메뉴 건너뛰기




Volumn 41, Issue 10, 2013, Pages 901-907

Cleaning assessment of disinfectant cleaning wipes on an external surface of a medical device contaminated with artificial blood or Streptococcus pneumoniae

Author keywords

Disinfection; Infection control; Medical equipment; Reprocessing

Indexed keywords

ADENOSINE TRIPHOSPHATE; ARTIFICIAL BLOOD; BACTERIAL PROTEIN; DISINFECTANT AGENT; HYPOCHLORITE SODIUM; PHTHALALDEHYDE;

EID: 84884901655     PISSN: 01966553     EISSN: 15273296     Source Type: Journal    
DOI: 10.1016/j.ajic.2013.01.029     Document Type: Article
Times cited : (29)

References (35)
  • 1
    • 84864941134 scopus 로고    scopus 로고
    • Preventing health care-associated infections
    • R.G. Hughes, Agency for Healthcare Research and Quality Rockville [MD]
    • A.S. Collins Preventing health care-associated infections R.G. Hughes, Patient safety and quality: an evidence-based handbook for nurses 2008 Agency for Healthcare Research and Quality Rockville [MD] 547 575
    • (2008) Patient Safety and Quality: An Evidence-based Handbook for Nurses , pp. 547-575
    • Collins, A.S.1
  • 2
    • 81055147687 scopus 로고    scopus 로고
    • Control of health-care-associated infections, 1961-2011
    • R.E. Dixon Control of health-care-associated infections, 1961-2011 Morb Mortal Wkly Suppl 60 2011 58 63
    • (2011) Morb Mortal Wkly Suppl , vol.60 , pp. 58-63
    • Dixon, R.E.1
  • 3
    • 70449633035 scopus 로고    scopus 로고
    • Economic burden of healthcare-associated infections: An American perspective
    • P.W. Stone Economic burden of healthcare-associated infections: an American perspective Expert Rev Pharmacoeconomics Outcomes Res 9 2009 417 422
    • (2009) Expert Rev Pharmacoeconomics Outcomes Res , vol.9 , pp. 417-422
    • Stone, P.W.1
  • 4
    • 0030203524 scopus 로고    scopus 로고
    • Selected aspects of the socioeconomic impact of nosocomial infections: Morbidity, mortality, cost, and prevention
    • W.R. Jarvis Selected aspects of the socioeconomic impact of nosocomial infections: morbidity, mortality, cost, and prevention Infect Control Hosp Epidemiol 17 1996 552 557 (Pubitemid 126481233)
    • (1996) Infection Control and Hospital Epidemiology , vol.17 , Issue.8 , pp. 552-557
    • Jarvis, W.R.1
  • 5
    • 14944340587 scopus 로고    scopus 로고
    • One-year mortality of bloodstream infection-associated sepsis and septic shock among patients presenting to a regional critical care system
    • DOI 10.1007/s00134-004-2544-6
    • K.B. Laupland, D.A. Zygun, C.J. Doig, S.M. Bagshaw, L.W. Svenson, and G.W. Fick One-year mortality of bloodstream infection-associated sepsis and septic shock among patients presenting to a regional critical care system Intensive Care Med 31 2005 213 219 (Pubitemid 40362269)
    • (2005) Intensive Care Medicine , vol.31 , Issue.2 , pp. 213-219
    • Laupland, K.B.1    Zygun, D.A.2    Doig, C.J.3    Bagshaw, S.M.4    Svenson, L.W.5    Fick, G.H.6
  • 8
    • 82955251087 scopus 로고    scopus 로고
    • Health care-associated infection outbreak investigations by the Centers for Disease Control and Prevention, 1946-2005
    • L.K. Archibald, and W.R. Jarvis Health care-associated infection outbreak investigations by the Centers for Disease Control and Prevention, 1946-2005 Am J Epidemiol 174 2011 S47 S64
    • (2011) Am J Epidemiol , vol.174
    • Archibald, L.K.1    Jarvis, W.R.2
  • 9
    • 84884901307 scopus 로고    scopus 로고
    • Cleaning reusable medical devices: A critical first step
    • The Clinical Issue 2007. Accessed December 12, 2012
    • Shoemake S, Stoessel K. Cleaning reusable medical devices: a critical first step. Kimberly Clark Knowledge Network. The Clinical Issue 2007. Available from: http://en.haiwatch.com/data/upload/tools/Cleaning-Reusable-Devices.pdf. Accessed December 12, 2012.
    • Kimberly Clark Knowledge Network
    • Shoemake, S.1    Stoessel, K.2
  • 12
    • 84857140311 scopus 로고    scopus 로고
    • Effect of surface coating and finish upon the cleanability of bed rails and the spread of Staphylococcus aureus
    • S. Ali, G. Moore, and A.P.R. Wilson Effect of surface coating and finish upon the cleanability of bed rails and the spread of Staphylococcus aureus J Hosp Infect 80 2012 192 198
    • (2012) J Hosp Infect , vol.80 , pp. 192-198
    • Ali, S.1    Moore, G.2    Wilson, A.P.R.3
  • 13
    • 84884908213 scopus 로고    scopus 로고
    • United States Food and Drug Administration. Accessed December 12, 2012
    • United States Food and Drug Administration. FDA safety communication: ongoing safety review of arthroscopic shavers. Available from: http://www.fda.gov/MedicalDevices/Safety/AlertsandNotices/ucm170639.htm. Accessed December 12, 2012.
    • FDA Safety Communication: Ongoing Safety Review of Arthroscopic Shavers
  • 15
    • 84863013247 scopus 로고    scopus 로고
    • Effectiveness of bacterial disinfectants on surfaces of mechanical ventilator systems
    • Y.S. Sui, G.H. Wan, Y.W. Chen, H.L. Ku, L.P. Li, and C.H. Liu Effectiveness of bacterial disinfectants on surfaces of mechanical ventilator systems Respir Care 57 2012 250 256
    • (2012) Respir Care , vol.57 , pp. 250-256
    • Sui, Y.S.1    Wan, G.H.2    Chen, Y.W.3    Ku, H.L.4    Li, L.P.5    Liu, C.H.6
  • 17
    • 0030018125 scopus 로고    scopus 로고
    • Pseudomonas aeruginosa outbreak associated with a contaminated blood-gas analyser in a neonatal intensive care unit
    • DOI 10.1016/S0195-6701(96)90099-7
    • S.M. Garland, S. Mackay, S. Tabrizi, and S. Jacobs Pseudomonas aeruginosa outbreak associated with a contaminated blood-gas analyzer in a neonatal intensive care unit J Hosp Infect 33 1996 145 151 (Pubitemid 26257740)
    • (1996) Journal of Hospital Infection , vol.33 , Issue.2 , pp. 145-151
    • Garland, S.M.1    Mackay, S.2    Tabrizi, S.3    Jacobs, S.4
  • 18
    • 0033960974 scopus 로고    scopus 로고
    • Detection of pathogen transmission in neonatal nurseries using DNA markers as surrogate indicators
    • D.G. Oelberg, S.E. Joyner, X. Jiang, D. Laborde, M.P. Islam, and L.K. Pickering Detection of pathogen transmission in neonatal nurseries using DNA markers as surrogate indicators Pediatrics 105 2000 311 315 (Pubitemid 30078669)
    • (2000) Pediatrics , vol.105 , Issue.2 , pp. 311-315
    • Oelberg, D.G.1    Joyner, S.E.2    Jiang, X.3    Laborde, D.4    Islam, M.P.5    Pickering, L.K.6
  • 19
    • 0001342521 scopus 로고    scopus 로고
    • Standardized test soil blood 1: Composition, preparation, application
    • M. Pfeifer Standardized test soil blood 1: composition, preparation, application Zentral Sterilisation 6 1998 381 385
    • (1998) Zentral Sterilisation , vol.6 , pp. 381-385
    • Pfeifer, M.1
  • 20
    • 33947230109 scopus 로고    scopus 로고
    • Sensitivität von nachweismethoden zur beurteilung der restkontamination chirurgischer instrumente nach der aufbereitung
    • T. Friedrich, K. Roth, J. Gauer, and P. Heeg Sensitivity of detection methods for assessment of residual contamination on reprocessed surgical instruments Zentral Sterilisation 15 2007 29 38 (Pubitemid 46422809)
    • (2007) Zentralsterilisation - Central Service , vol.15 , Issue.1 , pp. 29-38
    • Friedrich, T.1    Roth, K.2    Gauer, J.3    Heeg, P.4
  • 21
    • 34548319481 scopus 로고    scopus 로고
    • A designed experiment for evaluation of the OPA method for cleaning studies of medical devices
    • DOI 10.2345/0899-8205(2007)41[324:ADEFEO]2.0.CO;2
    • P.J. McCormick, J.J. Kaiser, M.J. Schoene, D.L. Shlatz, and S.E. Norton A designed experiment for evaluation of the OPA method for cleaning studies of medical devices Biomed Instrum Technol 41 2007 324 331 (Pubitemid 47344296)
    • (2007) Biomedical Instrumentation and Technology , vol.41 , Issue.4 , pp. 324-331
    • McCormick, P.J.1    Kaiser, J.J.2    Schoene, M.J.3    Shlatz, D.L.4    Norton, S.E.5
  • 23
    • 0028277324 scopus 로고
    • Blood contamination of anesthesia equipment and monitoring equipment
    • J.R. Hall Blood contamination of anesthesia equipment and monitoring equipment Anesth Analg 78 1994 1136 1139 (Pubitemid 24164362)
    • (1994) Anesthesia and Analgesia , vol.78 , Issue.6 , pp. 1136-1139
    • Hall, J.R.1
  • 28
    • 84885909911 scopus 로고    scopus 로고
    • United States Pharmacopeial Convention The United States Pharmacopeial Convention Rockville [MD] Chapter <1072>
    • United States Pharmacopeial Convention Disinfectants and antiseptics 2012 The United States Pharmacopeial Convention Rockville [MD] Chapter <1072>
    • (2012) Disinfectants and Antiseptics
  • 29
    • 79955493649 scopus 로고    scopus 로고
    • Evaluation of ATP bioluminescence assays for potential use in a hospital setting
    • Z.A. Aiken, M. Wilson, and J. Pratten Evaluation of ATP bioluminescence assays for potential use in a hospital setting Infect Control Hosp Epidemiol 32 2011 507 509
    • (2011) Infect Control Hosp Epidemiol , vol.32 , pp. 507-509
    • Aiken, Z.A.1    Wilson, M.2    Pratten, J.3
  • 30
    • 67651098977 scopus 로고    scopus 로고
    • Monitoring the effectiveness of hospital cleaning practices by use of an adenosine triphosphate bioluminescence assay
    • J.M. Boyce, N.L. Havill, D.G. Dumigan, M. Golebiewski, O. Blogun, and R. Rizvani Monitoring the effectiveness of hospital cleaning practices by use of an adenosine triphosphate bioluminescence assay Infect Control Hosp Epidemiol 30 2009 678 684
    • (2009) Infect Control Hosp Epidemiol , vol.30 , pp. 678-684
    • Boyce, J.M.1    Havill, N.L.2    Dumigan, D.G.3    Golebiewski, M.4    Blogun, O.5    Rizvani, R.6
  • 31
    • 77957118863 scopus 로고    scopus 로고
    • The use of adenosine triphosphate bioluminescence to assess the efficacy of a modified cleaning program implemented within an intensive care setting
    • G. Moore, D. Smyth, J. Singleton, and P. Wilson The use of adenosine triphosphate bioluminescence to assess the efficacy of a modified cleaning program implemented within an intensive care setting Am J Infect Control 38 2010 617 622
    • (2010) Am J Infect Control , vol.38 , pp. 617-622
    • Moore, G.1    Smyth, D.2    Singleton, J.3    Wilson, P.4
  • 33
    • 67349283333 scopus 로고    scopus 로고
    • Is it really clean? An evaluation of the efficacy of four methods for determining hospital cleanliness
    • O. Sherlock, N. O'Connell, E. Creamer, and H. Humphreys Is it really clean? An evaluation of the efficacy of four methods for determining hospital cleanliness J Hosp Infect 72 2009 140 146
    • (2009) J Hosp Infect , vol.72 , pp. 140-146
    • Sherlock, O.1    O'Connell, N.2    Creamer, E.3    Humphreys, H.4
  • 34
    • 84873056652 scopus 로고    scopus 로고
    • The uses and abuses of rapid bioluminescence-based ATP assays
    • G. Shama, and D.J. Malik The uses and abuses of rapid bioluminescence-based ATP assays Int J Hyg Environ Health 216 2013 115 125
    • (2013) Int J Hyg Environ Health , vol.216 , pp. 115-125
    • Shama, G.1    Malik, D.J.2
  • 35
    • 2142802650 scopus 로고    scopus 로고
    • Inoculum Size Influences Bacterial Cross Contamination between Surfaces
    • DOI 10.1128/AEM.69.12.7188-7193.2003
    • R. Montville, and D.W. Schaffner Inoculum size influences bacterial cross contamination between surfaces Appl Environ Microbiol 69 2003 7188 7193 (Pubitemid 38585368)
    • (2003) Applied and Environmental Microbiology , vol.69 , Issue.12 , pp. 7188-7193
    • Montville, R.1    Schaffner, D.W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.