메뉴 건너뛰기




Volumn 28, Issue 4, 2013, Pages 4320-4327

The effect of wind power integration on the frequency of tap changes of a substation transformer

Author keywords

Load flow analysis; Power transformers; Reactive power; Tap changer; Wind power

Indexed keywords

CHANGE OPERATIONS; LOAD FLOW ANALYSIS; RADIAL DISTRIBUTION SYSTEMS; SUBSTATION TRANSFORMERS; TAP CHANGERS; WEAR AND TEAR; WIND POWER INTEGRATIONS; WIND POWER PENETRATION;

EID: 84886097703     PISSN: 08858950     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPWRS.2013.2266260     Document Type: Article
Times cited : (16)

References (21)
  • 1
    • 0036880503 scopus 로고    scopus 로고
    • Review of condition assessment of power transformers in service
    • Dec.
    • M. Wang, A. Vandermaar, and K. Srivastava, "Review of condition assessment of power transformers in service," IEEE Elect. Insul. Mag., vol. 18, no. 6, pp. 12-25, Dec. 2002.
    • (2002) IEEE Elect. Insul. Mag. , vol.18 , Issue.6 , pp. 12-25
    • Wang, M.1    Vandermaar, A.2    Srivastava, K.3
  • 5
    • 0020753767 scopus 로고
    • An international survey on failures in large power transformers in service
    • C. W. G. 05
    • C. W. G. 05, "An international survey on failures in large power transformers in service," Electra, no. 88, pp. 21-47, 1983.
    • (1983) Electra , Issue.88 , pp. 21-47
  • 12
    • 0037250820 scopus 로고    scopus 로고
    • Condition assessment of power transformer onload tap changers using wavelet analysis and self-organizing map: Field evaluation
    • Jan.
    • P. Kang and D. Birtwhistle, "Condition assessment of power transformer onload tap changers using wavelet analysis and self-organizing map: Field evaluation," IEEE Trans. Power Del., vol. 18, no. 1, pp. 78-84, Jan. 2003.
    • (2003) IEEE Trans. Power Del. , vol.18 , Issue.1 , pp. 78-84
    • Kang, P.1    Birtwhistle, D.2
  • 15
    • 43849092280 scopus 로고    scopus 로고
    • Distributed reactive power generation control for voltage rise mitigation in distribution networks
    • May
    • P. Carvalho, P. Correia, and L. Ferreira, "Distributed reactive power generation control for voltage rise mitigation in distribution networks," IEEE Trans. Power Syst., vol. 23, no. 2, pp. 766-772, May 2008.
    • (2008) IEEE Trans. Power Syst. , vol.23 , Issue.2 , pp. 766-772
    • Carvalho, P.1    Correia, P.2    Ferreira, L.3
  • 19
    • 29144523061 scopus 로고    scopus 로고
    • On the implementation of an interior-point filter line-search algorithm for large-scale nonlinear programming
    • A. Wächter and L. T. Biegler, "On the implementation of an interior-point filter line-search algorithm for large-scale nonlinear programming," Math. Program., vol. 106, pp. 25-57, 2006.
    • (2006) Math. Program. , vol.106 , pp. 25-57
    • Wächter, A.1    Biegler, L.T.2
  • 21
    • 67349088743 scopus 로고    scopus 로고
    • Wind power interconnection into the power system: A review of grid code requirements
    • B. Singh and S. Singh, "Wind power interconnection into the power system: A review of grid code requirements," Electricity J., vol. 22, no. 5, pp. 54-63, 2009.
    • (2009) Electricity J. , vol.22 , Issue.5 , pp. 54-63
    • Singh, B.1    Singh, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.