-
1
-
-
0037318490
-
Stability of plasma analytes after delayed separation of whole blood: implications for epidemiological studies
-
Clark S., Youngman L.D., Palmer A., Parish S., Peto R., Collins R. Stability of plasma analytes after delayed separation of whole blood: implications for epidemiological studies. Int J Epidemiol 2003, 32(1):125-130.
-
(2003)
Int J Epidemiol
, vol.32
, Issue.1
, pp. 125-130
-
-
Clark, S.1
Youngman, L.D.2
Palmer, A.3
Parish, S.4
Peto, R.5
Collins, R.6
-
2
-
-
41649105344
-
Delay in separating blood samples affects creatinine measurement using the roche kinetic jaffe method
-
Ford L., Berg J. Delay in separating blood samples affects creatinine measurement using the roche kinetic jaffe method. Ann Clin Biochem 2008, 45(Pt 1):83-87.
-
(2008)
Ann Clin Biochem
, vol.45
, Issue.PART 1
, pp. 83-87
-
-
Ford, L.1
Berg, J.2
-
3
-
-
0036893555
-
Stability studies of twenty-four analytes in human plasma and serum
-
Boyanton B.L., Blick K.E. Stability studies of twenty-four analytes in human plasma and serum. Clin Chem 2002, 48(12):2242-2247.
-
(2002)
Clin Chem
, vol.48
, Issue.12
, pp. 2242-2247
-
-
Boyanton, B.L.1
Blick, K.E.2
-
4
-
-
0026534933
-
Plasma creatinine and the effect of delay in separation of samples
-
(Pt 3)
-
Simpson W.G. Plasma creatinine and the effect of delay in separation of samples. Ann Clin Biochem 1992, 29(Pt 3):307-309. (Pt 3).
-
(1992)
Ann Clin Biochem
, vol.29
, Issue.PART 3
, pp. 307-309
-
-
Simpson, W.G.1
-
5
-
-
84888244566
-
KDIGO 2012 clinical practice guideline for the evaluation and management of chronic kidney disease
-
KDIGO 2012 clinical practice guideline for the evaluation and management of chronic kidney disease. Kidney Int 2013, (Suppl. 3):40.
-
(2013)
Kidney Int
, Issue.SUPPL. 3
, pp. 40
-
-
-
6
-
-
34548045112
-
Stability of creatinine with delayed separation of whole blood and implications for eGFR
-
Shepherd J., Warner M.H., Kilpatrick E.S. Stability of creatinine with delayed separation of whole blood and implications for eGFR. Ann Clin Biochem 2007, 44(Pt 4):384-387.
-
(2007)
Ann Clin Biochem
, vol.44
, Issue.PART 4
, pp. 384-387
-
-
Shepherd, J.1
Warner, M.H.2
Kilpatrick, E.S.3
-
7
-
-
47749130800
-
Stability of common biochemical analytes in serum gel tubes subjected to various storage temperatures and times pre-centrifugation
-
Tanner M., Kent N., Smith B., Fletcher S., Lewer M. Stability of common biochemical analytes in serum gel tubes subjected to various storage temperatures and times pre-centrifugation. Ann Clin Biochem 2008, 45(Pt 4):375-379.
-
(2008)
Ann Clin Biochem
, vol.45
, Issue.PART 4
, pp. 375-379
-
-
Tanner, M.1
Kent, N.2
Smith, B.3
Fletcher, S.4
Lewer, M.5
-
8
-
-
84858379449
-
Stability study of 81 analytes in human whole blood, in serum and in plasma
-
Oddoze C., Lombard E., Portugal H. Stability study of 81 analytes in human whole blood, in serum and in plasma. Clin Biochem 2012, 45(6):464-469.
-
(2012)
Clin Biochem
, vol.45
, Issue.6
, pp. 464-469
-
-
Oddoze, C.1
Lombard, E.2
Portugal, H.3
-
9
-
-
0028934503
-
Serum cystatin C measured by automated immunoassay: a more sensitive marker of changes in GFR than serum creatinine
-
Newman D.J., Thakkar H., Edwards R.G., Wilkie M., White T., Grubb A.O., et al. Serum cystatin C measured by automated immunoassay: a more sensitive marker of changes in GFR than serum creatinine. Kidney Int 1995, 47(1):312-318.
-
(1995)
Kidney Int
, vol.47
, Issue.1
, pp. 312-318
-
-
Newman, D.J.1
Thakkar, H.2
Edwards, R.G.3
Wilkie, M.4
White, T.5
Grubb, A.O.6
-
10
-
-
78751614460
-
First certified reference material for cystatin C in human serum ERM-DA471/IFCC
-
Grubb A., Blirup-Jensen S., Lindstrom V., Schmidt C., Althaus H., Zegers I., et al. First certified reference material for cystatin C in human serum ERM-DA471/IFCC. Clin Chem Lab Med 2010, 48(11):1619-1621.
-
(2010)
Clin Chem Lab Med
, vol.48
, Issue.11
, pp. 1619-1621
-
-
Grubb, A.1
Blirup-Jensen, S.2
Lindstrom, V.3
Schmidt, C.4
Althaus, H.5
Zegers, I.6
-
11
-
-
84863524855
-
Estimating glomerular filtration rate from serum creatinine and cystatin C
-
Inker L.A., Schmid C.H., Tighiouart H., Eckfeldt J.H., Feldman H.I., Greene T., et al. Estimating glomerular filtration rate from serum creatinine and cystatin C. N Engl J Med 2012, 367(1):20-29.
-
(2012)
N Engl J Med
, vol.367
, Issue.1
, pp. 20-29
-
-
Inker, L.A.1
Schmid, C.H.2
Tighiouart, H.3
Eckfeldt, J.H.4
Feldman, H.I.5
Greene, T.6
-
12
-
-
84863981181
-
Accuracy of a GFR estimating equation over time in people with a wide range of kidney function
-
Padala S., Tighiouart H., Inker L.A., Contreras G., Beck G.J., Lewis J., et al. Accuracy of a GFR estimating equation over time in people with a wide range of kidney function. Am J Kidney Dis 2012, 60(2):217-224.
-
(2012)
Am J Kidney Dis
, vol.60
, Issue.2
, pp. 217-224
-
-
Padala, S.1
Tighiouart, H.2
Inker, L.A.3
Contreras, G.4
Beck, G.J.5
Lewis, J.6
-
14
-
-
0033003668
-
Evaluation of the dade behring N latex cystatin C assay on the dade behring nephelometer II system
-
Erlandsen E.J., Randers E., Kristensen J.H. Evaluation of the dade behring N latex cystatin C assay on the dade behring nephelometer II system. Scand J Clin Lab Invest 1999, 59(1):1-8.
-
(1999)
Scand J Clin Lab Invest
, vol.59
, Issue.1
, pp. 1-8
-
-
Erlandsen, E.J.1
Randers, E.2
Kristensen, J.H.3
|