메뉴 건너뛰기




Volumn 12, Issue 1, 2013, Pages

Porous media properties of reticulated shape memory polymer foams and mock embolic coils for aneurysm treatment

Author keywords

Aneurysm treatment; Embolic coils; FHDD, Forchheimer Hazen Dupuit Darcy equation; Form factor; Permeability; SMP, Shape memory polymer foams

Indexed keywords

APPROXIMATION THEORY; LAMINAR FLOW; MECHANICAL PERMEABILITY; POLYMERS; POROUS MATERIALS; REYNOLDS NUMBER;

EID: 84886028526     PISSN: None     EISSN: 1475925X     Source Type: Journal    
DOI: 10.1186/1475-925X-12-103     Document Type: Article
Times cited : (21)

References (45)
  • 1
    • 60549117479 scopus 로고    scopus 로고
    • Intracranial aneurysm enlargement on serial magnetic resonance angiography frequency and risk factors
    • 10.1161/STROKEAHA.108.519165, 19023101
    • Burns JD, Huston J, Layton KF, Piepgras DG, Brown RD. Intracranial aneurysm enlargement on serial magnetic resonance angiography frequency and risk factors. Stroke 2009, 40:406-411. 10.1161/STROKEAHA.108.519165, 19023101.
    • (2009) Stroke , vol.40 , pp. 406-411
    • Burns, J.D.1    Huston, J.2    Layton, K.F.3    Piepgras, D.G.4    Brown, R.D.5
  • 3
    • 64149121358 scopus 로고    scopus 로고
    • Quality of life after stroke: the importance of a good recovery
    • Carod-Artal FJ, Egido JA. Quality of life after stroke: the importance of a good recovery. Cerebrovasc Dis 2009, 27:204-214.
    • (2009) Cerebrovasc Dis , vol.27 , pp. 204-214
    • Carod-Artal, F.J.1    Egido, J.A.2
  • 6
    • 0024404240 scopus 로고
    • Risk factors in intracranial saccular aneurysms. Aspects on the formation and rupture of aneurysms, and development of cerebral vasospasm
    • Østergaard JR. Risk factors in intracranial saccular aneurysms. Aspects on the formation and rupture of aneurysms, and development of cerebral vasospasm. Acta Neurol Scand 1989, 80:81-98.
    • (1989) Acta Neurol Scand , vol.80 , pp. 81-98
    • Østergaard, J.R.1
  • 7
    • 0031027274 scopus 로고    scopus 로고
    • Intracranial aneurysms
    • 10.1056/NEJM199701023360106, 8970938
    • Schievink WI. Intracranial aneurysms. New Engl J Med 1997, 336:28-40. 10.1056/NEJM199701023360106, 8970938.
    • (1997) New Engl J Med , vol.336 , pp. 28-40
    • Schievink, W.I.1
  • 8
    • 39049193854 scopus 로고    scopus 로고
    • History of endovascular surgery: personal accounts of the evolution
    • S3-30-S3-38
    • Richling B. History of endovascular surgery: personal accounts of the evolution. Neurosurgery 2006, 59:S3-30-S3-38.
    • (2006) Neurosurgery , vol.59
    • Richling, B.1
  • 10
    • 33750359248 scopus 로고    scopus 로고
    • Historical perspectives: the microsurgical and endovascular treatment of aneurysms
    • S3-39-S3-47
    • Prestigiacomo CJ. Historical perspectives: the microsurgical and endovascular treatment of aneurysms. Neurosurgery 2006, 59:S3-39-S3-47.
    • (2006) Neurosurgery , vol.59
    • Prestigiacomo, C.J.1
  • 11
    • 1842296356 scopus 로고    scopus 로고
    • Guglielmi detachable coil embolization of acute intracranial aneurysm: perioperative anatomical and clinical outcome in 403 patients
    • 10.3171/jns.1997.86.3.0475, 9046305
    • Viñuela F, Duckwiler G, Mawad M. Guglielmi detachable coil embolization of acute intracranial aneurysm: perioperative anatomical and clinical outcome in 403 patients. J Neurosurg 1997, 86:475-482. 10.3171/jns.1997.86.3.0475, 9046305.
    • (1997) J Neurosurg , vol.86 , pp. 475-482
    • Viñuela, F.1    Duckwiler, G.2    Mawad, M.3
  • 12
    • 0028283928 scopus 로고
    • Endovascular occlusion of intracranial aneurysms with electrically detachable coils: correlation of aneurysm neck size and treatment results
    • Zubillaga AF, Guglielmi G, Vi F, Duckwiler G. Endovascular occlusion of intracranial aneurysms with electrically detachable coils: correlation of aneurysm neck size and treatment results. Am J Neuroradiol 1994, 15:815-820.
    • (1994) Am J Neuroradiol , vol.15 , pp. 815-820
    • Zubillaga, A.F.1    Guglielmi, G.2    Vi, F.3    Duckwiler, G.4
  • 13
    • 0033517752 scopus 로고    scopus 로고
    • Detachable coils to treat intracranial aneurysms
    • Willinsky RA. Detachable coils to treat intracranial aneurysms. Can Med Assoc J 1999, 161:1136-1136.
    • (1999) Can Med Assoc J , vol.161 , pp. 1136-1136
    • Willinsky, R.A.1
  • 14
    • 2442640381 scopus 로고    scopus 로고
    • Relation between aneurysm volume, packing, and compaction in 145 cerebral aneurysms treated with coils
    • 10.1148/radiol.2313030460, 15118115
    • Sluzewski M, van Rooij WJ, Slob MJ, Bescós JO, Slump CH, Wijnalda D. Relation between aneurysm volume, packing, and compaction in 145 cerebral aneurysms treated with coils. Radiology 2004, 231:653-658. 10.1148/radiol.2313030460, 15118115.
    • (2004) Radiology , vol.231 , pp. 653-658
    • Sluzewski, M.1    van Rooij, W.J.2    Slob, M.J.3    Bescós, J.O.4    Slump, C.H.5    Wijnalda, D.6
  • 15
    • 77953053527 scopus 로고    scopus 로고
    • Biomedical applications of thermally activated shape memory polymers
    • 10.1039/b923717h, 3023912, 21258605
    • Ward Small I, Singhal P, Wilson TS, Maitland DJ. Biomedical applications of thermally activated shape memory polymers. J Mater Chem 2010, 20:3356-3366. 10.1039/b923717h, 3023912, 21258605.
    • (2010) J Mater Chem , vol.20 , pp. 3356-3366
    • Ward Small, I.1    Singhal, P.2    Wilson, T.S.3    Maitland, D.J.4
  • 18
    • 79961054154 scopus 로고    scopus 로고
    • The effect of moisture absorption on the physical properties of polyurethane shape memory polymer foams
    • 085010
    • Yu YJ, Hearon K, Wilson TS, Maitland DJ. The effect of moisture absorption on the physical properties of polyurethane shape memory polymer foams. Smart Mater Struct 2011, 20:1-6. 085010.
    • (2011) Smart Mater Struct , vol.20 , pp. 1-6
    • Yu, Y.J.1    Hearon, K.2    Wilson, T.S.3    Maitland, D.J.4
  • 19
    • 84862131423 scopus 로고    scopus 로고
    • Opacification of shape memory polymer foam designed for treatment of intracranial aneurysms
    • 10.1007/s10439-011-0468-1, 3311707, 22101759
    • Rodriguez JN, Yu YJ, Miller MW, Wilson TS, Hartman J, Clubb FJ, Gentry B, Maitland DJ. Opacification of shape memory polymer foam designed for treatment of intracranial aneurysms. Ann Biomed Eng 2012, 40:883-897. 10.1007/s10439-011-0468-1, 3311707, 22101759.
    • (2012) Ann Biomed Eng , vol.40 , pp. 883-897
    • Rodriguez, J.N.1    Yu, Y.J.2    Miller, M.W.3    Wilson, T.S.4    Hartman, J.5    Clubb, F.J.6    Gentry, B.7    Maitland, D.J.8
  • 20
    • 35448943592 scopus 로고    scopus 로고
    • Vascular dynamics of a shape memory polymer foam aneurysm treatment technique
    • 10.1007/s10439-007-9358-y, 17676399
    • Ortega J, Maitland D, Wilson T, Tsai W, Savaş T, Saloner D. Vascular dynamics of a shape memory polymer foam aneurysm treatment technique. Ann Biomed Eng 2007, 35:1870-1884. 10.1007/s10439-007-9358-y, 17676399.
    • (2007) Ann Biomed Eng , vol.35 , pp. 1870-1884
    • Ortega, J.1    Maitland, D.2    Wilson, T.3    Tsai, W.4    Savaş, T.5    Saloner, D.6
  • 22
    • 79953689909 scopus 로고    scopus 로고
    • Post-polymerization crosslinked polyurethane shape memory polymers
    • 10.1002/app.33428, 3092441, 21572577
    • Hearon K, Gall K, Ware T, Maitland DJ, Bearinger JP, Wilson TS. Post-polymerization crosslinked polyurethane shape memory polymers. J Appl Polym Sci 2011, 121:144-153. 10.1002/app.33428, 3092441, 21572577.
    • (2011) J Appl Polym Sci , vol.121 , pp. 144-153
    • Hearon, K.1    Gall, K.2    Ware, T.3    Maitland, D.J.4    Bearinger, J.P.5    Wilson, T.S.6
  • 23
    • 44449176037 scopus 로고    scopus 로고
    • The haemodynamics of endovascular aneurysm treatment: a computational modelling approach for estimating the influence of multiple coil deployment
    • Kakalis NMP, Mitsos AP, Byrne JV, Ventikos Y. The haemodynamics of endovascular aneurysm treatment: a computational modelling approach for estimating the influence of multiple coil deployment. IEEE T Med Imaging 2008, 27:814-824.
    • (2008) IEEE T Med Imaging , vol.27 , pp. 814-824
    • Kakalis, N.M.P.1    Mitsos, A.P.2    Byrne, J.V.3    Ventikos, Y.4
  • 24
    • 84886080281 scopus 로고    scopus 로고
    • Using porous media theory to determine the coil volume needed to arrest flow in brain aneurysms
    • Bosa Roca: Taylor & Francis, Vafai K
    • Khanafer KM, Berguer R. Using porous media theory to determine the coil volume needed to arrest flow in brain aneurysms. Porous media: applications in biological systems and biotechnology 2010, 237-250. Bosa Roca: Taylor & Francis, Vafai K.
    • (2010) Porous media: applications in biological systems and biotechnology , pp. 237-250
    • Khanafer, K.M.1    Berguer, R.2
  • 25
    • 84882257268 scopus 로고    scopus 로고
    • Toward real-time simulation of blood-coil interaction during aneurysm embolization
    • Wei Y, Cotin S, Fang L, Allard J, Pan C, Ma S. Toward real-time simulation of blood-coil interaction during aneurysm embolization. Lect Notes Comput Sc 2009, 12:198-205.
    • (2009) Lect Notes Comput Sc , vol.12 , pp. 198-205
    • Wei, Y.1    Cotin, S.2    Fang, L.3    Allard, J.4    Pan, C.5    Ma, S.6
  • 26
    • 41149156492 scopus 로고    scopus 로고
    • Haemodynamic simulation of aneurysm coiling in an anatomically accurate computational fluid dynamics model: technical note
    • 10.1007/s00234-007-0334-x, 18043912
    • Mitsos AP, Kakalis NMP, Ventikos YP, Byrne JV. Haemodynamic simulation of aneurysm coiling in an anatomically accurate computational fluid dynamics model: technical note. Neuroradiology 2008, 50:341-347. 10.1007/s00234-007-0334-x, 18043912.
    • (2008) Neuroradiology , vol.50 , pp. 341-347
    • Mitsos, A.P.1    Kakalis, N.M.P.2    Ventikos, Y.P.3    Byrne, J.V.4
  • 27
    • 84876478505 scopus 로고    scopus 로고
    • Virtual treatment of basilar aneurysms using shape memory polymer foam
    • 10.1007/s10439-012-0719-9, 23329002
    • Ortega JM, Hartman J, Rodriguez JN, Maitland DJ. Virtual treatment of basilar aneurysms using shape memory polymer foam. Ann Biomed Eng 2013, 41:725-743. 10.1007/s10439-012-0719-9, 23329002.
    • (2013) Ann Biomed Eng , vol.41 , pp. 725-743
    • Ortega, J.M.1    Hartman, J.2    Rodriguez, J.N.3    Maitland, D.J.4
  • 28
    • 0002480352 scopus 로고    scopus 로고
    • The fundamental theory of flow through permeable media from Darcy to turbulence
    • Oxford: Elsevier Science, Ingham DB, Pop I
    • Lage J. The fundamental theory of flow through permeable media from Darcy to turbulence. Transport phenomena in porous media 1998, 1-30. Oxford: Elsevier Science, Ingham DB, Pop I.
    • (1998) Transport phenomena in porous media , pp. 1-30
    • Lage, J.1
  • 29
    • 0002479981 scopus 로고
    • A new look at porous media fluid mechanics-Darcy to turbulent
    • Dordrecht: Springer Netherlands, Bear J, Corapcioglu MY
    • Dybbs A, Edwards R. A new look at porous media fluid mechanics-Darcy to turbulent. Fundamentals of transport phenomena in porous media 1984, 201-256. Dordrecht: Springer Netherlands, Bear J, Corapcioglu MY.
    • (1984) Fundamentals of transport phenomena in porous media , pp. 201-256
    • Dybbs, A.1    Edwards, R.2
  • 31
    • 13444269047 scopus 로고    scopus 로고
    • Permeability of open-pore microcellular materials
    • Despois JF, Mortensen A. Permeability of open-pore microcellular materials. Acta Mater 2005, 53:1381-1388.
    • (2005) Acta Mater , vol.53 , pp. 1381-1388
    • Despois, J.F.1    Mortensen, A.2
  • 34
    • 0000744087 scopus 로고
    • Nonlinear flow in porous media
    • Ahmed N, Sunada DK. Nonlinear flow in porous media. J Hyrd Eng Div-ASCE 1969, 95:1847-1857.
    • (1969) J Hyrd Eng Div-ASCE , vol.95 , pp. 1847-1857
    • Ahmed, N.1    Sunada, D.K.2
  • 35
    • 0016114558 scopus 로고
    • Estimating the coefficient of inertial resistance in fluid flow through porous media
    • Geertsma J. Estimating the coefficient of inertial resistance in fluid flow through porous media. SPE J 1974, 14:445-450.
    • (1974) SPE J , vol.14 , pp. 445-450
    • Geertsma, J.1
  • 37
    • 3042793213 scopus 로고    scopus 로고
    • Dynamics of blood flow and platelet transport in pathological vessels
    • 10.1196/annals.1302.031, 15201174
    • Einav S, Bluestein D. Dynamics of blood flow and platelet transport in pathological vessels. Ann NY Acad Sci 2004, 1015:351-366. 10.1196/annals.1302.031, 15201174.
    • (2004) Ann NY Acad Sci , vol.1015 , pp. 351-366
    • Einav, S.1    Bluestein, D.2
  • 38
    • 84861092780 scopus 로고    scopus 로고
    • Estimation of aneurysm wall stresses created by treatment with a shape memory polymer foam device
    • 10.1007/s10237-011-0345-8, 3335983, 21901546
    • Hwang W, Volk BL, Akberali F, Singhal P, Criscione JC, Maitland DJ. Estimation of aneurysm wall stresses created by treatment with a shape memory polymer foam device. Biomech Model Mechanobiol 2012, 11:715-729. 10.1007/s10237-011-0345-8, 3335983, 21901546.
    • (2012) Biomech Model Mechanobiol , vol.11 , pp. 715-729
    • Hwang, W.1    Volk, B.L.2    Akberali, F.3    Singhal, P.4    Criscione, J.C.5    Maitland, D.J.6
  • 39
    • 0019068569 scopus 로고
    • Hydraulic permeability of open-cell hydrophilic polyurethane foams
    • Sefton MV, Lusher HM. Hydraulic permeability of open-cell hydrophilic polyurethane foams. J Appl Polym Sci 1980, 25:2167-2178.
    • (1980) J Appl Polym Sci , vol.25 , pp. 2167-2178
    • Sefton, M.V.1    Lusher, H.M.2
  • 40
    • 85024580778 scopus 로고
    • Non-Darcy flow through fibrous porous media
    • Beavers GS, Sparrow EM. Non-Darcy flow through fibrous porous media. J Appl Mech 1969, 36:711-714.
    • (1969) J Appl Mech , vol.36 , pp. 711-714
    • Beavers, G.S.1    Sparrow, E.M.2
  • 41
    • 0030361794 scopus 로고    scopus 로고
    • Pressure drops of non-Newtonian purely viscous fluid flow through synthetic foams
    • Sabiri N, Montillet A, Comiti J. Pressure drops of non-Newtonian purely viscous fluid flow through synthetic foams. Chem Eng Commun 1997, 156:59-74.
    • (1997) Chem Eng Commun , vol.156 , pp. 59-74
    • Sabiri, N.1    Montillet, A.2    Comiti, J.3
  • 42
    • 0348172166 scopus 로고    scopus 로고
    • About the use of fibrous materials in compact heat exchangers
    • Tadrist L, Miscevic M, Rahli O, Topin F. About the use of fibrous materials in compact heat exchangers. Exp Therm Fluid Sci 2004, 28:193-199.
    • (2004) Exp Therm Fluid Sci , vol.28 , pp. 193-199
    • Tadrist, L.1    Miscevic, M.2    Rahli, O.3    Topin, F.4
  • 43
    • 33947650529 scopus 로고    scopus 로고
    • Permeability of open-cell foams under compressive strain
    • Dawson M, Germaine J, Gibson L. Permeability of open-cell foams under compressive strain. Int J Solids Struct 2007, 44:5133-5145.
    • (2007) Int J Solids Struct , vol.44 , pp. 5133-5145
    • Dawson, M.1    Germaine, J.2    Gibson, L.3
  • 44
    • 1842471932 scopus 로고    scopus 로고
    • Non-Newtonian blood flow in human right coronary arteries: steady state simulations
    • 10.1016/j.jbiomech.2003.09.016, 15047000
    • Johnston BM, Johnston PR, Corney S, Kilpatrick D. Non-Newtonian blood flow in human right coronary arteries: steady state simulations. J Biomech 2004, 37:709-720. 10.1016/j.jbiomech.2003.09.016, 15047000.
    • (2004) J Biomech , vol.37 , pp. 709-720
    • Johnston, B.M.1    Johnston, P.R.2    Corney, S.3    Kilpatrick, D.4
  • 45
    • 2942670789 scopus 로고    scopus 로고
    • Hemodynamic versus hydrodynamic effects of guglielmi detachable coils on intra-aneurysmal pressure and flow at varying pulse rate and systemic pressure
    • Sorteberg A, Sorteberg W, Aagaard BDL, Rappe A, Strother CM. Hemodynamic versus hydrodynamic effects of guglielmi detachable coils on intra-aneurysmal pressure and flow at varying pulse rate and systemic pressure. Am J Neuroradiol 2004, 25:1049-1057.
    • (2004) Am J Neuroradiol , vol.25 , pp. 1049-1057
    • Sorteberg, A.1    Sorteberg, W.2    Aagaard, B.D.L.3    Rappe, A.4    Strother, C.M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.