthammer T. Characterization of the field and laboratory emission cell-FLEC: flow field and air velocities. Atmos Environ 1998, 32:773-781.
    • (1998) Atmos Environ , vol.32 , pp. 773-781
    • Uhde, E.1    Borgschulte, A.2    Salthammer, T.3
  • 17
    • 0033256194 scopus 로고    scopus 로고
    • Determination of formaldehyde emission with field and laboratory emission cell (FLEC) - recovery and correlation to the chamber method
    • Risholm-Sundman M. Determination of formaldehyde emission with field and laboratory emission cell (FLEC) - recovery and correlation to the chamber method. Indoor Air 1999, 9:268-272.
    • (1999) Indoor Air , vol.9 , pp. 268-272
    • Risholm-Sundman, M.1
  • 18
    • 0033190735 scopus 로고    scopus 로고
    • Materials emission of chemicals - PVC Flooring materials
    • Lundgren B., Jonsson B., Ek-Olausson B. Materials emission of chemicals - PVC Flooring materials. Indoor Air 1999, 9:202-208.
    • (1999) Indoor Air , vol.9 , pp. 202-208
    • Lundgren, B.1    Jonsson, B.2    Ek-Olausson, B.3
  • 19
    • 0038792343 scopus 로고    scopus 로고
    • Effects of substrate parameters on the emissions of volatile organic compounds from wet coating materials
    • Zhang L.Z., Niu J.L. Effects of substrate parameters on the emissions of volatile organic compounds from wet coating materials. Build Environ 2003, 38:939-946.
    • (2003) Build Environ , vol.38 , pp. 939-946
    • Zhang, L.Z.1    Niu, J.L.2
  • 20
    • 13444311793 scopus 로고    scopus 로고
    • VOC and SVOC emissions from adhesives, floor coverings and complete floor structures
    • Wilke O., Jann O., Brodner D. VOC and SVOC emissions from adhesives, floor coverings and complete floor structures. Indoor Air 2004, 14:98-107.
    • (2004) Indoor Air , vol.14 , pp. 98-107
    • Wilke, O.1    Jann, O.2    Brodner, D.3
  • 21
    • 33847141088 scopus 로고    scopus 로고
    • Reference values for structure emissions measured on site in new residential buildings in Finland
    • Jarnstrom H., Saarela K., Kalliokoski P., Pasanen A. Reference values for structure emissions measured on site in new residential buildings in Finland. Atmos Environ 2007, 41:2290-2302.
    • (2007) Atmos Environ , vol.41 , pp. 2290-2302
    • Jarnstrom, H.1    Saarela, K.2    Kalliokoski, P.3    Pasanen, A.4
  • 22
    • 84856564191 scopus 로고    scopus 로고
    • Testing and sampling devices for monitoring volatile and semi-volatile organic compounds in indoor air
    • Marć M., Zabiegała B., Namieśnik J. Testing and sampling devices for monitoring volatile and semi-volatile organic compounds in indoor air. Trends Anal Chem 2012, 32:76-86.
    • (2012) Trends Anal Chem , vol.32 , pp. 76-86
    • Marć, M.1    Zabiegała, B.2    Namieśnik, J.3
  • 23
    • 78650318937 scopus 로고    scopus 로고
    • Validation of a passive flux sampler for on-site measurement of formaldehyde emission rates from building and furnishing materials
    • Blondel A., Plaisance H. Validation of a passive flux sampler for on-site measurement of formaldehyde emission rates from building and furnishing materials. Anal Method 2010, 2:2032.
    • (2010) Anal Method , vol.2 , pp. 2032
    • Blondel, A.1    Plaisance, H.2
  • 24
    • 34247854938 scopus 로고    scopus 로고
    • Passive flux sampler for measurement of formaldehyde emission rates
    • Shinohara N., Fujii M., Yamasaki A., Yanagisawa Y. Passive flux sampler for measurement of formaldehyde emission rates. Atmos Environ 2007, 41:4018-4028.
    • (2007) Atmos Environ , vol.41 , pp. 4018-4028
    • Shinohara, N.1    Fujii, M.2    Yamasaki, A.3    Yanagisawa, Y.4
  • 25
    • 45249107056 scopus 로고    scopus 로고
    • Passive emission colorimetric sensor (PECS) for measuring emission rates of formaldehyde based on an enzymatic reaction and reflectance photometry
    • Shinohara N., Kajiwara T., Ohnishi M., Kodama K., Yanagisawa Y. Passive emission colorimetric sensor (PECS) for measuring emission rates of formaldehyde based on an enzymatic reaction and reflectance photometry. Environ Sci Technol 2008, 42:4472-4477.
    • (2008) Environ Sci Technol , vol.42 , pp. 4472-4477
    • Shinohara, N.1    Kajiwara, T.2    Ohnishi, M.3    Kodama, K.4    Yanagisawa, Y.5
  • 26
    • 58749116821 scopus 로고    scopus 로고
    • On-site passive flux sampler measurement of emission rates of carbonyls and VOCs from multiple indoor sources
    • Shinohara N., Kai Y., Mizukoshi A., Fujii M., Kumagai K., Okuizumi Y., et al. On-site passive flux sampler measurement of emission rates of carbonyls and VOCs from multiple indoor sources. Build Environ 2009, 44:859-863.
    • (2009) Build Environ , vol.44 , pp. 859-863
    • Shinohara, N.1    Kai, Y.2    Mizukoshi, A.3    Fujii, M.4    Kumagai, K.5    Okuizumi, Y.6
  • 27
    • 0345293326 scopus 로고    scopus 로고
    • Astudy on emission of phthalate esters from plastic materials using a passive flux sampler
    • Fujii M., Shinohara N., Lim A., Otake T., Kumagai K., Yanagisawa Y. Astudy on emission of phthalate esters from plastic materials using a passive flux sampler. Atmos Environ 2003, 37:5495-5504.
    • (2003) Atmos Environ , vol.37 , pp. 5495-5504
    • Fujii, M.1    Shinohara, N.2    Lim, A.3    Otake, T.4    Kumagai, K.5    Yanagisawa, Y.6
  • 28
    • 79551621851 scopus 로고    scopus 로고
    • Screening of formaldehyde indoor sources and quantification of their emission using a passive sampler
    • Blondel A., Plaisance H. Screening of formaldehyde indoor sources and quantification of their emission using a passive sampler. Build Environ 2011, 46:1284-1291.
    • (2011) Build Environ , vol.46 , pp. 1284-1291
    • Blondel, A.1    Plaisance, H.2
  • 29
    • 80054850966 scopus 로고    scopus 로고
    • Campagne pilote de surveillance de la qualité de l'air dans les écoles et crèches en France: Résultats de la première phase
    • Michelot N., Mandin C., Ramalho O., Riberon J., Marchand C., Malherbe L., et al. Campagne pilote de surveillance de la qualité de l'air dans les écoles et crèches en France: Résultats de la première phase. Pollut Atmos 2011, 267-279.
    • (2011) Pollut Atmos , pp. 267-279
    • Michelot, N.1    Mandin, C.2    Ramalho, O.3    Riberon, J.4    Marchand, C.5    Malherbe, L.6
  • 33
    • 0026909738 scopus 로고
    • Apportionment of residential indoor aerosol, voc and aldehyde species to indoor and outdoor sources, and their source strengths
    • Lewis C.W., Zweidinger R.B. Apportionment of residential indoor aerosol, voc and aldehyde species to indoor and outdoor sources, and their source strengths. Atmos Environ Part A General Topics 1992, 26:2179-2184.
    • (1992) Atmos Environ Part A General Topics , vol.26 , pp. 2179-2184
    • Lewis, C.W.1    Zweidinger, R.B.2
  • 34
    • 32844459974 scopus 로고    scopus 로고
    • Estimating contributions of indoor and outdoor sources to indoor carbonyl concentrations in three urban areas of the United States
    • Liu W., Zhang J., Zhang L., Turpin B., Weisel C., Morandi M., et al. Estimating contributions of indoor and outdoor sources to indoor carbonyl concentrations in three urban areas of the United States. Atmos Environ 2006, 40:2202-2214.
    • (2006) Atmos Environ , vol.40 , pp. 2202-2214
    • Liu, W.1    Zhang, J.2    Zhang, L.3    Turpin, B.4    Weisel, C.5    Morandi, M.6
  • 35
    • 0001770110 scopus 로고    scopus 로고
    • Urea-formaldehyde (UF) adhesive resins for wood
    • Dunky M. Urea-formaldehyde (UF) adhesive resins for wood. Int J Adhesion Adhesives 1998, 18:95-107.
    • (1998) Int J Adhesion Adhesives , vol.18 , pp. 95-107
    • Dunky, M.1
  • 36
    • 0033192489 scopus 로고    scopus 로고
    • Chamber assessment of formaldehyde and VOC emissions from wood-based Panels
    • Brown S.K. Chamber assessment of formaldehyde and VOC emissions from wood-based Panels. Indoor Air 1999, 9:209-215.
    • (1999) Indoor Air , vol.9 , pp. 209-215
    • Brown, S.K.1
  • 37
    • 19244372373 scopus 로고    scopus 로고
    • Concentrations and decay rates of ozone in indoor air in dependence on building and surface materials
    • Moriske H.J., Ebert G., Konieczny L., Menk G., Schöndube M. Concentrations and decay rates of ozone in indoor air in dependence on building and surface materials. Toxicol Lett 1998, 96-97:319-323.
    • (1998) Toxicol Lett , pp. 319-323
    • Moriske, H.J.1    Ebert, G.2    Konieczny, L.3    Menk, G.4    Schöndube, M.5
  • 38
    • 0029716395 scopus 로고    scopus 로고
    • Indoor humidity and human health-part I: literature review of health effects of humidity-influenced indoor pollutants
    • Baughman A., Arens E. Indoor humidity and human health-part I: literature review of health effects of humidity-influenced indoor pollutants. ASHRAE Trans 1996, 102:193-211.
    • (1996) ASHRAE Trans , vol.102 , pp. 193-211
    • Baughman, A.1    Arens, E.2
  • 39
    • 0019918602 scopus 로고
    • Technique for determining pollutant emissions from a gas-fired range
    • Traynor G.W., Anthon D.W., Hollowell C.D. Technique for determining pollutant emissions from a gas-fired range. Atmos Environ 1982, 16:2979-2987.
    • (1982) Atmos Environ , vol.16 , pp. 2979-2987
    • Traynor, G.W.1    Anthon, D.W.2    Hollowell, C.D.3
  • 41
    • 0022779530 scopus 로고
    • Mathematical modeling of chemically reactive pollutants in indoor air
    • Nazaroff W.W., Cass G.R. Mathematical modeling of chemically reactive pollutants in indoor air. Environ Sci Technol 1986, 20:924-934.
    • (1986) Environ Sci Technol , vol.20 , pp. 924-934
    • Nazaroff, W.W.1    Cass, G.R.2