메뉴 건너뛰기




Volumn 13, Issue 10, 2013, Pages 13063-13075

Fast and sensitive detection of Pb2+ in foods using disposable screen-printed electrode modified by reduced graphene oxide

Author keywords

Electrochemical deposition; Reduced graphene oxide (rGO); Screen printed carbon electrode (SPCE); Square wave voltammetry

Indexed keywords

ATOMIC ABSORPTION SPECTROMETRY; ELECTRODEPOSITION; ELECTRODES; GRAPHENE; REDUCTION; VOLTAMMETRY;

EID: 84884878504     PISSN: 14248220     EISSN: None     Source Type: Journal    
DOI: 10.3390/s131013063     Document Type: Article
Times cited : (70)

References (25)
  • 1
    • 37549058439 scopus 로고    scopus 로고
    • Fast and simultaneous detection of heavy metals using a simple and reliable microchip-electrochemistry route: An alternative approach to food analysis
    • Chailapakul, O.; Korsrisakul, S.; Siangproh, W.; Grudpan, K. Fast and simultaneous detection of heavy metals using a simple and reliable microchip-electrochemistry route: An alternative approach to food analysis. Talanta 2008, 74, 683-689.
    • (2008) Talanta , vol.74 , pp. 683-689
    • Chailapakul, O.1    Korsrisakul, S.2    Siangproh, W.3    Grudpan, K.4
  • 3
    • 0034864395 scopus 로고    scopus 로고
    • Anodic stripping voltammetry compared with graphite furnace atomic absorption spectrophotometry for blood lead analysis
    • Bannon, D.I.; Chisolm, J.J. Anodic stripping voltammetry compared with graphite furnace atomic absorption spectrophotometry for blood lead analysis. Clin. Chem. 2001, 47, 1703-1704.
    • (2001) Clin. Chem. , vol.47 , pp. 1703-1704
    • Bannon, D.I.1    Chisolm, J.J.2
  • 4
    • 84868705775 scopus 로고    scopus 로고
    • Determination of copper, zinc, lead and some biochemical parameters in fresh cow milk from different locations in Niger State, Nigeria
    • Jigam, A.A.; Dauda, B.E.N.; Jimoh, T.; Yusuf, H.N.; Umar, Z.T. Determination of copper, zinc, lead and some biochemical parameters in fresh cow milk from different locations in Niger State, Nigeria. Afr. J. Food Sci. 2011, 5, 156-160.
    • (2011) Afr. J. Food Sci. , vol.5 , pp. 156-160
    • Jigam, A.A.1    Dauda, B.E.N.2    Jimoh, T.3    Yusuf, H.N.4    Umar, Z.T.5
  • 5
    • 84885869872 scopus 로고    scopus 로고
    • Bioaccumulation of trace metals concentration in some vegetables grown near refuse and effluent dumpsites along Rumude-Doubeli bye-pass in Yola North, Adamawa State
    • Shagal, M.H.; Maina, H.M.; Donatus, R.B.; Tadzabia, K. Bioaccumulation of trace metals concentration in some vegetables grown near refuse and effluent dumpsites along Rumude-Doubeli bye-pass in Yola North, Adamawa State. Glob. Adv. Res. J. Environ. Sci. Toxicol. 2012, 1, 18-22.
    • (2012) Glob. Adv. Res. J. Environ. Sci. Toxicol. , vol.1 , pp. 18-22
    • Shagal, M.H.1    Maina, H.M.2    Donatus, R.B.3    Tadzabia, K.4
  • 6
    • 67349201967 scopus 로고    scopus 로고
    • Characterization of trace metals in vegetables by graphite furnace atomic absorption spectrometry after closed vessel microwave digestion
    • Bakkali, K.; Martos, N.R.; Souhail, B.; Ballesteros, E. Characterization of trace metals in vegetables by graphite furnace atomic absorption spectrometry after closed vessel microwave digestion. Food Chem. 2009, 2, 590-594.
    • (2009) Food Chem. , vol.2 , pp. 590-594
    • Bakkali, K.1    Martos, N.R.2    Souhail, B.3    Ballesteros, E.4
  • 7
    • 0032594589 scopus 로고    scopus 로고
    • Determination of cadmium, mercury and lead in seawater by electrothermal vaporization isotope dilution inductively coupled plasma mass spectrometry
    • Liu, H.W.; Jiang, S.J.; Liu, S.H. Determination of cadmium, mercury and lead in seawater by electrothermal vaporization isotope dilution inductively coupled plasma mass spectrometry. Spectrochim. Acta Part B-Atomic Spectrosc. 1999, 54, 1367-1375.
    • (1999) Spectrochim. Acta Part B-Atomic Spectrosc. , vol.54 , pp. 1367-1375
    • Liu, H.W.1    Jiang, S.J.2    Liu, S.H.3
  • 8
    • 54149091089 scopus 로고    scopus 로고
    • Determination of some inorganic metals in edible vegetable oils by inductively coupled plasma atomic emission spectroscopy (ICP-AES)
    • Pehlivan, E.; Arslan, G.; Gode, F.; Altun, T. Determination of some inorganic metals in edible vegetable oils by inductively coupled plasma atomic emission spectroscopy (ICP-AES). Grasas Y Aceites 2008, 59, 239-244.
    • (2008) Grasas Y Aceites , vol.59 , pp. 239-244
    • Pehlivan, E.1    Arslan, G.2    Gode, F.3    Altun, T.4
  • 9
    • 79952068171 scopus 로고    scopus 로고
    • Determination of heavy metal levels in medicinal plant Hemerocallis minor Miller by X-ray fluorescence spectrometry
    • Chuparina, E.V.; Aisueva, T.S. Determination of heavy metal levels in medicinal plant Hemerocallis minor Miller by X-ray fluorescence spectrometry. Environ. Chem. Lett. 2011, 9, 19-23.
    • (2011) Environ. Chem. Lett. , vol.9 , pp. 19-23
    • Chuparina, E.V.1    Aisueva, T.S.2
  • 11
    • 84871134734 scopus 로고    scopus 로고
    • Determination of trace heavy metals in milk using an ionic liquid and bismuth oxide nanoparticles modified carbon paste electrode
    • Ping, J.F.; Wu, J.; Ying, Y.B. Determination of trace heavy metals in milk using an ionic liquid and bismuth oxide nanoparticles modified carbon paste electrode. Chin. Sci. Bull. 2012, 57, 1781-1787.
    • (2012) Chin. Sci. Bull. , vol.57 , pp. 1781-1787
    • Ping, J.F.1    Wu, J.2    Ying, Y.B.3
  • 12
    • 77956179873 scopus 로고    scopus 로고
    • Stripping voltammetric determination of mercury (II) and lead (II) using screen-printed electrodes modified with gold films, and metal ion preconcentration with thiol-modified magnetic particles
    • Mandil, A.; Idrissi, L.; Amine, A. Stripping voltammetric determination of mercury (II) and lead (II) using screen-printed electrodes modified with gold films, and metal ion preconcentration with thiol-modified magnetic particles. Microchim. Acta 2010, 170, 299-305.
    • (2010) Microchim. Acta , vol.170 , pp. 299-305
    • Mandil, A.1    Idrissi, L.2    Amine, A.3
  • 14
    • 84870378546 scopus 로고    scopus 로고
    • Determination of lead and cadmium in rice samples by sequential injection/anodic stripping voltammetry using a bismuth film/crown ether/nafion modified screen-printed carbon electrode
    • Keawkim, K.; Chuanuwatanakul, S.; Chailapakul, O. Determination of lead and cadmium in rice samples by sequential injection/anodic stripping voltammetry using a bismuth film/crown ether/nafion modified screen-printed carbon electrode. Food Control 2013, 31, 14-21.
    • (2013) Food Control , vol.31 , pp. 14-21
    • Keawkim, K.1    Chuanuwatanakul, S.2    Chailapakul, O.3
  • 15
    • 46149083199 scopus 로고    scopus 로고
    • Development of disposable bulk-modified screen-printed electrode based on bismuth oxide for stripping chronopotentiometric analysis of lead (II) and cadmium (II) in soil and water samples
    • Kadara, R.O.; Tothill, I.E. Development of disposable bulk-modified screen-printed electrode based on bismuth oxide for stripping chronopotentiometric analysis of lead (II) and cadmium (II) in soil and water samples. Anal. Chim. Acta 2008, 623, 76-81.
    • (2008) Anal. Chim. Acta , vol.623 , pp. 76-81
    • Kadara, R.O.1    Tothill, I.E.2
  • 16
    • 77952669111 scopus 로고    scopus 로고
    • Determination of trace heavy metals in herbs by sequential injection analysis-anodic stripping voltammetry using screen-printed carbon nanotubes electrodes
    • Injang, U.; Noyrod, P.; Siangproh, W.; Dungchai, W. Determination of trace heavy metals in herbs by sequential injection analysis-anodic stripping voltammetry using screen-printed carbon nanotubes electrodes. Anal. Chim. Acta 2010, 668, 54-60.
    • (2010) Anal. Chim. Acta , vol.668 , pp. 54-60
    • Injang, U.1    Noyrod, P.2    Siangproh, W.3    Dungchai, W.4
  • 17
    • 79953005139 scopus 로고    scopus 로고
    • Electrocatalytic oxidation of NADH on graphene oxide and reduced graphene oxide modified screen-printed electrode
    • Zhang, L.; Li, Y.; Zhang, L.; Li, D.W.; Karpuzov, D. Electrocatalytic oxidation of NADH on graphene oxide and reduced graphene oxide modified screen-printed electrode. Int. J. Electrochem. Sci. 2011, 6, 819-829.
    • (2011) Int. J. Electrochem. Sci. , vol.6 , pp. 819-829
    • Zhang, L.1    Li, Y.2    Zhang, L.3    Li, D.W.4    Karpuzov, D.5
  • 18
    • 79951720594 scopus 로고    scopus 로고
    • Disposable biosensor based on graphene oxide conjugated with tyrosinase assembled gold nanoparticles
    • Song, W.; Li, D.W.; Li, Y.T.; Li, Y.; Long, Y.T. Disposable biosensor based on graphene oxide conjugated with tyrosinase assembled gold nanoparticles. Biosens. Bioelectron. 2011, 26, 3181-3186.
    • (2011) Biosens. Bioelectron. , vol.26 , pp. 3181-3186
    • Song, W.1    Li, D.W.2    Li, Y.T.3    Li, Y.4    Long, Y.T.5
  • 19
    • 79551569576 scopus 로고    scopus 로고
    • Direct electrodeposition of reduced graphene oxide on glassy carbon electrode and its electrochemical application
    • Chen, L.; Tang, Y.; Wang, K.; Liu, C.; Luo, S. Direct electrodeposition of reduced graphene oxide on glassy carbon electrode and its electrochemical application. Electrochem. Commun. 2011, 13, 133-137.
    • (2011) Electrochem. Commun. , vol.13 , pp. 133-137
    • Chen, L.1    Tang, Y.2    Wang, K.3    Liu, C.4    Luo, S.5
  • 20
    • 79955566363 scopus 로고    scopus 로고
    • Direct electrodeposition of graphene enabling the one-step synthesis of graphene-metal nanocomposite films
    • Liu, C.; Wang, K.; Luo, S.; Tang, Y.; Chen, L. Direct electrodeposition of graphene enabling the one-step synthesis of graphene-metal nanocomposite films. Small 2011, 7, 1203-1206.
    • (2011) Small , vol.7 , pp. 1203-1206
    • Liu, C.1    Wang, K.2    Luo, S.3    Tang, Y.4    Chen, L.5
  • 21
    • 33847762932 scopus 로고    scopus 로고
    • Spatially resolved Raman spectroscopy of single-and few-layer graphene
    • Graf, D.; Molitor, F.; Ensslin, K. Spatially resolved Raman spectroscopy of single-and few-layer graphene. NANO Lett. 2007, 7, 238-242.
    • (2007) NANO Lett. , vol.7 , pp. 238-242
    • Graf, D.1    Molitor, F.2    Ensslin, K.3
  • 23
    • 84861594481 scopus 로고    scopus 로고
    • Facile electrochemical codeposition of "clean" graphene-Pd nanocomposite as an anode catalyst for formic acid electrooxidation
    • Jiang, Y.Y.; Lu, Y.L.; Li, F.H.; Wu, T.S.; Niu, L.; Chen, W. Facile electrochemical codeposition of "clean" graphene-Pd nanocomposite as an anode catalyst for formic acid electrooxidation. Electrochem. Commun. 2012, 19, 21-24.
    • (2012) Electrochem. Commun. , vol.19 , pp. 21-24
    • Jiang, Y.Y.1    Lu, Y.L.2    Li, F.H.3    Wu, T.S.4    Niu, L.5    Chen, W.6
  • 24
    • 48849116984 scopus 로고    scopus 로고
    • Determination of trace heavy metals by sequential injection-anodic stripping voltammetry using bismuth film screen-printed carbon electrode
    • Chuanuwatanakul, S.; Dungchai, W.; Chailapakul, O.; Motomizu, S. Determination of trace heavy metals by sequential injection-anodic stripping voltammetry using bismuth film screen-printed carbon electrode. Anal. Sci. 2008, 24, 589-594.
    • (2008) Anal. Sci. , vol.24 , pp. 589-594
    • Chuanuwatanakul, S.1    Dungchai, W.2    Chailapakul, O.3    Motomizu, S.4
  • 25
    • 0037166117 scopus 로고    scopus 로고
    • Voltammetric behaviour and trace determination of copper at a mercury-free screen-printed carbon electrode
    • Honeychurch, K.C.; Hawkins, D.M.; Hart, J.P.; Cowell, D.C. Voltammetric behaviour and trace determination of copper at a mercury-free screen-printed carbon electrode. Talanta 2002, 57, 565-574.
    • (2002) Talanta , vol.57 , pp. 565-574
    • Honeychurch, K.C.1    Hawkins, D.M.2    Hart, J.P.3    Cowell, D.C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.