메뉴 건너뛰기




Volumn 104, Issue 3, 2013, Pages 188-193

The stable microbubble test for determining continuous positive airway pressure (CPAP) success in very preterm infants receiving nasal CPAP from birth

Author keywords

Continuous positive airway pressure; Microbubble test; Respiratory distress; Ventilation; Very preterm infants

Indexed keywords

CORTICOSTEROID;

EID: 84885005608     PISSN: 16617800     EISSN: 16617819     Source Type: Journal    
DOI: 10.1159/000353363     Document Type: Article
Times cited : (24)

References (20)
  • 3
    • 80051796763 scopus 로고    scopus 로고
    • Predictors of early nasal CPAP failure and effects of various intubation criteria on the rate of mechanical ventilation in preterm infants of <29 weeks' gestational age
    • Fuchs H, Lindner W, Leiprecht A, Mendler MR, Hummler HD: Predictors of early nasal CPAP failure and effects of various intubation criteria on the rate of mechanical ventilation in preterm infants of <29 weeks' gestational age. Arch Dis Child Fetal Neonatal Ed 2011; 96:F343-F347.
    • (2011) Arch Dis Child Fetal Neonatal Ed , vol.96 , pp. F343-F347
    • Fuchs, H.1    Lindner, W.2    Leiprecht, A.3    Mendler, M.R.4    Hummler, H.D.5
  • 5
    • 84858082336 scopus 로고    scopus 로고
    • Early prediction of nasal continuous positive airway pressure failure in preterm infants less than 30 weeks' gestation
    • De Jaegere AP, van der Lee JH, Cante C, van Kaam AH: Early prediction of nasal continuous positive airway pressure failure in preterm infants less than 30 weeks' gestation. Acta Paediatr 2012; 101: 374-379.
    • (2012) Acta Paediatr , vol.101 , pp. 374-379
    • De Jaegere, A.P.1    Van Der Lee, J.H.2    Cante, C.3    Van Kaam, A.H.4
  • 6
    • 84861924011 scopus 로고    scopus 로고
    • Prophylactic versus selective use of surfactant in preventing morbidity and mortality in preterm infants
    • Rojas-Reyes MX, Morley CJ, Soll R: Prophylactic versus selective use of surfactant in preventing morbidity and mortality in preterm infants. Cochrane Database Syst Rev 2012; 3:CD000510.
    • (2012) Cochrane Database Syst Rev , vol.3 , pp. CD000510
    • Rojas-Reyes, M.X.1    Morley, C.J.2    Soll, R.3
  • 8
    • 0027392341 scopus 로고
    • Stable microbubble test for predicting the risk of respiratory distress syndrome. I. Comparisons with other predictors of fetal lung maturity in amniotic fluid
    • Chida S, Fujiwara T: Stable microbubble test for predicting the risk of respiratory distress syndrome. I. Comparisons with other predictors of fetal lung maturity in amniotic fluid. Eur J Pediatr 1993; 152: 148-151.
    • (1993) Eur J Pediatr , vol.152 , pp. 148-151
    • Chida, S.1    Fujiwara, T.2
  • 9
    • 0035690551 scopus 로고    scopus 로고
    • Computerized image analysis of bubbles in gastric aspirate for prediction of respiratory distress syndrome
    • Fiori HH, Linderholm B, Fiori RM, Robertson B: Computerized image analysis of bubbles in gastric aspirate for prediction of respiratory distress syndrome. Acta Paediatr 2001; 90: 1402-1404.
    • (2001) Acta Paediatr , vol.90 , pp. 1402-1404
    • Fiori, H.H.1    Linderholm, B.2    Fiori, R.M.3    Robertson, B.4
  • 10
    • 0031963186 scopus 로고    scopus 로고
    • The stable microbubble test on tracheal aspirate samples from newborn babies for diagnosis of surfactant deficiency and/or surfactant malfunction
    • Friedrich W, Haufe M, Schmalisch G, Wauer RR: The stable microbubble test on tracheal aspirate samples from newborn babies for diagnosis of surfactant deficiency and/or surfactant malfunction. Biol Neonate 1998; 73: 10-18.
    • (1998) Biol Neonate , vol.73 , pp. 10-18
    • Friedrich, W.1    Haufe, M.2    Schmalisch, G.3    Wauer, R.R.4
  • 11
    • 0031032560 scopus 로고    scopus 로고
    • Surfactant proteins and stable microbubbles in tracheal aspirates of infants with respiratory distress syndrome: Relation to the degree of respiratory failure and response to exogenous surfactant
    • Chida S, Fujiwara T, Konishi M, Shimada S, Takahashi A: Surfactant proteins and stable microbubbles in tracheal aspirates of infants with respiratory distress syndrome: relation to the degree of respiratory failure and response to exogenous surfactant. Eur J Pediatr 1997; 156: 131-138.
    • (1997) Eur J Pediatr , vol.156 , pp. 131-138
    • Chida, S.1    Fujiwara, T.2    Konishi, M.3    Shimada, S.4    Takahashi, A.5
  • 12
    • 14044276260 scopus 로고    scopus 로고
    • Stable microbubble test on tracheal aspirate for the diagnosis of respiratory distress syndrome
    • Eckert SE, Fiori HH, Luz JH, Fiori RM: Stable microbubble test on tracheal aspirate for the diagnosis of respiratory distress syndrome. Biol Neonate 2005; 87: 140-144.
    • (2005) Biol Neonate , vol.87 , pp. 140-144
    • Eckert, S.E.1    Fiori, H.H.2    Luz, J.H.3    Fiori, R.M.4
  • 13
    • 0034266037 scopus 로고    scopus 로고
    • Targeted early rescue surfactant in ventilated preterm infants using the click test
    • Osborn DA, Jeffery HE, Bredemeyer SL, Polverino JM, Reid S: Targeted early rescue surfactant in ventilated preterm infants using the click test. Pediatrics 2000; 106:E30.
    • (2000) Pediatrics , vol.106 , pp. E30
    • Osborn, D.A.1    Jeffery, H.E.2    Bredemeyer, S.L.3    Polverino, J.M.4    Reid, S.5
  • 14
    • 0031816176 scopus 로고    scopus 로고
    • Prediction of idiopathic respiratory distress syndrome by the stable microbubble test on gastric aspirate
    • Teeratakulpisarn J, Taksaphan S, Pengsaa K, Wiangnon S, Kosuwon W: Prediction of idiopathic respiratory distress syndrome by the stable microbubble test on gastric aspirate. Pediatr Pulmonol 1998; 25: 383-389.
    • (1998) Pediatr Pulmonol , vol.25 , pp. 383-389
    • Teeratakulpisarn, J.1    Taksaphan, S.2    Pengsaa, K.3    Wiangnon, S.4    Kosuwon, W.5
  • 15
    • 0347594156 scopus 로고    scopus 로고
    • Stable microbubble test and click test to predict respiratory distress syndrome in preterm infants not requiring ventilation at birth
    • Fiori HH, Varela I, Justo AL, Fiori RM: Stable microbubble test and click test to predict respiratory distress syndrome in preterm infants not requiring ventilation at birth. J Perinat Med 2003; 31: 509-514.
    • (2003) J Perinat Med , vol.31 , pp. 509-514
    • Fiori, H.H.1    Varela, I.2    Justo, A.L.3    Fiori, R.M.4
  • 16
    • 77949479980 scopus 로고    scopus 로고
    • Lamellar body count and stable microbubble test on gastric aspirates from preterm infants for the diagnosis of respiratory distress syndrome
    • Daniel IW, Fiori HH, Piva JP, Munhoz TP, Nectoux AV, Fiori RM: Lamellar body count and stable microbubble test on gastric aspirates from preterm infants for the diagnosis of respiratory distress syndrome. Neonatology 2010; 98: 150-155.
    • (2010) Neonatology , vol.98 , pp. 150-155
    • Daniel, I.W.1    Fiori, H.H.2    Piva, J.P.3    Munhoz, T.P.4    Nectoux, A.V.5    Fiori, R.M.6
  • 18
    • 79961097548 scopus 로고    scopus 로고
    • Clinical prediction score for nasal CPAP failure in pre-term VLBW neonates with early onset respiratory distress
    • Pillai MS, Sankar MJ, Mani K, Agarwal R, Paul VK, Deorari AK: Clinical prediction score for nasal CPAP failure in pre-term VLBW neonates with early onset respiratory distress. J Trop Pediatr 2011; 57: 274-279.
    • (2011) J Trop Pediatr , vol.57 , pp. 274-279
    • Pillai, M.S.1    Sankar, M.J.2    Mani, K.3    Agarwal, R.4    Paul, V.K.5    Deorari, A.K.6
  • 20
    • 3543001123 scopus 로고    scopus 로고
    • Evaluation of surfactant function at birth determined by the stable microbubble test in term and near term infants with respiratory distress
    • Fiori HH, Henn R, Baldisserotto M, Bica IG, Fiori RM: Evaluation of surfactant function at birth determined by the stable microbubble test in term and near term infants with respiratory distress. Eur J Pediatr 2004; 163: 443-448.
    • (2004) Eur J Pediatr , vol.163 , pp. 443-448
    • Fiori, H.H.1    Henn, R.2    Baldisserotto, M.3    Bica, I.G.4    Fiori, R.M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.