메뉴 건너뛰기




Volumn 60, Issue 3, 2013, Pages 813-820

2-D-3-D frequency registration using a low-dose radiographic system for knee motion estimation

Author keywords

2 D 3 D registration; 3 D motion estimation; Bone structures; Frequency domain; Low dose radiograph

Indexed keywords

2-D-3-D REGISTRATION; BONE STRUCTURE; CENTRAL-SLICE THEOREMS; EXPERIMENTAL PROTOCOLS; FREQUENCY DOMAINS; ITERATIVE OPTIMIZATION; LOW DOSE; MATHEMATICAL DETAILS;

EID: 84884617325     PISSN: 00189294     EISSN: 15582531     Source Type: Journal    
DOI: 10.1109/TBME.2012.2188526     Document Type: Article
Times cited : (9)

References (47)
  • 1
    • 79955834946 scopus 로고    scopus 로고
    • A review of 3D/2-D registration methods for image-guided interventions
    • P. Markelj, D. Tomazevic, B. Likar, and F. Pernus, "A review of 3D/2-D registration methods for image-guided interventions," Med. Image Anal., 2010, 2013.
    • (2010) Med. Image Anal.
    • Markelj, P.1    Tomazevic, D.2    Likar, B.3    Pernus, F.4
  • 3
    • 0027199753 scopus 로고
    • Knee motion after tibial osteotomy for arthrosis: Kinematic analysis of 7 patients
    • L. Weidenhielm, A. Wykman, A. Lundberg, and L. A. Brostrom, "Knee motion after tibial osteotomy for arthrosis: Kinematic analysis of 7 patients," Acta Orthop. Scand., vol. 64, pp. 317-319, 1993. (Pubitemid 23217090)
    • (1993) Acta Orthopaedica Scandinavica , vol.64 , Issue.3 , pp. 317-319
    • Weidenhielm, L.1    Wykman, A.2    Lundberg, A.3    Brostrom, L.-A.4
  • 4
    • 0343923679 scopus 로고    scopus 로고
    • A method to determine bone movement in the ankle joint complex in vitro
    • DOI 10.1016/S0021-9290(96)00187-X, PII S002192909600187X
    • T. Stahelin, B. Nigg, D. J. Stefanyshyn, A. van den Bogert, and S. Kim, "A method to determine bone movement in the ankle joint complex in vitro," J. Biomech., vol. 30, pp. 513-516, 1997. (Pubitemid 27170838)
    • (1997) Journal of Biomechanics , vol.30 , Issue.5 , pp. 513-516
    • Stahelin, T.1    Nigg, B.M.2    Stefanyshyn, D.J.3    Van Den, B.A.J.4    Kim, S.-J.5
  • 5
    • 30944442070 scopus 로고    scopus 로고
    • BoneMorphing versus freehand localization of anatomical landmarks: Consequences for the reproducibility of implant positioning in total knee arthroplasty
    • DOI 10.1080/10929080500389845, PII LGGM54412WL75262
    • N. Perrin, E. Stindel, and C. Roux, "Bone morphing vs freehand localisation of anatomical landmarks: Consequences on the reproducibility of implant positioning in total knee arthroplasty," Comput.-Aided Surg., vol. 10, pp. 301-309, 2005. (Pubitemid 43111906)
    • (2005) Computer Aided Surgery , vol.10 , Issue.5-6 , pp. 301-309
    • Perrin, N.1    Stindel, E.2    Roux, C.3
  • 6
    • 19644373467 scopus 로고    scopus 로고
    • Human movement analysis using stereophotogrammetry Part 4: Assessment of anatomical landmark misplacement and its effects on joint kinematics
    • DOI 10.1016/j.gaitpost.2004.05.003
    • U. D. Croce, A. Leardini, L. Chiari, and A. Cappozzo, "Human movement analysis using stereophotogrammetry part 4: assessment of anatomical landmark misplacement and its effects on joint kinematics," Gait Posture, vol. 21, pp. 226-237, 2005. (Pubitemid 41556841)
    • (2005) Gait and Posture , vol.21 , Issue.2 , pp. 226-237
    • Della, C.U.1    Leardini, A.2    Chiari, L.3    Cappozzo, A.4
  • 8
    • 0030608768 scopus 로고    scopus 로고
    • Surface marker cluster design criteria for 3D bone movement reconstruction
    • Dec.
    • A. Cappozzo, A. Cappello, U.D. Croce, and F. Pensalfini, "Surface marker cluster design criteria for 3D bone movement reconstruction," IEEE Trans. Biomed. Eng., vol. 44, no. 22, pp. 1165-1174, Dec. 1997.
    • (1997) IEEE Trans. Biomed. Eng. , vol.44 , Issue.22 , pp. 1165-1174
    • Cappozzo, A.1    Cappello, A.2    Croce, U.D.3    Pensalfini, F.4
  • 9
    • 33748289480 scopus 로고    scopus 로고
    • Propagation of anatomical landmark misplacement to knee kinematics: Performance of single and double calibration
    • DOI 10.1016/j.gaitpost.2006.08.001, PII S0966636206001585
    • R. Stagni, S. Fantozzi, and A. Cappello, "Propagation of anatomical landmark misplacement to knee kinematics: Performance of single and double calibration," Gait Posture, vol. 6, pp. 137-141, 2006. (Pubitemid 44332261)
    • (2006) Gait and Posture , vol.24 , Issue.2 , pp. 137-141
    • Stagni, R.1    Fantozzi, S.2    Cappello, A.3
  • 11
    • 36849081392 scopus 로고    scopus 로고
    • Interobserver and Intra-observer Errors in Obtaining Visually Selected Anatomical Landmarks During Registration Process in Non-Image-Based Navigation-Assisted Total Knee Arthroplasty
    • DOI 10.1016/j.arth.2006.10.010, PII S0883540306007133
    • W.Yau, A. Leung, K. Liu, CYan, L.Wong, and K Chiu, "Interobserver and intra observer errors in obtaining visually selected anatomical landmarks during registration process in non image based navigation assisted total knee arthroplasty," J. Arthroplasty, vol. 22, pp. 1150-1161, 2007. (Pubitemid 350218273)
    • (2007) Journal of Arthroplasty , vol.22 , Issue.8 , pp. 1150-1161
    • Yau, W.P.1    Leung, A.2    Liu, K.G.3    Yan, C.H.4    Wong, L.L.S.5    Chiu, K.Y.6
  • 12
    • 0035134053 scopus 로고    scopus 로고
    • Correcting for deformation in skin-based marker systems
    • DOI 10.1016/S0021-9290(00)00192-5, PII S0021929000001925
    • E. Alexander and T. Andriacchi, "Correcting for deformation in skin based marker systems," J. Biomech., vol. 34, pp. 355-361, 2001. (Pubitemid 32140998)
    • (2001) Journal of Biomechanics , vol.34 , Issue.3 , pp. 355-361
    • Alexander, E.J.1    Andriacchi, T.P.2
  • 13
    • 20444475413 scopus 로고    scopus 로고
    • Soft tissue artifact compensation in knee kinematics by double anatomical landmark calibration: Performance of a novel method during selected motor tasks
    • DOI 10.1109/TBME.2005.846728
    • A. Cappello, R. Stagni, S. Fantozzi, and A. Leardini, "Soft tissue artefact compensation in knee kinematics by double anatomical landmark calibration : Performance of a novel method during selected motor task," IEEE Trans. Biomed. Eng., vol. 52, no. 6, pp. 992-998, Jun. 2005. (Pubitemid 40813831)
    • (2005) IEEE Transactions on Biomedical Engineering , vol.52 , Issue.6 , pp. 992-998
    • Cappello, A.1    Stagni, R.2    Fantozzi, S.3    Leardini, A.4
  • 14
    • 0029329169 scopus 로고
    • A solidification procedure to facilitate kinematic analyses on video system data
    • L. Chèze, B. Fregly and J. Dimnet, "A solidification procedure to facilitate kinematic analyses on video system data," J. Biomech., vol. 28, pp. 879-884, 1995.
    • (1995) J. Biomech. , vol.28 , pp. 879-884
    • Chèze, L.1    Fregly, B.2    Dimnet, J.3
  • 16
    • 72249083544 scopus 로고    scopus 로고
    • In vivo estimation of the glenohumeral joint centre by functional methods: Accuracy and repeatability assessment
    • M. Lempereur, F. Leboeuf, S. Brochard, J. Rousset, V. Burdin, and O. Remy-Neris, "In vivo estimation of the glenohumeral joint centre by functional methods: accuracy and repeatability assessment," J. Biomech., vol. 43, pp. 370-374, 2010.
    • (2010) J. Biomech. , vol.43 , pp. 370-374
    • Lempereur, M.1    Leboeuf, F.2    Brochard, S.3    Rousset, J.4    Burdin, V.5    Remy-Neris, O.6
  • 18
    • 0032173357 scopus 로고    scopus 로고
    • Anatomy-based registration of CT-scan and intraoperative X-ray images for guiding a surgical robot
    • PII S0278006298090946
    • A. Guéziec, P. Kazanzides, B. Williamson, and R. H. Taylor, "Anatomy based registration of CT scan and intraoperative X ray images for guiding a surgical robot," IEEE Trans. Med. Imag., vol. 17, no. 5, pp. 715-728, Oct. 1998. (Pubitemid 128747727)
    • (1998) IEEE Transactions on Medical Imaging , vol.17 , Issue.5 , pp. 715-728
    • Gueziec, A.1    Kazanzides, P.2    Williamson, B.3    Taylor, R.H.4
  • 22
    • 0344012667 scopus 로고    scopus 로고
    • A robust method for registration of three dimensional knee implant models to two dimensional fluoroscopy images
    • Dec.
    • M. R. Mahfouz, W. A. Hoff, R. D. Komistek, and D. A. Dennis, "A robust method for registration of three dimensional knee implant models to two dimensional fluoroscopy images," IEEE Trans. Med. Imag., vol. 22, no. 12, pp. 1561-1574, Dec. 2003.
    • (2003) IEEE Trans. Med. Imag. , vol.22 , Issue.12 , pp. 1561-1574
    • Mahfouz, M.R.1    Hoff, W.A.2    Komistek, R.D.3    Dennis, D.A.4
  • 23
    • 77950970131 scopus 로고    scopus 로고
    • A new multi modal similarity measure for fast gradient based 2D 3-D image registration
    • Sep.
    • M. Pickering, A. Muhit, J. Scarvell, and P. Smith, "A new multi modal similarity measure for fast gradient based 2D 3-D image registration," in Proc. IEEE Eng. Med. Biol. Conf., pp. 5821-5824, Sep. 2009.
    • (2009) Proc. IEEE Eng. Med. Biol. Conf. , pp. 5821-5824
    • Pickering, M.1    Muhit, A.2    Scarvell, J.3    Smith, P.4
  • 24
    • 84884666703 scopus 로고    scopus 로고
    • Total knee arthroplasty three dimensional kinematic estimation prevision from a two dimensional fluoroscopy acquired dynamic model
    • to be published
    • B. P. Lebel, V. Pineau, S. L.Gouzy, L. Geais, J. J. Parienti, J. J. Dutheil, and C. H. Vielpeau, "Total knee arthroplasty three dimensional kinematic estimation prevision from a two dimensional fluoroscopy acquired dynamic model," Orthop. Traumatol. Surg. Res., to be published.
    • Orthop. Traumatol. Surg. Res.
    • Lebel, B.P.1    Pineau, V.2    Gouzy, S.L.3    Geais, L.4    Parienti, J.J.5    Dutheil, J.J.6    Vielpeau, C.H.7
  • 26
    • 0035694154 scopus 로고    scopus 로고
    • 2D 3-D rigid registration of X ray fluoroscopy and CT images using mutual information and sparsely sampled histogram estimators
    • L. Zollei, E. Grimson, A. Norbash, and W. Wells, "2D 3-D rigid registration of X ray fluoroscopy and CT images using mutual information and sparsely sampled histogram estimators," Comput. Vis. Pattern Recog., vol. 2, p. 696, 2001.
    • (2001) Comput. Vis. Pattern Recog. , vol.2 , pp. 696
    • Zollei, L.1    Grimson, E.2    Norbash, A.3    Wells, W.4
  • 28
    • 27744471166 scopus 로고    scopus 로고
    • Fast generation of digitally reconstructed radiographs using attenuation fields with application to 2D-3D image registration
    • DOI 10.1109/TMI.2005.856749
    • D. B. Russakoff, T. Rohlfing, K. Mori, D. Rueckert, A. Ho, J. R. Adler, Jr., and C. R. Maurer, Jr., "Fast generation of digitally reconstructed radiographs using attenuation fields with application to 2D 3-D image registration," IEEE Trans. Med. Imag., vol. 24, no. 11, pp. 1441-1454, Nov. 2005. (Pubitemid 41619221)
    • (2005) IEEE Transactions on Medical Imaging , vol.24 , Issue.11 , pp. 1441-1454
    • Russakoff, D.B.1    Rohlfing, T.2    Mori, K.3    Rueckert, D.4    Ho, A.5    Adler Jr., J.R.6    Maurer Jr., C.R.7
  • 30
    • 84055197359 scopus 로고    scopus 로고
    • Fast volume rendering using a shear warp factorization of the viewing transformation
    • Lacroute and Levoy, "Fast volume rendering using a shear warp factorization of the viewing transformation," Comput. Graph., 1999.
    • (1999) Comput. Graph.
    • Lacroute1    Levoy2
  • 31
    • 40649107638 scopus 로고    scopus 로고
    • Accurate and precise 2D-3D registration based on X-ray intensity
    • DOI 10.1016/j.cviu.2007.05.006, PII S1077314207000859
    • S. Aouadi and L. Sarry, "Accurate and precise 2D 3-D registration based on X ray intensity," Comp. Vis. Image Understanding, vol. 110, pp. 134-151, 2008. (Pubitemid 351375442)
    • (2008) Computer Vision and Image Understanding , vol.110 , Issue.1 , pp. 134-151
    • Aouadi, S.1    Sarry, L.2
  • 34
    • 43449110147 scopus 로고    scopus 로고
    • Biplanar 2D to 3D registration in Fourier domain for stereoscopic X ray motion tracking
    • b, a
    • D. Zosso, B. Le Callennecb, M. B. Cuadraa, K. Aminian, B. M. Jolles, and J.-P. Thiran, "Biplanar 2D to 3D registration in Fourier domain for stereoscopic X ray motion tracking," SPIE Med. Imag., vol. 6914, p. 1, 2008.
    • (2008) SPIE Med. Imag. , vol.6914 , pp. 1
    • Zosso, D.1    Le Callennec, B.2    Cuadra, M.B.3    Aminian, K.4    Jolles, B.M.5    Thiran, J.-P.6
  • 35
  • 36
    • 0024070721 scopus 로고
    • Image reconstruction from linograms: Implementation and evaluation
    • Sep.
    • P. Edholm, G. Herman, and D. Roberts, "Image reconstruction from linograms: Implementation and evaluation," IEEE Trans. Med, vol. 7, no. 3, pp. 239-246, Sep. 1988.
    • (1988) IEEE Trans. Med , vol.7 , Issue.3 , pp. 239-246
    • Edholm, P.1    Herman, G.2    Roberts, D.3
  • 39
    • 12344307235 scopus 로고    scopus 로고
    • 3D reconstruction of the proximal femur with low-dose digital stereoradiography
    • DOI 10.1080/10929080400018122
    • A. LeBras, S. Laporte, V. Bousson, D. Mitton, J. deGuise, J. Laredo, and W. Skalli, "3D reconstruction of the proximal femur with low dose digital stereoradiography.," Comput.-Aided Surg., vol. 9, pp. 51-57, 2004. (Pubitemid 40138068)
    • (2004) Computer Aided Surgery , vol.9 , Issue.3 , pp. 51-57
    • Le, B.A.1    Laporte, S.2    Bousson, V.3    Mitton, D.4    De Guise, J.A.5    Laredo, J.D.6    Skalli, W.7
  • 40
    • 41649099781 scopus 로고    scopus 로고
    • EOS system: Whole body simultaneous anteroposterior and lateral radiographs with very low radiation dose
    • J. Dubousset, G. Charpak, W. Skalli, G. Kalifa, and J. Lazennec, "EOS system : whole body simultaneous anteroposterior and lateral radiographs with very low radiation dose," Revue de Chirurgie Orthopédique, vol. 93, pp. 141-143, 2007.
    • (2007) Revue de Chirurgie Orthopédique , vol.93 , pp. 141-143
    • Dubousset, J.1    Charpak, G.2    Skalli, W.3    Kalifa, G.4    Lazennec, J.5
  • 41
    • 76649085863 scopus 로고    scopus 로고
    • EOS orthopaedic imaging system to study patellofemoral kinematics: Assessment of uncertainty
    • C. Azmy, S. Guérard, X. Bonnet, F. Gabrielli, and W. Skalli, "EOS orthopaedic imaging system to study patellofemoral kinematics: Assessment of uncertainty," J. Orthop. Traumatol. Surg. Res., vol. 96, pp. 23-32, 2010.
    • (2010) J. Orthop. Traumatol. Surg. Res. , vol.96 , pp. 23-32
    • Azmy, C.1    Guérard, S.2    Bonnet, X.3    Gabrielli, F.4    Skalli, W.5
  • 42
    • 84861690507 scopus 로고    scopus 로고
    • A 2D 3D registration with low dose radiographic system for in vivo kinematic studies
    • T. Jerbi, V. Burdin, E. Stindel, and C. Roux, "A 2D 3D registration with low dose radiographic system for in vivo kinematic studies," in Proc. Eng. Med. Biol. Conf., 2011, pp. 8070-8073.
    • Proc. Eng. Med. Biol. Conf., 2011 , pp. 8070-8073
    • Jerbi, T.1    Burdin, V.2    Stindel, E.3    Roux, C.4
  • 45
    • 0142135085 scopus 로고    scopus 로고
    • Optimal interpolating windowed discrete Fourier transform algorithms for harmonic analysis in power systems
    • H. Xue and R. Yang, "Optimal interpolating windowed discrete Fourier transform algorithms for harmonic analysis in power systems," IEE Proc. Generation Transmiss. Distrib., vol. 150, pp. 583-587, 2003.
    • (2003) IEE Proc. Generation Transmiss. Distrib. , vol.150 , pp. 583-587
    • Xue, H.1    Yang, R.2
  • 47
    • 77955508759 scopus 로고    scopus 로고
    • Three dimensional motion study of femur, tibia, and patella at the knee joint from biplane fluoroscopy and CT images
    • T. Ohnishi, M. Suzuki, A. Nawata, S. Naomoto, T. Iwasaki, and H. Haneishi, "Three dimensional motion study of femur, tibia, and patella at the knee joint from biplane fluoroscopy and CT images," Radiol. Phys. Technol., vol. 3, pp. 151-158, 2010.
    • (2010) Radiol. Phys. Technol. , vol.3 , pp. 151-158
    • Ohnishi, T.1    Suzuki, M.2    Nawata, A.3    Naomoto, S.4    Iwasaki, T.5    Haneishi, H.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.