Volumn 45, Issue 4, 2013, Pages 592-597

Ultrasound of the inferior vena cava does not predict hemodynamic response to early hemorrhage

Author keywords

echocardiography; hemorrhage; inferior vena cava; phlebotomy; trauma; ultrasound

Indexed keywords

ADULT; ARTICLE; BLEEDING; BLOOD DONOR; BLOOD FLOW VELOCITY; BODY MASS; COMPUTER PROGRAM; CONTROLLED STUDY; DOPPLER ECHOGRAPHY; ECHOCARDIOGRAPHY; ECHOGRAPHY; FEMALE; FLUID THERAPY; HEART OUTPUT; HEMODYNAMIC MONITORING; HEMODYNAMIC PARAMETERS; HUMAN; IMAGING SYSTEM; INFERIOR CAVA VEIN; MALE; MEASUREMENT; NORMAL HUMAN; PHLEBOTOMY; PRIORITY JOURNAL; TREATMENT RESPONSE; ULTRASOUND; ULTRASOUND TRANSDUCER;

EID: 84884671795     PISSN: 07364679     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jemermed.2013.03.044     Document Type: Article
Times cited : (44)

References (16)
  • 1
    • 33749058841 scopus 로고    scopus 로고
    • Handcarried ultrasound measurement of the inferior vena cava for assessment of intravascular volume status in the outpatient hemodialysis clinic
    • J.M. Brennan, A. Ronan, and S. Goonewardena Handcarried ultrasound measurement of the inferior vena cava for assessment of intravascular volume status in the outpatient hemodialysis clinic Clin J Am Soc Nephrol 1 2006 749 753
    • (2006) Clin J Am Soc Nephrol , vol.1 , pp. 749-753
    • Brennan, J.M.1    Ronan, A.2    Goonewardena, S.3
  • 2
    • 77952543391 scopus 로고    scopus 로고
    • Inferior vena cava diameter correlates with invasive hemodynamic measures in mechanically ventilated intensive care unit patients with sepsis
    • J.C. Schefold, C. Storm, and S. Bercker Inferior vena cava diameter correlates with invasive hemodynamic measures in mechanically ventilated intensive care unit patients with sepsis J Emerg Med 38 2010 632 637
    • (2010) J Emerg Med , vol.38 , pp. 632-637
    • Schefold, J.C.1    Storm, C.2    Bercker, S.3
  • 3
    • 80052703854 scopus 로고    scopus 로고
    • Comparison of serial qualitative and quantitative assessments of caval index and left ventricular systolic function during early fluid resuscitation of hypotensive emergency department patients
    • A.J. Weekes, H.M. Tassone, and A. Babcock Comparison of serial qualitative and quantitative assessments of caval index and left ventricular systolic function during early fluid resuscitation of hypotensive emergency department patients Acad Emerg Med 18 2011 912 921
    • (2011) Acad Emerg Med , vol.18 , pp. 912-921
    • Weekes, A.J.1    Tassone, H.M.2    Babcock, A.3
  • 4
    • 58749115378 scopus 로고    scopus 로고
    • Inferior vena cava diameter (IVCD) measured with transesophageal echocardiography (TEE) can be used to derive the central venous pressure (CVP) in anesthetized mechanically ventilated patients
    • M.E. Arthur, C. Landolfo, M. Wade, and M.R. Castresana Inferior vena cava diameter (IVCD) measured with transesophageal echocardiography (TEE) can be used to derive the central venous pressure (CVP) in anesthetized mechanically ventilated patients Echocardiography 26 2009 140 149
    • (2009) Echocardiography , vol.26 , pp. 140-149
    • Arthur, M.E.1    Landolfo, C.2    Wade, M.3    Castresana, M.R.4
  • 5
    • 34347352203 scopus 로고    scopus 로고
    • Reappraisal of the use of inferior vena cava for estimating right atrial pressure
    • J.M. Brennan, J.E. Blair, and S. Goonewardena Reappraisal of the use of inferior vena cava for estimating right atrial pressure J Am Soc Echocardiogr 20 2007 857 861
    • (2007) J Am Soc Echocardiogr , vol.20 , pp. 857-861
    • Brennan, J.M.1    Blair, J.E.2    Goonewardena, S.3
  • 7
    • 4644226589 scopus 로고    scopus 로고
    • Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients
    • C. Barbier, Y. Loubieres, and C. Schmit Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients Intensive Care Med 30 2004 1740 1746
    • (2004) Intensive Care Med , vol.30 , pp. 1740-1746
    • Barbier, C.1    Loubieres, Y.2    Schmit, C.3
  • 8
    • 2542457136 scopus 로고    scopus 로고
    • The respiratory variation in inferior vena cava diameter as a guide to fluid therapy
    • M. Feissel, F. Michard, J.P. Faller, and J.L. Teboul The respiratory variation in inferior vena cava diameter as a guide to fluid therapy Intensive Care Med 30 2004 1834 1837
    • (2004) Intensive Care Med , vol.30 , pp. 1834-1837
    • Feissel, M.1    Michard, F.2    Faller, J.P.3    Teboul, J.L.4
  • 9
    • 77954384895 scopus 로고    scopus 로고
    • Inferior vena cava distensibility as a predictor of fluid responsiveness in patients with subarachnoid hemorrhage
    • R. Moretti, and B. Pizzi Inferior vena cava distensibility as a predictor of fluid responsiveness in patients with subarachnoid hemorrhage Neurocrit Care 13 2010 3 9
    • (2010) Neurocrit Care , vol.13 , pp. 3-9
    • Moretti, R.1    Pizzi, B.2
  • 10
    • 0025291657 scopus 로고
    • Comparative accuracy of Doppler echocardiographic methods for clinical stroke volume determination
    • J. Dubin, D.C. Wallerson, R.J. Cody, and R.B. Devereux Comparative accuracy of Doppler echocardiographic methods for clinical stroke volume determination Am Heart J 120 1990 116 123
    • (1990) Am Heart J , vol.120 , pp. 116-123
    • Dubin, J.1    Wallerson, D.C.2    Cody, R.J.3    Devereux, R.B.4
  • 11
    • 0032920336 scopus 로고    scopus 로고
    • Influence of increased abdominal pressure on steady-state cardiac performance
    • Y. Kitano, M. Takata, N. Sasaki, Q. Zhang, S. Yamamoto, and K. Miyasaka Influence of increased abdominal pressure on steady-state cardiac performance J Appl Physiol 86 1999 1651 1656
    • (1999) J Appl Physiol , vol.86 , pp. 1651-1656
    • Kitano, Y.1    Takata, M.2    Sasaki, N.3    Zhang, Q.4    Yamamoto, S.5    Miyasaka, K.6
  • 12
    • 84860221955 scopus 로고    scopus 로고
    • Ultrasound assessment of inferior vena cava collapsibility is not a valid measure of preload changes during triggered positive pressure ventilation: A controlled cross-over study
    • P. Juhl-Olsen, C.A. Frederiksen, and E. Sloth Ultrasound assessment of inferior vena cava collapsibility is not a valid measure of preload changes during triggered positive pressure ventilation: a controlled cross-over study Ultraschall Med 33 2012 152 159
    • (2012) Ultraschall Med , vol.33 , pp. 152-159
    • Juhl-Olsen, P.1    Frederiksen, C.A.2    Sloth, E.3
  • 13
    • 12744265204 scopus 로고    scopus 로고
    • Sonographic measurement of the inferior vena cava as a marker of blood loss
    • M. Lyon, M. Blaivas, and L. Brannam Sonographic measurement of the inferior vena cava as a marker of blood loss Am J Emerg Med 23 2005 45 50
    • (2005) Am J Emerg Med , vol.23 , pp. 45-50
    • Lyon, M.1    Blaivas, M.2    Brannam, L.3
  • 14
    • 80052756032 scopus 로고    scopus 로고
    • Ultrasound does not detect early blood loss in healthy volunteers donating blood
    • J. Resnick, R. Cydulka, E. Platz, and R. Jones Ultrasound does not detect early blood loss in healthy volunteers donating blood J Emerg Med 41 2011 270 275
    • (2011) J Emerg Med , vol.41 , pp. 270-275
    • Resnick, J.1    Cydulka, R.2    Platz, E.3    Jones, R.4
  • 15
    • 0028846860 scopus 로고
    • Confirmation of the safety of autologous blood donation by patients awaiting heart or lung transplantation. A controlled study using hemodynamic monitoring
    • E. Klapper, S.H. Pepkowitz, L. Czer, C. Inducil, L. Scott, and D. Goldfinger Confirmation of the safety of autologous blood donation by patients awaiting heart or lung transplantation. A controlled study using hemodynamic monitoring J Thorac Cardiovasc Surg 110 1995 1594 1599
    • (1995) J Thorac Cardiovasc Surg , vol.110 , pp. 1594-1599
    • Klapper, E.1    Pepkowitz, S.H.2    Czer, L.3    Inducil, C.4    Scott, L.5    Goldfinger, D.6
  • 16
    • 0026521015 scopus 로고
    • Cardiovascular responses to phlebotomy and sitting in middle-aged and elderly subjects
    • G.A. Kuchel, J. Avorn, M.J. Reed, and D. Fields Cardiovascular responses to phlebotomy and sitting in middle-aged and elderly subjects Arch Intern Med 152 1992 366 370
    • (1992) Arch Intern Med , vol.152 , pp. 366-370
    • Kuchel, G.A.1    Avorn, J.2    Reed, M.J.3    Fields, D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.