-
1
-
-
0036703563
-
Evaluation of Kodak EDR2 film for dose verification of intensity modulated radiation therapy delivered by a static multileaf collimator
-
Zhu X.R., Jursinic P.A., Grimm D.F., Lopez F., Rownd J.J., Gillin M.T. Evaluation of Kodak EDR2 film for dose verification of intensity modulated radiation therapy delivered by a static multileaf collimator. Med Phys 2002, 29(8):1687-1692.
-
(2002)
Med Phys
, vol.29
, Issue.8
, pp. 1687-1692
-
-
Zhu, X.R.1
Jursinic, P.A.2
Grimm, D.F.3
Lopez, F.4
Rownd, J.J.5
Gillin, M.T.6
-
2
-
-
0032521249
-
Dosimetric verification of the dynamic intensity-modulated radiation therapy of 92 patients
-
Tsai J.-S., Wazer D.E., Ling M.N., Wu J.K., Fagundes M., DiPetrillo T., et al. Dosimetric verification of the dynamic intensity-modulated radiation therapy of 92 patients. Int J Radiat Oncol Biol Phys 1998, 40:1213-1230.
-
(1998)
Int J Radiat Oncol Biol Phys
, vol.40
, pp. 1213-1230
-
-
Tsai, J.-S.1
Wazer, D.E.2
Ling, M.N.3
Wu, J.K.4
Fagundes, M.5
DiPetrillo, T.6
-
3
-
-
0032911422
-
Dosimetric verification of a commercial inverse treatment planning system
-
Xing L., Curran B., Hill R., Holmes T., Ma L., Forster K.M., et al. Dosimetric verification of a commercial inverse treatment planning system. Phys Med Biol 1999, 44:463-478.
-
(1999)
Phys Med Biol
, vol.44
, pp. 463-478
-
-
Xing, L.1
Curran, B.2
Hill, R.3
Holmes, T.4
Ma, L.5
Forster, K.M.6
-
4
-
-
14644419015
-
Dosimetric accuracy of Kodak EDR2 film for IMRT verifications
-
Childress N.L., Salehpour M., Dong L., Bloch C., White R.A., Rosen I.I. Dosimetric accuracy of Kodak EDR2 film for IMRT verifications. Med Phys 2005, 32(2):539-548.
-
(2005)
Med Phys
, vol.32
, Issue.2
, pp. 539-548
-
-
Childress, N.L.1
Salehpour, M.2
Dong, L.3
Bloch, C.4
White, R.A.5
Rosen, I.I.6
-
5
-
-
34447328764
-
TG-69: radiographic film for megavoltage beam dosimetry
-
Pai S., Das I.J., Dempsey J.F., Lam K.L., LoSasso T.J., Olch A.J., et al. TG-69: radiographic film for megavoltage beam dosimetry. Med Phys 2007, 34(6):2228-2258.
-
(2007)
Med Phys
, vol.34
, Issue.6
, pp. 2228-2258
-
-
Pai, S.1
Das, I.J.2
Dempsey, J.F.3
Lam, K.L.4
LoSasso, T.J.5
Olch, A.J.6
-
6
-
-
33750544711
-
Clinical use of EBT model Gafchromic film in radiotherapy
-
Fiandra C., Ricardi U., Ragona R., Anglesio S., Giglioli F.R., Calamia E., et al. Clinical use of EBT model Gafchromic film in radiotherapy. Med Phys 2006, 33:4314-4319.
-
(2006)
Med Phys
, vol.33
, pp. 4314-4319
-
-
Fiandra, C.1
Ricardi, U.2
Ragona, R.3
Anglesio, S.4
Giglioli, F.R.5
Calamia, E.6
-
7
-
-
56749104794
-
Absolute and relative dose measurements with Gafchromic™ EBT film for high energy electron beams with different doses per pulse
-
Fiandra C., Ragona R., Ricardi U., Anglesio S., Giglioli F.R. Absolute and relative dose measurements with Gafchromic™ EBT film for high energy electron beams with different doses per pulse. Med Phys 2008, 35:5463-5470.
-
(2008)
Med Phys
, vol.35
, pp. 5463-5470
-
-
Fiandra, C.1
Ragona, R.2
Ricardi, U.3
Anglesio, S.4
Giglioli, F.R.5
-
9
-
-
27644471150
-
Weak energy dependence of EBT Gafchromic film dose response in the 50kVp-10MVp x-ray range
-
Butson M.J., Cheung T., Yu P.K. Weak energy dependence of EBT Gafchromic film dose response in the 50kVp-10MVp x-ray range. Appl Radiat Isot 2006, 64:60-62.
-
(2006)
Appl Radiat Isot
, vol.64
, pp. 60-62
-
-
Butson, M.J.1
Cheung, T.2
Yu, P.K.3
-
10
-
-
79952172951
-
Dosimetry tools and techniques for IMRT
-
Low D.A., Moran J.M., Dempsey J.F., Dong L., Oldham M. Dosimetry tools and techniques for IMRT. Med Phys 2011, 38(3):1313-1338.
-
(2011)
Med Phys
, vol.38
, Issue.3
, pp. 1313-1338
-
-
Low, D.A.1
Moran, J.M.2
Dempsey, J.F.3
Dong, L.4
Oldham, M.5
-
11
-
-
0141520681
-
Analysis of various beamlet sizes for IMRT with 6MV Photons
-
Sohn J.W., Dempsey J.F., Suh T.S., Low D.A. Analysis of various beamlet sizes for IMRT with 6MV Photons. Med Phys 2003, 30(9):2432-2439.
-
(2003)
Med Phys
, vol.30
, Issue.9
, pp. 2432-2439
-
-
Sohn, J.W.1
Dempsey, J.F.2
Suh, T.S.3
Low, D.A.4
-
12
-
-
0008796868
-
Radiochromic film dosimetry: recommendations of AAPM radiation therapy committee task group 55. American association of physicists in medicine
-
Niroomand-Rad A., Blackwell C.R., Coursey B.M., Gall K.P., Galvin J.M., McLaughlin W.L., et al. Radiochromic film dosimetry: recommendations of AAPM radiation therapy committee task group 55. American association of physicists in medicine. Med Phys 1998, 25:2093-2115.
-
(1998)
Med Phys
, vol.25
, pp. 2093-2115
-
-
Niroomand-Rad, A.1
Blackwell, C.R.2
Coursey, B.M.3
Gall, K.P.4
Galvin, J.M.5
McLaughlin, W.L.6
-
13
-
-
80054080436
-
Determination of the correction factors for different ionization chambers used for the calibration of the helical tomotherapy static beam
-
Zeverino M., Agostinelli S., Pupillo F., Taccini G. Determination of the correction factors for different ionization chambers used for the calibration of the helical tomotherapy static beam. Radiother Oncol 2011, 100:424-428.
-
(2011)
Radiother Oncol
, vol.100
, pp. 424-428
-
-
Zeverino, M.1
Agostinelli, S.2
Pupillo, F.3
Taccini, G.4
-
14
-
-
77952395736
-
Energy dependence and dose response of Gafchromic EBT2 film over a wide range of photon, electron, and proton beam energies
-
Arjomandy B., Tailor R., Anand A., Sahoo N., Gillin M., Prado K., et al. Energy dependence and dose response of Gafchromic EBT2 film over a wide range of photon, electron, and proton beam energies. Med Phys 2010, 37(5):1942-1947.
-
(2010)
Med Phys
, vol.37
, Issue.5
, pp. 1942-1947
-
-
Arjomandy, B.1
Tailor, R.2
Anand, A.3
Sahoo, N.4
Gillin, M.5
Prado, K.6
-
15
-
-
4644295382
-
Dosimetric properties of improved GafChromic films for seven different digitizers
-
Devic S., Seuntjens J., Hegyi G., Podgorsak E.B., Soares C.G., Kirov A.S., et al. Dosimetric properties of improved GafChromic films for seven different digitizers. Med Phys 2004, 31:2392-2401.
-
(2004)
Med Phys
, vol.31
, pp. 2392-2401
-
-
Devic, S.1
Seuntjens, J.2
Hegyi, G.3
Podgorsak, E.B.4
Soares, C.G.5
Kirov, A.S.6
-
16
-
-
84885956658
-
-
IAEA Technical Reports Series No. 398. Absorbed dose determination in external beam radiotherapy. Vienna: International Atomic Energy Agency
-
IAEA Technical Reports Series No. 398. Absorbed dose determination in external beam radiotherapy. Vienna: International Atomic Energy Agency; 2004.
-
(2004)
-
-
-
18
-
-
0028114252
-
Supplement to the code of practice for clinical proton dosimetry
-
Vynckier S., Bonnett D.E., Jones D.T.L. Supplement to the code of practice for clinical proton dosimetry. Radiother Oncol 1994, 32:174-179.
-
(1994)
Radiother Oncol
, vol.32
, pp. 174-179
-
-
Vynckier, S.1
Bonnett, D.E.2
Jones, D.T.L.3
-
19
-
-
74549167127
-
LET dependence of GafChromic films and an ion chamber in low-energy proton dosimetry
-
Kirby D., Green S., Palmans H., Hugtenburg R., Wojnecki C., Parker D. LET dependence of GafChromic films and an ion chamber in low-energy proton dosimetry. Phys Med Biol 2010, 55:3741-3751.
-
(2010)
Phys Med Biol
, vol.55
, pp. 3741-3751
-
-
Kirby, D.1
Green, S.2
Palmans, H.3
Hugtenburg, R.4
Wojnecki, C.5
Parker, D.6
-
21
-
-
4444339605
-
Asmall-body portable graphite calorimeter for dosimetry in low-energy clinical proton beams
-
Palmans H., Thomas R., Simon M., Duane S., Kacperek A., DuSautoy A., et al. Asmall-body portable graphite calorimeter for dosimetry in low-energy clinical proton beams. Phys Med Biol 2004, 49:3737-3749.
-
(2004)
Phys Med Biol
, vol.49
, pp. 3737-3749
-
-
Palmans, H.1
Thomas, R.2
Simon, M.3
Duane, S.4
Kacperek, A.5
DuSautoy, A.6
-
22
-
-
33645526701
-
Ion recombination correction in the Clatterbridge Centre of Oncology clinical proton beam
-
Palmans H., Thomas R., Kacperek A. Ion recombination correction in the Clatterbridge Centre of Oncology clinical proton beam. Phys Med Biol 2006, 51:903-917.
-
(2006)
Phys Med Biol
, vol.51
, pp. 903-917
-
-
Palmans, H.1
Thomas, R.2
Kacperek, A.3
-
23
-
-
47649125048
-
Reference dosimetry in a scanned pulsed proton beam using ionisation chambers and a Faraday cup
-
Lorin S., Grusell E., Tilly N., Medin J., Kimstrand P., Glimelius B. Reference dosimetry in a scanned pulsed proton beam using ionisation chambers and a Faraday cup. Phys Med Biol 2008, 53:3519-3529.
-
(2008)
Phys Med Biol
, vol.53
, pp. 3519-3529
-
-
Lorin, S.1
Grusell, E.2
Tilly, N.3
Medin, J.4
Kimstrand, P.5
Glimelius, B.6
-
24
-
-
77952652661
-
Implementation of water calorimetry in a 180 MeV scanned pulsed proton beam including an experimental determination of kQ for a Farmer chamber
-
Medin J. Implementation of water calorimetry in a 180 MeV scanned pulsed proton beam including an experimental determination of kQ for a Farmer chamber. Phys Med Biol 2010, 55:3287-3298.
-
(2010)
Phys Med Biol
, vol.55
, pp. 3287-3298
-
-
Medin, J.1
-
26
-
-
22544440841
-
Precise radiochromic film dosimetry using a flat-bed document scanner
-
Devic S., Seuntjens J., Sham E., Podgorsak E.B., Ross Schmidtlein C., Kirov A.S., et al. Precise radiochromic film dosimetry using a flat-bed document scanner. Med Phys 2005, 32:2245-2253.
-
(2005)
Med Phys
, vol.32
, pp. 2245-2253
-
-
Devic, S.1
Seuntjens, J.2
Sham, E.3
Podgorsak, E.B.4
Ross Schmidtlein, C.5
Kirov, A.S.6
-
27
-
-
59249097881
-
Optimizing the dynamic range extension of a radiochromic film dosimetry system
-
Devic S., Tomic N., Soares C.G., Podgorsak E.B. Optimizing the dynamic range extension of a radiochromic film dosimetry system. Med Phys 2009, 36:429-437.
-
(2009)
Med Phys
, vol.36
, pp. 429-437
-
-
Devic, S.1
Tomic, N.2
Soares, C.G.3
Podgorsak, E.B.4
-
28
-
-
84864712264
-
Comparison of Gafchromic EBT2 and EBT3 films for clinical photon and proton beams
-
Reinhardt S., Hillbrand M., Wilkens J.J., Assmann W. Comparison of Gafchromic EBT2 and EBT3 films for clinical photon and proton beams. Med Phys 2012, 39(8):5227-5262.
-
(2012)
Med Phys
, vol.39
, Issue.8
, pp. 5227-5262
-
-
Reinhardt, S.1
Hillbrand, M.2
Wilkens, J.J.3
Assmann, W.4
-
30
-
-
34547253812
-
Dosimetric characterization of GafChromic EBT film and its implication on film dosimetry quality assurance
-
Fuss M., Sturtewagen E., De Wagter C., Georg D. Dosimetric characterization of GafChromic EBT film and its implication on film dosimetry quality assurance. Phys Med Biol 2007, 52:4211-4225.
-
(2007)
Phys Med Biol
, vol.52
, pp. 4211-4225
-
-
Fuss, M.1
Sturtewagen, E.2
De Wagter, C.3
Georg, D.4
-
31
-
-
33750547402
-
EBT radiochromic film for IMRT dose verification
-
Zeidan O.A., Stephenson S.A.L., Meeks S.L., Wagner T.H., Willoughby T.R., Kupelian P.A., et al. EBT radiochromic film for IMRT dose verification. Med Phys 2006, 33(11):4064-4072.
-
(2006)
Med Phys
, vol.33
, Issue.11
, pp. 4064-4072
-
-
Zeidan, O.A.1
Stephenson, S.A.L.2
Meeks, S.L.3
Wagner, T.H.4
Willoughby, T.R.5
Kupelian, P.A.6
-
32
-
-
21344465230
-
Absorption spectra variations of EBT radiochromic film from radiation exposure
-
Butson M.J., Cheung T., Yu P.K.N. Absorption spectra variations of EBT radiochromic film from radiation exposure. Phys Med Biol 2005, 50:135-140.
-
(2005)
Phys Med Biol
, vol.50
, pp. 135-140
-
-
Butson, M.J.1
Cheung, T.2
Yu, P.K.N.3
|