메뉴 건너뛰기




Volumn 127, Issue 2, 2013, Pages 79-87

Guidelines for clinical electroretinography in the dog: 2012 update

Author keywords

Canine; Cones; ERG; Protocol; Retina; Rods; Standard

Indexed keywords

DOG; ELECTRODE; ELECTRORETINOGRAPHY; HUMAN; LIGHT; NONHUMAN; PRACTICE GUIDELINE; PRIORITY JOURNAL; RETINA DEGENERATION; RETINA DISEASE; RETINA DYSTROPHY; REVIEW; STIMULUS RESPONSE;

EID: 84884905484     PISSN: 00124486     EISSN: 15732622     Source Type: Journal    
DOI: 10.1007/s10633-013-9388-8     Document Type: Review
Times cited : (69)

References (11)
  • 1
    • 84884906208 scopus 로고
    • Archiv für Anatomie und Physiologie, Leipzig, Physiologische Abteilung
    • Piper H (1911) Über die Netzhautströme. Archiv für Anatomie und Physiologie, Leipzig, Physiologische Abteilung 85-132
    • (1911) Über Die Netzhautströme , pp. 85-132
    • Piper, H.1
  • 5
    • 75749112852 scopus 로고    scopus 로고
    • Electrodiagnostic examination
    • K.N. Gelatt (eds) 4 1 Blackwell Publishing Oxford
    • Ekesten B (2007) Electrodiagnostic examination. In: Gelatt KN (ed) Veterinary ophthalmology, vol 1, 4th edn. Blackwell Publishing, Ames, pp 520-535
    • (2007) Veterinary Ophthalmology , pp. 520-535
    • Ekesten, B.1
  • 6
    • 0014837064 scopus 로고
    • Electroretinography: Some basic principles
    • 5311619 1:STN:280:DyaE3c3osVeluw%3D%3D
    • Gouras P (1970) Electroretinography: some basic principles. Invest Ophthalmol 9:557-569
    • (1970) Invest Ophthalmol , vol.9 , pp. 557-569
    • Gouras, P.1
  • 7
    • 0029121753 scopus 로고
    • Clinical electroretinography in the dog with ganzfeld stimulation: A practical method of examining rod and cone function
    • 8846736 10.1007/BF01203863
    • Narfström K, Andersson BE, Andreasson S, Gouras P (1995) Clinical electroretinography in the dog with ganzfeld stimulation: a practical method of examining rod and cone function. Doc Ophthalmol 90:279-290
    • (1995) Doc Ophthalmol , vol.90 , pp. 279-290
    • Narfström, K.1    Andersson, B.E.2    Andreasson, S.3    Gouras, P.4
  • 8
    • 27844582975 scopus 로고    scopus 로고
    • Assessment of the dark-adaptation time required for recovery of electroretinographic responses in dogs after fundus photography and indirect ophthalmoscopy
    • 16273914 10.2460/ajvr.2005.66.1798
    • Tuntivanich N, Mentzer L, Eifler DM, Montiani-Ferreira F, Forcier JQ, Johnson CA, Petersen-Jones SM (2005) Assessment of the dark-adaptation time required for recovery of electroretinographic responses in dogs after fundus photography and indirect ophthalmoscopy. Am J Vet Res 66(10):1798-1804
    • (2005) Am J Vet Res , vol.66 , Issue.10 , pp. 1798-1804
    • Tuntivanich, N.1    Mentzer, L.2    Eifler, D.M.3    Montiani-Ferreira, F.4    Forcier, J.Q.5    Johnson, C.A.6    Petersen-Jones, S.M.7
  • 9
    • 59049100882 scopus 로고    scopus 로고
    • ISCEV standard for full-field clinical electroretinography (2008 update)
    • 19030905 10.1007/s10633-008-9155-4 1:STN:280:DC%2BD1M%2FnvVGjsQ%3D%3D
    • Marmor MF, Fulton AB, Holder GE, Miyake Y, Brigell M, Bach M (2009) ISCEV standard for full-field clinical electroretinography (2008 update). Doc Ophthalmol 118:69-77
    • (2009) Doc Ophthalmol , vol.118 , pp. 69-77
    • Marmor, M.F.1    Fulton, A.B.2    Holder, G.E.3    Miyake, Y.4    Brigell, M.5    Bach, M.6
  • 10
    • 0345331018 scopus 로고    scopus 로고
    • Guidelines for calibration of stimulus and recording parameters used in clinical electrophysiology of vision
    • 14661909 10.1023/A:1026244901657
    • Brigell M, Bach M, Barber C, Moskowitz A, Robson JG (2003) Guidelines for calibration of stimulus and recording parameters used in clinical electrophysiology of vision. Doc Ophthalmol 107:185-193
    • (2003) Doc Ophthalmol , vol.107 , pp. 185-193
    • Brigell, M.1    Bach, M.2    Barber, C.3    Moskowitz, A.4    Robson, J.G.5
  • 11
    • 33644752029 scopus 로고    scopus 로고
    • Influence of recording electrode type and reference electrode position on the canine electroretinogram
    • 16514491 10.1007/s10633-005-4517-7
    • Mentzer AE, Eifler DM, Montiani-Ferreira F, Tuntivanich N, Forcier JQ, Petersen-Jones SM (2005) Influence of recording electrode type and reference electrode position on the canine electroretinogram. Doc Ophthalmol 111(95-106):95-106
    • (2005) Doc Ophthalmol , vol.111 , Issue.95-106 , pp. 95-106
    • Mentzer, A.E.1    Eifler, D.M.2    Montiani-Ferreira, F.3    Tuntivanich, N.4    Forcier, J.Q.5    Petersen-Jones, S.M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.