Volumn 116, Issue , 2013, Pages 73-76

Magnetic resonance imaging safety of deep brain stimulator devices

Author keywords

Deep brain stimulation; Magnetic resonance imaging; Safety

Indexed keywords

ANIMAL; ARTICLE; BRAIN; BRAIN DEPTH STIMULATION; EQUIPMENT; HUMAN; METHODOLOGY; MOTOR DYSFUNCTION; NUCLEAR MAGNETIC RESONANCE IMAGING; PATHOLOGY; PHYSIOLOGY; SAFETY;

EID: 84885151190     PISSN: 00729752     EISSN: None     Source Type: Book Series    
DOI: 10.1016/B978-0-444-53497-2.00007-3     Document Type: Chapter
Times cited : (19)

References (9)
  • 1
    • 3242785606 scopus 로고    scopus 로고
    • Evaluation of specific absorption rate as a dosimeter of MRI-related implant heating
    • Baker K.B., Tkach J.A., Nyenhuis J.A., et al. Evaluation of specific absorption rate as a dosimeter of MRI-related implant heating. J Magn Reson Imaging 2004, 20:315-320.
    • (2004) J Magn Reson Imaging , vol.20 , pp. 315-320
    • Baker, K.B.1    Tkach, J.A.2    Nyenhuis, J.A.3
  • 2
    • 26844503103 scopus 로고    scopus 로고
    • Reduction of magnetic resonance imaging-related heating in deep brain stimulation leads using a lead management device
    • Baker K.B., Tkach J., Hall J.D., et al. Reduction of magnetic resonance imaging-related heating in deep brain stimulation leads using a lead management device. Neurosurgery 2005, 57:392-397.
    • (2005) Neurosurgery , vol.57 , pp. 392-397
    • Baker, K.B.1    Tkach, J.2    Hall, J.D.3
  • 3
    • 79953884593 scopus 로고    scopus 로고
    • MRI-related heating near deep brain stimulation electrodes: more data are needed
    • Gupte A.A., Shrivastava D., Spaniol M.A., et al. MRI-related heating near deep brain stimulation electrodes: more data are needed. Stereotact Funct Neurosurg 2011, 89:131-140.
    • (2011) Stereotact Funct Neurosurg , vol.89 , pp. 131-140
    • Gupte, A.A.1    Shrivastava, D.2    Spaniol, M.A.3
  • 4
    • 27644509327 scopus 로고    scopus 로고
    • Permanent neurological deficit related to magnetic resonance imaging in a patient with implanted deep brain stimulation electrodes for Parkinson's disease: case report
    • Henderson J.M., Tkach J., Phillips M., et al. Permanent neurological deficit related to magnetic resonance imaging in a patient with implanted deep brain stimulation electrodes for Parkinson's disease: case report. Neurosurgery 2005, 57:E1063.
    • (2005) Neurosurgery , vol.57
    • Henderson, J.M.1    Tkach, J.2    Phillips, M.3
  • 5
    • 40349084189 scopus 로고    scopus 로고
    • Magnetic resonance imaging of implanted deep brain stimulators: experience in a large series
    • Larson P.S., Richardson R.M., Starr P.A., et al. Magnetic resonance imaging of implanted deep brain stimulators: experience in a large series. Stereotact Funct Neurosurg 2008, 86:92-100.
    • (2008) Stereotact Funct Neurosurg , vol.86 , pp. 92-100
    • Larson, P.S.1    Richardson, R.M.2    Starr, P.A.3
  • 6
    • 0036190033 scopus 로고    scopus 로고
    • Neurostimulation systems for deep brain stimulation: in vitro evaluation of magnetic resonance imaging-related heating at 1.5 tesla
    • Rezai A.R., Finelli D., Nyenhuis J.A., et al. Neurostimulation systems for deep brain stimulation: in vitro evaluation of magnetic resonance imaging-related heating at 1.5 tesla. J Magn Reson Imaging 2002, 15:241-250.
    • (2002) J Magn Reson Imaging , vol.15 , pp. 241-250
    • Rezai, A.R.1    Finelli, D.2    Nyenhuis, J.A.3
  • 7
    • 1942533027 scopus 로고    scopus 로고
    • Neurostimulation system used for deep brain stimulation (DBS): MR safety issues and implications of failing to follow safety recommendations
    • Rezai A.R., Phillips M., Baker K.B., et al. Neurostimulation system used for deep brain stimulation (DBS): MR safety issues and implications of failing to follow safety recommendations. Invest Radiol 2004, 39:300-303.
    • (2004) Invest Radiol , vol.39 , pp. 300-303
    • Rezai, A.R.1    Phillips, M.2    Baker, K.B.3
  • 8
    • 27644532020 scopus 로고    scopus 로고
    • Is magnetic resonance imaging safe for patients with neurostimulation systems used for deep brain stimulation?
    • Rezai A.R., Baker K.B., Tkach J.A., et al. Is magnetic resonance imaging safe for patients with neurostimulation systems used for deep brain stimulation?. Neurosurgery 2005, 57:1056-1062.
    • (2005) Neurosurgery , vol.57 , pp. 1056-1062
    • Rezai, A.R.1    Baker, K.B.2    Tkach, J.A.3
  • 9
    • 0141455180 scopus 로고    scopus 로고
    • Transient dystonia following magnetic resonance imaging in a patient with deep brain stimulation electrodes for the treatment of Parkinson disease. Case report
    • Spiegel J., Fuss G., Backens M., Reith W., et al. Transient dystonia following magnetic resonance imaging in a patient with deep brain stimulation electrodes for the treatment of Parkinson disease. Case report. J Neurosurg 2003, 99:772-774.
    • (2003) J Neurosurg , vol.99 , pp. 772-774
    • Spiegel, J.1    Fuss, G.2    Backens, M.3    Reith, W.4