메뉴 건너뛰기




Volumn 14, Issue 3, 2013, Pages 209-215

Monitoring dialysis arteriovenous fistulae: It's in our hands

Author keywords

Arteriovenous fistulae; Dialysis; Physical examination; Vascular access

Indexed keywords

ANEURYSM; ANGIOGRAPHY; COEXISTENT VENOUS OUTLET STENOSIS; COLLATERAL CIRCULATION; DIAGNOSTIC ACCURACY; HEMODIALYSIS; HEMODYNAMICS; HIGH FLOW FISTULA; HUMAN; KIDNEY ARTERIOVENOUS FISTULA; PHYSICAL EXAMINATION; PRACTICE GUIDELINE; RANDOMIZED CONTROLLED TRIAL (TOPIC); REVIEW; SENSITIVITY AND SPECIFICITY; SIDE TO SIDE UPPER ARM FISTULA; STENOSIS; THROMBOSIS; TRAINING; TRANSPOSED BRACHIO BASILIC FISTULA; VASCULAR ACCESS; VASCULAR PATENCY;

EID: 84885803161     PISSN: 11297298     EISSN: None     Source Type: Journal    
DOI: 10.5301/jva.5000141     Document Type: Review
Times cited : (25)

References (41)
  • 1
    • 33745246339 scopus 로고    scopus 로고
    • Clinical practice guidelines and clinical practice recommendations for vascular access
    • KDOQI
    • KDOQI. Clinical practice guidelines and clinical practice recommendations for vascular access. Am J Kidney Dis. 2006;48:S176-S247.
    • (2006) Am J Kidney Dis. , vol.48
  • 3
    • 0033146613 scopus 로고    scopus 로고
    • Clinical practice guidelines for vascular access. Canadian Society pf Nephrology
    • Canadian Society of Nephrology
    • Ethier JH, Lindsay RM, Barre PE, Kappel JE, Carlisle EJ, Common A; Canadian Society of Nephrology. Clinical practice guidelines for vascular access. Canadian Society pf Nephrology. J Am Soc Nephrol. 1999;10(Suppl 13): S297-S305.
    • (1999) J Am Soc Nephrol. , vol.10 , Issue.SUPPL. 13
    • Ethier, J.H.1    Lindsay, R.M.2    Barre, P.E.3    Kappel, J.E.4    Carlisle, E.J.5    Common, A.6
  • 4
    • 52449120939 scopus 로고    scopus 로고
    • Vascular access use and outcomes: An international perspective from the Dialysis Outcomes and Practice Patterns Study
    • Ethier J, Mendelssohn DC, Elder SJ, et al. Vascular access use and outcomes: an international perspective from the Dialysis Outcomes and Practice Patterns Study. Nephrol Dial Transplant. 2008;23(10):3219-3226.
    • (2008) Nephrol Dial Transplant , vol.23 , Issue.10 , pp. 3219-3226
    • Ethier, J.1    Mendelssohn, D.C.2    Elder, S.J.3
  • 5
    • 34548864410 scopus 로고    scopus 로고
    • Fistula first initiative: Advantages and pitfalls
    • Lok CE. Fistula first initiative: advantages and pitfalls. Clin J Am Soc Nephrol. 2007;2(5):1043-1053.
    • (2007) Clin J Am Soc Nephrol. , vol.2 , Issue.5 , pp. 1043-1053
    • Lok, C.E.1
  • 6
    • 54149109407 scopus 로고    scopus 로고
    • Adding access blood flow surveillance to clinical monitoring reduces thrombosis rates and costs, and improves fistula patency in the short term: A controlled cohort study
    • Tessitore N, Bedogna V, Poli A, et al. Adding access blood flow surveillance to clinical monitoring reduces thrombosis rates and costs, and improves fistula patency in the short term: a controlled cohort study. Nephrol Dial Transplant. 2008;23(11):3578-3584.
    • (2008) Nephrol Dial Transplant , vol.23 , Issue.11 , pp. 3578-3584
    • Tessitore, N.1    Bedogna, V.2    Poli, A.3
  • 8
    • 33751405951 scopus 로고    scopus 로고
    • Impact of a quality improvement programme based on vascular access flow monitoring on costs, access occlusion and access failure
    • Wijnen E, Planken N, Keuter X, et al. Impact of a quality improvement programme based on vascular access flow monitoring on costs, access occlusion and access failure. Nephrol Dial Transplant. 2006;21(12):3514-3519.
    • (2006) Nephrol Dial Transplant , vol.21 , Issue.12 , pp. 3514-3519
    • Wijnen, E.1    Planken, N.2    Keuter, X.3
  • 9
    • 0038512386 scopus 로고    scopus 로고
    • A prospective controlled trial on effect of percutaneous transluminal angioplasty on functioning arteriovenous fistulae survival
    • Tessitore N, Mansueto G, Bedogna V, et al. A prospective controlled trial on effect of percutaneous transluminal angioplasty on functioning arteriovenous fistulae survival. J Am Soc Nephrol. 2003;14(6):1623-1627.
    • (2003) J Am Soc Nephrol. , vol.14 , Issue.6 , pp. 1623-1627
    • Tessitore, N.1    Mansueto, G.2    Bedogna, V.3
  • 10
    • 4444229162 scopus 로고    scopus 로고
    • Can blood flow surveillance and pre-emptive repair of subclinical stenosis prolong the useful life of arteriovenous fistulae? A randomized controlled study
    • Tessitore N, Lipari G, Poli A, et al. Can blood flow surveillance and pre-emptive repair of subclinical stenosis prolong the useful life of arteriovenous fistulae? A randomized controlled study. Nephrol Dial Transplant. 2004;19(9): 2325-2333.
    • (2004) Nephrol Dial Transplant , vol.19 , Issue.9 , pp. 2325-2333
    • Tessitore, N.1    Lipari, G.2    Poli, A.3
  • 11
    • 77953005303 scopus 로고    scopus 로고
    • Validation of QB stress test as a useful tool in the detection of native arteriovenous fistula stenosis: Results after 22 months of follow-up
    • Bonforte G, Pogliani D, Brenna S, et al. Validation of QB stress test as a useful tool in the detection of native arteriovenous fistula stenosis: results after 22 months of follow-up. Nephrol Dial Transplant. 2010;25(6):1943-1949.
    • (2010) Nephrol Dial Transplant , vol.25 , Issue.6 , pp. 1943-1949
    • Bonforte, G.1    Pogliani, D.2    Brenna, S.3
  • 12
    • 38449102500 scopus 로고    scopus 로고
    • Accuracy of physical examination in the detection of arteriovenous fistula stenosis
    • Asif A, Leon C, Orozco-Vargas LC, et al. Accuracy of physical examination in the detection of arteriovenous fistula stenosis. Clin J Am Soc Nephrol. 2007;2(6):1191-1194.
    • (2007) Clin J Am Soc Nephrol. , vol.2 , Issue.6 , pp. 1191-1194
    • Asif, A.1    Leon, C.2    Orozco-Vargas, L.C.3
  • 13
    • 57149127535 scopus 로고    scopus 로고
    • Physical examination of arteriovenous fistulae by a renal fellow: Does it compare favorably to an experienced interventionalist?
    • Leon C, Asif A. Physical examination of arteriovenous fistulae by a renal fellow: does it compare favorably to an experienced interventionalist? Semin Dial. 2008;21(6):557-560.
    • (2008) Semin Dial , vol.21 , Issue.6 , pp. 557-560
    • Leon, C.1    Asif, A.2
  • 14
    • 44649100886 scopus 로고    scopus 로고
    • Accuracy of physical examination and intra-access pressure in the detection of stenosis in hemodialysis arteriovenous fistula
    • Campos RP, Chula DC, Perreto S, Riella MC, do Nascimento MM. Accuracy of physical examination and intra-access pressure in the detection of stenosis in hemodialysis arteriovenous fistula. Semin Dial. 2008;21(3):269-273.
    • (2008) Semin Dial , vol.21 , Issue.3 , pp. 269-273
    • Campos, R.P.1    Chula, D.C.2    Perreto, S.3    Riella, M.C.4    do Nascimento, M.M.5
  • 15
    • 79957888454 scopus 로고    scopus 로고
    • Bedside screening for fistula stenosis should be tailored to the site of the arteriovenous anastomosis
    • Tessitore N, Bedogna V, Lipari G, et al. Bedside screening for fistula stenosis should be tailored to the site of the arteriovenous anastomosis. Clin J Am Soc Nephrol. 2011;6(5):1073-1080.
    • (2011) Clin J Am Soc Nephrol. , vol.6 , Issue.5 , pp. 1073-1080
    • Tessitore, N.1    Bedogna, V.2    Lipari, G.3
  • 16
    • 79955566225 scopus 로고    scopus 로고
    • In search of an optimal bedside screening program for arteriovenous fistula stenosis
    • Tessitore N, Bedogna V, Melilli E, et al. In search of an optimal bedside screening program for arteriovenous fistula stenosis. Clin J Am Soc Nephrol. 2011;6(4):819-826.
    • (2011) Clin J Am Soc Nephrol. , vol.6 , Issue.4 , pp. 819-826
    • Tessitore, N.1    Bedogna, V.2    Melilli, E.3
  • 17
    • 84863999170 scopus 로고    scopus 로고
    • Physical examination of dysfunctional arteriovenous fistulae by non-interventionalists: A skill worth teaching
    • Coentrão L, Faria B, Pestana M. Physical examination of dysfunctional arteriovenous fistulae by non-interventionalists: a skill worth teaching. Nephrol Dial Transplant. 2012;27(5):1993-1996.
    • (2012) Nephrol Dial Transplant , vol.27 , Issue.5 , pp. 1993-1996
    • Coentrão, L.1    Faria, B.2    Pestana, M.3
  • 18
    • 39449121078 scopus 로고    scopus 로고
    • The native arteriovenous fistula in 2007. Surveillance and monitoring
    • Besarab A, Asif A, Roy-Chaudhury P, Spergel LM, Ravani P. The native arteriovenous fistula in 2007. Surveillance and monitoring. J Nephrol. 2007;20(6):656-667.
    • (2007) J Nephrol. , vol.20 , Issue.6 , pp. 656-667
    • Besarab, A.1    Asif, A.2    Roy-Chaudhury, P.3    Spergel, L.M.4    Ravani, P.5
  • 19
    • 44449124638 scopus 로고    scopus 로고
    • The relationship between the flow of arteriovenous fistula and cardiac output in haemodialysis patients
    • Basile C, Lomonte C, Vernaglione L, Casucci F, Antonelli M, Losurdo N. The relationship between the flow of arteriovenous fistula and cardiac output in haemodialysis patients. Nephrol Dial Transplant. 2008;23(1):282-287.
    • (2008) Nephrol Dial Transplant , vol.23 , Issue.1 , pp. 282-287
    • Basile, C.1    Lomonte, C.2    Vernaglione, L.3    Casucci, F.4    Antonelli, M.5    Losurdo, N.6
  • 20
    • 4444355635 scopus 로고    scopus 로고
    • Pressure measurements in the surveillance of vascular accesses
    • In Gray RJ, Sands JJ, eds. Philadelphia, PA: Lippincott Williams & Wilkins
    • Besarab A, Frinak S, Aslam MA. Pressure measurements in the surveillance of vascular accesses. In Gray RJ, Sands JJ, eds. Dialysis Access: A Multidisciplinary Approach. Philadelphia, PA: Lippincott Williams & Wilkins, 2002;137-150.
    • (2002) Dialysis Access: A Multidisciplinary Approach , pp. 137-150
    • Besarab, A.1    Frinak, S.2    Aslam, M.A.3
  • 21
    • 57649101134 scopus 로고    scopus 로고
    • Clinical surveillance and monitoring of arteriovenous access for hemodialysis
    • Gelbfish GA. Clinical surveillance and monitoring of arteriovenous access for hemodialysis. Tech Vasc Interv Radiol. 2008;11(3):156-166.
    • (2008) Tech Vasc Interv Radiol. , vol.11 , Issue.3 , pp. 156-166
    • Gelbfish, G.A.1
  • 22
    • 0030756431 scopus 로고    scopus 로고
    • Hemodialysis access blood flow rates can be measured by a differential conductivity technique and are predictive of access clotting
    • Lindsay RM, Blake PG, Malek P, Posen G, Martin B, Bradfield E. Hemodialysis access blood flow rates can be measured by a differential conductivity technique and are predictive of access clotting. Am J Kidney Dis. 1997;30(4):475-482.
    • (1997) Am J Kidney Dis. , vol.30 , Issue.4 , pp. 475-482
    • Lindsay, R.M.1    Blake, P.G.2    Malek, P.3    Posen, G.4    Martin, B.5    Bradfield, E.6
  • 23
    • 0031463650 scopus 로고    scopus 로고
    • Predictive measures of vascular access thrombosis-a prospective study
    • May RE, Himmelfarb J, Yenicesu M, et al. Predictive measures of vascular access thrombosis-a prospective study. Kidney Int. 1997;52(6):1652-1662.
    • (1997) Kidney Int. , vol.52 , Issue.6 , pp. 1652-1662
    • May, R.E.1    Himmelfarb, J.2    Yenicesu, M.3
  • 24
    • 84885715468 scopus 로고    scopus 로고
    • Predictive values of access blood flow in detecting failure of vascular access
    • Wang E, Schneditz D, Nepomuceno C, et al. Predictive values of access blood flow in detecting failure of vascular access. ASAIO J. 1998;44:554-557.
    • (1998) ASAIO J. , vol.44 , pp. 554-557
    • Wang, E.1    Schneditz, D.2    Nepomuceno, C.3
  • 25
    • 0000495876 scopus 로고    scopus 로고
    • Physical examination of the dialysis vascular access
    • Beathard GA. Physical examination of the dialysis vascular access. Semin Dial. 1998;11(4):231-236.
    • (1998) Semin Dial , vol.11 , Issue.4 , pp. 231-236
    • Beathard, G.A.1
  • 26
    • 23844460847 scopus 로고    scopus 로고
    • An algorithm for the physical examination of early fistula failure
    • Beathard GA. An algorithm for the physical examination of early fistula failure. Semin Dial. 2005;18(4):331-335.
    • (2005) Semin Dial , vol.18 , Issue.4 , pp. 331-335
    • Beathard, G.A.1
  • 27
    • 0141691967 scopus 로고    scopus 로고
    • Physical examination: The forgotten tool
    • In Gray RJ, Sands JJ, eds. Philadelphia, PA: Lippincott Williams & Wilkins
    • Beathard GA. Physical examination: the forgotten tool. In Gray RJ, Sands JJ, eds. Dialysis Access: A Multidisciplinary Approach. Philadelphia, PA: Lippincott Williams & Wilkins, 2002;111-118.
    • (2002) Dialysis Access: A Multidisciplinary Approach , pp. 111-118
    • Beathard, G.A.1
  • 28
    • 0029690931 scopus 로고    scopus 로고
    • Screening for dialysis access graft malfunction: Comparison of physical examination with US
    • Trerotola SO, Scheel PJ Jr, Powe NR, et al. Screening for dialysis access graft malfunction: comparison of physical examination with US. J Vasc Interv Radiol. 1996;7(1):15-20.
    • (1996) J Vasc Interv Radiol. , vol.7 , Issue.1 , pp. 15-20
    • Trerotola, S.O.1    Scheel Jr., P.J.2    Powe, N.R.3
  • 29
    • 0034809842 scopus 로고    scopus 로고
    • Buzz in the axilla: A new physical sign in hemodialysis forearm graft evaluation
    • Agarwal R, McDougal G. Buzz in the axilla: a new physical sign in hemodialysis forearm graft evaluation. Am J Kidney Dis. 2001;38(4):853-857.
    • (2001) Am J Kidney Dis. , vol.38 , Issue.4 , pp. 853-857
    • Agarwal, R.1    McDougal, G.2
  • 30
    • 34548532228 scopus 로고    scopus 로고
    • Arteriovenous access and hand pain: The distal hypoperfusion ischemic syndrome
    • Leon C, Asif A. Arteriovenous access and hand pain: the distal hypoperfusion ischemic syndrome. Clin J Am Soc Nephrol. 2007;2(1):175-183.
    • (2007) Clin J Am Soc Nephrol. , vol.2 , Issue.1 , pp. 175-183
    • Leon, C.1    Asif, A.2
  • 31
    • 0035207240 scopus 로고    scopus 로고
    • Salvage of immature forearm fistulas for haemodialysis by interventional radiology
    • Turmel-Rodrigues L, Mouton A, Birmelé B, et al. Salvage of immature forearm fistulas for haemodialysis by interventional radiology. Nephrol Dial Transplant. 2001;16(12): 2365-2371.
    • (2001) Nephrol Dial Transplant , vol.16 , Issue.12 , pp. 2365-2371
    • Turmel-Rodrigues, L.1    Mouton, A.2    Birmelé, B.3
  • 32
    • 84859339535 scopus 로고    scopus 로고
    • Comparative outcomes of treated symptomatic versus non-treated asymptomatic high-grade central vein stenoses in the outflow of predominantly dialysis fistulas
    • Renaud CJ, Francois M, Nony A, Fodil-Cherif M, Turmel-Rodrigues L. Comparative outcomes of treated symptomatic versus non-treated asymptomatic high-grade central vein stenoses in the outflow of predominantly dialysis fistulas. Nephrol Dial Transplant. 2012;27(4):1631-1638.
    • (2012) Nephrol Dial Transplant , vol.27 , Issue.4 , pp. 1631-1638
    • Renaud, C.J.1    Francois, M.2    Nony, A.3    Fodil-Cherif, M.4    Turmel-Rodrigues, L.5
  • 35
    • 0029048657 scopus 로고
    • Utility of intra-access pressure monitoring in detecting and correcting venous outlet stenoses prior to thrombosis
    • Besarab A, Sullivan KL, Ross RP, Moritz MJ. Utility of intra-access pressure monitoring in detecting and correcting venous outlet stenoses prior to thrombosis. Kidney Int. 1995;47(5):1364-1373.
    • (1995) Kidney Int. , vol.47 , Issue.5 , pp. 1364-1373
    • Besarab, A.1    Sullivan, K.L.2    Ross, R.P.3    Moritz, M.J.4
  • 36
    • 0028886525 scopus 로고
    • Prolongation of hemodialysis access survival with elective revision
    • Sands JJ, Miranda CL. Prolongation of hemodialysis access survival with elective revision. Clin Nephrol. 1995;44(5):329-333.
    • (1995) Clin Nephrol. , vol.44 , Issue.5 , pp. 329-333
    • Sands, J.J.1    Miranda, C.L.2
  • 37
    • 0030885315 scopus 로고    scopus 로고
    • Prophylactic balloon angioplasty fails to prolong the patency of expanded polytetrafluoroethylene arteriovenous grafts: Results of a prospective randomized study
    • discussion 390-392
    • Lumsden AB, MacDonald MJ, Kikeri D, Cotsonis GA, Harker LA, Martin LG. Prophylactic balloon angioplasty fails to prolong the patency of expanded polytetrafluoroethylene arteriovenous grafts: results of a prospective randomized study. J Vasc Surg. 1997;26(3):382-390, discussion 390-392.
    • (1997) J Vasc Surg. , vol.26 , Issue.3 , pp. 382-390
    • Lumsden, A.B.1    McDonald, M.J.2    Kikeri, D.3    Cotsonis, G.A.4    Harker, L.A.5    Martin, L.G.6
  • 38
    • 0038468806 scopus 로고    scopus 로고
    • A randomized controlled trial of blood flow and stenosis surveillance of hemodialysis grafts
    • Ram SJ, Work J, Caldito GC, Eason JM, Pervez A, Paulson WD. A randomized controlled trial of blood flow and stenosis surveillance of hemodialysis grafts. Kidney Int. 2003;64(1):272-280.
    • (2003) Kidney Int. , vol.64 , Issue.1 , pp. 272-280
    • Ram, S.J.1    Work, J.2    Caldito, G.C.3    Eason, J.M.4    Pervez, A.5    Paulson, W.D.6
  • 39
    • 0141566810 scopus 로고    scopus 로고
    • Regular monitoring of access flow compared with monitoring of venous pressure fails to improve graft survival
    • Moist LM, Churchill DN, House AA, et al. Regular monitoring of access flow compared with monitoring of venous pressure fails to improve graft survival. J Am Soc Nephrol. 2003;14(10):2545-2653.
    • (2003) J Am Soc Nephrol. , vol.14 , Issue.10 , pp. 2545-2653
    • Moist, L.M.1    Churchill, D.N.2    House, A.A.3
  • 40
    • 3042723504 scopus 로고    scopus 로고
    • Randomized controlled trial of prophylactic repair of hemodialysis arteriovenous graft stenosis
    • Dember LM, Holmberg EF, Kaufman JS. Randomized controlled trial of prophylactic repair of hemodialysis arteriovenous graft stenosis. Kidney Int. 2004;66(1):390-398.
    • (2004) Kidney Int. , vol.66 , Issue.1 , pp. 390-398
    • Dember, L.M.1    Holmberg, E.F.2    Kaufman, J.S.3
  • 41
    • 32544454696 scopus 로고    scopus 로고
    • Randomized comparison of ultrasound surveillance and clinical monitoring on arteriovenous graft outcomes
    • Robbin ML, Oser RF, Lee JY, Heudebert GR, Mennemeyer ST, Allon M. Randomized comparison of ultrasound surveillance and clinical monitoring on arteriovenous graft outcomes. Kidney Int. 2006;69(4):730-735.
    • (2006) Kidney Int. , vol.69 , Issue.4 , pp. 730-735
    • Robbin, M.L.1    Oser, R.F.2    Lee, J.Y.3    Heudebert, G.R.4    Mennemeyer, S.T.5    Allon, M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.