메뉴 건너뛰기




Volumn 27, Issue 7, 2013, Pages 2312-2320

Blunt versus bladed trocars in laparoscopic surgery: A systematic review and meta-analysis of randomized trials

Author keywords

Bladed; Blunt; Cutting; Laparoscopy; Radial; Trocar

Indexed keywords

ABDOMINAL BLEEDING; ADULT; AGED; BLADED TROCAR; BLUNT TROCAR; CLINICAL EVALUATION; COMPARATIVE EFFECTIVENESS; CONTROLLED STUDY; EQUIPMENT FAILURE; FEMALE; HUMAN; INTERMETHOD COMPARISON; JADAD SCORE; LAPAROSCOPIC SURGERY; MAJOR CLINICAL STUDY; MALE; MEDICAL DEVICE COMPLICATION; META ANALYSIS; MORBIDITY; OUTCOME ASSESSMENT; PRIORITY JOURNAL; RANDOMIZED CONTROLLED TRIAL (TOPIC); REVIEW; RISK ASSESSMENT; RISK FACTOR; SCORING SYSTEM; SURGICAL RISK; SYSTEMATIC REVIEW; TROCAR; VISCERAL INJURY;

EID: 84884906865     PISSN: 09302794     EISSN: 14322218     Source Type: Journal    
DOI: 10.1007/s00464-013-2793-y     Document Type: Review
Times cited : (33)

References (26)
  • 1
    • 34447312236 scopus 로고    scopus 로고
    • Laparoscopic entry: A review of techniques, technologies, and complications
    • The Society of Obstetricians and Gynaecologists of Canada 17493376
    • Vilos GA, Ternamian A, Dempster J, Laberge PY, The Society of Obstetricians and Gynaecologists of Canada (2007) Laparoscopic entry: a review of techniques, technologies, and complications. J Obstet Gynaecol Can 29:433-465
    • (2007) J Obstet Gynaecol Can , vol.29 , pp. 433-465
    • Vilos, G.A.1    Ternamian, A.2    Dempster, J.3    Laberge, P.Y.4
  • 2
    • 22144491929 scopus 로고    scopus 로고
    • Trocar-associated injuries and fatalities: An analysis of 1399 reports to the FDA
    • 16036187 10.1016/j.jmig.2005.05.008
    • Fuller J, Ashar BS, Carey-Corrado J (2005) Trocar-associated injuries and fatalities: an analysis of 1399 reports to the FDA. J Minim Invasive Gynecol 12:302-307
    • (2005) J Minim Invasive Gynecol , vol.12 , pp. 302-307
    • Fuller, J.1    Ashar, B.S.2    Carey-Corrado, J.3
  • 3
    • 16844373055 scopus 로고    scopus 로고
    • Bleeding remains a major complication during laparoscopic surgery: Analysis of the SALTS database
    • 15700192 10.1007/s00423-004-0538-z
    • Opitz I, Gantert W, Giger U, Kocher T, Krähenbühl L (2005) Bleeding remains a major complication during laparoscopic surgery: analysis of the SALTS database. Langenbecks Arch Surg 390:128-133
    • (2005) Langenbecks Arch Surg , vol.390 , pp. 128-133
    • Opitz, I.1    Gantert, W.2    Giger, U.3    Kocher, T.4    Krähenbühl, L.5
  • 4
    • 0032933134 scopus 로고    scopus 로고
    • Laparoscopic surgery complications associated with trocar tip design: Review of literature and own results
    • 10235350 10.1089/lap.1999.9.135 1:STN:280:DyaK1M3kvFChuw%3D%3D
    • Leibl BJ, Schmedt CG, Schwarz J, Kraft K, Bittner R (1999) Laparoscopic surgery complications associated with trocar tip design: review of literature and own results. J Laparoendosc Adv Surg Tech A 9:135-140
    • (1999) J Laparoendosc Adv Surg Tech A , vol.9 , pp. 135-140
    • Leibl, B.J.1    Schmedt, C.G.2    Schwarz, J.3    Kraft, K.4    Bittner, R.5
  • 5
    • 77955454925 scopus 로고    scopus 로고
    • Application of energy-based technologies and topical hemostatic agents in the management of surgical hemostasis
    • 20643029 10.2310/6670.2010.00015
    • Sileshi B, Achneck H, Ma L, Lawson JH (2010) Application of energy-based technologies and topical hemostatic agents in the management of surgical hemostasis. Vascular 18:197-204
    • (2010) Vascular , vol.18 , pp. 197-204
    • Sileshi, B.1    Achneck, H.2    Ma, L.3    Lawson, J.H.4
  • 6
    • 0034985909 scopus 로고    scopus 로고
    • Trocar injuries in laparoscopic surgery
    • 11400960 10.1016/S1072-7515(01)00913-9 1:STN:280:DC%2BD3MzjtlyjtA%3D%3D
    • Bhoyrul S, Vierra MA, Nezhat CR, Krummel TM, Way LW (2001) Trocar injuries in laparoscopic surgery. J Am Coll Surg 192:677-683
    • (2001) J Am Coll Surg , vol.192 , pp. 677-683
    • Bhoyrul, S.1    Vierra, M.A.2    Nezhat, C.R.3    Krummel, T.M.4    Way, L.W.5
  • 7
    • 0033029290 scopus 로고    scopus 로고
    • Entry force and intra-abdominal pressure associated with six laparoscopic trocar-cannula systems: A randomized comparison
    • 10389723 10.1016/S0029-7844(99)00288-4 1:STN:280:DyaK1Mzhs1Grtw%3D%3D
    • Tarnay CM, Glass KB, Munro MG (1999) Entry force and intra-abdominal pressure associated with six laparoscopic trocar-cannula systems: a randomized comparison. Obstet Gynecol 94:83-88
    • (1999) Obstet Gynecol , vol.94 , pp. 83-88
    • Tarnay, C.M.1    Glass, K.B.2    Munro, M.G.3
  • 8
    • 0030195345 scopus 로고    scopus 로고
    • Radially expanding dilatation. A superior method of laparoscopic trocar access
    • 8662440 10.1007/BF00193057 1:STN:280:DyaK283otFKisA%3D%3D
    • Bhoyrul S, Mori T, Way LW (1996) Radially expanding dilatation. A superior method of laparoscopic trocar access. Surg Endosc 10:775-778
    • (1996) Surg Endosc , vol.10 , pp. 775-778
    • Bhoyrul, S.1    Mori, T.2    Way, L.W.3
  • 9
    • 0029737624 scopus 로고    scopus 로고
    • A new, radially expanding access system for laparoscopic procedures versus conventional cannulas
    • 9050697 10.1016/S1074-3804(05)80175-6 1:STN:280:DyaK2s3jvVenuw%3D%3D
    • Turner DJ (1996) A new, radially expanding access system for laparoscopic procedures versus conventional cannulas. J Am Assoc Gynecol Laparosc 3:609-615
    • (1996) J Am Assoc Gynecol Laparosc , vol.3 , pp. 609-615
    • Turner, D.J.1
  • 11
    • 68549101842 scopus 로고    scopus 로고
    • The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: Explanation and elaboration
    • 19622552 10.1136/bmj.b2700
    • Liberati A, Altman DG, Tetzlaff J, Mulrow C, Gøtzsche PC, Ioannidis JP, Clarke M, Devereaux PJ, Kleijnen J, Moher D (2009) The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: explanation and elaboration. BMJ 339:b2700
    • (2009) BMJ , vol.339 , pp. 2700
    • Liberati, A.1    Altman, D.G.2    Tetzlaff, J.3    Mulrow, C.4    Gøtzsche, P.C.5    Ioannidis, J.P.6    Clarke, M.7    Devereaux, P.J.8    Kleijnen, J.9    Moher, D.10
  • 12
    • 34748855649 scopus 로고    scopus 로고
    • Prospective randomized comparison of cutting and dilating disposable trocars for access during laparoscopic renal surgery
    • 17761080
    • Venkatesh R, Sundaram CP, Figenshau RS, Yan Y, Andriole GL, Clayman RV, Landman J (2007) Prospective randomized comparison of cutting and dilating disposable trocars for access during laparoscopic renal surgery. JSLS 11:198-203
    • (2007) JSLS , vol.11 , pp. 198-203
    • Venkatesh, R.1    Sundaram, C.P.2    Figenshau, R.S.3    Yan, Y.4    Andriole, G.L.5    Clayman, R.V.6    Landman, J.7
  • 13
    • 35448962537 scopus 로고    scopus 로고
    • Randomized clinical trial comparing radially expanding trocars with conventional cutting trocars for the effects on pain after laparoscopic cholecystectomy
    • 17705082 10.1007/s00464-007-9517-0 1:STN:280:DC%2BD2snhslSrtQ%3D%3D
    • Bisgaard T, Jakobsen HL, Jacobsen B, Olsen SD, Rosenberg J (2007) Randomized clinical trial comparing radially expanding trocars with conventional cutting trocars for the effects on pain after laparoscopic cholecystectomy. Surg Endosc 21:2012-2016
    • (2007) Surg Endosc , vol.21 , pp. 2012-2016
    • Bisgaard, T.1    Jakobsen, H.L.2    Jacobsen, B.3    Olsen, S.D.4    Rosenberg, J.5
  • 14
    • 34447313434 scopus 로고    scopus 로고
    • Fixity of ports to the abdominal wall during laparoscopic surgery: A randomized comparison of cutting versus blunt trocars
    • 17287914 10.1007/s00464-006-9142-3 1:STN:280:DC%2BD2svgtlGmtw%3D%3D
    • Hamade AM, Issa ME, Haylett KR, Ammori BJ (2007) Fixity of ports to the abdominal wall during laparoscopic surgery: a randomized comparison of cutting versus blunt trocars. Surg Endosc 21:965-969
    • (2007) Surg Endosc , vol.21 , pp. 965-969
    • Hamade, A.M.1    Issa, M.E.2    Haylett, K.R.3    Ammori, B.J.4
  • 15
    • 33947145594 scopus 로고    scopus 로고
    • Comparative analysis of 5 mm trocars: Dilating tip versus non-shielded bladed
    • 17368253 10.1016/j.jmig.2006.09.014
    • Stepanian AA, Winer WK, Isler CM, Lyons TL (2007) Comparative analysis of 5 mm trocars: dilating tip versus non-shielded bladed. J Minim Invasive Gynecol 14:176-183
    • (2007) J Minim Invasive Gynecol , vol.14 , pp. 176-183
    • Stepanian, A.A.1    Winer, W.K.2    Isler, C.M.3    Lyons, T.L.4
  • 16
    • 0035126201 scopus 로고    scopus 로고
    • Randomized double-masked comparison of radially expanding access device and conventional cutting tip trocar in laparoscopy
    • 11239652 10.1016/S0029-7844(00)01156-X 1:STN:280:DC%2BD3M7pslKgtg%3D%3D
    • Yim SF, Yuen PM (2001) Randomized double-masked comparison of radially expanding access device and conventional cutting tip trocar in laparoscopy. Obstet Gynecol 97:435-438
    • (2001) Obstet Gynecol , vol.97 , pp. 435-438
    • Yim, S.F.1    Yuen, P.M.2
  • 17
    • 0034222784 scopus 로고    scopus 로고
    • A randomized prospective study of radially expanding trocars in laparoscopic surgery
    • 11058851 10.1016/S1091-255X(00)80018-9 1:STN:280:DC%2BD3M%2FkvVyksQ%3D%3D
    • Bhoyrul S, Payne J, Steffes B, Swanstrom L, Way LW (2000) A randomized prospective study of radially expanding trocars in laparoscopic surgery. J Gastrointest Surg 4:392-397
    • (2000) J Gastrointest Surg , vol.4 , pp. 392-397
    • Bhoyrul, S.1    Payne, J.2    Steffes, B.3    Swanstrom, L.4    Way, L.W.5
  • 18
    • 0033785874 scopus 로고    scopus 로고
    • Radially expanding trocar: A less painful alternative for laparoscopic surgery
    • 11071407 10.1089/lap.2000.10.269 1:STN:280:DC%2BD3crht12jtA%3D%3D
    • Lam TY, Lee SW, So HS, Kwok SP (2000) Radially expanding trocar: a less painful alternative for laparoscopic surgery. J Laparoendosc Adv Surg Tech A 10:269-273
    • (2000) J Laparoendosc Adv Surg Tech A , vol.10 , pp. 269-273
    • Lam, T.Y.1    Lee, S.W.2    So, H.S.3    Kwok, S.P.4
  • 19
    • 0034471637 scopus 로고    scopus 로고
    • Investigation of the effectiveness of the radially-expanding needle system, in contrast to the cutting trocar in enhancing patient recovery
    • 10.3109/13645700009093715
    • Mettler L, Maher P (2000) Investigation of the effectiveness of the radially-expanding needle system, in contrast to the cutting trocar in enhancing patient recovery. Minim Invasive Ther Allied Technol 9:397-401
    • (2000) Minim Invasive Ther Allied Technol , vol.9 , pp. 397-401
    • Mettler, L.1    Maher, P.2
  • 20
    • 0033656832 scopus 로고    scopus 로고
    • Randomized trial comparing a radially expandable needle system with cutting trocars
    • 10772522 1:STN:280:DC%2BD3c3jtlCktA%3D%3D
    • Feste JR, Bojahr B, Turner DJ (2000) Randomized trial comparing a radially expandable needle system with cutting trocars. JSLS 4:11-15
    • (2000) JSLS , vol.4 , pp. 11-15
    • Feste, J.R.1    Bojahr, B.2    Turner, D.J.3
  • 21
    • 77953421719 scopus 로고    scopus 로고
    • Entry complications in laparoscopic surgery
    • 22442503 10.4103/0974-1216.51902 1:STN:280:DC%2BC38vovFygtw%3D%3D
    • Krishnakumar S, Tambe P (2009) Entry complications in laparoscopic surgery. J Gynecol Endosc Surg 1:4-11
    • (2009) J Gynecol Endosc Surg , vol.1 , pp. 4-11
    • Krishnakumar, S.1    Tambe, P.2
  • 22
    • 0347479279 scopus 로고    scopus 로고
    • Aortic injury during initial blunt trocar laparoscopic access for renal surgery
    • 14665922 10.1097/01.ju.0000099759.92878.3e
    • Orvieto M, Breyer B, Sokoloff M, Shalhav AH (2004) Aortic injury during initial blunt trocar laparoscopic access for renal surgery. J Urol 171:349-350
    • (2004) J Urol , vol.171 , pp. 349-350
    • Orvieto, M.1    Breyer, B.2    Sokoloff, M.3    Shalhav, A.H.4
  • 23
    • 0034838035 scopus 로고    scopus 로고
    • Blunt hasson trocar injury: Long intra-abdominal trocar and lean patient-a dangerous combination
    • 11569519 10.1089/109264201750539817 1:STN:280:DC%2BD3MritFCrtw%3D%3D
    • Voitk A, Rizoli S (2001) Blunt hasson trocar injury: long intra-abdominal trocar and lean patient-a dangerous combination. J Laparoendosc Adv Surg Tech A 11:259-262
    • (2001) J Laparoendosc Adv Surg Tech A , vol.11 , pp. 259-262
    • Voitk, A.1    Rizoli, S.2
  • 24
    • 2342455219 scopus 로고    scopus 로고
    • The impact of trocar-cannula design and simulated operative manipulation on incisional characteristics: A randomized trial
    • 15051559 10.1097/01.AOG.0000120144.85187.61
    • Munro MG, Tarnay CM (2004) The impact of trocar-cannula design and simulated operative manipulation on incisional characteristics: a randomized trial. Obstet Gynecol 103:681-685
    • (2004) Obstet Gynecol , vol.103 , pp. 681-685
    • Munro, M.G.1    Tarnay, C.M.2
  • 25
    • 35348823690 scopus 로고    scopus 로고
    • Incisional hernia in a 12 mm non-bladed trocar site following laparoscopic nephrectomy
    • 17940363 10.1159/000107963
    • Kouba EJ, Hubbard JS, Wallen E, Pruthi RS (2007) Incisional hernia in a 12 mm non-bladed trocar site following laparoscopic nephrectomy. Urol Int 79:276-279
    • (2007) Urol Int , vol.79 , pp. 276-279
    • Kouba, E.J.1    Hubbard, J.S.2    Wallen, E.3    Pruthi, R.S.4
  • 26
    • 84857038522 scopus 로고    scopus 로고
    • Radially expanding laparoscopic trocar ports significantly reduce postoperative pain in all age groups
    • 21993944 10.1007/s00464-011-1963-z
    • Mordecai SC, Warren OW, Warren SJ (2012) Radially expanding laparoscopic trocar ports significantly reduce postoperative pain in all age groups. Surg Endosc 26:843-846
    • (2012) Surg Endosc , vol.26 , pp. 843-846
    • Mordecai, S.C.1    Warren, O.W.2    Warren, S.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.