메뉴 건너뛰기




Volumn 20, Issue 11, 2013, Pages 1334-1343

Scatter correction associated with dedicated dual-source ct hardware improves accuracy of lung air measures

Author keywords

COPD; Dual energy; Emphysema; Lung density; Quantitative CT

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ARTICLE; CHRONIC OBSTRUCTIVE LUNG DISEASE; COMPUTED TOMOGRAPHY SCANNER; COMPUTER ASSISTED TOMOGRAPHY; DIAGNOSTIC ACCURACY; DIAGNOSTIC TEST ACCURACY STUDY; DUAL SOURCE DUAL ENERGY SCAN; IN VIVO STUDY; INFERIOR CAVA VEIN; INTERMETHOD COMPARISON; LUNG EMPHYSEMA; LUNG PARENCHYMA; NONHUMAN; PHANTOM; PRIORITY JOURNAL; SINGLE SOURCE COMPUTER ASSISTED TOMOGRAPHY; SWINE; X RAY TUBE;

EID: 84885357796     PISSN: 10766332     EISSN: 18784046     Source Type: Journal    
DOI: 10.1016/j.acra.2013.04.018     Document Type: Article
Times cited : (14)

References (35)
  • 1
    • 77950149463 scopus 로고    scopus 로고
    • Quantitative CT assessmentof chronic obstructive pulmonary disease
    • Matsuoka S., Yamashiro T., Washko G.R., et al. Quantitative CT assessmentof chronic obstructive pulmonary disease. Radiographics 2010, 30:55-66.
    • (2010) Radiographics , vol.30 , pp. 55-66
    • Matsuoka, S.1    Yamashiro, T.2    Washko, G.R.3
  • 2
    • 33947360327 scopus 로고    scopus 로고
    • Quantitative CT of fibrotic interstitial lung disease
    • Lynch D.A. Quantitative CT of fibrotic interstitial lung disease. Chest 2007, 131:643-644.
    • (2007) Chest , vol.131 , pp. 643-644
    • Lynch, D.A.1
  • 3
    • 77956114536 scopus 로고    scopus 로고
    • Chronic obstructive pulmonary disease: quantitative and visual ventilation pattern analysis at xenon ventilation CT performed by using a dual-energy technique
    • Park E.A., Goo J.M., Park S.J., et al. Chronic obstructive pulmonary disease: quantitative and visual ventilation pattern analysis at xenon ventilation CT performed by using a dual-energy technique. Radiology 2010, 256:985-997.
    • (2010) Radiology , vol.256 , pp. 985-997
    • Park, E.A.1    Goo, J.M.2    Park, S.J.3
  • 4
    • 69549114757 scopus 로고    scopus 로고
    • Quantitative imaging of COPD
    • Lynch D.A., Newell J.D. Quantitative imaging of COPD. J Thorac Imaging 2009, 24:189-194.
    • (2009) J Thorac Imaging , vol.24 , pp. 189-194
    • Lynch, D.A.1    Newell, J.D.2
  • 5
    • 84863229324 scopus 로고    scopus 로고
    • The National Lung Screening Trial: overview and study design
    • Team N.L.S.T.R.
    • Team N.L.S.T.R., Aberle D.R., Berg C.D., et al. The National Lung Screening Trial: overview and study design. Radiology 2011, 258:243-253.
    • (2011) Radiology , vol.258 , pp. 243-253
    • Aberle, D.R.1    Berg, C.D.2
  • 6
    • 79251586523 scopus 로고    scopus 로고
    • Association of COPD candidate genes with computed tomography emphysema and airway phenotypes in severe COPD
    • Kim W.J., Hoffman E.A., Reilly J., et al. Association of COPD candidate genes with computed tomography emphysema and airway phenotypes in severe COPD. Eur Resp J 2011, 37:39-43.
    • (2011) Eur Resp J , vol.37 , pp. 39-43
    • Kim, W.J.1    Hoffman, E.A.2    Reilly, J.3
  • 7
    • 71049138601 scopus 로고    scopus 로고
    • Identification of early interstitial lung disease in smokers from the COPDGene Study
    • Washko G.R., Lynch D.A., Matsuoka S., et al. Identification of early interstitial lung disease in smokers from the COPDGene Study. Acad Radiol 2010, 17:48-53.
    • (2010) Acad Radiol , vol.17 , pp. 48-53
    • Washko, G.R.1    Lynch, D.A.2    Matsuoka, S.3
  • 8
    • 28044434639 scopus 로고    scopus 로고
    • Variability in densitometric assessment of pulmonary emphysema with computed tomography
    • Bakker M.E., Stolk J., Putter H., et al. Variability in densitometric assessment of pulmonary emphysema with computed tomography. Invest Radiol 2005, 40:777-783.
    • (2005) Invest Radiol , vol.40 , pp. 777-783
    • Bakker, M.E.1    Stolk, J.2    Putter, H.3
  • 9
    • 0032967270 scopus 로고    scopus 로고
    • Pulmonary emphysema: subjective visual grading versus objective quantification with macroscopic morphometry and thin-section CT densitometry
    • Bankier A.A., De Maertelaer V., Keyzer C., et al. Pulmonary emphysema: subjective visual grading versus objective quantification with macroscopic morphometry and thin-section CT densitometry. Radiology 1999, 211:851-858.
    • (1999) Radiology , vol.211 , pp. 851-858
    • Bankier, A.A.1    De Maertelaer, V.2    Keyzer, C.3
  • 10
    • 0026627792 scopus 로고
    • Regional distribution of emphysema: correlation of high-resolution CT with pulmonary function tests in unselected smokers
    • Gurney J.W., Jones K.K., Robbins R.A., et al. Regional distribution of emphysema: correlation of high-resolution CT with pulmonary function tests in unselected smokers. Radiology 1992, 183:457-463.
    • (1992) Radiology , vol.183 , pp. 457-463
    • Gurney, J.W.1    Jones, K.K.2    Robbins, R.A.3
  • 11
    • 0031882660 scopus 로고    scopus 로고
    • Expiratory CT scans for chronic airway disease: correlation with pulmonary function test results
    • Lucidarme O., Coche E., Cluzel P., et al. Expiratory CT scans for chronic airway disease: correlation with pulmonary function test results. AJR Am J Roentgenol 1998, 170:301-307.
    • (1998) AJR Am J Roentgenol , vol.170 , pp. 301-307
    • Lucidarme, O.1    Coche, E.2    Cluzel, P.3
  • 12
    • 0025739815 scopus 로고
    • Expiratory computed tomography for assessment of suspected pulmonary emphysema
    • Knudson R.J., Standen J.R., Kaltenborn W.T., et al. Expiratory computed tomography for assessment of suspected pulmonary emphysema. Chest 1991, 99:1357-1366.
    • (1991) Chest , vol.99 , pp. 1357-1366
    • Knudson, R.J.1    Standen, J.R.2    Kaltenborn, W.T.3
  • 13
    • 77958470138 scopus 로고    scopus 로고
    • Imaging biomarkers for patient selection and treatment planning in emphysema
    • Brown M., Abtin F., Kim H.J., et al. Imaging biomarkers for patient selection and treatment planning in emphysema. Imaging Med 2010, 2:565-573.
    • (2010) Imaging Med , vol.2 , pp. 565-573
    • Brown, M.1    Abtin, F.2    Kim, H.J.3
  • 14
    • 71249089216 scopus 로고    scopus 로고
    • Volumetric CT in lung cancer: an example for the qualification of imaging as a biomarker.
    • Buckler AJ, Mozley PD, Schwartz L, etal. Volumetric CT in lung cancer: an example for the qualification of imaging as a biomarker. 2010; 17:107-115.
    • (2010) , vol.17 , pp. 107-115
    • Buckler, A.J.1    Mozley, P.D.2    Schwartz, L.3
  • 15
    • 80052671827 scopus 로고    scopus 로고
    • The role of CT scanning in multidimensional phenotyping of COPD
    • Bafadhel M., Umar I., Gupta S., et al. The role of CT scanning in multidimensional phenotyping of COPD. Chest 2011, 140:634-642.
    • (2011) Chest , vol.140 , pp. 634-642
    • Bafadhel, M.1    Umar, I.2    Gupta, S.3
  • 16
    • 69549103465 scopus 로고    scopus 로고
    • Imaging the lungs in patients with pulmonary emphysema
    • Goldin J.G. Imaging the lungs in patients with pulmonary emphysema. JThorac Imaging 2009, 24:163-170.
    • (2009) JThorac Imaging , vol.24 , pp. 163-170
    • Goldin, J.G.1
  • 17
    • 57349145358 scopus 로고    scopus 로고
    • Quantitative computed tomography of lung parenchyma in chronic obstructive pulmonary disease: an overview
    • Newell J.D. Quantitative computed tomography of lung parenchyma in chronic obstructive pulmonary disease: an overview. Proc Am Thorac Soc 2008, 5:915-918.
    • (2008) Proc Am Thorac Soc , vol.5 , pp. 915-918
    • Newell, J.D.1
  • 18
    • 27244433717 scopus 로고    scopus 로고
    • Quantitative computed tomography of chronic obstructive pulmonary disease
    • Coxson H.O., Rogers Robert M. Quantitative computed tomography of chronic obstructive pulmonary disease. Acad Radiol 2005, 12:1457-1463.
    • (2005) Acad Radiol , vol.12 , pp. 1457-1463
    • Coxson, H.O.1    Rogers Robert, M.2
  • 19
    • 2442424431 scopus 로고    scopus 로고
    • Report of a workshop: quantitative computed tomography scanning in longitudinal studies of emphysema
    • Newell J.D., Hogg J.C., Snider G.L. Report of a workshop: quantitative computed tomography scanning in longitudinal studies of emphysema. Eur Resp J 2004, 23:769-775.
    • (2004) Eur Resp J , vol.23 , pp. 769-775
    • Newell, J.D.1    Hogg, J.C.2    Snider, G.L.3
  • 20
    • 0347291903 scopus 로고    scopus 로고
    • Correlation between annual change in health status and computer tomography derived lung density in subjects with alpha1-antitrypsin deficiency
    • Stolk J., Ng W.H., Bakker M.E., et al. Correlation between annual change in health status and computer tomography derived lung density in subjects with alpha1-antitrypsin deficiency. Thorax 2003, 58:1027-1030.
    • (2003) Thorax , vol.58 , pp. 1027-1030
    • Stolk, J.1    Ng, W.H.2    Bakker, M.E.3
  • 21
    • 57349122437 scopus 로고    scopus 로고
    • Quantitative computed tomography assessment of airway wall dimensions: current status and potential applications for phenotyping chronic obstructive pulmonary disease
    • Coxson H.O. Quantitative computed tomography assessment of airway wall dimensions: current status and potential applications for phenotyping chronic obstructive pulmonary disease. Proc Am Thorac Soc 2008, 5:940-945.
    • (2008) Proc Am Thorac Soc , vol.5 , pp. 940-945
    • Coxson, H.O.1
  • 22
    • 33747858396 scopus 로고    scopus 로고
    • A structural and functional assessment of the lung via multidetector-row computed tomography: phenotyping chronic obstructive pulmonary disease
    • Hoffman E.A., Simon B.A., McLennan G. A structural and functional assessment of the lung via multidetector-row computed tomography: phenotyping chronic obstructive pulmonary disease. Proc Am Thorac Soc 2006, 3:519-534.
    • (2006) Proc Am Thorac Soc , vol.3 , pp. 519-534
    • Hoffman, E.A.1    Simon, B.A.2    McLennan, G.3
  • 23
    • 67649407825 scopus 로고    scopus 로고
    • Exploring the role of CT densitometry: a randomised study of augmentation therapy in alpha1-antitrypsin deficiency
    • Dirksen A., Piitulainen E., Parr D.G., et al. Exploring the role of CT densitometry: a randomised study of augmentation therapy in alpha1-antitrypsin deficiency. Eur Resp J 2009, 33:1345-1353.
    • (2009) Eur Resp J , vol.33 , pp. 1345-1353
    • Dirksen, A.1    Piitulainen, E.2    Parr, D.G.3
  • 24
    • 72049130251 scopus 로고    scopus 로고
    • Dual-source spiral CT with pitch up to 3.2 and75 ms temporal resolution: image reconstruction and assessment of image quality
    • Flohr T.G., Leng S., Yu L., et al. Dual-source spiral CT with pitch up to 3.2 and75 ms temporal resolution: image reconstruction and assessment of image quality. Med Phys 2009, 36:5641-5653.
    • (2009) Med Phys , vol.36 , pp. 5641-5653
    • Flohr, T.G.1    Leng, S.2    Yu, L.3
  • 25
    • 34248673159 scopus 로고    scopus 로고
    • Material differentiation by dual energy CT: initial experience
    • Johnson T.R.C., Krauss B., Sedlmair M., et al. Material differentiation by dual energy CT: initial experience. Eur Radiol 2007, 17:1510-1517.
    • (2007) Eur Radiol , vol.17 , pp. 1510-1517
    • Johnson, T.R.C.1    Krauss, B.2    Sedlmair, M.3
  • 26
    • 61349119238 scopus 로고    scopus 로고
    • Image quality optimization and evaluation oflinearly mixed images in dual-source, dual-energy CT
    • Yu L., Primak A.N., Liu X., et al. Image quality optimization and evaluation oflinearly mixed images in dual-source, dual-energy CT. Med Phys 2009, 36:1019.
    • (2009) Med Phys , vol.36 , pp. 1019
    • Yu, L.1    Primak, A.N.2    Liu, X.3
  • 27
    • 78649692112 scopus 로고    scopus 로고
    • Dual-source dual-energy CT with additional tin filtration: dose and image quality evaluation in phantoms and invivo
    • Primak A.N., Giraldo J.C.R., Eusemann C.D., et al. Dual-source dual-energy CT with additional tin filtration: dose and image quality evaluation in phantoms and invivo. AJR Am J Roentgenol 2010, 195:1164-1174.
    • (2010) AJR Am J Roentgenol , vol.195 , pp. 1164-1174
    • Primak, A.N.1    Giraldo, J.C.R.2    Eusemann, C.D.3
  • 28
    • 78149455882 scopus 로고    scopus 로고
    • Strategies for scatter correction in dual source CT
    • Petersilka M., Stierstorfer K., Bruder H., et al. Strategies for scatter correction in dual source CT. Med Phys 2010, 37:5971-5992.
    • (2010) Med Phys , vol.37 , pp. 5971-5992
    • Petersilka, M.1    Stierstorfer, K.2    Bruder, H.3
  • 29
    • 77952155116 scopus 로고    scopus 로고
    • Pulmonary Analysis Software Suite 9.0 Integrating quantitative measures of function with structural analyses
    • M. Brown (Ed.)
    • Guo J., Fuld M., Alford S.K., et al. Pulmonary Analysis Software Suite 9.0 Integrating quantitative measures of function with structural analyses. First International Workshop on Pulmonary Image Analysis 2008, 283-292. M. Brown (Ed.).
    • (2008) First International Workshop on Pulmonary Image Analysis , pp. 283-292
    • Guo, J.1    Fuld, M.2    Alford, S.K.3
  • 30
    • 84886717515 scopus 로고    scopus 로고
    • COPDGene Phantom: quality control of quantitative lung imaging in a multi-center trial
    • Sieren J.P., Gunderson K., Lynch D.A., et al. COPDGene Phantom: quality control of quantitative lung imaging in a multi-center trial. Am J Resp Crit Care Med 2010, 181:A5519.
    • (2010) Am J Resp Crit Care Med , vol.181
    • Sieren, J.P.1    Gunderson, K.2    Lynch, D.A.3
  • 31
    • 43149110419 scopus 로고    scopus 로고
    • Correction of cross-scatter in next generation dual source CT (DSCT) scanners
    • Bruder H., Stierstorfer K., Petersilka M., et al. Correction of cross-scatter in next generation dual source CT (DSCT) scanners. Proc SPIE 2008, 6913:69131W.
    • (2008) Proc SPIE , vol.6913
    • Bruder, H.1    Stierstorfer, K.2    Petersilka, M.3
  • 32
    • 0032605125 scopus 로고    scopus 로고
    • Efficient object scatter correction algorithm for third and fourth generation CT scanners
    • Ohnesorge B., Flohr T., Klingenbeck-Regn K. Efficient object scatter correction algorithm for third and fourth generation CT scanners. Eur Radiol 1999, 9:563-569.
    • (1999) Eur Radiol , vol.9 , pp. 563-569
    • Ohnesorge, B.1    Flohr, T.2    Klingenbeck-Regn, K.3
  • 33
    • 33845562622 scopus 로고    scopus 로고
    • Scatter correction method for X-ray CT usingprimary modulation: theory and preliminary results
    • Zhu L., Bennett N.R., Fahrig R. Scatter correction method for X-ray CT usingprimary modulation: theory and preliminary results. IEEE Trans Med Imaging 2006, 25:1573-1587.
    • (2006) IEEE Trans Med Imaging , vol.25 , pp. 1573-1587
    • Zhu, L.1    Bennett, N.R.2    Fahrig, R.3
  • 34
    • 31044451240 scopus 로고    scopus 로고
    • A simple, direct method for x-ray scatter estimation and correction in digital radiography and cone-beam CT
    • Siewerdsen J.H., Daly M.J., Bakhtiar B., et al. A simple, direct method for x-ray scatter estimation and correction in digital radiography and cone-beam CT. Med Phys 2006, 33:187-197.
    • (2006) Med Phys , vol.33 , pp. 187-197
    • Siewerdsen, J.H.1    Daly, M.J.2    Bakhtiar, B.3
  • 35
    • 77955129810 scopus 로고    scopus 로고
    • Effect of beam hardening on arterialenhancement in thoracoabdominal CT angiography with increasing patient size: an invitro and invivo study
    • Schindera S.T., Tock I., Marin D., et al. Effect of beam hardening on arterialenhancement in thoracoabdominal CT angiography with increasing patient size: an invitro and invivo study. Radiology 2010, 256:528-535.
    • (2010) Radiology , vol.256 , pp. 528-535
    • Schindera, S.T.1    Tock, I.2    Marin, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.