2
-
-
43249110916
-
Simulation and analysis of sewage-source heat pump for low temperature wastewater treatment (in Chinese)
-
Yao Y, Song Y, Na W. Simulation and analysis of sewage-source heat pump for low temperature wastewater treatment (in Chinese). Chin Water Wastewater. 2006 ; 13: 70-73
-
(2006)
Chin Water Wastewater
, vol.13
, pp. 70-73
-
-
Yao, Y.1
Song, Y.2
Na, W.3
-
3
-
-
76049118703
-
Application of an exhaust heat recovery system for domestic hot water
-
Liu LB, Fu L, Jiang Y. Application of an exhaust heat recovery system for domestic hot water. Energy. 2010 ; 35: 1476-1481
-
(2010)
Energy
, vol.35
, pp. 1476-1481
-
-
Liu, L.B.1
Fu, L.2
Jiang, Y.3
-
4
-
-
84886370809
-
Discussion on heat recovery of waste water in college bathroom and the meaning of energy saving and emission reduction
-
Wang RH, Feng SH. Discussion on heat recovery of waste water in college bathroom and the meaning of energy saving and emission reduction. Constr Conserves Energy. 2008 ; 5: 72-74
-
(2008)
Constr Conserves Energy
, vol.5
, pp. 72-74
-
-
Wang, R.H.1
Feng, S.H.2
-
5
-
-
13844292559
-
A study on the design and analysis of a heat pump heating system using wastewater as a heat source
-
Baek NC, Shin UC, Yoon JH. A study on the design and analysis of a heat pump heating system using wastewater as a heat source. Sol Energy. 2005 ; 78: 427-440
-
(2005)
Sol Energy
, vol.78
, pp. 427-440
-
-
Baek, N.C.1
Shin, U.C.2
Yoon, J.H.3
-
6
-
-
70349487509
-
Investigation of the performance of a heat pump using waste water as a heat source
-
Ali K, Alaeddin C. Investigation of the performance of a heat pump using waste water as a heat source. Energies. 2009 ; 2: 697-713
-
(2009)
Energies
, vol.2
, pp. 697-713
-
-
Ali, K.1
Alaeddin, C.2
-
7
-
-
0002156577
-
-
Characklis WG Marshall KC, ed. New York: John Wiley;
-
Characklis WG Biofilms. Characklis WG Marshall KC, ed. New York: John Wiley ; 1990: 523-584.
-
(1990)
Biofilms
, pp. 523-584
-
-
Characklis, W.G.1
-
8
-
-
85040853797
-
-
Park Ridge, NJ: Noyes Publications;
-
Garret-Price BA, Smith SA, Watts RL, et al Fouling of heat exchangers - characteristics, costs, prevention, control and removal. Park Ridge, NJ: Noyes Publications ; 1985 :
-
(1985)
Fouling of Heat Exchangers - Characteristics, Costs, Prevention, Control and Removal
-
-
Garret-Price, B.A.1
Smith, S.A.2
Watts, R.L.3
-
9
-
-
0031199105
-
Effects of fouling on the efficiency of heat exchangers in lignite utility boilers
-
Bergeles G, Bouris D, Yianneskis M, et al. Effects of fouling on the efficiency of heat exchangers in lignite utility boilers. Appl Therm Eng. 1997 ; 17 (8-10). 739-749
-
(1997)
Appl Therm Eng
, vol.17
, Issue.810
, pp. 739-749
-
-
Bergeles, G.1
Bouris, D.2
Yianneskis, M.3
-
10
-
-
2542508241
-
Influence of the adhesion force crystal/heat exchanger surface on fouling mitigation
-
Förster M, Augustin W, Bohnet M. Influence of the adhesion force crystal/heat exchanger surface on fouling mitigation. Chem Eng Process. 1999 ; 38: 449-461
-
(1999)
Chem Eng Process
, vol.38
, pp. 449-461
-
-
Förster, M.1
Augustin, W.2
Bohnet, M.3
-
11
-
-
84863514957
-
Numerical evaluation of a heat exchanger with inline tubes of different size for reduced fouling rates
-
Mavridou SG, Bouris DG. Numerical evaluation of a heat exchanger with inline tubes of different size for reduced fouling rates. Int J Heat Mass Transfer. 2012 ; 55: 5185-5195
-
(2012)
Int J Heat Mass Transfer
, vol.55
, pp. 5185-5195
-
-
Mavridou, S.G.1
Bouris, D.G.2
-
12
-
-
34247542104
-
Model for fouling deposition on power plant steam condensers cooled with seawater: Effect of water velocity and tube material
-
Nebot JF, Casanueva T, Sales CD. Model for fouling deposition on power plant steam condensers cooled with seawater: effect of water velocity and tube material. Int J Heat Mass Transfer. 2007 ; 50: 3351-3358
-
(2007)
Int J Heat Mass Transfer
, vol.50
, pp. 3351-3358
-
-
Nebot, J.F.1
Casanueva, T.2
Sales, C.D.3
-
13
-
-
0023961906
-
Particle transport in fouling caused by kaolin-water suspensions on copper tubes
-
Melo LF, Pinheiro JD. Particle transport in fouling caused by kaolin-water suspensions on copper tubes. Can J Chem Eng. 1988 ; 66: 36-41
-
(1988)
Can J Chem Eng
, vol.66
, pp. 36-41
-
-
Melo, L.F.1
Pinheiro, J.D.2
-
14
-
-
0035388814
-
Effect of electronic anti-fouling treatment on fouling mitigation with circulating cooling-tower water
-
Kim WT, Cho YI, Bai C. Effect of electronic anti-fouling treatment on fouling mitigation with circulating cooling-tower water. Heat Mass Transfer. 2001 ; 28 (5). 671-680
-
(2001)
Heat Mass Transfer
, vol.28
, Issue.5
, pp. 671-680
-
-
Kim, W.T.1
Cho, Y.I.2
Bai, C.3
-
15
-
-
0023844053
-
Describing the experimental uncertainties in experimental results
-
Moffat RJ. Describing the experimental uncertainties in experimental results. Exp Therm Fluid Sci. 1988 ; 1: 3-17
-
(1988)
Exp Therm Fluid Sci
, vol.1
, pp. 3-17
-
-
Moffat, R.J.1
-
16
-
-
0019444686
-
Early fouling biofilm formation in a turbulent flow system: Overall kinetics
-
Bryers J, Characklis W. Early fouling biofilm formation in a turbulent flow system: overall kinetics. Water Res. 1981 ; 15: 483-491
-
(1981)
Water Res
, vol.15
, pp. 483-491
-
-
Bryers, J.1
Characklis, W.2
|